HomeMy WebLinkAboutNCG551106_Compliance Evaluation Inspection_20160907Water Resources
ENVIRONMENTAL QUALITY
September7, 2016
Walter Lee Tate
329 Southwood Drive
Kernersville, NC 27284
Subject: Compliance Evaluation Inspection
Permittee: Walter Lee Tate, Owner
Facility: 329 Southwood Drive, Kernersville, NC 27284
Permit: NCG550000 General Wastewater Permit
Certificate of Coverage: NCG551106
Forsyth County
Dear Mr. Tate:
PAT MCCRORY
Governor
DONALD R. VAN DER VAART
Secretary
S. JAY ZIMMERMAN
Director
Ron Boone and Justin Henderson, of the Winston Salem Regional Office (WSRO) of the NC Division
of Water Resources (DWR or the Division), conducted a compliance evaluation inspection of the single
family wastewater system at your residence on September 2, 2016. The State requires the Division to
inspect these types of systems every five years. An inspection report is attached for your records and
the inspection findings are summarized below.
2. The system consists of a septic tank, a dual stage filtration unit, chlorination unit, and the discharge
pipe. The entire system appears to be in good operating order. There was no discharge at the time of
the inspection. You have been taking samples as required in the permit every year and no exceedences
of the permit limits have been recorded to date, indicating that the system is treating the wastewater
well.
3. The septic tank was last pumped in December, 2013. You stated that you have it pumped a minimum
of every five years.
You have been adding chlorine tablets as needed to the chlorinator unit. The unit appears to be in
good condition. However, you are not using the correct type of chlorine. The chlorine you use is
intended for use in swimming pools, not for wastewater treatment. You should acquire wastewater
grade chlorine tablets. Please see the attachments for more information.
5. The permit fees of $60 per year have been paid annually as required and your permit is active and up
to date. You did not have a copy of the most recent Certificate of Coverage (COC). A copy is attached
for your records. Mr. Boone left you with a copy of the most recent general permit and technical bulletin.
6. Failure to properly operate and maintain your wastewater system can result in expensive repair costs
as well as failure of the system to properly treat the wastewater. It appears that your system is very
well maintained and should last a very long time if you continue to maintain it as well as you have up
to this point.
State of North Carolina I Environmental Quality I Water Resources
450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105
336 776 9800
If you have any questions regarding this letter or the NCG550000 general permit, please don't hesitate
to contact us at 336-776-9800.
Sincerely,
Sherri V. Knight, P.E.
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
Attachments:
1. Inspection Report
2. Certificate of Coverage NCG551106
3. Chlorine Technical Information
4. North Carolina & Other Chlorine Vendors
CC: WSRO Files
Central Files
NPDES Unit
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 IS I 3 I NCG551106 I11 12 16/09/02 17
18 I C I 19 I .c I 201
211111 I I I I I I II I I I I I I I I I I I I I I I I I
I I I I I I II I LI 11166
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA
------- —----- Reserved----------
67 I I 70 L_j 71 L 72 LJ 1 �, I
I�
731 I 174 75I I I I I I I I80
I I I
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
10:OOAM 16/08/02
13/08/01
329 Southwood Drive
329 Southwood Dr
Exit Time/Date
Pennit Expiration Date
Kernersville NC 27284
11:OOAM 16/09/02
18/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Walter Lee Tate,329 Southwood Dr Kernersville NC 27284///
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Other
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signatures) of Inspector(s) Agency/Office/Phone and Fax Numbers
Dale
Ron Boone WSRO WQ//336-776-9690/
/!
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers
Date
cr5�'V�'c CC-/1
l7114
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCG551106 I11 12 16/09/02 17 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Please refer to the attached inspection summary letter.
Page#
Permit: NCG551106
Inspection Date: 09/02/2016
Other
Owner - Facility: 329 Southwood Dnve
Inspection Type: Compliance Evaluation
Comment: Please refer to the attached inspection summary letter.
Yes No NA NE
Page#