Loading...
HomeMy WebLinkAboutNC0046418_Compliance Evaluation Inspection_20151012North Carolina Department of Environmental Quality Pat McCrory Donald R. van der Vaart Governor Secretary October 12, 2015 Mr. Tommy Spicer Wilkes County Schools 613 Cherry Street North Wilkesboro, NC 28659 SUBJECT: Compliance Evaluation Inspection Mountain View Elementary WWTP NPDES Permit # NC0046418 Wilkes County Dear Mr. Spicer: A Compliance Evaluation Inspection was performed by George Smith on October 7, 2015. Mr. Tommy Spicer, ORC was present at this inspection. The inspection is comprised of an overall evaluation of the facilities equipment, and capability to produce an effluent discharge that meets NPDES permit limits. Permit Your NPDES permit became effective on October 1, 2013 and expires on September 30, 2018. The eDMR requirement is included in the permit under Section A.(3). Wilkes County Schools did register for eDMR, and is working on eDMR submission. Please remember that both paper and eDMR submission are required at this time. Records & Reports Mr. Spicer maintains an operator log, which documents sampling, analysis, Operations & Maintenance, and his visitations. The records are well organized and maintained in a file cabinet. All are in excellent order. Facility Site Review One large surface sandfilter shows some light vegetation growing. The sandfilter appeared to be operating properly. The distribution lines are in good condition. The tablet chlorinator uses two tubes of Norweco calcium hypochlorite tablets. The tablet dechlorinator uses two tubes of Norweco sodium bisulfite tablets. The effluent well and pumps are working. Flow Measurement The flow is measured using the intake water meter. 450 W Hanes Mill Rd., Suite 300, Winston-Salem, NC 27105 Phone: 336-776-9800 \ Internet www.ncdenr.gov An Equal Opportunity 1 Affirmative Action Employer— Made in part by recycled paper Laboratory Wilkes County Schools is an approved field certified lab (# 5406). The pH calibration is performed with a SensIon 156, using a three-point calibration method (buffers 4, 7, 10), and a midrange check at 7.0. The calibration is recorded. Temperature is measured with the pH meter and is calibrated, documented, and is traceable to NIST. The Dissolved Oxygen is measured with an YSI, Model 50B meter, and the air calibration is performed. The Total Residual Chlorine is measured with a Hach DR2700 spectrophotometer. The 5-point annual calibration is scheduled to be performed during October 2015. Effluent/Receiving Waters The effluent in the lift station contained clear water, which discharges into the unnamed tributary to Mulberry Creek, Class C waters. Operations & Maintenance The facility is satisfactorily operated and maintained. Mr. Tommy Spicer, Grade II is the ORC; Mr. Stacy Higgins, Grade II, Back-up ORC. The surrounding trees have grown taller over the years and shade the sandfilter. Less sunlight may start to impede the biological treatment process in the future. Also, the leaves in the Fall of the year cause operational problems. The sand beds appear to need sand added. Self -Monitoring Program A review of the monthly self -monitoring reports from January 2014 through July 2014 showed four Dissolved Oxygen monitoring violations during January 2014; two Dissolved Oxygen monitoring violations during February 2014; one Temperature monitoring violation during May 2014. The compliance evaluation inspection is satisfactory. If you have any questions please contact George Smith or me at (336) 776-9800. Sincerely, W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ cc: WSRO Files United States Environmental Protection Agency n ^ r /'1 Washington, D.C. 20460 EPA Water Compliance Inspection Report OMForB Approved.. OM8 No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 )h, i 2 IS I 3 1 NC0046418 111 121 15/10/07 117 Type 1812j IIIIII111I1 Inspector Fac Type 191 Li 201 I 21111111 IIIIIIIIIII IIIIIII I111111 7511 r6 I I I I I I 180 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA --------------Reserved----------- 67I 1 7° 13I 71 IN I 72 LN 731 I 174 LJ I I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Mountain View Elementary School 5464 Mtn View Rd Hays NC 28635 Entry Time/Date 11:30AM 15/10/07 Permit Effective Date 13/12/01 Exit Time/Date 11:40AM 15/10/07 Permit Expiration Date 18/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Thomas J Spicer/ORC/336-651-4010/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Ken Barfield,201 W Main St Wilkesboro NC 28697//336-696-5512/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance • Records/Reports Self -Monitoring Program Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers f.� Date George SSSS�miithh . WSRO WQ//336-776-9700/ / `� /,t AD/7 0cajtJ lll/// Signatureof1�M`anagement Q A Reviewer Agency/Office/PhoneDate e and Fax Numbers f, /'yr/n/z 1'J an Ncpfit EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 Permit: NC0046416 Owner- Facility: Mountain View Elementary School Inspection Date: 10/07/2015 Inspection Type: Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: operate by observation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: eDMR required Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or:higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE • ▪ • ❑ ❑ ❑ Yes No NA NE ❑ ❑ •❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ On MOOD • ❑ ❑ ❑ • • • • • • . ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ M000 • ❑❑ o • ❑ ❑ ❑ Page# 3 Permit: NC0046418 Owner -Facility: Mountain View Elementary School Inspection Date: 10/07/2015 Inspection Typo: Compliance Evaluation Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: permits are at maintenance office and are avaliable. Sand Filters (Low rate (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re -circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) Comment: bed needs sand added Yes No NA NE • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ DEMO 11000 DOIND Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? MEI ❑ ❑ Are all pumps present? 1 ❑ ❑ ❑ Are all pumps operable? •❑ ❑ ❑ Are float controls operable? •❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ 1 ❑ Is audible and visual alarm available and operational? •❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑• ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? •❑ ❑ ❑ Is the tubing clean? ❑ ❑ •❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ • ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ ❑ representative)? Comment: grab samples collected and put on ice Disinfection -Tablet Are tablet chlorinators operational? • Yes No NA NE ❑ ❑ ❑ Page# 4 Permit: NC0046416 Owner - Facility: Mountain View Elementary School Inspection Date: 10/07/2015 Inspection Type: Compliance Evaluation Disinfection -Tablet Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Yes No NA NE • ❑ ❑ ❑ 2 ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ ❑ • Yes No NA NE Tablet ❑ ❑ • ❑ . ❑ ❑•❑ • ❑ ❑ ❑ • ❑ ❑ ❑ 2 Page# 5