HomeMy WebLinkAboutNC0066028_Compliance Evaluation Inspection_20151015North Carolina Department of Environmental Quality Pat McCrory Governor October 15, 2015 Mr. Tim Church Town of Lansing P.O. Box 266 Lansing, NC 28643 SUBJECT: Compliance Evaluation Inspection (CEI) Town of Lansing WWTP NPDES Permit # NCO066028 Ashe County Dear Mr. Church: Donald R. van der Vaart Secretary On October 9, 2015 an inspection was performed by George Smith. Mr. Tim Church, ORC, was present. The inspection is comprised of an overall evaluation in order to document compliance and noncompliance of: facilities equipment, capability to meet effluent limits, and terms & conditions with the NPDES permit. Permit Your NPDES permit became effective August 1, 2011 and expires March 31, 2016. As discussed during the previous inspection, the Town may request a permit flow of 30,000 gpd, thereby, changing the sampling requirements to a grab sample. This can be done during your permit renewal application. It is recommended that the Town register for eDMR. It will be a permit requirement in your next permit cycle. Please remember to submit your NPDES permit renewal application EPA Form A. Send to: Division of Water Resources WQ Permitting Section - NPDES 1617 Mail Service Center Raleigh, NC 27699-1617 Records & Reports An activity log was also kept in the building, which logs operator visitation and plant operations. All certificates of analytical analysis were kept on file along with chain of custody forms. Calibration records for pH, total residual chlorine, and temperature were documented. In summary, the records and reports documentation by Mr. Church is considered to be excellent. Facility Site Review The influent manual barscreen is maintained. 450 W Hanes Mill Rd., Suite 300, Winston-Salem, NC 27105 Phone: 336-776-9800 1 Internet: www.ncdenr.gov An Equal Opportunity \ Affirmative Action Employer— Made in part by recycled paper The two influent pumps work on alternating cycles and appeared to operating properly, and there was no evidence of overflows. Both blower pumps were operational, and delivering a gentle rolling action in the aeration basin. The aeration basin had little foam and a good color with an earthy odor. There was no evidence of straggler flock or solids from the up -flow clarifier cone unit. The discharge was clear. The backwash system is functioning properly. The Sanuril tablet chlorination unit was installed in the final effluent contact tank. One of the four tubes is used for disinfection. The unit is satisfactory. An in -ground tablet dechlorinator (Sanuril model) was installed. Sodium bisulfite tablets are used in one tube. Flow Measurement The recording flow chart is operating, and measures the height of water measured in inches passing through a 60' V-notch weir. The flow calibration log and charts were kept on -site for at least 3-years, and were well documented. The flow meter was calibrated and documented on August 5, 2015. Laboratory Total Residual Chlorine (TRC), Temperature, and pH are performed and recorded on the Daily Monitoring Report (DMR). The field parameters (TRC, Temp, pH) are currently performed under field parameter certification #5419. The pH is performed with a Hach Sension 1 meter using a two -point calibration (pH 4 & 10) and a mid -range check (pH 7), which is considered satisfactory. Mr. Church performs a temperature calibration against a NIST traceable thermometer. Total Residual Chlorine (TRC) is measured with a Hach DR2500, which is capable of detection to permit limit of 28 ug/L. The annual 5-point calibration is scheduled to be performed during October 2015. Effluent/Receiving Waters The effluent was clear with no color or solids present at the time of inspection. Big Horse Creek, Class C-trout, HQW waters, appeared to be clean with no visible impacts. Operations & Maintenance Mr. Tim Church is a grade IV operator and is the current ORC. Mr. Fred Walters is the Grade II back-up operator. The facility and grounds are maintained in excellent condition. Plant -Pro (Chlorine 68%) is used for disinfecting, and Plant -Pro (Sodium bisulfite) is used for dechlorination. They appear to work well. Settleability test is periodically performed as process control to judge the operational performance of this facility. For the most part, operation & maintenance is judged by observing plant performance. Self -Monitoring Program A review of the monthly self -monitoring reports from January 2015 through July 2015 showed no monitoring or limit violations. The effluent composite sample is collected with an Isco Model 3710 FR using the flow proportion method at 200 mL/ 1000 gal. The composite is stored in ice. Sludge Disposal The sludge removal is contracted through Doug Cox septic service and hauled to the Town of Jefferson W WTP. The compliance evaluation inspection is considered satisfactory. Mr. Church maintains the facility in an excellent manner. If you have any questions please contact George Smith or me at (336) 776-9800. Sincerely, W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ cc: WSRO Files United Slates Environmental Protection Agency Form Approved. EPA Washington, O C.20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fee Type 1 i, j 2 IS I 3 I NCO066028 I11 12 15/10/09 17 18 ICI 19 Li I 201 I 2111111111111111111111111111111111111111111I I66 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CA --------------Reserved------------ 67 L_� I 70 71 72 LrJ 731 174 75L_L L L I Ij8O Section 3: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:27AM 15/10/09 11/06/01 Lansing VvWrP 3322 Teaberry Rd Exit"Time/Date Permit Expiration Date Lansing NO 28643 11:40AM 15/10/09 16/03/31 Names) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Timothy Chumh/ORC/336-246-2165/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Tim Chumh,PO Box 67 Jefferson NO 286400067//336-246-2165/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance 0 Records/Reports Self -Monitoring Program 0 Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspectar(s) Agency/Office/Phone and Fax Numbers Date George S Smith WSRO WQ//336-776-9700/ C.G c 'Oy'-%���� o Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date ..�i� �✓�,E.Q,cK.�.� ,cdDEcQ _ �i2 - l�Ss�7o �-�-2o it —' EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# Permit: NCO066028 Inspection Date: 10/09/2015 Owner -Facility: Lansing WWTP Inspection Type: compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ 0 ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: permit renewal is given in this inspection letter Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or> 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ 0 ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the.ORC certified at,grade equal to or higher,than the facility glassificatioq?•,. ,❑. , ❑ ❑ ' ` ;,,.. Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 3 Permit: NCO066028 Owner - Facility: Lansing VVVVTP Inspection Date: 10/09/2015 Inspection Type: compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? S ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? N ❑ ❑ ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ S Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? 0 ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ M ❑ Comment: Are the tablets the proper size and type? ❑ ❑ ❑ Are tablet de -chlorinators operational? 0 ❑ ❑ ❑ Number of tubes in use? 1 Comment: Page# 4 Permit: NCO066028 Inspection Date: 10/09/2015 Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Owner -Facility: Lansing WWiP Inspection Type: Compliance Evaluation Effluent Sampling Is composite sampling Flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 5