Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0036881_Injection Event Record_20230127
North Carolina Department of Environmental Quality — Division of Water Resources INJECTION EVENT RECORD (IER) Permit Number WQ0036881 1. Permit Information Northrop Grumman Guidance and Electronics Co., Inc. Permittee Former Clifton Precision Site Facility Name 1995 NC Highway 141, Murphy, Cherokee County Facility Address (include County) 2. Injection Contractor Information Groundwater & Environmental Services, Inc. Injection Contractor / Company Name Street Address 310 Maxwell Road, Suite 600E Alpharetta, GA, 30009 City State Zip Code ( 866 ) 435-4424 Area code — Phone number 3. Well Information Number of wells used for injection see attached Well IDs see attached Were any new wells installed during this injection event? n Yes 1 No If yes, please provide the following information: Number of Monitoring Wells Number of Injection Wells Type of Well Installed (Check applicable type): ❑ Bored ❑ Drilled ❑ Direct -Push ❑ Hand -Augured ❑ Other (specify) Please include a copy of the GW-1 form for each well installed Were any wells abandoned during this injection event? n Yes 71 No If yes, please provide the following information: Number of Monitoring Wells Number of Injection Wells Please include a copy of the GW-30 for each well abandoned 4. Injectant Information see attached Injectant(s) Type (can use separate additional sheets if necessary Concentration see attached If the injectant is diluted please indicate the source dilution fluid. see attached Total Volume Injected (gal) 31,730 Volume Injected per well (gal) 5. Injection History Injection date(s) see attached see attached Injection number (e.g. 3 of 5) 2 of 12 Is this the last injection at this site? ❑ Yes E No I DO HEREBY CERTIFY THAT ALL THE INFORMATION ON THIS FORM IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE INJECTION WAS PERFORMED WITHIN THE STANDARDS LAID OUT IN THE PERMIT. Brian P. McCann Digitally signed by Brian P. McCann Date: 2023.01.26 17:45:28-05'00' 1/26/2023 SIGNATURE OF INJECTION CONTRACTOR DATE Brian P. McCann PRINT NAME OF PERSON PERFORMING THE INJECTION Submit the original of this form to the Division of Water Resources within 30 days of injection. Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-807-6464 Form UIC-IER Rev. 3-1-2016 I\JECTIO\ SEGNE\T GROUP 410 \JECTIO\ SEGNE\ T GROUP 440 \JECTIO\ SEGMENT GROUP 310 I\JECTIO\ SEGNE\T GROUP 430 0 P&ll 7 DF09 00 0 P0VI-7S Eo$ o E09 805e col® D08 ,07 /0 B/0 800 Rib Pm-48 Q,ScPM-4D Ni6 0 R K75 H15 Nlg 0 N/0 I \JECTIO\ SEGN GROUP 420 \JECTIO\ SEGN GPOJ P 340 (SEW-1,2,3) —1 HOLE 'NJECTIO\ 'SEGNE\T GROUP 330 I \JECTIO\ SEGNE\ T GROUP 320 REVISIONS SCALE 0 20 FEET BASE MAP DEVELOPED FROM PLANS BY CDM SMITH, TRS, AND ORIGIN LAND SURVEYING AND MAPPING, INC. IESI Engineering, P.C. NC# C-4390 & Innovative Engineering Solutions, Inc. 37 PEARL STREET #1 BRAINTREE, MASSACHUSETTS 02184 (508) 623-1224 INJECTION WELLS IN EACH SEGMENT NORTHROP GRUMMAN FORMER CLIFTON PRECISION SITE LOCATION 1995 NC HWY 141 MURPHY, NC 28906-6864 DRAWN IK CHECKED DF FILENAME NG—MURPHY REM PLAN DAB SEPT. 2022 FIGURE 6-3 Table 1. Completed and Projected 2023 EAD Amendment Dosing Amounts and Schedule Former Clifton Precision Site, Murphy, NC PERMIT # WQ0036881 Segment ID (inject equal volumes into all wells in segment) December 13-15, 2022 January 20-21, 2022 1/31/2023 2/15/2023 3/27/2023 4/26/2023 5/26/2023 TOTAL ACTUAL Volume of Diluted Amendments (gallons) TOTAL ACTUAL Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) McOH EVO DAP Water Flush pH Buffer Water Flush Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals 310 1,082 500 201 504 239 2,525 500 250 500 249 1,499 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 320 1,077 407 245 480 250 2,458 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 330 922 503 354 449 250 2,478 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 340 1,082 421 186 417 250 2,356 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 410(4) 665 504 174 504 138 1,985 565 194 509 227 1,495 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 420(4) 1,328 505 251 461 250 2,794 500 224 500 236 1,459 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 430 1,227 504 218 476 235 2,660 543 209 500 230 1,482 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 440 1,216 496 223 500 200 2,635 501 231 441 232 1,404 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 Batch Totals: 4,163 4,436 3,839 1,851 3,790 1,812 19,890 4,108 1,858 3950 1924.2 11,840 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 Segment ID (inject equal volumes into all wells in segment) 6/25/2023 7/25/2023 8/24/2023 9/23/2023 10/23/2023 11/22/2023 12/22/2023 Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Expected Approximate Volume of Diluted Amendments (gallons) Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et + pH Water Flush Event Totals Me/Et + DAP Water Flush Me/Et +pH Water Flush Event Totals 310 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 320 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 330 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 340 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 410(4) 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 420(4) 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 430 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 440 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 500 250 500 250 1,500 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 4,000 2000 4000 2000 12,000 Amendment Dose Basis Additives/flush Targeted Yearly Totals Batch Event Totals Diluted Volumes per Batch Dose & per Segment (ga Ions) # Injection events: 14 event # drums # totes Dilution Rate Me/Et Drums/ Batch Batch Volume Seg- ment Totals Year Totals 19,113 gal 1,365 25 5 18% Me/Et in water DAP: 2800 lbs 200 plus 200 #s DAP 12.5 4,000 500 56,000 Water flush: 28,000 gal 2,000 Water flush: 2,000 250 28,000 18% Me/Et in water NaOH year total: 350 lbs 25 NaHCO3 700 lbs 50 NaHCO3 12.5 4,000 500 56,000 Water flush: 28,000 gal 2,000 Water flush: 2,000 250 28,000 Total volumes: 12,000 1,500 168,000 Segment ID equal volumes injected into all wells in segment) Total Remedial Amendments Added to Date Me/Et EVO DAP NaOH NaHCO3 Total Volume (gal) (gal) (lbs) (lbs) (lbs) (gal) 310 371 50 5.2 13.0 4,024 320 370 46 5.1 12.7 3,958 330 341 51 4.9 12.3 3,979 340 371 46 4.7 11.8 3,856 430 178 76 53 5.0 12.6 4,142 440 161 75 50 4.9 12.2 4,039 NOTES: 1) EAD amendment dosing additives and amounts may vary based on recent groundwater data, injection back -pressures, and product availability. 2) Water flush volumes may vary based on recent source area and down -gradient groundwater data. 3) Injected volumes shown in italics are estimated due to operational issues with segment flow meters. 4) Segments 410 & 420 may receive lower amounts of amendments due to apparently lower injection yields as indicated by daylighting of injected fluids at wells including B03, B04, CO4, D05, D08. !e0 1/26/2023