Loading...
HomeMy WebLinkAbout20230131 Ver 1_Major Variance_20230114CITY/COUNTY OF DURHAM ORDER GRANTING, UPON CERTAIN CONDITIONS, A REQUEST FOR A VARIANCE FROM THE RIPARIAN BUFFER USE STANDARDS (B2200044) PID: 107858 The Board of Adjustment ("Board") of the City/County of Durham, having conducted a hearing on "1706 Ward Street Riparian Buffer Variance" (Case B2200044) on December 13, 2022 and having considered all written and oral evidence presented at such hearing, hereby determines that the Ordinance requirements for the granting of a variance in this case have been met, and that the variance should be granted upon certain conditions. THE BOARD HEREBY MAKES THE FOLLOWING FINDINGS AND CONCLUSIONS, based on the evidence presented at the public hearing: The proposed use, as described in the application, with such further conditions as may be described below, meetsthe requirements of Section 3.9 of the Unified Development Ordinance, and: 1. Is in harmony with the area and not substantially injurious to the value of properties in the general vicinity; 2. Conforms with all general and special requirements applicable to the use and the General Findings and Review Factors identified in Section 3.9.8A, B, and C; 3. Will not adversely affect the health or safety of the public. IN SUPPORT OF THESE FINDINGS AND CONCLUSIONS, THE BOARD finds as fact that the descriptions and statements of fact set forth in the staff report presented as evidence to the Board are the facts describing the proposed use, surrounding conditions, and Ordinance requirements and the Board adopts by reference and includes in this decision and order all such facts and, in particular, the conclusions in the staff report entitled "Staff Analysis" as if set forth herein. THEREFORE, THE BOARD HEREBY GRANTS THE VARIANCE WITH TH1E CONDITIONS THAT MAY BE SET FORTH BELOW: 1. The improvements shall be substantially consistent with all information submitted to the Board as part of the application 2. Necessary digging will be done by hand-held tools and materials will be hand carried into the site. WRITTEN CONSENT TO CONDITIONS IMPOSED THROUGH A DEVELOPMENT PERMIT N.C. GEN. STAT. § 160D-1403.2 Type of development permit: Variance Case # (B2200044): 1706 Ward Street Riparian Buffer Variance Applicant Information (should mirror the application): Name: Elinor Landess and Katie Loebner Firm: N/A Phone: 704-756-1708 Email: elinor.landess@gmail.com Mailing address: 1706 Ward Street, Durham, NC, 27707 As the applicant for this Case, I am providing my written consent to the following conditions or committed elements (The wording of conditions or text committed elements stated below shall match the language approved by the decision -making body. If committed elements are graphic, the documents that present the graphical committed elements shall be attached to this form or clearly included by reference to a specific set of documents identified below): 1. The improvements shall be substantially consistent with the plans submitted to the Board as part of the application. 2. Necessary digging will be done by hand-held tools and materials will be hand carried into the site. (Applicant's signature and date of execution) (Planning staff signature and date of execution) IN ADDITION, as indicated in Section 3.9.14 of the Ordinance this permit will become null and void in the following cases: 1. If a site plan is not approved within 12 months of the date of permit approval. 2. Where an approved site plan or building permit expires. 3. Where a building permit is not issued within two years of the date of approval, in cases where a site plan is not required. 4. If a substantial violation of the conditions of the permit, as determined by the Planning Director or designee occurs. IN WITNESS WHEREOF, the Board of Adjustment of the City/County of Durham has caused this Minor Special Use Permitto be issued in its name, together with all conditions, as binding on the applicant, and their successors in interest. An appeal of a Board of Adjustment Order can be filed pursuant to procedures noted in the North Carolina General Statutes, Chapter 160D, Sections 406, 1402, and 1405, with the Durham County Superior Court within 30 days (as defined by N.C. Gen. Stat. §160D-1405(d)). IEW Ordered this the 131h day of December, 2022 Staff Planner Clerk Date Mailed 19:0 VARIANCE STAFF REPORT CITY OF DURHAM DURHAM COUNTY 1706 WARD STREET RIPARIAN BUFFER VARIANCE (B2200044) Planning Meeting Date: December 13, 2022 1706 Ward Street Riparian Buffer Reference Name Jurisdiction City Variance (B2200044) A Variance to the riparian buffer protection standards in order to construct a Request porch. Tier Urban Zoning District Residential Urban — 5 (RU-5) Site Characteristics Overlays N/A Site Acreage .69 Acres Elinor Landess and Applicant Submittal Date October 13, 2022 Katie Loebner Location 1706 Ward Street PI D(s) 107858 A. Summary Elinor Landess and Katie Loebner, the owners/applicants, request a variance from the riparian buffer standards. Unified Development Ordinance (UDO) Section 8.5.12 requires any person who wishes to undertake a prohibited use in a riparian buffer apply for a variance. UDO Section 8.5.9C requires that any buildings or other features that require grading and construction shall be set back at least ten feet from the edge of the riparian buffer. The applicants are requesting a variance from UDO Section 8.5.413 in order to construct a screened -in porch attached to the rear of the primary structure; the proposed porch will replace an existing deck at a 1:1 scale. In order to meet the requirements for a riparian buffer variance all requirements found in UDO Section 8.5.12B.3 must be met in addition to the four findings below. This property is located in a Residential Urban — 5 (RU-5) zoning district and in the Urban Development Tier. Summary of Issue None at this time. Recommended Conditions of Approval 1. The improvements shall be substantially consistent with the plans and all information submitted to the Board as part of the application. 2. Necessary digging will be done by hand and materials will be hand carried into the site. Page 1 of 6 B2200044 1706 Ward Street Riparian Buffer Variance Variance Staff Report B. UDO Section 3.14 Variance The Board of Adjustment may vary certain requirements of this Ordinance, in harmony with the general purpose of these regulations, where special conditions applicable to the property in question would make the strict enforcement of the regulations impractical or result in a hardship in making reasonable use of the property. UDO Section 3.14.8 establishes the findings listed below that the Board of Adjustment must make in granting any variance. 1. Unnecessary hardship would result from the strict application of the Ordinance. It shall not be necessary to demonstrate that, in the absence of the variance, no reasonable use can be made of the property. Staff Analysis. According to the Durham County Tax Administration records, the existing single-family dwelling was constructed in 1979, which predates the adoption of the riparian buffer standards within the UDO. It could therefore be argued that the strict application of the Ordinance, and disallowance of the replacement of the existing deck with a porch that does not further encroach into the buffer, could render the owner unable to reasonably utilize the site for the residential uses for which it is zoned. Refer to Attachment 3, Application, for the applicant's response to this finding. 2. The hardship results from conditions that are peculiar to the property, such as location, size, or topography. Hardships resulting from personal circumstances, as well as hardships resulting from conditions that are common to the neighborhood or the general public, may not be the basis for granting a variance. Staff Analysis. The property is 0.69 acres, zoned Residential Urban — 5 (RU-5), and currently has an existing primary structure with a deck attached to the rear of the structure. According to the Durham County Tax Administration records, the existing single-family dwelling was constructed in 1979, which predates the adoption of the riparian buffer standards within the UDO. While the parcel is larger than many of the neighboring properties, the configuration of the lot varies from the rectilinear nature of the surrounding properties; additionally, while the stream flow largely affects the rear of the lots for the parcels to the north (lots which front along James Street and Blount Street), this parcel's orientation towards Ward Street (combined with its unique shape) creates a situation in which the riparian buffer and 10' no -build setback occupies approximately 87% of the subject property (see Attachment 4: Survey). This disproportionally affects the allowable development of this parcel. Refer to Attachment 3, Application, for the applicant's response to this finding. Page 2 of 6 B2200044 1706 Ward Street Riparian Buffer Variance Variance Staff Report 3. The hardship did not result from actions taken by the applicant or the property owner. The act of purchasing property with knowledge that circumstances exist that may justify granting a variance shall not be regarded as a self-created hardship. Staff Analysis. The owner/applicant has not taken any action on this property that imposes a hardship; the subject parcel was purchased in 2016 with the existing conditions in place at that time. The applicant is seeking to replace an existing deck with a screened -in porch at a 1:1 scale. The existing deck is constructed of spaced vinyl planks and, therefore, does not meet the definition of built -upon area (i.e., impervious surface), per North Carolina General Statute (N.C.G.S.143-214.7(b2)). The proposed covered porch will, therefore, increase impervious surface on -site, but the amount of disturbance within the riparian buffer will remain approximately the same. The applicant also states while the deck is slatted, water still pools on the deck due to the small distance between slats. Refer to Attachment 3, Application, for the applicant's response to this finding. 4. The requested variance is consistent with the spirit, purpose, and intent of the Ordinance, such that public safety is secured, and substantial justice achieved. Staff Analysis. The intent of the Ordinance is to promote the health, safety and general welfare of the residents of Durham City and County. In this spirit, the Ordinance provides development standards and, when necessary, aims to prescribe uniformity for specific types of development. The proposal to replace the deck with a screened -in porch of the same size is in keeping with the intent of the Ordinance to achieve substantial justice, as it provides the applicants with a continuation of the existing use of the subject property which was built in accordance with UDO standards at the time of its construction. Refer to Attachment 3, Application, for the applicant's response to this finding. C. UDO Section 8.5.1213.1 Additional Findings a. There are practical difficulties or unnecessary hardships that prevent compliance with the riparian buffer protection requirements. 1. If the applicant complies with the provisions of this section, he/she can secure no reasonable return, nor make reasonable use of, his/her property. Merely proving that the variance would permit a greater profit from the property shall not be considered adequate justification for a variance. Moreover, the variance shall be the minimum possible deviation from the terms of the ordinance shall make reasonable use of the property possible; Page 3 of 6 B2200044 1706 Ward Street Riparian Buffer Variance Variance Staff Report Staff Analysis. The size of the proposed porch will be the same as the existing deck. The existing nonconformity of the site will not be increased from the existing site conditions, which is the minimum possible deviation from the current terms of the Ordinance. 2. The hardship results from application of this section the property rather than from other factors such as deed restrictions or other hardship; Staff Analysis. The hardship results from the location of the existing primary structure, which was established within the riparian buffer before riparian buffer requirements were enacted. 3. The hardship is due to the physical nature of the applicant's property, such as its size, shape, or topography, such that compliance with provisions of this section would not allow reasonable use of the property; Staff Analysis. The existing configuration of the lot, the delineation of the stream, and the built improvements on the property were all in existence at the time of purchase of the property and were in compliance at the time of construction. 4. The applicant did not cause the hardship by knowingly or unknowingly violating this Ordinance; and Staff Analysis. The applicant has not brought the subject property into violation of the ordinance; there have been no unlawful changes to the site conditions since the purchase of the property in 2016. b. The hardship is rare or unique to the applicant's property. Staff Analysis. The existing conditions of the parcel (shape, orientation, and location of the stream throughout), combined with the existing site improvements being constructed prior the adoption of the ordinance, does present a unique hardship that would not apply in the same fashion to the neighboring properties. c. The requested variance is in harmony with the general purpose, spirit and intent of the state riparian buffer protection requirements and/or this section Staff analysis. The variance should not affect wildlife habitats, water quality, or any other environmental concern more than the current conditions of the site, which should not change as a result of the proposed variance request. However, precedent exists for the Board of Adjustment to include a Condition of Approval that would limit the type of disturbance within the riparian buffer or the 10' no -build setback during construction. By conditioning an approval with the restriction that "necessary digging will be done by hand and materials will be hand carried into the site", the proposed porch should not result in an increase in the area of disturbance within the riparian buffer (outside of the minimal disturbance typically associated with the construction of Page 4 of 6 B2200044 1706 Ward Street Riparian Buffer Variance Variance Staff Report a porch). This condition of approval would further limit any environmental concerns regarding disturbance of the riparian buffer and erosion control during the construction of the proposed screened -in porch. Additional restrictions ("Vegetation in undisturbed portions of the buffer shall not be compromised", "At the completion of the project any disturbed area is stabilized with native vegetation", etc.) are also precedented conditions in the Riparian Buffer Protection Standards within the UDO and could further protect the riparian buffer in accordance with the purpose, spirit, and intent of the State/UDO riparian buffer protection requirements. Additionally, per the Stormwater Ordinance, single-family residential sites within the Jordan Lake Basin that are adding less than 2,000 square feet of impervious surface and disturbing less than 1 acre of land are exempt from stormwater review. Given that the proposed screened -in porch would be 10' by 15' in size and the parcel is less than 1 acre, approval of this request should not trigger stormwater review standards. d. In granting the variance, the public safety and welfare have been assured, water quality has been protected, and substantial justice has been done. Staff analysis. The overall proposed improvements to the property should not have any negative effect public safety, welfare, or water quality. D. Notification Staff certifies that letters to property owners and residents within 600 feet of the site and the posting of a sign on the property has been carried out in accordance with UDO Section 3.2.5 of the UDO. In addition, email notice was provided per the Durham Planning Public Notification Service. E. Staff Contact Robin Schultze, 919-560-4137 ext. 28201, or Robin.Schultze@DurhamNC.gov Attachments Attachment 1— Context Map Attachment 2 — Aerial Map Attachment 3 — Application Attachment 4 — Survey Attachment 5 — Proposed Plans F. Possible Motion MOTION TO GRANT APPLICATION WITH CONDITIONS Page 5 of 6 B2200044 1706 Ward Street Riparian Buffer Variance Variance Staff Report I hereby make a motion that case number B2200044, an application for a request for a Variance from riparian buffer standards, on property located at 1706 Ward Street, has successfully met the applicable requirements of the Unified Development Ordinance and is hereby granted subject to the following conditions: The improvements shall be substantially consistent with the plans and all information submitted to the Board as part of the application. Necessary digging will be done by hand and materials will be hand carried into the site. Page 6 of 6 B2200044 —1706 Ward Street Riparian Buffer Variance Context Map Attachment 1: Context Map hr - I :0I „4. t qj y 3 f+ 13 NIL f t ti •t' ter, -A } f f AM I i Attachment 3: Application M:0 Minor Special Use Permit (mSUP), Variance, and Reasonable Accommodation Application CITY OF DURHAM City -County Planning Department DURHAM COUNTY Download and open PDF document file before entering information Planning Application Guide and Submittal Portal: https://dsc.durhamnc.gov/264 Application Questions: BOA@durhamnc.gov 1 919-560-4137 PROJECT INFORMATION: Application Type: ❑ mSUP EVariance ❑ Reasonable Accommodation Site Address:1706 Ward St Total Site Area (in acres): 0.6 Zoning District(s): RU-5 Zoning Overlay(s): none Jurisdiction: ■ City ❑ County ❑ Both Development Tier(s): Urban PIN(s): 0821-22-11-4389 Associated Site Plan Case Number: PID(s): 107858 Current Use(s): residential Proposed Use(s): residential APPLICATION REQUIREMENTSSUBMITTAL) This application is oform of written testimony and is used to provide evidence that the required findings for approval con be mode. The applicant has the burden of proof and must provide sufficient evidence in orderfor the required findings to be mode. ALL EVIDENCE PRESENTED IN RELATION TO EFFECT ON REAL ESTATE VALUE ANDIOR TRAFFIC IMPACTS SHOULD BE PROVIDED BY EXPERT WITNESSES. EVIDENCE PRESENTED BY NON -EXPERT WITNESSES CANNOT BE RELIED UPON BY THE BOARD. G.S 16OD-1402 NOTE: Attendance at the Board of Adjustment hearing is required. Applicants may represent themselves or may be represented by someone oppropriate for quasi-judicial public hearings. Decisions con be oppeoled to Superior Court within 30 days. 1. Documentation of the Pre -submittal Meeting (Required) 4. Floor Plan, Elevations, and Plot Plan or Site Plan, as applicable (Additional supporting documents may be requested by the Case 2. Payment Receipts Planner and/or may be provided by the applicant) 3. For mSUPs: Responses to General Findings and Review Factors (UDO Section 3.9.8A and B), Additional Findings and/or Review Factors (if applicable), and Responses to Limited Use Standards (if applicable) For Variances: Responses to General Findings and Review Factors (UDO Section 3.14.8) For Reasonable Accommodations: Responses to General Findings (UDO Section 3.24) ACKNOWLEDGEMENTS• I, the undersigned, acknowledge that the application is complete and that all information included is accurate to the best of my knowledge. Applications are considered accepted only after they have been determined to be complete according to paragraph 3.2.4 of the Unified Development Ordinance, not upon submission. Owner Applicant Agent (if applicable) Name: Elinor Landess & Katie Loet Elinor Landess & Katie Loeb Firm: Phone: 704-756-1708 704-756-1708 Email: elinor.landess@gmail.com elinor.landess@gmail.com Address: 1706 Ward St, Durham, NC 1706 Ward St, Durham, NC: Digital Signature: � C�_ Date Signed: Form 1054, April 2021 Page 1 of 3 In granting a Minor Special Use Permit, Variance, or Reasonable Accommodation request, the Board of Adjustment may prescribe reasonable and appropriate conditions provided that the conditions are reasonably related to the request. The conditions shall become part of the approval. Violations of any of the conditions shall be treated in the same manner as other violations of the Ordinance. The Board of Adjustment may prescribe whether a reasonable accommodation is granted to the applicant or shall be allowed to pass with transfer of property. Furthermore, Special Use Permits and Variances shall become null and void in any of the following cases (Section 3.9.14 or 3.14.8 of the UDO): All applications: A. If a site plan or architectural review, as applicable, is not approved within 12 months of the date of permit approval. B. If an approved site plan, architectural review application, or building permit expires. C. If a building permit is not issued within two years of the date of approval, in cases where a corresponding site plan or architectural review is not required. In the case of a Variance, also if the Ordinance standard subject to the variance has been amended prior to the issuance of a building permit. D. If a substantial violation of the conditions of the permit, as determined by the Planning Director or designee occurs. The addition of language to the special use permit regarding such voiding shall not be required. Digital Signature: Date Signed: I, Elinor Landess and Katie Loek , hereby petition the Durham Board of Adjustment for a Minor For mSUPs: Special Use Permit to allow use of the property as described in material submitted with this request. Digital Signature: Date Signed: I, Elinor Landess and Katie Loek , hereby petition the Durham Board of Adjustment for a Variance from the literal provisions cited to allow use of the property as described in material submitted with this For Variances: request. Digital Signature: — Date Signed: I, Elinor Landess and Katie Loebner. , do hereby petition the City of For Reasonable Durham/County of Durham for a Reasonable Accommodation to the Unified Development Ordinance provisions described in material submitted with this request to allow use of the property also as described in Accommodations: this request. Digital Signature: Date Signed: RESPONSES REQUIRED (PLACE RESPONSES IN A SEPARATE WORD DOCUMENTFOR SUBMITTAL) 1. Ordinance provision(s) that require an mSUP for this project 2. What is proposed? General Findings: Applications for minor special use permits shall be approved only if the Board of Adjustment finds that the use as proposed, or the use as proposed with conditions, is: 1. In harmony with the area and not substantially injurious to the value of properties in the general vicinity; 2. In conformance with all special requirements applicable to the use; 3. Will not adversely affect the health or safety of the public; and 4. Will adequately address the review factors identified below Minor Special Use Permit Review Factors: The applicant shall demonstrate that the review factors listed below have been Responses: adequately addressed: 1. Circulation: Number and location of access points to the property and the proposed structures and uses, with particular reference to automotive, bicycle, mass transit and pedestrian safety and convenience, traffic flow and control, and access in case of fire or catastrophe. 2. Parking and Loading: Location of off-street parking and loading areas. 3. Service Entrances and Areas: Locations of refuse and service areas with particular reference to ingress and egress of service vehicles. 4. Lighting: Locations of exterior lighting with reference to glare, traffic safety, economic effect and compatibility with other property in the area. 5. Signs: Appropriateness of signs considering location, color, height, size, and design within the context of other property in the area. Form 1054, April 2021 Page 2 of 3 6. Utilities: Location and availability of utilities. 7. Open Spaces: Location of required yards and other open spaces and preservation of existing trees and other natural features 8. Environmental Protection: Preservation of tree coverage, Durham Inventory Sites, floodplain, stream buffers, wetlands, steep slopes, open space, and other natural features, and protection of water quality. 9. Screening, Buffering, and Landscaping: Installation of screening, buffering, fencing, and landscaping where necessary to protect adjacent property. 10. Effect on Adjacent Property: Effects of the proposed use on nearby properties, including, but not limited to, the effects of noise, odor, lighting, and traffic. 11. Compatibility: The level of general compatibility with nearby properties and impacted neighborhoods, including but not limited to the appropriateness of the scale, design, and use in relationship to other properties. 12. Consistency with Policy: Consistency with the Comprehensive Plan and applicable development tier guidelines, overlay purposes, and zoning district intent statements in Article 4, Zoning Districts. 13. Other Factors: Any other factors that the approving authority considers to be appropriate to the property in question. Also address Limited Use Standards, as applicable 1. Ordinance provision(s) from which a variance is requested Variance Responses: 2. What is proposed? 3. What the Ordinance provision(s) require General Findings: The Board of Adjustment must make these findings in order to grant any variance. Burden of Proof: The 1. Unnecessary hardship would result from the strict application of the Ordinance. It shall not be applicant seeking the necessary to demonstrated that, in the absence of the variance, no reasonable used can be variance shall have the made of the property. burden of presenting enti 2. The hardship results from conditions that are peculiar to the property, such as location, size, or to allow evidence sufficienttopography. Hardships resulting from personal circumstances, as well as hardships resulting the Board of Adjustment or from conditions that are common to the neighborhood or the general public, may not be the Governing Body to reach basis for granting a variance. the conclusions set forth 3. The hardship did not result from actions taken by the applicant or the property owner. The act below, as well as the of purchasing property with knowledge that circumstances exist that may justify granting a burden of persuasion on variance shall not be regarded as a self-created hardship. those issues. 4. The requested variance is consistent with the spirit, purpose, and intent of the Ordinance, such that public safety is secured, and substantial justice achieved. General Findings: Applications for Reasonable Accommodations shall be approved only if the Board of Adjustment finds based on competent, material, and substantial evidence, that the proposed accommodation: 1. Will be used by an individual or individuals with a disability or handicap protected under federal law; Reasonable 2. Is "reasonable." An accommodation is reasonable if it will not undermine the legitimate Accommodation purposes and effects of existing zoning regulations, and if it will not impose significant financial Responses: and administrative burdens upon the city or county and/or constitute a substantial or fundamental alteration of the ordinance provisions; 3. Is "necessary." An accommodation is necessary if it will provide direct or meaningful therapeutic amelioration of the effects of the particular disability or handicap, and it will afford handicapped or disabled persons equal opportunity to enjoy and use housing in residential districts in the city or county. Form 1054, April 2021 Page 3 of 3 Elinor Landess & Katie Loebner 1706 Ward St Variance Application 1. Ordinance provision from which a variance is requested: Durham UDO paragraph 8.5.4, Riparian Buffers Protected. 2. What is proposed? We are proposing to build a screened in porch onto the footprint of our existing deck. The deck is made of vinyl and is impervious, so no additional impervious surface will be added. The deck has been on the property at least since 1994 according to arial photos on the Durham GIS map; prior to 1994, the photo quality is too grainy to distinguish features of the house. Our property was built in 1979, many years prior to the riparian buffer ordinance being in place, and much of the property is now included in what is now the riparian buffer zone. This is no fault of ours (we bought the property in 2016) and prevents us from enjoying our property in the same way our neighbors can. 3. What the ordinance provision(s) require. The ordinance requires that building happen outside of the 50 foot riparian buffer and 10 foot no build zone. The intermittent stream that runs through our property is located within the 60 foot riparian buffer + no build zone, so we are requesting a variance from the ordinance. General Findings: The Board of Adjustment must make these findings in order to grant any variance. 1. Unnecessary hardship would result from the strict application of the Ordinance. It shall not be necessary to demonstrated that, in the absence of the variance, no reasonable used can be made of the property. The strict application of the ordinance will prevent us from being able to build the screened in porch onto the existing footprint and enjoy our property like our neighbors are able to. The specifications of the ordinance and the specific layout of our property mean that nearly all of our house is in the riparian buffer/no build zone. 2. The hardship results from conditions that are peculiar to the property, such as location, size, or topography. Hardships resulting from personal circumstances, as well as hardships resulting from conditions that are common to the neighborhood or the general public, may not be the basis for granting a variance. The ordinance was put in place after the property was built (1979) and the conditions of the ordinance and of the property mean that nearly the entire house is in the riparian buffer/no build zone. We cannot bring the existing deck into conformity with the variance because of these conditions, therefore the porch would not be able to either. 3. The hardship did not result from actions taken by the applicant or the property owner. The act of purchasing property with knowledge that circumstances exist that may justify granting a variance shall not be regarded as a self-created hardship. The existing deck needs to be replaced due to the age of the structure and resulting mold/rot. We have also been told that it is not in compliance with current city building codes. The site conditions have not changed since we moved in in 2016. 4. The requested variance is consistent with the spirit, purpose, and intent of the Ordinance, such that public safety is secured, and substantial justice achieved. Because the deck is already impervious and we are building on the existing footprint, no additional impervious surface will be added to our property. Further, there is no other option on the property for where to add a deck because of the conditions of the property and the ordinance. The current deck is 10'x15' and our plan is to build the porch onto the exact footprint of the deck. Note: Our proposal includes a plan for the deck that shows it expanding. This is an old plan that was drawn prior to our permit being denied and learning about the riparian buffer ordinance, but we included it to give a sense of what we're planning to do (minus the expansion by 1 foot of width and one foot of depth). Elinor Landess & Katie Loebner 1706 Ward St Variance Application Additional Findings Specific to Stream Variances per Durham UDO 8.5.12B: 1. There are practical difficulties or unnecessary hardships that prevent compliance with the riparian buffer protection requirements. The following criteria must all be met in order to make such finding: a. If the applicant complies with the provisions of this section, he/she can secure no reasonable return from, nor make reasonable use of, his/her property. Merely proving that the variance would permit a greater profit from the property shall not be considered adequate justification for a variance. Moreover, the variance shall be the minimum possible deviation from the terms of this Ordinance that shall make reasonable use of the property possible, There is no way for us to replace the existing deck (or build anything at all) on the property without a variance because the buffer zone encompasses the entire property. The variance will allow us to replace and modify the existing deck using the exact footprint. Additionally, no impervious surface will be added since the deck is vinyl. b. The hardship results from application of this section to the property rather than from other factors such as deed restrictions or other hardship, The property was drawn and the house built in 1979, long before the stream buffer ordinance was in place. Because of the conditions of the property, the majority of the house and yard are in the buffer/no build zone. c. The hardship is due to the physical nature of the applicant's property, such as its size, shape, or topography, such that compliance with provisions of this section would not allow reasonable use of the property, The property was drawn and the house built in 1979, long before the stream buffer ordinance was in place. Because of the conditions of the property, the majority of the house and yard are in the buffer/no build zone. d. The applicant did not cause the hardship by knowingly or unknowingly violating this Ordinance; and We have not changed the conditions of the property since we purchased it in 2016. e. The hardship is rare or unique to the applicant's property. The property was drawn and the house built in 1979, long before the stream buffer ordinance was in place. Because of the conditions of the property, the majority of the house and yard are in the buffer/no build zone. Elinor Landess & Katie Loebner 1706 Ward St Variance Application 2. The requested variance is in harmony with the general purpose, spirit and intent of the state riparian buffer protection requirements and/or this section; and Because we are proposing building the porch onto the existing footprint of a deck, and no additional impervious surface will be added on the property since the deck is made of vinyl, our request is in harmony with the general purpose, spirit, and intent of the state riparian buffer protection. 3. In granting the variance, the public safety and welfare have been assured, water quality has been protected, and substantial justice has been done. Because the deck is already impervious and we are building on the existing footprint, no additional impervious surface will be added to our property. We are also committed to protecting the health of the stream by taking measures such as installing rain barrels at the end of the downspouts coming off of the porch. Further, there is no other option on the property for anywhere to build anything because of the conditions of the property and the ordinance. The current deck is 10'x15' and our plan is to build the porch onto the exact footprint of the deck. Attachment 4: Survey N SITE Li a w a 0 w 0 0 0 WARD SrRFFT U) w a VICINITY MAP (not to scale or bearing) REFERENCES: PB. 94 PG. 186 PB. 43 PG. 26 PB. 19 PG. 98 PB. 11 PG. 33 DB. 2185 PG. 685 DB. 1232 PG. 13 DB. 2687 PG. 231 DB. 2288 PG. 427 W. G. AUTRY 1708 SIX GABLES ROAD I, William Gregory Autry, certify that this plat was drawn, under my supervision From an actual survey made under my supervision (Deed/Plat recorded in Book 94 Page 186 ) and is in every respect correct to the best of my knowledge and belief ; that the lines not surveyed are indicated as drawn from information found in References as listed ; that the ratio precision as calculated by coordinate method is 1: 16,000+ Witness my original signature, registration number and seal this 13 day of MARCH A-D., 2013 W ,_ � �nW�,_ William Gregory Autry, P.L.S. If 4267 To the best of my knowledge and interpretation (by ,scaling 2008 FEMA maps) A PORTION OF this property is located in a 100 year flood hazard area. --------------- Curve Table Listing --------------- CURVE TABLE # Radius Delta Length Chord Tangent Chord Bearing 1 225.88' 17057' 46" 70.82' 70.53' 35.70' S 54012' 56" E 2 448.26' 15031' 25" 121.45' 121.08' 61.10' N 53015' 54" W WALLACE ST `' MAN \HOLE 021, PO �'�8__2��4\16„ LOT 1 4•o�F`0 GAO � �F•p LOT 2 to' LOT 3 LOT 4 LAND SURVEYOR DURHAM NC. 27712 PHONE/FAX:(919) 477-1423 Lot 1 -Blockk Plot Title FE E. WARD Pb. / Db. 94 Pg. 186 THIS DOCUMENT ORIGINALLY ISSUED AND SEALED BY WILLIAM GREGORY AUTRY, P.L.S. L-4267, ON 03-13-2013. THIS MEDIUM SHALL NOT BE CONSIDERED A CERTIFIED DOCUMENT J / F LOT 1 ; D Pc 30466.58 sq.ft. (0.69942 acres) / I LOT 2 �c I MAN I HOLE I —Iron found 0 Iron set O Mon. O Math Point + Nail x —No true lines cut. Property lines traversed. —This is a class A survey. (No useable horz. Control found within 2,000 —This survey is a representation of conditions existing at this time and is not for recording purposes. —Location of utilities, if shown, ore based on visible evidence or information provided to the surveyor. Location of utilities may vary from shown locations. Additional utilities may exist. Local utility companies should be consulted for information affecting this property. —This survey was done without benefit of a title search which could disclose zoning, restrictive covenants, easements, building setbacks, or other information which could affect this property. —No subsurface or environmental considerations affecting this property have been investigated by surveyor- -This survey is not valid for subsequent owners or transactions. —® copyright by William Gregory Autry Land Surveyor. Reproductions or alterations of any part of this document, without written consent of the surveyor, are prohibited. o I I\ I 0 M III Ills 03 PORdH Dt-1' ij I I I G ems° �� mac%; � I � I ;�>° I Q) 0, I; 25 1 I I I *NOTE: —RIPARIAN BUFFER ADDED TO DRAWING 04-12-2022 —THIS IS NOT A UPDATED SURVEY OR A REVISION —SURVEYOR MAKES NO CLAIMS THIS DRAWING REPRESENTS CURRENT CONDITIONS OF PROPERTY —SURVEY IS NOT VALID FOR SUBSEQUENT OWNERS OR TRANSACTIONS AFTER THE ORIGINAL DATE AND OWNER. *NOTE: —"AE" FLOOD LINE SCALED FROM F.E.M.A. MAPS CLIENT or OWNER : ROSEMARY L. HOLLAND Property Address: 1706 WARD STREET City or Township: DURHAM County: DURHAM State: NC Scale: 1 = 40' Date: MARCH 13, 2013 0' 40' 80, 120' Ordered by: KENDALL PAGE Job # 031313B 6AFETY FIR6T111 {project l)sscr i pt i on: REMOVAL OF EXISTING DECK; CONSTRUCTION OF ALL NEW 16'X11' COVERED, SCREENED PORCH AT 110ro WARD ST., DURHAM, NC 5u i ldsr: Benitez Carpentry & Renovation, Inc. ANTONIO SENITEZ 5510 CARET' PLACE, DURHAM, NC 2-1712 County: DURHAM Telephone: ((Blg) 133-1-413-16 NOTE: Familiarize yourself with Local Codes and all plan pages and specifications to meet Local Codes, NOTE: ALL HEADERS TO SE (2) 2XIOs WITH (1) 2x4 JACKa ENDS PLUS (2) KING STUDS UNLESS NOTED OTHERW16E -ROOF IN ACCORDANCE CHAPTER 'E� WITH CODE -COMPLIANT FIELD FRAMING TO FILL IN SHED SECTIONS, IF NEEDED. Print to Scale: 24x18 FRAMING LUMBER TO SE (UNLESS OTHERWISE SPECIFIED) SOUTHERN PINE #2 WITH MIN Fb OF SOO PSI, or other U.S. Code -Approved lumber, DESIGN LOADS: DEAD 20 PSI LIVE 40 PSI WIND SPEED 115 MPH DRAWING SCH EDU LEI COVER PAGE 11 SITE MAPS 2 CLEAN SITE 3 GENERAL NOTES 4 AS -BUILT EXISTING 5 FLOOR SYSTEM 6 ROOF FRAMING LAYOUT_ 7 FRAMING DIMENSIONS_ 8 ELECTRICAL 9 ELEVATIONS 2 10 REAR ELEVATION 11 DECK REQ - 1 OF 2 12 DECK REQ 2 OF 2 13 1)(98i en Consultant: Kelvin Sell (102) roSS-3229 01/13/2022 co "11�7 LLj T 0 Q m w C3 Q rr w 0 U N N O N 0^, co W T m z Y U Q m >z J U I cn 0 cn E 0 U C? cM c� �� 0E CO ) � o a o 0 06 � �m w w Z J > }' O m aD :3 2 O Y c O U � a) m > � N N > Z Y ro co U J r- LO r- co W E O U � 4S W � M � o rn o Z Q J Ir oLLm N 0 of �a) (f) m 1: 70 -2 Co E M o o J Z i �p o 0 N or W U) 0- CM LU w N 0 Q U) _- U) F co J =O C)U Ir wJp a cn Q w Q a OLd CR W 12cnQ� -4 N woU WSW U)wQ Cc O N QL\2C� M z�~o w� Zd�O _ Dz N r cnd��E Z m � U Y oNLO �x Q m i� J co E (U��"� �a�o CD a Q � ocnz aE--Q N C) L��c ao U ar�QQ m 00 U) 0 U) 3 �° W N wir CD ~ SO m E S O Z N 00 ° 6 m r0 0 �r - E_' J �f O 00° +LO R�Oxp� a r N N — �a�ia°i NN C) C: N +' U — L � 07 C7 (� co 00 3°° a N o a W O OzttCD (0 LLJ p o a� I I 6� � �� LO �O 60 4� E 200.02 Q Q p o 0 0 0 °`" a° t ° J T o d I ,w S 06° 15 1 ER EASEMENT U a 06 r� � am NON-°' + avv �I oo� U-"�a �� ao 5' SAN. SEW cn� z m 3 W `' uCD o'c o�N Oa I w / �= C/L 2 w� c o Z J> >,>tOEf �, v Q - Q - - - o ,�O a p° J U CD z - • o a0 "- O m u> > _ i!] E FAO p ZO�� L c) _ Y Q o N° C/1 0 a �+ O E-WOO / /-- 0 F w O Q �c- CD� / `�Fj s" LJL w #� U > v c v a� +, v �E CO , � - Q o- N o E o a'I� N ti `%p �LOOp ZO �� w O �' cn EaS�a IUI l�\06„�� a) co��°� �_._- 1 v �� ``yZ �� >>ZN ° —, a) � 4 LLJ_ c c .� N 1\N� j1 ��O O W O S U J 7 E Z p p p co zii cDv� c v a �� �� O Y E �� �a w� CO �F. `� / _� \� ENO \ -0 c c �+ n� v v v� N� ° (D E s LLJ EO _ QJ G 6 a� II -�m�._ E J �co N0� CO ' !O o ° ago i a obJD °N� / �co� (AO�� a ` L-t cn o � U� E- d+ O O � H LL]• a Q ���' • _ 01 rN ��o� oao o ��YY CD 0 o W V `�o-0 c� w NLa d� �� O W dO�i�' QV x C o r r= ° t ` o w L V 7� O 2 �2- U C Poo T a � N -° N d U O 2�- ° T + C)O -LLJO °> U r° pi c 3 N Q�C 3/1b 3 Et/Q3S021 ` O r! a J v axi ;v� -00 Q) v o p 0 O.2 O j J N O S O U N J N ��O�om+OL TOO J �Np O LO O Q>NOL �°�?V) (U.0) p >,Q NL ° aNam 0 OW Eo�> o U 0-6 Uzz N oO O CO 0-N- a O-� E CJ6 D_ O>— L O) E a mL 71._ 1vE>O a-Q-Q-a- oo>tL UD_0_0_0_ 0_N Uw CO N -, N•° L� >- �O `� O � Z LONf--00 �� °} � �a v.�+ o7t o 0° LO c o v J O w con0000 w� m0� ° 6+ � ° U� > > 1S S3Wdf z ��r�o���NcoN J^ �� N.`) o av 3 c,U)_0 CO � r L. _ w�dSSSpppp O ax�Uc,cn >�L- C, O `�° 6�ai>z W X W 4C) 0 7-:3 Z Z Q J� n :E mN 5°N a> O LL mN =00 c�NN-0O OO O.N O N U =O 00_ O Ott O ao-0tOO ::::) O U ZH J H N Z H a) �m Jaa I I I I ^U, m W 7 m o CU O J Z [I-- �p N L, O O T W The Importance Of A Clean Jobsite — Will Johnson Building Company Page 1 of 4 The Importance Of A Clean Jobsite — Will Johnson Building Company ' Y�inM'0'N1 9f 9MUE O F A C L E A N• JOB SITE April 4, 2014 Construction is messy, there is just no getting around it. No matter what it is you're building, what system, what materials, there is always a residual mess that is created after the process finishes. This is true of just about every phase of a typical construction project. Consider the site clearing and prep; all of the topsoil is removed, the stumps pulled from the ground, and the underbrush cleared resulting in a nice space for digging your foundation, but all of that debris has to be taken care of. Framing: raw materials are cut to fit their spaces, but the leftover scraps have to be handled. Drywall ... you know what a mess that can be. The end result of all this mess is a great thing, but the problem many contractors run into is not handling the leftover mess every day. Creating a clean jobsite will benefit you in three major ways: happier clients, improved efficiency, and increased likelihood of contact from potential clients who saw your work in progress. First, let's consider the effects of and how a messy jobsite makes your clients feel. Especially if we are talking about remodeling inside their existing home! Keeping a clients home neat and tidy is a simple courtesy that must be extended if you want to maintain a good relationship throughout the project. Additionally, a messy jobsite is the quickest way to ruin an otherwise excellent walkthrough with a client. From https:Hwilljohnsonbuilding.COM/journal-1/2017/8/9/the-importance-of-a-clean jobsite The Importance Of A Clean Jobsite — Will Johnson Building Company 6/18/2018 Page 4 of 4 7 r YourG site i om- on a ob interview for you every day, itJeohnsor�' '�II�'Ing so mac sure it looks ready for that interview. So, how do you go about achieving a cleaner jobsite? Start with yourself. If you happen to create trash or debris on a jobsite, make sure you are setting a good example by putting it where it belongs. I would also from time to time, take out a broom and clean up other people's messes on the site yourself. The impression that will leave on others who see the boss cleaning up is worth the effort and will pay dividends. Second, before a project starts, review your expectations with all of the tradesmen involved so they know you expect a clean jobsite after they finish every day. Last, at the end of meetings you have on site with your employees or tradesmen, remind them about the importance of a clean jobsite. f VGbV Previous 1)0N'T PO116HT TIIE GARAGE: DOOR \cst THREE COMMON ExTERIOR DESIGN ERRORS & HOW TO AVOID TI-IENI Home About Gallery Services Our Process journal Contact Page 2 of 4 �q1 tit •u 'tion is es, y zhci,js ust no etting around it. No matter what VV I�l ,�o�insonr�ut�YC�lI1g C,U'inpan� 000 it is you're building, what system, what materials, there is always a residual mess that is created after the process finishes. This is true of just about every phase of a typical construction project. Consider the site clearing and prep; all of the topsoil is removed, the stumps pulled from the ground, and the underbrush cleared resulting in a nice space for digging your foundation, but all of that debris has to be taken care of. Framing: raw materials are cut to fit their spaces, but the leftover scraps have to be handled. Drywall...you know what a mess that can be. The end result of all this mess is a great thing, but the problem many contractors run into is not handling the leftover mess every day. Creating a clean jobsite will benefit you in three major- ways: happier clients, improved efficiency, and increased likelihood of contact from potential clients who saw your work in progress. First, let's consider the effects of and how a messy jobsite makes your clients feel. Especially if we are talking about remodeling inside their existing home! Keeping a clients home neat and tidy is a simple courtesy that must be extended if you want to maintain a good relationship throughout the project. Additionally, a messy jobsite is the quickest way to ruin an otherwise excellent walkthrough with a client. From experience, I have found that clients are much more likely to criticize or find fault in a project if the jobsite is messy. This is very apparent if that mess is garbage. And we should distinguish between garbage and construction debris. Construction debris are those pieces of scrap lumber or drywall left over at the end of the day. Garbage is your lunch paper and napkins. Garbage should be thrown away immediately, not at https://willjohnsonbuiIding.com/journal-1/2017/8/9/the-importance-of-a-clean-jobsite 6/18/2018 w 1— co The Importance Of A Clean Jobsite — Will Johnson Building Company Page 3 of 4 M Z a w J f the da K" the ite clean and your clients will treat you like W CO i �o`�inson uiMVn,g Uompany • • • C15 the professional you are. Q 10- A clean jobsite is an efficient jobsite. Is it easier to work in a clean space, or a cluttered space? By keeping your project site in good order and clear of debris, you will find tasks not only happen faster, but with improved quality. You don't like to work with asphalt shingle scraps lying all over your desk do you? Why would a siding contractor or grader want to? Also, remodeling projects in particular can be very detail oriented. Remembering where _you need blocking in the wall, where chases go, where the new plumbing drops go are easy to lose track of if the site is messy. The attractiveness of a clean jobsite cannot be overstated. Consider the following scenarios: A potential client drives by a house under construction with Tyvcc paper flapping in the wind, garbage lying around, and lumber scraps strewn about the site, versus, a spotless site with everything in its place. Which site is a prospect more likely to take an interest in? A clean jobsite translates into a profession builder or remodeler in the mind of a prospect. Not convinced? Who is more likely to win a job interview, the person who looks like he just got out of bed S minutes ago and didn't comb his hair, or the one who shoNys up put https://wilijohnsonbuilding.com/journal-1/2017/8/9/the-importance-of-a-clean jobsite 6/18/2018 N N 0 N 0^, co W T m Z Y U Q m 2 ZZ J U Cc M cn 0 cn E 0 C C? CM C) co E w (0 00 (0 @) 0 0 0 0 06 t�:, N m 0) w w co C Z J '> 0 Y C 0 U � Q' a> 00 C ( N > Z Y CZ C00 U ti LO r- w r MD •01 ❑ V1 dS ca NO • � !r L (A (n 0 U i Q� E 0 U 0) E � O M � J °' 0 rn o M z Q w c s OLLm N a o Iv co ^U) W 7 U o ZIr-- L Cfl O CV O T W CONSTRUCTION 1. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. FURTHERMORE CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, AND SAFETY ON SITE. NOTIFYJDS CONSULTING & DESIGN, PLLC IMMEDIATELY IF DISCREPANCIES ON PLAN EXIST. 2. ALL INTERIORAND EXTERIOR BEARING HEADERS TO BE MINIMUM (2) 2x6 #2 SPF WITH (1)JACK AND (1) KING STUD AT EACH END U.N.O. 3. ALL ENGINEERED WOOD PRODUCTS (LVL, PSL, LSL, ETC.) SHALL BE INSTALLED WITH CONNECTIONS PER MANUFACTURER SPECIFICATIONS. 4. ALL STEEL BEAMS TO BE SUPPORTED AT EACH END WITH A MIN. BEARING LENGTH OF3112"AND FULL FLANGE WIDTH. BEAMS MUST BE ATTACHED AT EACH END WITH A MINIMUM OF FOUR 16d NAILS OR TWO 1i2" x 4" LAG SCREWS U.N.O. 5. ALL BEAMS TO BE CONTINUOUSLY SUPPORTED LATERALLY AND SHALL BEAR FULL WIDTH ON THE SUPPORTING WALLS OR COLUMNS INDICATED WITH A MINIMUM OF THREE STUDS U.N.O. 6. SOLID BLOCKING TO BE PROVIDED AT ALL POINT LOADS THROUGH FLOOR LEVELS TO THE FOUNDATION OR TO OTHER STRUCTURAL COMPONENTS. 7. ENGINEERED WOOD FLOOR SYSTEMS AND ROOF TRUSS SYSTEMS TO BE PROVIDED FOR REVIEW AND COORDINATED WITH THE ENGINEER OF RECORD. INSTALLATION TO BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ROOF TRUSS DRAWINGS TO BE SIGNED AND SEALED BY THE MANUFACTURER AND REVIEWED BY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. 8. STEEL FLITCH BEAMS TO BE BOLTED TOGETHER USING (2) ROWS OF 1?2" DIAM. BOLTS (ASTM307) WITH WASHERS PLACED UNDER THE THREADED END OF THE BOLT. BOLTS TO BE SPACED AT 24" o.c. (MAX), AND STAGGERED TOP AND BOTTOM OF BEAM (2" EDGE DISTANCE), WITH TWO BOLTS TO BE LOCATED AT 6" FROM EACH END OF FLITCH BEAM. 9. BRICK LINTELS TO BE 3 112 x 3 112 x 114 STEEL ANGLE FOR UP TO 6'-0" SPAN AND 6 x 4 x 5116 STEEL ANGLE FOR SPANS GREATER THAN 6'-0" AND UP TO 10'-0" U.N.O. 10. BRICK LINTELS AT SLOPED AREAS TO BE 4 x3 1:2 x 1:4 STEEL ANGLE WITH 16d NAILS IN 3116" HOLES IN 4" ANGLE LEG AT 12" o.c. TO TRIPLE RAFTER. WHEN THE SLOPE EXCEEDS 4:12 A MINIMUM OF 3 x 3 x 1A PLATES SHALL BE WELDED AT 24" o.c. ALONG THE STEEL ANGLE. 11. ATTACH PORCH COLUMNS TO SLABIFDN WALL USING ABA -OR- ABE SIMPSON POST BASES TO FIT COLUMN SIZES CALLED ON PLAN -OR-ANY OTHER COLUMN CONNECTION WITH 500# UPLIFT. 11. ATTACH PORCH COLUMNS TO UPPER PORCH BANDS USING AC -OR- BC SIMPSON POST CAPS TO FIT COLUMN SIZES GALLED ON PLAN -OR-ANY OTHER COLUMN CONNECTION WITH 500# UPLIFT. 12. ALL METAL HANGERS, STRAPS,AND HOLD-DOWNS TO BE SIMPSON STRONG TIE OR EOUIV. ROOF SYSTEM STRUCTURAL ROOF NOTES 1. FRAMING SHALL BE #2 SPF OR BETTER U.N.O. 2. PROVIDE 2x4 COLLAR TIES AT 48" o.c. AT UPPER THIRD OF RAFTERS U.N.D. ON PLAN. 3. FUR RIDGES FOR FULL RAFTER CONTACT 4. PROVIDE CONTINUOUS BLOCKING THROUGH STRUCTURE FOR ALL POINT LOADS. S. DENOTES OVERFRAMED AREA 6. MIN.7;'16" OSS ROOF SHEATHING PROVIDE 2x4 RAFTER TIES AT 16" o.c. AT 45" BETWEEN RAFTERS AND CEILING JOISTS. USE (4) 16d NAILS AT EACH CONNECTION. RAFTER TIES MAY BE SPACED AT 48" ox. AT LOCATIONS WHERE NO KNEE WALLS ARE INSTALLED. 11 1. 1.INTERIOR;'TRIMMED FRAMING LUMBERSHALL BE #2 SPRUCE PINE FIR (SPF) WITH THE FOLLOWING DESIGN PROPERTIES: Fb=875PSI Fv=70PSI E=1AE6PSI 2. FRAMING LUMBER EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND, CONCRETE, OR MASONRY SHALL BE PRESSURE TREATED #2 SOUTHERN YELLOW PINE (SYP) WITH THE FOLLOWING DESIGN PROPERTIES: Fb=975PS1 Fv=95PS1 E=1.6EGPS1 3. LVL STRUCTURAL MEMBERS TO BE LAMINATED VENEER LUMBER WITH THE FOLLOWING MINIMUMDESIGN PROPERTIES: Fb=2600PS1 Fv=285PS1 E=1.9E6PS1 4. PSL STRUCTURAL MEMBERS TO BE PARALELL STRAND LUMBER WITH THE FOLLOWING MINIMUMDESIGN PROPERTIES: Fb=290OPS1 Fv=29OPS1 E=2.OE6PS1 5. LSL STRUCTURAL MEMBERS TO BE LAMINATED STRAND LUMBER WITH THE FOLLOWING MINIMUMDESIGN PROPERTIES: Fb=225OPS1 Fv=40OPS1 E=1.55E6PS1 6. STRUCTURAL STEEL WIDE FLANGE BEAMS SHALL CONFORMTOASTMA36. Fy=50 KSI 7. REBAR SHALL BE DEFORMED STEEL CONFORMING TO ASTM A615 GRADE 60. S. SEE TABLE R602.3(1) FOR STRUCTURAL MEMBER FASTENING REQUIREMENTS. 9. POURED CONCRETE TO BE MINIMUM0000 PSI AT 28 DAYS. MATERIALS USED TO PRODUCE CONCRETE SHALL COMPLY WITH THE APPLICABLE STANDARDS LISTED IN AC1318 OR ASTM C 1157. 10. CONCRETE LOCATED PER TABLE R301.2(1) SHALL BE AIR ENTRAINED PER TABLE R402.2. 11. MASONRY UNITS SHALL CONFORM TO ACI 5301ASCE 5+7MS 402 AND MORTAR SHALL COMPLY WITH ASTM C 270. STRUCTURAL ROOF TRUSS NOTES 1. FRAMING SHALL BE #2 SPF OR BETTER U.N.O. 2. PROVIDE CONTINUOUS BLOCKING THROUGH STRUCTURE FOR ALL POINT LOA D S . 3. DENOTES OVERFRAMED AREA 4. MIN. 716" OSB ROOF SHEATHING 5. TRUSS LAYOUT AND PLACEMENT BY MA NU FACTURERTO COINCIDE WITH THE SUPPORT LOCATIONS SHOWN. TRUSS PROFILES SHALL BE SEALED BY THE TRUSS MANUFACTURER. TRUSS PLANS SHALL BE PROVIDED FOR REVIEW AND COORDINATED WITH THE ENGINEER OF RECORD AS REOUIRED BY THE BUILDING CODE OFFICIALS. INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. DESIGN LOADS LIVE LOAD TABLE R301.5 (PSF) DWELLING UNITS 40 SLEEPING ROOMS 30 ATTICS WITH STORAGE 20 ATTICS WITHOUT STORAGE 10 ROOF SNOW 20 STAIRS 40 DECKS 40 EXTERIOR BALCONIES 60 PASSENGER VEHICLE GARAGES 50 FIRE ESCAPES 40 GUARDRAILS AND HANDRAILS 200 TABLE R301.2(4) -DESIGN POSITIVE AND NEGATIVE PRESSURE FOR DOORS AND WINDOW FORA MEAN ROOF HEIGHT OF 35 FEET OR LESS SHALL BE 25 PSF TABLE R301.2(2)-COMPONENTAND CLADDING LOADS FORA BUILDING LOCATED IN EXPOSURE B ROOF VALUES BOTH POSITIVE AND NEGATIVE SHALL BE DESIGNED BASED ON ROOF PITCHES AND MEAN ROOF HEIGHT AS FOLLOWS: MEAN ROOF HEIGHT ROOF PITCH 0.30 FT 35 FT 40 FT 0: 12 TO 2.25:12 45.4 PSF 47.7 PSF 49.5 PSF 2.25:12 TO7:12 04.8 PSF 36.5 PSF 37.9 PSF 7:12 TO 12:12 21.0 PSF 22.1 PSF 22.9 PSF WALL CLADDING SHALL BE DESIGNED FOR A 24.1 PSF POSITIVE AND NEGATIVE PRESSURE 1. MINIMUM ALLOWABLE SOIL BEARING CAPACITY IS ASSUMED TO BE 2000 PSF. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY SOIL BEARING CAPACITY IF UNSATISFACTORY CONDITIONS EXIST. 2. CONCRETE AND MASONRY FOUNDATION WALLS TO BE SELECTED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION R404 OR IN ACCORDANCE WITH AC1318, NCMA TR68-A. ORACI 5301ASCE 5;TMS 402. 3. MASONRY AND POURED CONCRETE WALL REINFORCEMENT TO BE IN ACCORDANCE WITH TABLES R404.1.1 (1 THROUGH 4) OF THE NORTH CAROLINA RESIDENTIAL CODE. A. PER R404.1.3, TABLES ASSUME THAT WALLS HAVE PERMANENT LATERAL SUPPORT AT THE TOP AND BOTTOM B. WALL REINFORCING SHALL BE PLACED ACCORDING TO FOOTNOTE (c) OF THE TABLES (REINFORCING IS NOT CENTERED IN WALL). C. FOUNDATION DRAINS ARE ASSUMED AT ALL WALLS PER R405. 4. WOOD SILL PLATES TO BE ANCHORED TO THE FOUNDATION WITH 112" ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT SPACED A MAXIMUM OF 6'-0" o.c.(3'-0" FOR BASEMENT WALLS) AND WITHIN 12" FROM THE ENDS OF EACH PLATE SECTION. INSTALL MIN. (2) ANCHOR BOLTS PER SECTION. 5. THE UNSUPPORTED HEIGHT OF SOLID MASONRY PIERS SHALL NOT EXCEED TEN TIMES THEIR LEAST DIMENSION . UNFILLED HOLLOW PIERS MAYBE USED IF THE UNSUPPORTED HEIGHT IS NOT MORE THAN FOUR TIMES THEIR LEAST DIMENSION. G. CENTERS OF PIERS TO BEAR IN THE MIDDLE THIRD OF THE FOOTINGS, AND GIRDERS SHALL CENTER IN THE MIDDLE THIRD OF THE PIERS. 7. ALL FOOTINGS TO HAVE MINIMUM 2" PROJECTION ON EACH SIDE OF FOUNDATION WALLS. ROOF TRUSS SYSTEM (IF USED) TRUSS LAYDUTAND PLACEMENT BY MANUFACTURERTO COINCIDE WITH THE SUPPORT LOCATIONS SHOWN. TRUSS PROFILES SHALL BE SEALED BY THE TRUSS MANUFACTURER. TRUSS PLANS SHALL BE PROVIDED FOR REVIEW AND COORDINATED WITH THE ENGINEER OF RECORD AS REOUIRED BYTHE BUILDING CODE OFFICIALS. INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. UPLFrNOM- 1. NFTR TO PRDVME REQUIRED UPLFT CONNECTION, Z PROVIDE HZ$A OR EOUNALENT AT EACH RAFTER TO TOP PLATE CMIECMM (UNO) AT OVER -FRAMED AREAS. �TtU'r�hid+:: �yl:+l Cfi+l3�d:1:7: 40h; 'I ABBREVIATIONS CANT CANTILEVER GONG CONCRETE CONT CONTINUOUS DEL DOUBLE DIAM DIAMETER DJ DOUBLE JOIST DR DOUBLE RAFTER DT DOUBLE TRUSS DSP DOUBLE STUD POCKET EA EACH EE EACH END FL PT FLAT PLATE FTG FOOTING HGR HANGER JS JACK STUD COLUMN KS KING STUD COLUMN LVL LAMINATED VENEER LUMBER MFTR MANUFACTURER NTS NOT TO SCALE OC ON CENTER PT PRESSURE TREATED RS RAFTER SUPPORT SC STUD COLUMN SJ SINGLE JOIST SP STUD POCKET TJ TRIPLE JOIST TR TRIPLE RAFTER TYP TYPICAL UNO UNLESS NOTED OTHERWISE xi EXTRA JOIST BALLOON WALL FRAMING SCHEDULE: 100 MPH FRAMING MEMBER SIZE MAX HEIGHT (PLATE TO PLATE) 2x4 ;uj 16" o.c. 10' - 0" 2x4 L 12" o.c. 12'-0" 2x6 L 16" o.c. 151.0.. 2% rk 12" o.c. 17' - 9" 2x8 L 16" o.c. 19' - 0" 2x8 rd) 12" o.c 22' - 0" (2) 2x4 ;a 16" o.c. 14' - 6" (2) 2x4 tq,' 12" o.c. 17' - 0" (2)2x6 q, IS" o.c. 21' -6" (2) 2x6 to 12" o.c. 25' - 0" (2)2x8L_ IS" o.c. 27' -0" (2) 2x8 (a' 12" o.c 31. - 0" '=ALL HEIGHTS ARE MEASURED SUBFLOORTO TOP OF WALL PLATE. "WHEN SPLIT FRAMED WALLS ARE USED FOR HEIGHTS OVER 12'THE CONTRACTOR SHALL ADD MIN. 6' OF CS16 COIL STRAPPING (FULLY NAILED) CENTERED OVER THE WALL BREAK. "FINGER JOINTED MEMBERS MAY BE USED FOR CONTINUOUS HEIGHTS WHERE TRADITIONALLY MILLED LUMBER LENGTHS ARE LIMITED. I STRUCTURAL FRAMING NOTES 1. ALL FRAMING TO BE #2 SPF MINIMUM. 2. ALL BEARING HEADERS TO BE (2) 2"x 6" SUPPORTED WI MIN. (1) JACK AND (1) KING EACH END U.NO. 3. ALL NON BEARING HEADERS TO BE (2)2"x4' U.NO. 4. PROVIDE CONTINOUS BLOCKING THROUGH STRUCTURE FORALL POINT LOADS. 6. ALL HANGERS AND CONNECTORS SPEC'D ARE TO BE SIMPSON STRONG TIE OR EQUIVALENT. 6. ALL BEAMS SPEC'D ARE MINIMUM SIZES ONLY. LARGER MEMBERS MAY SUBSTITUTED AS NEEDED FOR EASE OF CONSTRUCTION. 7. ALL EXTERIOR WALLS TO BE FULLY SHEATHED WITH 7116" OSB 8. FRONT PORCH COLUMNS TO BE MIN. 4X4 PT ATTACHED AT TOP AND BOTTOM USING SIMPSON (OR EQUIV) COLUMN BASE OR SST A24 BRACKETS. TRIM OUT PER BUILDER, 9. REAR PORCH COLUMNS TO BE MIN. 4X4 PT ATTACHED AT BOTTOM USING SIMPSON (OR EQUIV) ABA44 AND AT TOP USING CS 16 STRAPPING (12" MIN.) TO PORCH HEADERIBAND. 10. WHEN A 4 PLY LVL IS USED ATTACH WITH (1) 1M" 0 BOLT 12" O.C. STAGGERED TOP AND BOTTOM, 1 112" MIN. FROM ENDS. ALERNATE ATTACHMENT EQUIVALENT METHOD MAY BE USED SUCH AS SIDS OR TRUSSLOK SCREWS ( SEE MANUFACTURERS SPECIFICATIONS) R602.10 Wall braciijg, Buildinas, and portions thereof, shall be braked in accordance vAth one car more of the foll&xing sections usincg bracincg materials and methads complying tiAfll Section R6, 2.10.1 and load path detailing in accordance vvithl Section R602.1 a.4 1. Isclated panel Bracing in Accordance with Section R602.10 2. 2. C-O t [ILIDLIS sheathing in accordance -vdth Section R602.10.3: 3- Enginaered design in accordance vpith Section R602.10 5: 4. 2015 �'nternatiunar Code -'IRC), Section RI 132 10 or (Designer's Choice) 5. 3R-192 as published b, .APA. The Engineered Wood P�ssociatiori vJth limitations indicated in this dOCI.i lent. .'e','here a building or portion thereof does rol comply vdth Section R502 10 2_ R602.103. or R802.103.4. those lanrtions shall be designed and constrL,Cted in accordance vvitl7 Section R,51,12.10.:5. R602.10.1 Bracing materials and methods, materials and rnethods shall comply with Table RFA2'_10-1 _ Source: 2018 North Carolina State Building Code: Residential Code U) LU I-_ CO 0 a LU LLI W QW 0- N N O N 0^, co W T m z Y U i (13 Q m LU >z v5 J U (/) Cn E 0 U C? cM cts E 00 CO CO N w (.0 OC) p 06 t�. r-- m Z J > } O m a� = O Y U) D_ 2i C O U � Q N m � N N > z Y ro c co U J I- LO r- co WD .;A N V • a) (A i V L U M � o W O Z Q J CC O W m N \ T_ O c U U) m W 70 -2 Co E MU o J z r-- L �O O C) N Or W C3 Z M w ' ^ J W Lj , D Existing 151x1O1 Deck to Ch be removed completely. J 0 521-57/s'� a Q N 1 o N N O- � - I - I - -1 - I - J -�I Y v O MM SC13 3 -O° x 31-OII J Z > >, 0 2 -S U I cn 0 cn E Kitchen = 0 U M cz N OCO ao `b E 6� a)@� a o 0 06 � r-- m z J > } O m a� 2 O Y U 2i c O U � O M (1) cz � Q (� > N 2>z— O Y J U i dJ - .� r LO c� J co 6� bJD 0 N cz V �7 bD = raw II II II II N� � L II II 0 11 II i E Q� 0 33'--1 3/32" lro'-10 13/32" U co lo O ce 0 rn a > z Q J CC EXISTING HOUSE DEC�G � 0 " m ,AND E m SCALE. 1/4" = V-O" U m N EXISTING70 � 2 E cacz U o PIERS 4 GIRDER and FLOOR SYSTEM FOLLOW6 i o z N o O r W I Top Mount/Flush Girder II (2) 2xlO Fig. AMIOB.IN Appendix M ; I I I I ' I ' I I I I + 11 I I 11 III 71 ' III I I I II I I III i 1 + 11 II II II III II ' 11 1 II I II I II III I _ II II II II II II II II II , II II I r II II II II II II II II II , II II II II II II II II ' II II 1'- i✓ II II II + II II II II II II ' II II 7� II II II II II II II II II I I , 1 -!y�II II II 2)II 2 1II PTO 1/16I1-2II -O 9/32 II II II II II II II II II , II II , j II II II II II II ' II 11 II , II II II II II � _ II --'I II ' III Ti- II , II III_ -il---ll------L---IL---V- I-'•'I--'''-_'----11---11-- ' YI it II II I II III II ' II' II ' II , II III I 'I I I I I I - IT - ' l l �id� `i'fount,IDro�-J,�ed c�irder;l 2X10 PT FLOOR/ �JfOIS+ ;; ;; ;; ;; ;; (2) FAO Fig; -I AMI04.I(2)I MAX. 16" O.C. iT I P,/\/TS � 11 II II II 11 %appendix �� APPLY 5/4" I II II II II ' II II II , II II PT DECKING...-f WITH y , WITH NO CHAP. y II II II II II II ' II II II , II II , y II II II II II II ' II II II , II II , II II II II II II ' II II II II II 1L _ _ 1L _ _ 1L _ _ 1L _ I_ 1L _ _ 1L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Tl: - > > >> > »> 'll»»-->- -----« - - - - - 1paaaaaa+++++aaaaa++++++aaaaa+++++++++++++++++++++++++++++++++++ ++++++++ += ' - - - YS roll 1, 1 i II oil 1 1; ,I 1 I, I, 1, 1' 1 + + + + + + + + + + + + + + + + + + + + + + - - + + + + + + - + + + + + + - + a + 1' 1 1 I, III 1' 1 1 I, III ,I 1 1 I, III ,I 1 1 1, III ,I 1 1 I, III �- - - - - - - - - - - - �-� �-- - - - - - - - - L-- - - - ------------ - - - - y - - - - - - - = - - - - - - - + + + + - - - - 7 - Lj - - - - - - - - - - E13 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ SCREENED FORCH ADDITION FLOOR SYSTEM SCALE. 1/4" = 1'—OII W M cr cr w C� o a N N O N O ri II Y v cz T m LLI Z> Cz -1 U I cn 0 cn E O U C C7 C7 E 0) W Cfl 0 C SO 0 ti t 0) Lj LLI m Z J > LU Y vJ '�'^^^�^ LL c c C O U � Q' a� CO cz (1) N > .r>Z Y cz c 00 U i` u7 i` W NO N 0 U (A W � L�1■� ra) ( ■ L. Q� E O U W � O i` M � J °' O rn o O LL m N a O E a) U) m 70 (n cis co U o zIr-- L, �p O N O T W NEW SCREENED FORCH ROOF (2) 2xl2 Ridge -\ SCREENED PORCH ADDiTiON - ROOD SCALE: 1/4" = 1'-0" H Co J� j�i� j j� � J� j j� ( FRS--'tI I II G AND UPLIFT DETf--'tILS T � Z_ W � � 0 Q Q 0- W 0 These Notes may apply to more than just this page: 0= Foundation Notes: J > 1. Assumed soil load bearing 0 a capacity = 2000 PSF Q 2, Minimum 28 day f ' c of concrete = N 3000 P81 _ N 3, Foundations to be built in ai accordance with NCRC 2018, CH 4 _� �� Y - r M,y W L GCC13 C Wood Deck Notes: w z 1. All lumber to be pressure treated U Co SYP No, 2 or better, v) Ir o U) 1&" O.C. (T1'P.) 2, Band attachments to be installed per NCRC 2018, Appendix M (AM 0 104,1 (1) ) OR (1) 3/8" x 3 5/8" N N LedgerLoks 6" o, c, CZ o o E 3. Install lateral bracing or embed a Co CO posts per AMIO9.1 0 SO o o 4, Install handrails per AM 111,1 w ui 2x10 Flat 5, Max Post Heights per AM 108,1 Z J > 0 ro, Stair Stringers per AM 110,1 c Y 0 U � Screened in and Covered Porch Notes: — Q m a) CZ 'z N 1, All wood deck notes apply, a) 2, Posts to be attached to footings, Y Z Co Co slab or CMU piers using A5U44 orLO ASU66 post base (or applicable size) Co OR (2) Simpson GAi clips Attach all rafters to headers w/ H2.5a clips, _ 3, Uplift for posts to headers may be either (2) Simpson LCE4, .a) (2) Simpson GAI clips with 3: long *9 C screwws or (2) 1/4" diameter, 5" long a LedgerLoks driven at a 45° degree angle, 1 to each side of posts or notched 50ia width w/ (2) 1/4" diameter ' }' cn thru or lag bolts, 4, Uplift for posts to floor framing 0 V may be either (2)Simpson GAI clips with 3" long 013 screws or (2) 1/4" diameter, 5" long LedgerLoks driven at a 45" degree angle to each side, Roof Framing Notes: E Q� 0 1, All roof framing shall be in accordance with NCRC 2018 CH S, 0) 2, All lumber to be pressure treated O Co SPF OR SYP No, 2 or beter J unless specified otherwise, (D > 3. Sheath with 1/16" OSB w' 8d nails }' LU Z x LU Q J cc): Ir at 6" o.c. edge and 12" o.c. field. o " o 4, Install 24" long strapping m at 32" on center. N 70 cn E Z U o J Z L �p O 0 N Or W +„ ho +„ +�+ 6 Handrails nad guards In 4x4 PT Posts Max 4' O.G.-accodance with AMIII.I (TYPJ supporting (2) 2x10 Roof beams, ��. Screen Door opens in bearing on (2) 2x10 FJs with \ +�+ m \y w uplift supports per notes. n _ - - - - - 1W ❑ ❑ n u, Stairs in accordance with AMI10.1 and Flours AMIII.I SCALE. 3/1ro" = 1'-0" FRAMING AND UPLIFT DETAILS ON NEXT PAGE. U) z co z w w Q z_ c N N O O N T co II pp T QD Y U co co m �2t >Z > J U U U) E N 0 C7 ap OC) cM CO r-- 0 U W E i� O m z J > } O m a) = O Y U m 7;; c O U � a) m > � N > z — Yro cW co U J I- LO r- co bJD W V • a L/7 V i Q� E o U � 4S E O � M � o rn o z Q J Ir O W m aNi U) T- O m U70 m Cn -2 Co E MU o L CD O 0 CV Or W 5 � --------- ro 11 I I I I I I I I I I r — — I � 11 I I I I SCREENED FORCH ADDITION - SUGGESTED ELECTRICAL 6G4LE= 1/2" = V-O" IF i EaU IRED, FROV IDE ELECTRICAL TO MEET LOCAL CODE. J Q U M w J W W 0 Q n CV CV O - CV O -' T C'7 II m T � Y U N co T m S Jco >Z U U U) E 0 U M cM W E ap CC)co CO CU M O C p 06 t�. t�, m z J > } O m a� = O Y U) m c O U � a) m (1) CV N > z Y ro c co U J r Lo r` ao bJD 0 N V dA �7 • � = al (A V i Q� E o U M 4S E M � o rn o `V z Q J Ir O W m aNi U O E a> (f) m (3) 70 Cn -2 co E M U o J z I- L Cp O 0 CV Or W APPENDIX M WOOD DECKS This appendix is a North Carolina addition and not part of the 2015 Intemational Residential Code. There will be no underlined text. (The provisions contained in this appendix are adopted as part of this code.) SECTION AM101 GENERAL AM101.1 General. A deck is an exposed exterior wood floor structure that is permitted to be attached to the structure or freestanding. Roofed porches (open or screened -in) are per- mitted to be constructed using these provisions. AM101.2 Deck design. Computer deck design programs are permitted to be accepted by the code official. SECTION AM102 FOOTINGS AM102.1 Footings. Support posts shall be supported by a minimum footing in accordance with Figure AM102.1(1) and Table AM102.1. Minimum footing depth shall be 12 inches (305 mm) below finished grade in accordance with Section R403.1.4. Tributary area is calculated as shown in Figure AM102.1(2). RfC 16.. 4ST O�yST4C •. k �4 Q I � e FIGURE AM102.1(1) SUPPORT POST FOOTING TABLE AM102.1 FOOTING TABLE', b,, SIZE (inches) TRIBUTARY AREA (square feet) THICKNESS (inches) A x A B x C Precast Cast -In -Place 8x16 8x16 36 4 6 12x12 12x12 40 4 6 16x16 16x16 70 8 8 16x24 100 8 - 24 x 24 150 - 8 For SI: 1 inch = 25.4 rum, 1 square foot = 0.0929 m`. a. Footing values are based on single floor and roof loads. b. Support post must rest in center one-third of footing. c. Top of footing shall be level for full bearing support of post. APPENDIX M TOP OF POST JOIST MOUNTED - GIRDER f 2 x 2 LEDGER STRIP OR � DECKS LESS THAN JOIST HANGER REQUIRED 48"FROM GRADE CAN USE 3-16d TOENAILED FOR ATTACHMENT OF DECKS 48"OR GREATER FROM WOOD POST. GRADE REQUIRING LATERAL BRACING SHALL BE ANCHORED AT TOP OF WOOD POSTS WITH APPROVED STRAP OR POST For SI: 1 inch = 25.4 mm. FIGURE AM105.1(1) TOP MOUNT/FLUSH GIRDER Floor joist Connector bock at each I� max D.C. spacing joist nailed to side of joist with 3-8d nails and face nailed through each 2-1/g" bogs girder ply with 2-16d Deck post with nuts nails. Block must fill gap and washers between girder plies. split girder limited to floor loads only and cantilever girder ends allowed per AM105.1(4). For SI: I inch = 25.4 mm. FIGURE AM105.1(3) SPLIT GIRDER SECTION AM106 JOIST SPANS AND CANTILEVERS AM106.1 Joist spans for uncovered porches and decks. Maximum allowable spans for wood deck joists, as shown in Figure AM106.1, shall be in accordance with Table AM106.1. Deck joists shall be permitted to cantilever not greater than one-fourth of the actual, adjacent joist span. AM106.1.1 Lateral restraint at supports. Joist ends and bearing locations shall be provided with lateral restraint to prevent rotation. Where lateral restraint is provided by 2- 5/8'GALV. THROUGH BOLTS WITH NUTS AND WASHER For SI: 1 inch = 25.4 mm FIGURE AM105.1(2) SIDE MOUNT DROPPED GIRDER GIRDER CAN HAVE DECORATIVE CLIP. CLIP NOTTO EXCEED D/4. D=DEPTH OF MEMBER 14 For SI: 1 inch = 25.4 rum. FLOORJOISTS APPENDIX M 0 CV For SI: 1 inch = 25.4 mm, 1 square foot = 0.0929 m2 �1 1 r ............. ....•........ Note: Tributary area of shaded section on the free standing deck shown is 5' x 6' = 30 square feet (2.79 m2). Code will require a minimum footing of 8" x 16" (203 mm x 406 mm) in accordance with Table AM102.1. FIGURE AM102.1(2) CALCULATED TRIBUTARY AREA SECTION AM103 FLASHING AM103.1 Flashing. When attached to a structure, the struc- ture to which it is attached shall have a treated wood band for the length of the deck, or corrosion -resistant flashing shall be used to prevent moisture from coming in contact with the untreated framing of the structure. Aluminum flashing shall not be used in conjunction with deck construction. The deck band and the structure band shall be constructed in contact with each other except on brick veneer structures and where plywood sheathing is required and properly flashed. Siding shall not be installed between the structure and the deck band. If attached to a brick structure, neither the flashing nor a treated band for brick structure is required. In addition, the treated deckband shall be constructed in contact with the brick veneer. Flashing shall be installed in accordance with Figure AM103.1. SECTION AM104 DECK ATTACHMENT AM104.1 Deck attachment. When a deck is supported at the structure by attaching the deck to the structure, Tables AM104.1(1) and AM104.1(2) shall apply for attaching the deck band to the structure. AM104.1.1 Masonry ledge support. If the deck band is supported by a Ininimum of 112 inch (13 nun) masonry ledge along the foundation wall, 5/8-inch (16 rum) hot -dip galvanized bolts with washers spaced at 48 inches (1219 mm) o.c. are permitted to be used for support. AM104.1.2 Other means of support. Joist hangers or other means of attachment are permitted to be connected to the house band and shall be properly flashed. SECTION AM105 GIRDER SUPPORT AND SPAN AM105.1 General. Girders shall bear directly on the support post with the post attached at top to prevent lateral displace- ment or be connected to the side of the posts with two 5/8- inch (16 mm) hot -dip galvanized bolts with nut and washer. Girder support is permitted to be installed in accordance with Figure AM 105.1(1) for top mount; Figure AM 105.1(2) for side mount and Figure AM105.1(3) for split girders. See Fig- ure AM105.1(4) for cantilevered girders. AM105.2 Girder span for uncovered porches and decks. Maximum allowable spans for wood deck girders, as shown in Figure AM105.2, shall be in accordance with Table AM105.2. Girder plies shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches (406 mm) on center along each edge. Girders shall be permitted to canti- lever at each end up to one-fourth of the actual beam span. Splices of multispan beams shall be located at interior post locations. AM105.3 Girder span for roofed porches and decks. Girder spans for covered decks shall be in accordance with Tables R602.7(1) and (2). APPENDIX M TABLE AM105.2 DECK GIRDER SPAN LENGTHS,, b (feet - inches) SPECIES` SIZEd DECK JOIST SPAN LESS THAN OR EQUAL TO: (feet) 6 a 10 12 14 16 18 2- 2 x 6 6-11 5-11 5-4 4-10 4-6 4-3 4-0 2- 2 x 8 8-9 7-7 6-9 6-2 5-9 5-4 5-0 2 - 2 x 10 104 9-0 8-0 7-4 6-9 64 6-0 Southern 2-2 x 12 12-2 10-7 9-5 8-7 8-0 7-6 7-0 pine 3- 2 x 6 8-2 7-5 6-8 6-1 5-8 5-3 5-0 3- 2 x 8 10-10 9-6 8-6 7-9 7-2 6-8 6-4 3-2 x 10 13-0 11-3 10-0 9-2 8-6 7-11 7-6 3-2 x 12 15-3 13-3 11-10 10-9 10-0 9-4 8-10 3 x 6 or 2- 2 x 6 5-5 4-8 4-2 3-10 3-6 3-1 2-9 3 x 8 or 2- 2 x 8 6-10 5-11 5-4 4-10 4-6 4-1 3-8 3 x 10 or 2- 2 x 10 8-4 7-3 6-6 5-11 5-6 5-1 4-8 Douglas fir -larch`, 3 x 12 or 2- 2 x 12 9-8 8-5 7-6 6-10 6-4 5-11 5-7 hem -fir', 4 x 6 6-5 5-6 4-I1 4-6 4-2 3-11 3-8 spruce -pine -fir`, redwood, 4 x 8 8-5 7-3 6-6 5-11 5-6 5-2 4-10 western cedars, 4 x 10 9-11 8-7 7-8 7-0 6-6 6-1 5-8 ponderosa pinef 4 x 12 11-5 9-11 8-10 8-1 7-6 7-0 6-7 red pinef 3- 2 x 6 7-4 6-8 6-0 5-6 5-1 4-9 4-6 3- 2 x 8 9-8 8-6 7-7 6-11 6-5 6-0 5-8 3- 2 x 10 12-0 10-5 9-4 8-6 7-10 7-4 6-11 3 -2 x 12 13-11 12-1 10-9 9-10 1 9-1 8-6 8-1 For SI: 1 inch = 25.4 rum, 1 foot = 304.8 rum, I pound per square foot = 0.0479 kPa, 1 pound = 0.454 kg. GIRDER a. Ground snow load, live load = 40 psf, dead load = 10 psf, L/A = 360 at main span, L/A = 180 at cantilever with a 220-pound point load applied at the end. b. Girders supporting deck joists from one side only. CANTILEVERED GIRDER IS LIMITED TO c. No. 2 grade, wet service factor. FLOOR LOADS ONLY, ROOF LOADS PROHIBITED ON CANTILEVERED d. Girder depth shall be greater than or equal to depth of joists with a flush beam condition. GIRDERAPPUCA71ON e. Includes incising factor. I. Northern species. Incising factor not included. FIGURE AM105.1(4) CANTILIEVERED DROPPED GIRDER joist hangers or blocking between joists, their depth shall equal not less than 60 percent of the joist depth. Where lat- eral restraint is provided by rim joists, they shall be secured to the end of each joist with not less than (3) 10d (3-inch x 0.128-inch) nails or (3) No. 10 x 3-inch (76 Turn) long wood screws. AM106.2.Roofed porches and decks. Joists spans shall be in accordance with Table R502.3.1(2) with 40-pounds per - square -foot live load and 10-pounds per -square -foot dead load. Cantilevered floor joists shall be in accordance with Table R502.3.3(1). .rolsrs .I u POST Po91 0"'o i fiEUI BPAN -oc.I OPTiONLL EEMA SPAN OPTpxAL CANTEEVER r./wrnEVER EANTIEEVER GNIrtEVER DROPPED BEAM FLUSH BEAM FIGURE AM105.2 TYPICAL DECK GIRDER SPANS HOU TOc.ATED BANDS ON BOTH HOUSE AND DECK 4 BE IN CONTACT WITH FLASHING. DECK HOUSE FLASHING SHALL BE BETWEEN BANDS FC DEPTH AND KICK OU UNDERNEATH IF SID BELOW. FLASHING S EXTEND UNDERNEA SIDING ABOVE A MIN NO FLASHING -TREATED FLASHING BETWEEN For SI: l inch = 25.4 mm FIGURE AM103.1 FLASHING FOR DECK ATTACHED TO STRUCTURE TABLE AM104.1(1) DECK ATTACHMENT FOR ALL STRUCTURES EXCEPT BRICK VENEER APPENDIX M =CK FASTENERS S' MAX JOIST SPAN' 16' MAX JOIST SPAN' 5/8" Hot -dip galvanized bolts with nut and washerb and 12d Common hot -dip galvanized nails' 1 @ 3'-6" o.c. and 2 @ 8" o.c. 1 @ V-8" o.c. and 3 @ 6" o.c. OR Self -drilling screw fastener 12" o.c. staggered 6" o.c. staggered For SI: 1 inch = 25.4, 1 foot = 304.8 mm a- Attachment interpolation between 8 foot and 16 foot joists span is allowed. b. Minimum edge distance for bolts is 21/2 inches. c- Nails must penetrate the supporting structure band a minimum of 11/2 inches. d. Self -drilling screw fastener having a minimum shank diameter of 0.195 inches and a length long enough to penetrate through the supporting structure band. The structure band shall have a minimum depth of 11/s inches. Screw shall be evaluated by an approved testing agency for allowable shear load for Southern Pine to Southern Pine lumber of 250 pounds and shall have a corrosion -resistant finish equivalent to hot dip galvanized. Minimum edge distance for screws is 17/16 inches. A maximum of 1/2 inch thick wood structural panel is permitted to be located between the deck ledger and the structure band. TABLE AM104.1(2) DECK ATTACHMENT FOR BRICK VENEER STRUCTURES FASTENERS 8' MAX JOIST SPAN' 16' MAX JOIST SPAN' 5/8" Hot -dip galvanized bolts with nut and washerb 1 @ 2'-4" o.c. 1 @ l'-4" o.c. For SI: 1 inch = 25.4, 1 foot = 304.8 rum. a. Attachment interpolation between 8 foot and 16 foot joist span is allowed. b. Minimum edge distance for bolts is 21/2 inches. APPENDIX M TABLE AM106.1 DECK JOIST SPANS FOR COMMON LUMBER SPECIESf (feet - inches) SPECIES' SIZE SPACING OF DECK JOISTS WITH NO CANTILEVERb (inches) SPACING OF DECK JOISTS WITH CANTILEVERS* (inches) 12 16 24 12 16 24 2 x 6 9-11 9-0 7-7 6-8 6-8 6-8 Southern 2 x 8 13-1 11-10 9-8 10-1 10-1 9-8 pine 2 x 10 16-2 14-0 11-5 14-6 14-0 11-5 2 x 12 18-0 16-6 13-6 18-0 16-6 13-6 2 x 6 9-6 8-8 7-2 6-3 6-3 6-3 Douglas fir-lazchd, hem -find, 2 x 8 12-6 11-1 9-1 9-5 9-5 9-1 spruce-pine-fird 2 x 10 15-8 13-7 11-1 13-7 13-7 11-1 2 x 12 18-0 15-9 12-10 18-0 15-9 12-10 Redwood, 2 x 6 8-10 8-0 7-0 5-7 5-7 5-7 western cedars, 2 x 8 11-8 10-7 8-8 8-6 8-6 8-6 ponderosa pine'. 2 x 10 14-I1 13-0 10-7 12-3 12-3 10-7 red pine' 2 x 12 17-5 15-1 12-4 16-5 15-1 12-4 For SI: 1 inch = 25A mm, I foot = 304.8 rum, I pound per square foot = 0.0479 kPa, I pound = 0.454 kg. a. No. 2 grade with wet service factor. b. Ground snow load, live load = 40 psf, dead load = 10 psf, L/A = 360. c. Ground snow load, live load = 40 psf, dead load = 10 psf, L/A = 360 at main span, L/A = 180 at cantilever with a 220-pound point load applied to end. d. Includes incising factor. e. Northern species with no incising factor. I. Cantilevered spans not exceeding the nominal depth of the joist are permitted. euEwcvn... ,.. nu�o,sr �aarNNNam ,rwu �nsr N...r<R �mrN.Nm" FIGURE AM106.1 TYPICAL DECK JOIST SPANS N L.L 0 LU Y LU N N O N 7(-3^, C'I) W T m z Y U (Z Q m LU zco J 70 U I U) 0 U) 0 U C cr) C7 E 0) W CD 00 Do CO 0) � Qi D 0 0 O 06 t�:, t tll 0) LLi LLi m Z J '> O= O Y C/) lL 2 C O U 6 Q co U CZ N > .r > Z 0.) YCZ c00 U _J ti to I ­ GO /L W E O U ^� W � O ~ M J °' o W 0) O Z Q W cc: O LL m aNi a O lv U) m 70 U) cis U O L CO O N O T W SECTION AM107 FLOOR DECKING AM107.1 Floor decking. Floor decking shall be No. 2 grade treated Southern Pine or equivalent. The minimum floor deck- ing thickness shall be in accordance with Table AM107.1. TABLE AM107.1 FLOOR DECKING THICKNESS SPACING DECKING (nominal) 12" o.c. I" S4S 16" o.c. 1" T&G 19.2" o.c. 1 /4" S4S 24"-36" o.c. 2" S4S For SI: I inch = 25.4, 1 toot = 304.8 rum. SECTION AM108 POST HEIGHT AM108.1 Post height. Maximum height of deck support posts shall be in accordance with Table AM 108.1. TABLE AM106.1 DECK SUPPORT POST HEIGHT POST SIZE- MAXIMUM POST HEIGHTb•- 4" x 4" 8'-0" 6" x 6" 2.0'-0" For SI: 1 inch = 25.4, 1 toot = 304.8 mm. a. This table is based on No. 2 Southern Pine posts. b. From top of footing to bottom of girder. c. Decks with post heights exceeding these requirements shall be designed by a registered design professional. SECTION AM109 DECK BRACING AM109.1 Deck bracing. Decks shall be braced to provide lateral stability. Lateral stability shall be provided in accor- dance with one of the methods in Sections AM109.1.1 through AM109.1.5. AM109.1.1 Lateral bracing not required. When the deck floor height is less than 4 feet (1219 min) above fin- ished grade as shown in Figure AM109.1(1) and the deck is attached to the structure in accordance with Section AM104, lateral bracing is not required. Lateral bracing is not required for freestanding decks with a deck floor height 30 inches (762 min) or less above finished grade. AM109.1.2. Knee bracing. 4 x 4 wood knee braces are permitted to be provided on each column in both direc- tions. The knee braces shall attach to each post at a point not less than 1/3 of the post length from the top of the post, and the braces shall be angled between 45 degrees (0.79 rad) and 60 degrees (1.05 rad) from the horizontal. Knee braces shall be bolted to the post and the girder/double band with one 5/8-inch (16 min) hot -dip galvanized bolt with nut and washer at both ends of the brace as shown in Figure AM109.1(2) 2. The headroom for spiral stairways shall be in accordance with Section R311.7.10.1. R311.7.3 Vertical rise. A flight of stairs shall not have a vertical rise larger than 147 inches (3734 min) between floor levels or landings. R311.7.4 Wakkline. Deleted. R311.7.5 Stair treads and risers. Stair treads and risers shall meet the requirements of this section. For the pur- poses of this section, dimensions and dimensioned sur- faces shall be exclusive of carpets, rugs or runners. R311.7.5.1 Risers. The riser height shall be not more than $14 inches (210 rum). The riser shall be measured verti- cally between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 rpm). The too and bottom riser of interior stairs shall not exceed the smallest riser within that stair run by more than 414 inch (19 min). The height of the too and bottom riser of the interior stairs shall be measured from the permanent fin- ished surface (carnet excluded). Where the bottom riser of an exterior stair adjoins an exterior walk. porch. drive- way. Patio. garage floor. or finish grade. the height of the riser may be less than the height of the adjacent risers. R311.7.5.2 Treads. The minimum tread depth shall be not less than 9 inches (229 rum). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 rum). R311.7.5.2.1 Winder treads. Winder treads shall have a tread depth of not less than 9 inches (229 min) measured between the vertical planes of the foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 4 inches (102 min) at any point within the clear width of the stair. Within any flight of stairs, the largest winder tread depth at the walkline shall not exceed the smallest winder tread by more than 3/g inch (9.5 mm). R311.753 Nosings. The radius of curvature at the nos- ing shall be not greater than 9/16 inch (14 rum). A nosing projection not less than 3/4 inch (19 min) and not more than 11/4 inches (32 min) shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the smallest nosing projection by more than inch (9.5 min) between two stories, including the nosing at the level of floors and landings. Beveling of nosings shall not exceed 1/2 inch (12.7 rum). Exceptions: L A nosing projection is not required where the tread depth is not less than 11 inches (279 mm). 2 The opennng between adjacent treads is not limited on stairs with a total rise of 30 inches (762 min) or less. APPENDIX M AM109.13. Post embedment. For free standing decks without knee braces or diagonal bracing, lateral stability is permitted to be provided by embedding the post in accor- dance with Figure AM109.1(3) and Table AM109.1. TABLE AM109.1 POST EMEBEDMENT FOR FREE STANDING DECKS MAXIMUM MAXIMUM EMPEDMENT CONCRETE POST SIZE TRIBUTARY POST DEPTH DIAMETER AREA HEIGHT 4" x 4" 48 SF 4'-0" 2'-6" 1'-0" 6" x 6" 120 SF 6-0" T-6" F-8" For SI: 1 inch = 25.4 mm, I square foot = 0.0929 m`. Grade Less than 4' (decking to grade) and attached to structure no bracing required For SI: 1 inch = 25A, 1 foot = 304.8 mm. FIGURE AM109.1(1) NO LATERAL BRACING Freestanding decks Decks attached to requiring bracing structure require shall be installed in diagonal bracing both directions oft only at outside girder each post line parallel with Attached not Braces shall Less than 1/3 of be between Post length 45 and 6D degrees For SI: 1 inch = 25.4, 1 foot = 304.8 mm. FIGURE AM109.1(2) KNEE BRACING BUILDING PLANNING R311.7.5.4 Exterior plastic composite stair treads. Plastic composite exterior stair treads shall comply with the provisions of this section and the requirements of ASTM D7032. R311.7.6 Landings for stairways. There shall be a floor or landing at the tW and bottom of each stairway. A flight of stairs shall not have a vertical rise larger than 12 feet 3 inches (3734 min) between floor levels or landings. The width of each landing shall not be less than the width of the stairway served. Every landing Shall have a minimum dimension of 36 inches (914 min) measured in the direc- tion of travel. Exception: A floor or landing is not required at the top of an interior flight of stairs, including stairs in an enclosed garage, provided that a door does not swing over the stairs R311.7.7 Stairway walking surface. The walking surface of treads and landings of stairways shall be sloped not steeper than one unit vertical in 48 inches horizontal (2-per- cent slope). R311.7.8 Handrails. Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. R311.7.8.1 Height. Handrail height, measured veftj- cally from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 min) and not more than 38 inches (965 rum). Exceptions: 1. The use of a volute, turnout or starting easing shall be allowed over the lowest tread. 2. Where handrail fittings or bendings are used to provide continuous transition between flights, transitions at winder treads, the transition from handrail to guard, or used at the start of a flight, the handrail height at the fittings or bendings shall be permitted to exceed 38 inches (956 mm). R311.7.8.2 Continuity. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches (38 min) between the wall and the handrails. Exceptions: 1. Handrails shall be permitted to be interrupted by a newel post at the turn. 2. The use of a volute, turnout, starting easing or starting newel shall be allowed over the lowest tread. 2 Two or more separate rails shall be considered continuous iftbe termination ofthe rails within 6 inches (152 min) of each other. If tran- sitioning between a wall -mounted handrail and APPENDIX M AM109.1.4. Cross bracing. 2 x 6 diagonal vertical cross bracing is permitted to be provided in two perpendicular directions for free standing decks or parallel to the struc- ture at the exterior column line for attached decks. The 2 x 6 bracing shall be attached to the posts with one 5/,-inch (16 mm) hot -dip galvanized bolt with nut and washer at each end of each bracing member in accordance with Fig- ure AM109.1(4). AM109.1.5. Piles in coastal regions. For embedment of piles in coastal regions, see Chapter 46. DECKS ATTACHED TO STRUCTURECAN ALSO BE BRACED ON EXTERIOR GIRDER LINE WITH EMBEDMENT OPTION For SI: I inch = 25.4, 1 foot = 304.8 mm. FIGURE AM109.1(3) POSTEMBEDMENT IF SPAN BETWEEN MAX POST HEIGHT FOR 4x41S4' FROM TOP OF FOOTER, 6' FOR6x6 POST IS GREATER THAN CENTER BLOCKING AND ONE 518"BOLT WITH NUTAND WASHER REQUIRED For SI: 1 inch = 25.4, 1 foot = 304.8 rum. BUILDING PLANNING SECTION AM110 STAIRS AM110.1 Stair construction. Stringer spans shall be no greater than 7 feet (2134 nun) between supports. Spacing between stringers shall be based upon decking material used in accordance with AM107.1. Each stringer shall have a mini- mum of 31/2 inches (89 rum) between step cut and back of stringer. If used, suspended headers shall be attached with 3/8- inch (9.5 mm) galvanized bolts with nuts and washers to securely support stringers at the top. See Figure AM 110.1. MAX SPACING BETWEEN STRINGERS 36". F MIN T MAX. STRINGER SPAN BETWEEN SUPPORTS For SI: I inch = 25.4, 1 foot = 304.8 mm. FIGURE AM110.1 STAIR STRINGER FIGURE AM109.1(4) CROSS BRACING a guardrail/handrail, the wall -mounted rail shall return into the wall. R311.7.83 Grip -size. Required handrails shall be of one of the following types or provide equivalent grasp - ability. 1. Type I. Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches (32 min) and not greater than 2 inches (51 mm). If the handrail is not circular, it shall have a perimeter dimension of not less than 4 inches (102 min) and not greater than 61/4 inches (160 min) with a cross section of dimension of not more than 21/4 inches (57 nun). Edges shall have a radius of not less than 0.01 inch (0.25 rum). 2. T�pe II. Handrails with a perimeter greater than 6 /4 inches (160 min) shall have a graspable finger recess area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch (19 min) measured vertically from the tallest portion of the profile and achieve a depth of not less than 5/16 inch (8 min) within 7/8 inch (22 min) below the widest portion of the profile. This required depth shall continue for not less than 3/g inch (10 nun) to a level that is not less than 13/4 inches (45 min) below the tallest portion of the profile. The width of the handrail above the recess shall be not less than 11/4 inches (32 mm) and not more than 23/4 inches (70 mm). Edges shall have a radius of not less than 0.01 inch (0.25 min). Exception: Exterior handrails (garages andand areas exposed to the weather) shall not be more than 3'-(2 inches (89 mm) in cross-section dimension. R311.7.8A Exterior plastic composite handrails. Plastic composite exterior handrails shall comply with the requirements of ASTM D7032. R311.7.9 Illumination. Stairways shall be provided with illumination in accordance with Section R303.7. R311.7.10 Special stairways. Spiral stairways, bulkhead enclosure stairways and bowed tread stairways shall com- ply with the requirements of Section R311.7 except as specified in Sections R311.7.10.1 through R311.7.10.3. R311.7.10.1 Spiral stairways. Spiral stairways are permitted, provided that the clear width at and below the handrail is not less than 26 inches (660 rum) and the walkline radius is not greater than 241/2 inches (622 min). Each tread shall have a depth of not less than 61/4 inches (171 mm) at the walkline. All treads shall be identical, and the rise shall be not more than 9'/2 inches (241 min). Headroom shall be not less than 6 feet 6 inches (1982 rum). R311.7.10.2 Bulkhead enclosure stairways. Stair- ways serving bulkhead enclosures, not part of the required building egress, providing access from the out- side grade level to the basement shall be exempt from the requirements of Sections R311.3 and R311.7 where the height from the basement finished floor level to ONE 5/8"BOLT TOP AND BOTTOM END WITH NUT AND WASHER grade adjacent to the stairway is not more than 8 feet (2438 min) and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. R311.7.10.3 Bowed tread stairways. Bowed tread stairways are permrttect provt0eu mey are unlrorm in bowed tread depth along the entire width of the tread with not more than 14-inch (9.5 rum) variance from greatest to smallest tread in the stairway flight. At no point shall the tread be less than 9 inches (229 min) with a nosing as listed in Sections R311.7.5.2 and R 11 7... qp tiv lv R311.7.10.3.1 Standard stairway application. The bottom three treads in a standard straight rim stair- way application as listed under Section R311.7.5.2 are permitted to bow provided that. at no Point along the width of the tread, they are less than 9 inches (229 min) as measured under Section R311.7.5.2 and each bowed tread is uniform with other bowed treads with no more than }/a inch (9.5 min) variance from greatest to least. Nosing is required as listed in Section R311.7.5.3. R311.7.10.3.2 Bowed tread circular stairways. Bowed treads in a circular stairway are permitted provided they are uniform. as per winder treads as listed in Section R311.7.5.2. measured at a point 12 inches (305 trim) from the side where the treads are narrower. At this walk line. bowed treads must be uniform with other circular stairway treads with the greatest tread not to exceed the smallest by more than 34 inch (9.5 rum). Nosing is required as listed in Section R311.7.5.3. R311.7.11 Alternating tread devices. Deleted, R311.7.12 Ships ladders. Ships ladders shall not be used as an element of a means of egress. Ships ladders shall be permitted provided that a required means of egress stair- way or ramp serves the same space at each adjoining level or where a means of egress is not required. The clear width at and below the handrails shall be not less than 20 inches. R311.7.12.1 Treads of ships ladders. Treads shall have a depth of not less than 5 inches (127 rum). The tread shall be projected such that the total of the tread depth plus the nosing projection is not less than 81/2 inches (216 trim). The riser height shall be not more than 91/2 inches (241 rum). R311.7.12.2 Handrails of ships ladders. Handrails shall be provided on both sides of ships ladders and shall comply with Sections R311.7.8.2 to R311.7.8.4. Handrail height shall be uniform, not less than 30 inches (762 nun) and not more than 34 inches (864 min). R311.8 Ramps. R311.8.1 Maximum slope. Ramps serving the egress door required by Section R311.2 shall have a slope of not I more than 1 unit vertical in 12 units horizontal (8.3-per- cent slope). All other ramps shall have a maximum slope I of 1 unit vertical in 8 units horizontal (12.5 percent). SECTION AM111 HANDRAILS, GUARDS AND GENERAL AM111.1 Handrails, guards and general. Deck handrails, guards and general construction shall be as shown in Figure AM111.1. Guards at a minimum 36" height required in accordance with R312.1.2 with 30' drop and opening limits per R312.1.3, top rail and post to support 2001hs with infill to meet 50 Ibs in accordance with Table R301.5 and footnotes. Rail Dos ls cannot exceed fro.c, spacing and shall be attached with 2-318' galy_ bolts with nut & washer to outer bands. Stair handrail/Guard. Height between 34--38" in accordance with R311.7.8.1 & R312.1. Openings on side of stairs requiring guards shall not allow a sphere 4 316' to pass in accordance with R312.1.3 exceotion #2. Stairs treads and risers per R311.7.5.1 (8 ''/," max riser) & R311.7.5.2 (9" minimum tread depth). Stairways min 36' width per R311.7.1 (rail projections allowed). risers Riser openings. Stairs with a 30" or more vertical rise must have solid or opening restricted to prevent a 4' sphere From passing per R311.7.5.1. APPENDIX M Attachment to structure based upon SectionsAM104.t AM104.1.1 and AM104.1.2. Decking per AM107 for #2 SYP and attached with 2-8d galv nails at each joist or approved screws. Other materials per mfg installation based upon joists o.c. spacing, Alternate material attached per mfg installation instructions. Deck post per AM108 Footers per Table AM102.1. Minimum base of footers 12' below grade. Exterior Girder Clear Spans See Table AM105.2 for uncovered decks and Tables R602.7(1) and (2) for covered decks. Lateral Bracing per AM 109. Floor Joist cantilevers allowed per AM109.1.1 height required; Section Al for uncovered AM109.1.2 knee bracing; AM109.1.3 decks and Table R502.3.3(1) for freestanding embedment; AM109.1.4 covered decks diagonal bracing; AM109.1.5 Coastal embedment. For SI: 1 inch = 25.4, 1 foot = 304.8 mm. FIGURE AM111.1 DECK CONSTRUCTION B. Encroachments into Required Yards Unless otherwise regulated within this Ordinance, the following encroachment standards shall apply: Commentary: Easements, other ordinances, or other legally established restrictions may limit encroachments otherwise allowed by this Ordinance. 1. Chimneys, pre -fabricated chimneys, flues, or smokestacks can extend into yard spaces but shall not occupy more than 30 square feet of the required yard space. 2. Fire escapes can project up to eight feet into any required yard. Fire escapes in the DD District are permitted to extend beyond the property line. 3. Cornices, eaves, ornamental features, and awnings can extend up to five feet into any required yard, but shall remain at least two feet from the property line, except on zero lot line homes. 4. Marquee signs can extend into yard spaces in conformance with standards found in the Sec. 11.6, Signs Requiring Permits. 5. Pedestrian bridges, breezeways, and supports of these structures can extend into required yards for transit access. 6. Security gates and guard stations can be located within any required yard. 7. For residential uses: decks, uncovered terraces, and at -grade patios can extend up to four feet into any required side yard, or up to eight feet into any required street yard, or within four feet of a rear property line. For nonresidential uses, such features can be located within any yard. 8. Surface parking and associated lighting, uncovered steps, and handicapped access ramps can be located within any yard. co L1J CO Q T N LL O N 0 LLI rr Y U LU 0 N N O N E O U C: co M E 0) Ib CC)CO rb a) (D (D V to 06 O C) 0) LLI LU m s= Z J > } O M a) 2 O Y (n 0- C O U 6 Q m (D N N > Z Y ro co CO U J I- to 00 �7L W E O U c,s p ^, W p O M g C: O ^1 W O Z Q J Ir O LL m N \ O c O U) m W 70 7o E U o J Z L (D CD C) N Or W