HomeMy WebLinkAboutWQ0044035_Application_20230110DW ' Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Nu1111),,T: c C J to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Break Bread Ventures (company, municipality, IIOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ Statc/County ❑ Municipal 3. Signature authority's name: Rob Bryan per 15A NCAC 02T .0106(b) Title: CDO 4. Applicant's mailing address: 3517 Broadfield Read City: Charlotte State: NC Zip: 18 226-. 5. Applicant's contact information: Phone number: (704) 488-8680 Email Address: rbryaiiCnbrcakbrcadventures.com II. PROJECT INFORMATION: RECEIVED/NCDEQ/DWR JAN 10 2023 WQROS MOORESVILLE REGIONAL_ OFFICE ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Slim Chickens Restaurant 2. Application/Project status: ® Proposccl (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permil number: WQ00_ and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Cab -an -Lis 4. Approximate Coordinates (Decimal Dq),,rccs): L,`Itituda 35.4275° Longitude:-80.6121° 5. Parcel ID (if applicable): 5611-94-5395 & 561 1 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Alex Bockman, l'II.iccnse Number: 051253 Firm: Stimmel Associates, PA Mailing address: 601 Trade Street NW, Suit' "700 City: Winston Salem Statc::XC Zip: 27101-__ Phone number: (336 723-1067 (',mail ;Address: abocl<manC(�stimmelpa.com IV. WASTEWATER TREATMENT FACILITY (WAYFF) INFORMATION: 1. Facility Name: Rocky River Re ig onal W,is_tc\Natcr'1'r_catment plant Permit Number: NC0036269 Owner Name: Water and Sewer Authority 01'C';1l1arrus County V. RECEIVING DOWNSTREAM SEWERIN1,OHVIATION: 1. Permit Number(s): WQ 2. Downstream (Receiving) Sewer Information: S inch CXI Gravity ❑ Force Main 3. System Wide Collection System Permit NumlMr(s) (if applicable): WQCS00326 Owner Name(s): City of Concord FORM: FTA 06-21 Page I of 5 Division of Water Resources Application Number: State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Break Bread Ventures (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Rob Bryan per 15A NCAC 02T .0106(b) Title: CDO 4. Applicant's mailing address: 3517 Broadfield Road City: Charlotte State: NC Zip: 28226- 5. Applicant's contact information: Phone number: (704 488-8680 Email Address: rbryangbreakbreadventures.com H. PROJECT INFORMATION: 1. Project name: Slim Chickens Restaurant JAN 1 (;� ,-'(. WORDS MOORESVILLE REGIONAL OFFICE ❑ Privately -Owned Public Utility ❑ Other 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project vide the existing permit number:ow-mand issued date: 09/10/1999, For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Cabarrus 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.4275 ° Longitude:-80.6121 ° 5. Parcel ID (if applicable): 5611-94-5395 & 5611 (or Parcel ID to closest downstream sewer) M. CONSULTANT INFORMATION: 1. Professional Engineer: Alex Beckman, PELicense Number: 051253 Firm: Stimmel Associates, PA Mailing address: 601 Trade Street NW, Suite 200 City: Winston Salem State: NC Zip: 27101- Phone number: (336) 723-1067 Email Address: abockmangstimnielpa.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Rocky River Regional Wastewater Treatment Plant Permit Number: NCO036269 Owner Name: Water and Sewer Authority of Cabarrus County V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ 2. Downstream (Receiving) Sewer Information: 8 inch Z Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00326 Owner Name(s): City of Concord FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes ❑ No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ® Yes ❑ No ❑ N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ® Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic 100 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow', No. of Units Flow Restaurant, Single Service 20 gal/per seat 1 1960 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 1960 GPD a See 15A NCAC 02T .0114(b), (d),(e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 1960 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VH. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIH. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B); ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(_) & (g)? ® Yes ❑ No 15A NCAC 02T.0305(fl contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches ZWater mains (vertical - water over sewer preferred, including in benched trenches) 18 inches ZWater mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class R impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(fl or (g), see Section X.1 of this application * 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. "Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ❑ Yes ❑ No ® N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ® N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes El No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? [91 Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: I, _Alex Bockman , attest that this application for Slim Chickens Restaurant (Professional Engineer's name from Application Item III.1.) (Project Name from Application Item II.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version) , and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version) . Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: Oki I I I///// N A RG SEAL T•; 051253 01 /05/2 4R1 HI 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Rob Bryan , attest that this application for Slim Chickens Restaurant (Signature Authority Name from Application Item I.3.) (Project Name from Application Item II.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: ✓pm Date: 01/05/2023 FORM: FTA 06-21 Page 5 of 5 Lat Purser &Associates, Inc. BBV-Concord Parkway North (Concord), LLC ("BBV-Concord") c/o Break Bread Ventures, LLC Rob Bryan 3517 Broadfield Road Charlotte, NC 28226 MY PTS N the As a follow-up to our prior conversations and our telephone call with Ori Tuvia at NC DEQ, this letter serves as permission from Lat Purser & Associates, Inc. (LPA), as the holder of Permit No. WQ0016774, to add the new additional flow approved by the City of Concord (pursuant to the approval letter from the City for 1960 GPD of flow) to the existing permitted sewer collection system. We understand that this approval will result in a new permit being issued to you for just the additional flow into the existing system and that BBV-Concord will be responsible for this new permit and all requirements relative to the new flow provided thereby. I also understand that it is agreeable to all parties to pursue a transfer of the system to the City of Concord and the parties will work together towards that goal. Sincerely, Lat Purser & Associates, Inc. y C o d tti BBV- cord: By: Its: Commercial Real Estate Services 1 4530 Park Road • Suite 410 • Charlotte, NC 28209 1 t 704.519.4200 • f 704.525.8700 Charlotte • Raleigh • Jacksonville WI U-,040 Stimmel CHAR OTTE,N 282027101 CHARLOTTE, NC 28202 www.stimmelpa.com 336.723.1067 LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING January 06, 2023 Ori Tuvia, Environmental Engineer NCDEQ 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Tel.#: 704-235-2190 ori.tuvia .ncdenr.gov RE: Proposed Slim Chickens Restaurant — 948 Concord Parkway North Fast Track Sewer System Extension Application for Update to Permit for new service tap Wastewater Flow Application Project Narrative & Supporting Calculations This letter serves as both the Project Narrative associated with FTA 06-21 Application, as well as provide supporting calculations associated with flow allocation request. Project Narrative The site is located within a commercial area (C-2 Heavy Commercial zoning district), at 948 Concord Parkway North, on an outparcel lot of an existing Lowe's Home Improvement store. Lot is currently a vacant commercial lot, formerly a Wells Fargo bank. The scope of the project is to repurpose the existing building / lot to a proposed Slim Chickens restaurant. To the east and west of Concord Parkway North, there are several existing similar quick -serve restaurants that provide comparable purpose. The restaurant will include restrooms for customers, and a grease interceptor will treat all sanitary waste exiting the kitchen prior to discharging into a private sanitary sewer main that is currently tied into the existing lot. Supporting Calculations Below are the calculations associated with the 1960 gallons per day flow allocation request. • DEQ 2T calculations for a Restaurant (the proposed use) is based on 20 GPD per seat. Slim Chickens proposing 66 interior seats and 32 exterior seats for a total of 98 seats. 98 seats x 20 GPD = 1960 GPD. Please review this information and let us know if you have any questions. Sincerely, Jessie Lester, Partner - Project Manager SAPA (Stimmel Associates, PA) North Carolina Secretary of State Search Results Page 1 of 1 • File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online - Add Entity to My Email Notification List • View Filings • Print a Pre -Populated Annual Report form • Print an Amended a Annual Report form Limited Liability Company Legal Name Break Bread Ventures, LLC Information Sosld: 2068377 Status: Current -Active Date Formed: 10/19/2020 Citizenship: Domestic Annual Report Due Date: April 15th CurrentAnnual Report Status: Registered Agent: Bryan, Robert P., III Addresses Mailing Principal Office Reg Office Reg Mailing 1334 Bellemeade Lane 1334 Bellemeade Lane 3517 Broadfield Road 3517 Broadfield Road Charlotte, NC 28270 Charlotte, NC 28270 Charlotte, NC 28226 Charlotte, NC 28226 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Manager Robert P. Bryan III 3517 Broadfield Road Charlotte NC 28226 https://www.sosnc.gov/online_services/search/13usiness Registration —Results 1/10/2023 V !ORTH CAROLINA High Performance Living December 19, 2022 Break Bread Ventures, LLC Rob Bryan, Manager 3517 Broadfield Road Charlotte, NC 28226 P: (704) 488-8680 Email: rbryan@breakbreadventures.com 635 Alfred Brown Jr Court SW., P.O. Box 308, Concord, NC 28026-www.concordnc.gov SUBJECT: City of Concord Willingness to Serve Private Wastewater Collection System Extension/Modification City of Concord Project Title: Slim Chickens City of Concord Project # 2022-047 (Accela Case: PRS2022-02227) Receipt Date: December 16, 2022 WSACC Flow Acceptance December 2, 2022 (Complete Package) Engineering Plan Seal Date: November 17, 2022 WSACC Rocky River WWTP — NCO036269 City of Concord, Cabarrus County, North Carolina Dear Rob Bryan: This letter is to confirm that on December 2, 2022, our office received the Slim Chickens engineering plans and specifications, a digital copy of the engineering plans, and private wastewater collection system application, as prepared and sealed by Alexander H. Bockman, NCPE, with Stimmel Associates, PA for the private wastewater collection system extension consisting of approximately 20 linear feet of 4-inch sewer main with cleanouts and other appurtenances to serve a commercial fast-food restaurant with 98 seats and drive -through service located Concord Parkway, with an estimated commercial wastewater discharge addition of 1,960 GPD. The City of Concord's public wastewater collection system has the capacity to accommodate the estimated total average wastewater discharge of 1,960 GPD based on the information indicated on the NCDENR Fast Track application for the project. The City of Concord, however, will not guarantee the acceptance of any additional requests, revisions, deficiencies, or expansions that were not included in the consulting engineer's submitted engineering plans, specifications, reports, and/or calculations associated with this private system. The City of Concord's willingness to serve is effective only with respect to the project scope, nature and volume of wastewater described in the City of Concord Preliminary Wastewater Flow (PWWA) application and NCDEQ Fasttrack application for Slim Chickens and subject to the terms in the WSACC flow acceptance letter, dated December 13, 2022 for Slim Chickens; and the terms of the City of Concord sewer allocation policy, City of Concord Council's sewer allocation approval conditions, and the most current WSACC Sewer Allocation and Commitment Policy terms, as follows: The sewer capacity allocation is a preliminary process and does not guarantee commitment of sewer capacity by WSACC until the building permit is obtained and the system development fee is paid as is discussed in the Sewer Capacity Commitment section of this Policy. Engineering Phone (704) 920-5425 0 Fax (704) 786.4521 The sewer capacity allocation is automatically cancelled upon the passing of the Expiration Date if the project has not commenced. Commencement of the project is defined as being under construction with grading initiated and significant water and sewer infrastructure in progress. The sewer capacity allocation may also be cancelled if- (i) the project's water and sewer infrastructure is not completed within three (3) years from the date of the flow acceptance letter, (ii) building permits are not obtained and system development fees are not paid within four (4) years from the date of the flow acceptance letter, (iii)the jurisdiction and developer make a request to WSACC in writing that the allocation be rescinded, or (iv) a mutual agreement is reached between WSACC, the jurisdiction and the developer that the allocation be rescinded. THE CITY OF CONCORD AND ITS STAFF ARE NOT RESPONSIBLE FOR ERRORS IN DESIGNS, CALCULATIONS, DRAWINGS OR STATEMENTS SUBMITTED BY APPLICANTS, THEIR TECHNICAL CONSULTANTS, SURVEYORS OR ENGINEERS. THE CITY OF CONCORD AND ITS STAFF ARE NOT RESPONSIBLE FOR FINDING OR CORRECTING ANY ERRORS OR DEFICIENCIES IN PLANS SUBMITTED TO THE CITY OF CONCORD FOR REVIEW AND APPROVAL. THE CITY OF CONCORD DISCLAIMS ANY LIABILITY FOR ERRORS CONTAINED IN PLANS SUBMITTED TO THE CITY OF CONCORD. THE SIGNATURE OF THE CITY OF CONCORD ENGINEER MAY NOT BE RELIED UPON TO ESTABLISH ANY DUTY OR RELATIONSHIP (SUCH AS A THIRD - PARTY BENEFICIARY) WITH ANY PARTY USING THIS PLAN OR DRAWING. PARTIES USING THIS DOCUMENT SHOULD CONDUCT THEIR OWN REVIEW AND ANALYSIS FOR MAKING A DECISION IN RELIANCE ON THIS DOCUMENT. This letter shall not be construed as an Authorization to Construct by the City of Concord. All applicable permits associated with this project must be obtained and copies must be presented on site prior to commencement of the work. IMPORTANT: The Break Bread Ventures, LLC must submit a copy of the NCDEQ-Division of Water Resources, Non -Discharge approval letter and authorization to construct permit and a copy of the engineer's final certification to the City of Concord prior to interconnection with the City of Concord's public wastewater collection system. The City of Concord must be present to observe the connection of this private system, in order to meet the Standard Specifications for Wastewater Collection and Water Distribution for Cabarrus County. Contact Gary Stansbury, Construction Administrator, at (704) 920- 5404 at least 48 hours prior to the initiating system connection. Construction of the private wastewater collection system project shall be in accordance with 15A NCAC 02T.0300; The Division of Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable. This does not constitute an acceptance of any part of the project that does not meet North Carolina Administrative Code Title 15A 02T.0300, as applicable. Failure to comply may result in penalties in accordance with North Carolina General Statute § 143-215.6A through § 143-215.6C, construction of additional or replacement facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Engineering Phone (704) 920.5425 • Fax (704) 786,4521 Please be aware that the City will not assume any responsibility for the operation and maintenance of the subject private wastewater collection system that is located on the property beyond the public utility easement/rights-of-way. The Break Bread Ventures, LLC will be responsible for complying with the regulatory requirements in accordance with North Carolina Administrative Code Title 15A 02T.0300, the maintenance and operation of the private wastewater collection system, and obtaining the required permit approvals associated with the private wastewater collection system. Please review this section of the Administrative Code prior to submitting your application to the State. If the permit applicant is unable to perform all of the operation and maintenance duties required by the State's Administrative Code, a private wastewater collection system extension should not be requested. The City reserves the right to disconnect the subject wastewater collection system and potable water service from the City of Concord's public system if improper operation and maintenance of the private system violations of any Federal, State or local regulations, ordinances, or policies. After the private wastewater collection system has been constructed and prior to water service activation, the Break Bread Ventures, LLC must complete the NCDEQ DWR regulatory requirements in accordance with North Carolina Administrative Code 15A NCAC 2T for final approval and the Break Bread Ventures, LLC's engineer must certify that the private wastewater collection system has been installed in accordance with North Carolina Administrative Code 15A NCAC 2T. A copy of the engineer's certifications, private system final approval/acceptance letter, and correspondences, as applicable must be submitted to the City of Concord. Sincerely, Sincerely, City of Concord City of Concord Digitally signed by Sue lye S U e 1u ' yd a Date: 2022.12.19 13:56:24-05'00' M. Sue Hyde, PE (Date) Director of Engineering Attachments: WSACC Approval Letter FTSE-01/14 signed by Sue M. Hyde on Dec. 7, 2022 FTSE-01/14 signed by J. Thomas Hahn, on Dec 15, 2022 Electronic cc: Project #2022-047 Stimmel Associates, PA Alexander H. Bockman, NCPE, 601 Trade Street NW, Suite 200 Winston-Salem, NC 27101 P: (336) 723-1067 1 Email: abrockman@stimmelpa.com Gary Stansbury, Construction Administrator, stansburyg@concordnc.gov M. Sue Hyde, Director of Engineering, hydes@concordnc.gov 12/19/2022 Kevin Plemmons, PE (Date) Water Resources Engineering Manager Engineering Phone (704) 920-5425 • Fax (704) 786-4521 WASTEWATER FLOW ACCEPTANCE FORM FOR THE WATER AND SEWER AUTHORITY OF CABARRUS COUNTY Jurisdiction Requesting Flow Acceptance: Private -Flow Date: 12/5/2022 ®City of Concord ❑City of Kannapolis ❑Town of Harrisburg ❑Town of Mt. Pleasant ❑Charlotte Mecklenburg Utilities Project Title, Description, and Number of Lots/Unit: Project Title: Slim Chickens —(Project #2022-047 & PRS2022-02227) Description: The Slim Chickens engineering plans and specifications, as prepared and sealed by Alex Bockman, NCPE, with Stimmel Associates, PA, for the private wastewater collection system extension consisting of approximately 20 linear feet of 4-inch sanitary sewer and other appurtenances to serve a 3,523 sq. ft. restaurant located off/on of US-29/US- 601 Concord Parkway N, with a domestic wastewater discharge of 1,960 GPD. *Number of Lots: 1 OR *Number of Units: *Must be included in request. Where will the new line be connected: ❑ Directly into a WSACC Interceptor ❑ Into the Jurisdiction's existing collection system ® Into a private line Describe the location of the tie-in line to which the new sewer line will connect: The proposed 4-inch private sanitary sewer extension will tie in to the existing private line, which extends to the 24, 30, and 36-inch public sanitaryy sewer system, and extends to the 48-inch Irish Buffalo Creek RCP WSACC Irish Buffalo Creek Sewer Outfall Interceptor Which WSACC Interceptor will the flow ultimately be discharged into: 48-inch material WSACC Name Interceptor What is the WSACC manhole number that the flow will be discharged into? +/- Node 011067 What is the quantity of flow that will be discharged? 1,960 GPD Flow type: ® Domestic 100 ❑ Commercial % ❑ Industrial % Name of wastewater treatment facility (WWTF) receiving wastewater: ® Rocky River Wastewater Treatment Facility — Permit #NC0036269 ❑ Muddy Creek Wastewater Treatment Facility — Permit #NC0081621 Design drawings of new lines will be submitted to WSACC with the request for acceptance. Drawings can be submitted as a digital file (DWG) or distance and bearing starting with the tap on existing infrastructure. If the new line is to connect directly into a WSACC interceptor, detailed drawings including specification of the tap, will be required before flow acceptance will be provided. Mark Lomax at 704-786-1783, ext. 231, must be notified 48 hours in advance of a connection into a WSACC interceptor. WSACC will inspect connection before, during, and after completion. If construction is not started within two (2) year from the date of approval of the flow acceptance for this project, the approval is rescinded and a second request and approval will be required for the project. WSACC USE ONLY: :0 DATE: Current sewer model shows an Interceptor as being surcharged south of the manhole in question. Approved ❑ Not Approved Current Sewer Model shows: D-WR State of North Carolina Department of Environmental Quality Di isl.an of 'kaV Ater.Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—01/14) (JURISDICTION USE ONLY) Slim Chickens —(Project #2022-047 & PRS2022-02227) Jurisdiction Requesting Flow Acceptance for Collection System: ®City of Concord ❑City of Kannapolis ❑Town of Harrisburg ❑Town of Mt. Pleasant ❑Charlotte Mecklenburg Utilities Project Title, Description, and Number of LotstUnit: Project Title: Slim Chickens —(Project #2022-047 & PRS2022-02227) Lots: 1 Description: The Slim Chickens engineering plans and specifications, as prepared and sealed by Alex Bockman, NCPE, with Stimmel Associates, PA, for the private wastewater collection system extension consisting of approximately 20 linear feet of fl- inch sanitary sewer and other appurtenances to serve a 3,523 sq. ft. restaurant located off/on of US-29/US-601 Concord Parkway N, with a domestic wastewater discharge of 1,960 GPD. What is the quantity of flow that will be discharged? 1,960 GPD Flow type: ® Domestic 100 % ❑ Commercial % ❑ Industrial % Section I - List the Jurisdiction's pump stations located between the project connection point and the WSACC Interceptor connection point. Pump Station (Name or Number) Firm Capacity * MGD (A) Design Average Daily Flow ** (Firm/pf) MGD (B) Approx. Current Average Daily Flow MGD (C) Obligated, Not Yet Tributary Daily Flow MGD (D) _ (B+C) Total Current Flow Plus Obligated Flow MGD (E)=(A-D) Available Capacity*** MGD *The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor not less than 2.5. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where Available Capacity is < 0. Section II. Jurisdiction's Certification Statement: I, M. Sue Hyde, certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving WSACC interceptor; and the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden on any downstream pump station in route to the receiving WSACC interceptor normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Section I plus all attached planning assessment addendums for which, to the best of my knowledge, will not adversely affect the downstream sewer capacity. Signature of this form indicates accept xn�bi any astsigmat ( Ao Sue Hyde Sue Hyde Date: 2022.12.07 10:16:14 -0s�00' Jurisdiction's Signing Official Signature Date Revision Date: 08/09/13 WSACC NO 110011015 a HC Ster ft sedor • ISO 15001:1018 December 13, 2022 Mr. Lloyd Payne City Manager City of Concord P.O. Box 308 Concord, NC 28026-0308 Subject: Flow Acceptance Request — City of Concord Slim Chickens Restaurant Dear Mr, Payne: WATER & SEWER AUTHORITY OF CABARRUS COUNTY 232 Davidson Hwy. Concord, NC 28027 704.786.1783 0 701.795.1564 Fax www.wsacc.org This is a notice of capacity for the flow acceptance request received by the Water and Sewer Authority of Cabarrus County (WSACC) from the City of Concord on December 7, 2022. WSACC has or will have capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the commercial wastewater from the proposed project entitled Slim Chickens Restaurant, located off/on US-29/US-601 Concord Parkway N. The referenced project will serve a restaurant with 98 seats, with a projected wastewater flow of 1,960 gallons per day (gpd). The wastewater generated by this project will be conveyed through a proposed and existing sewer system and then enter WSACC's system at the existing 48-inch Irish Buffalo Creek Interceptor. WSACC acknowledges it has or will have capacity for wastewater from the proposed development based on information provided by Stimmel Associates, PA (Civil Engineer for the project) using North Carolina Department of Environmental Quality (NCDEQ) wastewater flow guidelines. If construction of this project does not commence within two (2) years of the date of this notice, the notice is rescinded and a second request and notice will be required before flow capacity is accepted. Please notify WSACC, in writing, when construction of this project is initiated. This sewer capacity allocation may also be cancelled pursuant to the conditions set forth in the WSACC Sewer Allocation and Commitment Policy. Please note that the final commitment to service to provide rvasteivater treatment services shall occur upon application for a building permit for the project and when system development fees are paid pursuant to N.C.G.S. §162A, Article 8. ,� /1 If you have any questions, please call me at (704) 7 X N Executive Director cc; Sherri Moore/Concord Alex Bookman, PE/Stimmel Associates, PA Chad VonCannon, PE/WSACC Thomas Hahn, PE/WSACC Mark Lomax/WSACC Trent Gobble/WSACC 1 Divis-loFi of Water Resonrctes (WSACC USE ONLY) Slim Chickens State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracldng for Sewer Extension Applications (FTSE--10/18) Section 1. Name of wastewater treatment facility (WWTF) receiving wastewater: ® Rocky River Wastewater Treatment Facility— Permit #NC0036269 ❑ Muddy Creels Wastewater Treatment Facility — Permit #NC0081621 WWTP facility's permitted flow, MGD 26.500 Estimated obligated flow not yet tributary to the WWTP, MGD 3.467 WWTP facility's actual avg. daily flow, MGD 20.971 (79.14% of permit) Total flow for this specific request, MGD 0.002 Total actual and obligated flows to the facility, MGD 24.440 Percent of permitted flow used 92.23% Section Il. Pump stations along the route from the Jurisdiction's connection point to the WWTP, Pump Station Pump Station Firnt A Designs Average B Approx. CURCIU (C) Obligated, Not Yet (D)=(B+C) Total Current Flow (B)=(A-D) (Name or Number) Permit No. Capacity * MGD Daily Flow ** im/ (1'• PO Average Daily Flow Tributary Daily Flow Plus Obligated flow Available Capacitykkk MGD MGD NIGD MGDlvIGD RRRWWTP NCO036269 55.440 22,176 12.812 0.786 13.598 8.578 MPS * The Firm Capacity (design now) or any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pri not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Crilerin. ***A Planning Assessment Addendum shall be attached for each pump station located between (lie project connection point and the WWTP where Available Capacity is < 0. Section Ill. WSACC Certification Statement: I, Michael Wilson, certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route from the connection to the WSACC interceptor to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning aslessment where applic le. This analysis has been performed in accordance with local established policies and procedures usi t {e t available data// his certification applies to those items listed above in Section I and Section 11 plus all attached planning a n4 addendums For hich I am the responsible party. Signature of this form indicates WSACC's guarantee of capacity fo h' water flow. No ithslanding the guarantee of capacity, WSACC does not make a commitment to service this wastes a r until a • ildii g rot is requested through the Cabarrus Coun Building Inspections Department and WSA ceiv ay nt of tl ste elopment Fee. / WSACC's Signing Officfdl Signature WASTEWATER FLOW ACCEPTANCE FORM FOR THE WATER AND SEWER AUTHORITY OF CABARRUS COUNTY Jurisdiction Requesting Flow Acceptance: Private -Flow Date: 12/5/2022 ®Cityof Concord []City of Kannapolis OTown of Harrisburg ❑Town of Mt. Pleasant ❑Charlotte Mecklenburg Utilities Project Title, Description, and Number of Lots/Unit: Project Title: Slim Chickens —(Protect #2022-047 & PRS2022-02227) Description: The Slim Chickens engineering Rlans and suecifications as prepared and sealed by Alex Bockman NCPE with Stintmel Associates PA for the private wastewater collection system extension consisting of approximately 20 linear feet of 44nch sanitary sewer and other appurtenances to serve a 3,523 soft restaurant located off/on of US-29/US- 601 Concord Parkway N, with a domestic wastewater discharge of 1,960 GPD. *Number of Lots: 1 OR *Number of Units: *Must be included in request. Where will the new line be connected: ❑ Directly into a WSACC Interceptor ❑ Into the Jurisdiction's existing collection system ® Into a private line Describe the location of the tle4n line to which the new sewer line will connect: The proposed 4-inch private sanitary sewer extension will tie in to the existingprivate line, which extends to the 24, 30, and 36-inch public sanitary sewer system and extends to the 48-inch Irish Buffalo Creek RCP WSACC Irish Buffalo Creek Sewer Outfall Interceptor Which WSACC Interceptor will the flow ultimately be discharged into: 48-inch material WSACC Name Interceptor What is the WSACC manhole number that the flow will be discharged into? +/- Node 011067 What is the quantity of flow that will be discharged? 1,960 GPD Flow type: ® Domestic 100 % ❑ Commercial % ❑ Industrial % Name of wastewater treatment facility (WWTF) receiving wastewater: ® Rocky River Wastewater Treatment Facility — Permit #NC0036269 ❑ Muddy Creek Wastewater Treatment Facility — Permit #NC0081621 Design drawings of new lines will be submitted to WSACC with the request for acceptance. Drawings can be submitted as a digital file (DWG) or distance and bearing starting with the tap on existing infrastructure. If the new line is to connect directly into a WSACC interceptor, detailed drawings including specification of the tap, will be required before flow acceptance will be provided. Mark Lomax at 704-786-1783, ext. 231, must be notified 48 hours in advance of a connection into a WSACC interceptor. WSACC will inspect connection before, during, and after completion. If construction is not started within two (2) year froin lire date of approval of the flow acceptance for this project, tyre approval is rescinded and a second request and approval will be required for the project. WSACC USE ONLY: DATE: Ii. Current sewer model shows an Interceptor as being surcharged south of the manhole in question. yApproved ❑ Not Approved ❑ Current Sewer Model shows: Su Ct at N C .x4tr is CAME- m ern, t 5f 0 RI) AT NNMII.A.GA vJ CIUMS