HomeMy WebLinkAboutWQ0023310_Compliance Evaluation Inspection_20230131DocuSign Envelope ID: F1 7B67DC-BC7B-4FA1 -9676-1 CE4828B2A1 D ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Kevin Weston Murphy -Brown LLC PO Box 856 Warsaw, NC 28398-0856 NORTH CAROLINA Environmental Quality February 02, 2023 SUBJECT: Compliance Inspection Report Warsaw Sanitation Trailer Wash Non -discharge Permit No. WQ0023310 Duplin County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Warsaw Sanitation Trailer Wash on 1/31/2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0023310. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. Sincerely, EDocuSigned by: Toµ "T�n�cl. �cOA, For 7F141E73B6F3456... Morelia Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Michael Norris — electronic copy Derek Brown — electronic copy Upload to Laserfiche D_E QZ� North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 910.796.7215 DocuSign Envelope ID: F1 7B67DC-BC7B-4FA1 -9676-1 CE4828B2A1 D Dr QZ North Carolina Department of Environmental Quality I Division of Water Resources _ Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 oeo.ammemi�m.m o,i� /`� 910.796.7215 DocuSign Envelope ID: F17B67DC-BC7B-4FA1-9676-10E482862A1D Compliance Inspection Report Permit: WQ0023310 Effective: 09/17/19 Expiration: 11/30/24 Owner: Murphy -Brown LLC SOC: Effective: Expiration: Facility: Warsaw Sanitation Trailer Wash County: Duplin 2822 Hwy 24 W Region: Wilmington Warsaw NC 28398 Contact Person: Amy J Elmore Title: Env. Compliance Phone: 910-293-3434 Directions to Facility: From Warsaw, travel west on Hwy 24, turn right onto Old Courthouse Road. Facility is located on the left System Classifications: S1, Primary ORC: Bradley Devone Herring Certification: 988691 Phone: 910-385-8878 Secondary ORC(s): On -Site Representative(s): On -site representative Michael Leon Norris 910-284-0435 Related Permits: Inspection Date: 01/31/2023 Entry Time 09:OOAM Exit Time: 10:OOAM DocuSigned by: Primary Inspector: Helen I PerezElD645B4A39694BE... D S' d Phone: 910-796-7387 Secondary Inspector(s): � DouSi�9 nTed by: E-T7011'41E73B6F3456... Ati lY�affl oti 2/2/2023 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Wastewater Irrigation Facility Status: Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Record Keeping Use Records Treatment Lagoons End Use -Irrigation Treatment Influent Pump Station Treatment Flow Measurement Wells (See attachment summary) Page 1 of 5 DocuSign Envelope ID: F1 7B67DC-BC7B-4FA1 -9676-1 CE4828B2A1 D Permit: WQ0023310 Owner - Facility: Murphy -Brown LLC Inspection Date: 01/31/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Warsaw Sanitation Trailer Wash WWTF was conducted on January 31, 2023. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0023310. Michael Norris and Derek Brown were present during the inspection. This facility is a 2-bay, "clean" trailer wash facility with a SWECO solid -liquid mechanical separator and an oil -water separation unit. From the headworks, influent flows to a 2,573,134 gallon clay -lined lagoon and then irrigated on approximately 32 acres of spray fields consisting of Fescue and row crops. The facility estimates flow by water usage and is limited to 7,300,000 gallon per any consecutive 12 months. As of November 2022, the facility reported a flow of 2,796,200 gallons. Since the current NDMR form does not calculate flow as gallons per year, please be conscientious when calculating and reporting the 12-month rolling total gallons on the NDMR. There are plans to remove and reseed the Fescue on Zones 1-5 this spring. The Waste Utilization Plan has not had any recent changes. Operation/maintainence records were available for review and organized and complete. A review of records showed 1 NOD was issued for a freeboard limit violation. MW-1 R and MW-3R, located around the row crop Fields A throuh H, have had Nitrate limit exceedances for the majority of this permit cycle. Very little application on the fields nearest to those MWs, Field A and H, has occured. The Wilmington Regional Office continues to monitor the trends. The facility is compliant with Non -Discharge Permit WQ0023310. Please review the comment sections of the inspection report for more details. Page 2 of 5 DocuSign Envelope ID: F1 7B67DC-BC7B-4FA1 -9676-1 CE4828B2A1 D Permit: WQ0023310 Owner - Facility: Murphy -Brown LLC Inspection Date: 01/31/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Infiltration System ❑ Single Family Spray, LR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Lagoon Spray, LR Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: No comment. Treatment Influent Pump Station Yes No NA NE Is the pump station free of bypass lines or structures? 0 ❑ ❑ ❑ Is the general housekeeping acceptable? ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are floats/controls operable? ❑ ❑ ❑ Are audio and visual alarms available? 0 ❑ ❑ ❑ Are audio and visual alarms operational? ❑ ❑ ❑ # Are SCADA/Telemetry alarms required? ❑ ❑ ❑ Are SCADA/Telemetry available? ❑ ❑ ❑ Are SCADA/Telemetry operational? ❑ ❑ 0 ❑ Comment: Wastewater from the wash drains flows to a mechanical separator system that removes grit, trash, and shavings. The solids removed are emptied into a dumpster and hauled to the landfill. An oil -water separation unit is also used. The audible and visual alarms were operational when the high level float was pulled during the inspection. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Yes No NA NE ❑❑■❑ Page 3 of 5 DocuSign Envelope ID: F1 7B67DC-BC7B-4FA1 -9676-1 CE4828B2A1 D Permit: WQ0023310 Owner - Facility: Murphy -Brown LLC Inspection Date: 01/31/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? 0 ❑ ❑ ❑ Are the daily average values properly calculated? 0 ❑ ❑ ❑ Comment: The facility has a 7,300,000 gallons per year limit over any consecutive 12 months, and is estimated per the permit monitoring requirements. Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0 ❑ Is flowmeter operating properly? ❑ ❑ 0 ❑ Does flowmeter monitor continuously? ❑ ❑ 0 ❑ Does flowmeter record flow? ❑ ❑ 0 ❑ Does flowmeter appear to monitor accurately? ❑ ❑ 0 ❑ Comment: Record Keeping Yes No NA NE Is a copy of current permit available? 0 ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Page 4 of 5 DocuSign Envelope ID: F1 7B67DC-BC7B-4FA1 -9676-1 CE4828B2A1 D Permit: WQ0023310 Owner - Facility: Murphy -Brown LLC Inspection Date: 01/31/2023 Inspection Type: Compliance Evaluation Reason for Visit: Routine Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ 0 ❑ No treatment units bypassed since last inspection? 0 ❑ ❑ ❑ Comment: Operation/maintenance logs included field irrigation, freeboard and crop yield records as well as work orders for maintenance of the trailer wash facility. The soil analysis is completed annually by the Permittee, although it is only required every 3 years. The required monitoring parameters are reported from the NC Department of Agriculture Division's Waste Analysis Report. The monitoring wells are sampled and analyzed by Envirochem Lab. MW-1 R and MW-3R, located around the row crop Fields A throuh H, have had Nitrate limit exceedances for the majority of this permit cycle. Very little application on the fields nearest to those MWs, Field A and H, has occured. The Wilmington Regional Office continues to monitor the trends. End Use -Irrigation Yes No NA NE Are buffers adequate? 0 ❑ ❑ ❑ Is the cover crop type specified in permit? ❑ ❑ ❑ Is the crop cover acceptable? ❑ ❑ ❑ Is the site condition adequate? ❑ ❑ ❑ Is the site free of runoff / ponding? ❑ ❑ ❑ Is the acreage specified in the permit being utilized? ❑ ❑ ❑ Is the application equipment present? ❑ ❑ ❑ Is the application equipment operational? ❑ ❑ ❑ Is the disposal field free of limiting slopes? ❑ ❑ ❑ Is access restricted and/or signs posted during active site use? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ How close is the closest water supply well? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ # Info only: Does the permit call for monitoring wells? ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Are monitoring wells damaged? ❑ 0 ❑ ❑ Comment: Fields appeared to be well maintained. The irrigation equipment was last calibrated on 5/2/2022. The 3 MWs are all capped and appear to be in good condition. The lagoon's freeboard was 61 inches. Page 5 of 5