Loading...
HomeMy WebLinkAboutNC0074241_Compliance Evaluation Inspection_20150922��� NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor September 22, 2015 Mr. Dave Thomson Associated Asphalt Greensboro, LLC P.O. Box 12626 Roanoke, VA 24027 SUBJECT: Compliance Evaluation Inspection Associated Asphalt - Greensboro, NC NPDES Permit No. NCO074241 Guilford County Dear Mr. Thomson: Donald van der Vaart Secretary On September 18, 2015, Mike Mickey of this office met with Bruce Weaver to perform a Compliance Evaluation Inspection on the stormwater discharge from the Associated Asphalt terminal located at 100 S. Chimney Rock Road. The inspection findings are detailed below and an inspection checklist is attached. I. Permit The permit expires next on August 31, 2016. You should receive a renewal notice around the first of the year. II. Self -Monitoring Program Submittal of the electronic Discharge Monitoring Reports (eDMRs) began in January 2015. A review of the monthly DMR's for the period September 2014 through August 2015 found Associated Asphalt to be compliant with the effluent limits for the above period. In regards to the permit monitoring requirements, it was noted that all sampling was performed per the frequencies specified in the permit. III. Flow Measurement The permit requires episodic flow monitoring. The discharge volume from the retention pond is calculated by opening the locked release valve four turns and then timing the release (-600 gpm). It was noted that no discharge occurred during the review months of September, January, February, April June and July. IV. Facility Site Review The stormwater treatment system consists of a 1.0 MG retention pond with a locked effluent release valve. The retention pond receives condensate from the boilers, stormwater from the truck and rail car loading areas and stormwater from the diked secondary containment areas which surround the ASTs: 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 Phone: 336-776-9800 \ Internet: www.ncwaterauality.org An. Equal Opportunity \ Affirmative Action Employer —Made in part by recycled paper Mr. Dave Thomson Page 2 September 22, 2015 VIL Records/Reports A review of the on -site files at the facility showed that the records were being maintained according to the permit. Meritech performs all laboratory analyses except for pH, which is measured by Associated Asphalt staff. VIII. Effluent/Receiving Waters The system discharges into a ditch at the perimeter fence. The effluent eventually reaches a tributary of the East Fork Deep River, class "WS-IV*" waters of the Cape Fear River Basin. No effluent was being discharged on the day of the inspection. Your efforts to comply with the permit are appreciated. Should you have any questions concerning this report, please contact Mike Mickey or me at (336) 776-9800. Sincerely, vaV, 4 Sherri V. Knight, PE Assistant Regional Supervisor Water Quality Regional Operations Section Division of Water Resources cc: Brace Weaver.(bweaver@associatedasphalt.com) Central Files WSRO Permit: NCO074241 Owner -Facility: AA Greensboro terminal Inspection Date: 09/18/2015 Inspection Type: compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The Associated Asphalt stormwater treatment system was found to be compliant with the NPDES permit limits for the review period September 2014 through August 2015. The 1 MG stormwater retention pond receives the following: *truck and railcar loading complex stormwater. *boiler condensate discharge. *stormwater from the secondary containment dikes that surround the ASTs. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ❑ 0 ❑ ❑ Is flow meter calibrated annually? ❑ ❑ M ❑ Is the flow meter operational? ❑ ❑ 0 ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Effluent flow from the single retention pond is calculated by opening a locked release valve four turns and then timing the release (- 600 gom). A log is kept that records the release date, flow duration and computed discharge volume. There were fourteen discharge events in the review period. No discharge occurred in the months of September, January, February, April, June and July. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ 0 ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The system discharges into a ditch at the perimeter fence. The effluent eventually reaches a tributary of the East Fork Deep River. class WS-IV* waters in the Cape Fear River Basin. The system was not discharging on the day of the inspection. Page# 3