Loading...
HomeMy WebLinkAboutGW1-2023-00350_Well Construction - GW1_20230120 w ®, NORTH CAROLINA ilk WELL CONSTRUCTION RECORD (GW-1 ) EnvfronmertmfQua(Iry Form GW-1 Well Construction Electronic Form North Carolina Department of Environmental Quality Division of Water Resources November1 Submission ID# G W 1-2023-00350 Are you submitting a scanned form?* Yes No CONTACT INFORMATION ....................................................................................................................... Email Address* Contact Name* Will.Keyes@GriffinDewatering.co Will Keyes m Is this a revision to the form you have previously submitted?* Yes No WELL CONSTRUCTION INFORMATION .................... ................... ................... ................... ............... .................................................... 1.Who is installing these wells?* Owner Well Contractor 1.Well Contractor Information: ........ ......... ..... ......... ......... ......... ......... ..... ......... Certiticate# Cert Level First Name Last Name Company Name 4220 A WILLIAM KEYES Griffin Dewatering 2.Well Construction Permit#: .......................................... ................................... NA/Private List all applicable well construction permits(i.e.Monitoring Wells,UIC-Underground Injection Control,CCPCUA-Central Coastal Plain Capacity Use Area,County, etc.) What type of well is this?* Injection Well Non-Water Supply Well Water Supply Well(includes irrigation wells) 3.Non-Water Supply Well* Monitoring Recovery 4.Date well was completed and ID# ......... ......... ......... ......... ..... ......... Date Well Completed* Well ID# Well Yield 12/22/2022 EW-1 3 (gallons per minute)" 12/22/2022 EW-2 3 (gallons per minute)" 12/22/2022 EW-3 3 (gallons per minute)" 12/22/2022 EW-4 3 (gallons per minute)" 12/22/2022 EW-5 3 (gallons per minute)" 12/22/2022 EW-6 3 (gallons per minute)" 12/22/2022 EW-7 3 (gallons per minute)" 12/22/2022 EW-8 3 (gallons per minute)" 12/22/2022 EW-9 3 (gallons per minute)" 12/22/2022 EW-10 3 (gallons per minute)" 12/22/2022 EW-11 3 (gallons per minute)" 5.Well Location Facility/Owner Name* Duke Energy Facility ID# (Required) (If applicable) County* Parcel Identification No.(PIN) Gaston Physical Address* Street Address Plant Allen Road Address Line 2 City State/Province/Region Belmont NC Postal/Zip Code Country 28012 us Latitude* 35.1870732000 Longitude*81.0153993000 Decimal degrees Decimal degrees 6.Is(are)the well(s):* Permanent Temporary 7.Is this a repair to an existing well:* Yes No If this is a repair,fill out known well construction information and explain the nature of the repair under#21 remarks section or on the back of this form. For multiple Geoprobe/DPT or Closed-Loop Geothermal Wells having the same construction,only 1 GW-1 is needed. 8a. Indicate TOTAL NUMBER of wells drilled: 11 9.Total well depth below land surface: (ft.) 9a.What is the depth of the casing from ground 70 surface? For multiple wells list all depths if different 30 (example-3@200'and 2@100') in feet 10.Static water level below top of casing: (ft.) 11.Borehole diameter: 23 6 If water level is above casing,use"+" in inches 12.Well construction method: Auger Air Rotary Cable Tool Direct Push Mud Rotary Rotosonic Other 14.WATER BEARING/FRACTURE ZONES From To Description 23 70 fine grained silts/weathered structuring/Clay in feet in feet 15.OUTER CASING(for multi-cased wells)OR LINER(if applicable) From To Diameter Thickness Material in feet in feet in inches 17.SCREEN From To Diameter Thickness Material 30.00 70.00 4.00 Schd 40 PVC in feet in feet in inches 18.GROUT ............................................ From To Material Emplacment Method&Amount in feet in feet 19. SAND/GRAVEL PACK(if applicable) From To Material Emplacment Method 0.00 70.00 #1a sand poured from surface in feet in feet 20. DRILLING LOG From To Description(color, hardness,soil/rock type,grain size,etc.) 0.00 20.00 orange clay/silts in feet in feet 20.00 50.00 tan/gray silts in feet in feet 50.00 70.00 partially weather rock in feet in feet 21. Remarks Twin pipe eductor wells inside 4"wells Dewatering system pilot test 22.Site diagram or additional well details: You may upload additional well construction information here. 121222-SSLF Pilot Test-Layout.pdf 152.6KB pdf only CERTIFICATION INFORMATION ............................................................................................................................................... * By signing this form, I hereby certify that the well(s)was(were)constructed in accordance with 15A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23.Certification Kff Ala Signature of Certified Well Contractor GRIFFIN 4" presure and 6" return HDPE Twin Pipe Eductors at +/-30ft OC 0 O Eductor Pump Station with 60HP electric jet pump and Diesel Standby 2" Piezometers at 10ft, 20ft, 50ft, 100ft, and 200ft from pilot test - 50ft deep - 6" to 8"diameter borehole - Installed on side of test closest to SSLF excavation Each Eductor will be: - 70ft deep - 8" diameter borehole - 4" PVC Screen and Casing with 40ft of 20 slot screen 4" HDPE to discharge location GRIFFIN DEWATERING L.L.C. 5306 CLINTON DRIVE HOUSTON, TX 77020 TEL: (713) 676-8000 FAX: (713) 676-8080 E MAIL: griffin@griffindewatering.com WEBSITE: www.griffindewatering.com REV. DESCRIPTION DATE BY APPVD. Duke Energy Allen Closure DRAWN: ML SCALE: NTS This drawing is the property of Griffin Dewatering Corporation and its associated companies and is intended only for 'ts sole or authorized use. It may contain proprietary, public or authorized third party information. Any alteration of this drawing is prohibited, without the express, written consent of an authorized representative of Griffin Dewatering Corporation Gaston County, GA DATE: 12/12/22 SSLF - Pilot Test Layout DWG: 1