February 19, 2016
Alcatel -Lucent USA, Inc.
Attn: Gary M. Fisher, Owner
600-700 Mountain Avenue
Mail Stop 7F-407A
New Providence, NJ 07974-2070
Subject: Compliance Evaluation Inspection
Permittee: Alcatel -Lucent USA Inc.
Facility: Salem Business Park Remediation Site
NPDES Permit #: NC0080853
Forsyth County
Dear Mr. Fisher:
Governor
DONALD R. VAN DER VAART
Secretary
S. JAY ZIMMERMAN
Director
Ron Boone of the Winston-Salem Regional Office of the NC Division of Water Resources (DWR or
the Division) conducted a compliance evaluation inspection (CEI) of the Salem Business Park Remediation
Site on February 10, 2016. The assistance and cooperation of Greg Stephenson, Operator in Responsible
Charge (ORC), was greatly appreciated. An inspection checklist is attached for your records and inspection
findings are summarized below.
General Information
The Salem Business Park Remediation Site is located at building #46 of Salem Business Park at
approximate coordinates of 36.056473, 80.230281. The permit authorizes Alcatel -Lucent USA Inc. to operate
this 0.302 MGD groundwater remediation system, which consists of extraction wells, bag filters, a tray air
stripper, and activated carbon filters, and discharge the treated effluent via outfall 001 to Salem Creek, which
is currently classified as Class C waters in the Yadkin Pee Dee River basin.
Site Review
Mr. Stephenson has done an excellent job of operating and maintaining the plant. The entire plant
was clean and appeared to be in excellent working order. Mr. Boone noted no discrepancies.
Documentation Review
All required documentation was reviewed. All of Mr. Stephenson's records were available, in order,
complete and current. No discrepancies were noted.
State of North Carolina Environmental Quality I Water Resources
450 West Hanes Mill Road, Suite 300 Winston-Salem, North Carolina 27105
336 776 9800
Thank you and please continue to operate the plant at optimum efficiency and in full compliance with
permit NC0080853. If you have any questions regarding the inspection or this letter, please call Mr. Boone
or me at (336) 776-9800.
Sincerely,
pyu,Y. h
Sherri V. Knight
Surface Water Regional Supervisor
Winston-Salem Regional Office
Division of Water Quality
Attachments:
1. BIMS Inspection Report
CC: WSRO -SWP
Central Files
NPDES Unit
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 LI 2 IS I 3 I Nc00e0e53 111 121 16/02/10 117
Type
18 1 r` I
1 I I
Inspector Fac Type
19 1.2j 201 I
21 1 1 1 1 1 I I III'I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 mil
I I 1
1 1 1 1 1 r6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------Reserved---------
67I 170I LJ I 71172 I N I 73I I 174 751
1I I I 1
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Salem Business Park remediation site
3370 Lexington Rd
Winston Salem NC 27107
Entry Time/Date
01:OOPM 18/02/10
Permit Effective Date
09/07/01
Exit Time/Date
02:OOPM 16/02/10
permit Expiration Date
14/06/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Gregory Martin Stephenson/ORC/336-784-2716/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Fred Bleachinger,3370 Lexington Rd Winston Salem NC 27107//336-784-2716/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement • Operations & Maintenance
Self -Monitoring Program Facility Site Review Effluent/Receiving Waters
Records/Reports
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers
WSRO WQ//338-778-8690/
Ron Boone-
Date
_..
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
.4- 4, rfr 14.1. (tf C01//4
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
3I
NPDES
NC0080853
11 121
yr/mo/day
16/02/10
117
Inspection Type
18u
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Please refer to the attached inspection summary letter.
Page# 2
Permit: NC0080853
Owner - Facility: Salem Business Park remediation site
Inspection Date: 02/10/2016 Inspection Type: Compliance Evaluation
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: None
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: None
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or> 5 MGD permitted flow) Do they operate 24/7 with a certified operator
on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Yes No NA NE
■ ❑ ❑ ❑
•❑ ❑ ❑
Yes No NA NE
•❑ On
• ❑ On
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
•
•
•
•
•
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
• ❑ ❑ ❑
▪ ❑ ❑ ❑
II ❑ ❑ ❑
Page# 3
Permit: NC0060653
Inspection Date: 02/10/2016
Owner - Facility: Salem Business Park remediation site
Inspection Type: Compliance Evaluation
Record Keeping
Facility has copy of previous year's Annual Report on file for review?
Comment: None
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment: None
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: Yes
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Incubator (Fecal Coliform.) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Comment: None
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Yes No NA NE
O n • ❑
Yes No NA NE
• ❑ OD
• ❑ ❑ ❑
❑ ❑ ■ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
❑ ❑ � ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑•
❑ ❑ ❑•
❑ ❑ ❑•
Yes No NA NE
❑ ❑ • ❑
❑ ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ ❑•
Page# 4
Permit: NC0080853 Owner - Facility: Salem Business Park remediation site
Inspection Date: 02/10/2016
Inspection Type: Compliance Evaluation
Effluent Sampling
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: None