Loading...
HomeMy WebLinkAbout#5646_12_2014_FINAL=*V-WKV -- 24 'W North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary January 26, 2015 5646 Mr. Mario Sainz Horsehead Metal Products 484 Hicks Grove Road Mooresboro, NC 28114 Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Sainz: Enclosed is a report for the inspection performed on December 17, 2014 by Jason Smith. Where finding(s) are cited in this report, a response is required. Within thirty days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. If the finding(s) cited in the enclosed report are not corrected, enforcement actions may be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact us at (828) 296-4677. Attachment cc: Master file Jason Smith Sincerely, COY Gary Francies, Technical Assistance/Compliance Specialist Division of Water Resources Water Sciences Section NC wastewater/Groundwater Laboratory Certification Branch 1623 Mall Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road, Raleigh, North Carolina 27607 Phone!919-733-390U FAX:919-733-6241 Internet: www.dwglab.orq An Equal Opportunity) Affirmative Action Employer INSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: 5646 Laboratory Name: Horsehead Metal Products Inspection Type: Field Initial Inspector Name(s): Jason Smith Inspection Date: December 17, 2014 Date Report Completed: January 16, 2015 Date Forwarded to Reviewer: January 16, 2015 Reviewed by: Nick Jones Date Review Completed: January 20, 2015 Cover Letter to use: ® Insp. Initial ❑ Insp. Reg. ❑ Insp. No Finding ❑ Insp. CP ❑ Corrected ❑ Insp. Reg. Delay Unit Supervisor/Chemist III: Gary Francies Date Received: 1 /20/2015 Date Forwarded to Linda: 1/23/2015 Date Mailed: \ 1131 '� 5 1 _c LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): On -Site Inspection Report Horsehead Metal Products NCO089109 484 Hicks Grove Road Mooresboro, NC 28114 5646 December 17, 2014 Field Initial Jason Smith LOCAL PERSON(S) CONTACTED: Mario Sainz, Jim Harris, Casey McMahon, Ron Gilbert, and Charlie Howell I. INTRODUCTION: This laboratory was inspected by a representative of the North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) program to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: The facility has all the equipment necessary to perform the analyses. Proficiency Testing (PT) samples have been analyzed for all certified parameters for the 2014 proficiency testing calendar year and the graded results were 100% acceptable. PT samples for the 2015 proficiency testing calendar year have not yet been analyzed. The laboratory is reminded that these results must be submitted to this office directly from the vendor by September 30, 2015. Contracted analyses are performed by Pace Analytical Services, Inc. Asheville (Certification #40). Current quality assurance policies for Field Laboratories and approved procedures for the analysis of the facility's currently certified parameters were provided at the time of the inspection. III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Documentation A. Finding: Some instances of improper error corrections were observed. Requirement: All documentation errors must be corrected by drawing a single line through the error so that the original entry remains legible. Entries shall not be obliterated by erasures or markings. Wite-Out®, correction tape or similar products designed to obliterate documentation are not to be used. Write the correction adjacent to the error. The correction must be initialed by the responsible individual and the date of change documented. All data and log entries must be written in indelible ink. Pencil entries are not acceptable. Ref: Quality Assurance Policies for Field Laboratories. Page 2 #5646 Horsehead Metal Products B. Finding: The laboratory needs to increase the documentation of purchased materials and reagents. Requirement: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date Received, Date Opened (in use), Vendor, Lot Number, and Expiration Date. Consumable materials such as pH buffers and lots of pre -made standards are included in this requirement. Ref: Quality Assurance Policies for Field Laboratories. C. Finding: Units of measure (Standard Units or S.U.) are not documented on the benchsheet and calibration log. Requirement: The field benchsheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 2H .0805 (g) (1). D. Finding: The true values of the 4 S.U. and 10 S.U. buffers are not documented on the calibration log. Requirement: The following must be documented in indelible ink whenever sample analysis is performed: True values of buffers used for calibration. Ref: NC WW/GW LC Approved Procedure for the Analysis of pH. E. Finding: Sample collection and analysis times are not documented. Requirement: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, sample site, sample collector, and sample analysis time. The field benchsheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 02H .0805 (g) (1). Comment: The time of receipt in the laboratory was documented. This is not required. Collection and analysis times are required in order to demonstrate that the fifteen minute holding time was met. pH — Standard Methods, 4500 H+ B-2000 F. Finding: The facility does not report all the data as required. Requirement: The results of all tests on the characteristics of the effluent, including but not limited to NPDES permit monitoring requirements, shall be reported on the monthly report forms. Ref: 15A NCAC 26 .0506 (b) (3) (J). Comment: The laboratory analyzes pH samples daily, but only reports one value each week as required for their permit. Comment: The laboratory analyzes effluent pH samples every two hours every day. The pH values are averaged. Since pH is a logarithmic value, these results are not allowed to be averaged. Recommendation: It is recommended that the laboratory analyze pH samples for process control by collecting them prior to the final effluent. These values are not required to be reported on the Discharge Monitoring Report. Process control samples need to be clearly labeled as such on the benchsheet. Page 3 #5646 Horsehead Metal Products IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Resources. Data were reviewed for Horsehead Metal Products (NPDES permit #NC0089109) for September and October, 2014. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. V. CONCLUSIONS: Correcting the above -cited findings and implementing the recommendation will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance during the inspection and data review process. Please respond to all findings. Report prepared by: Jason Smith Date: January 16, 2015 Report reviewed by: Nick Jones Date: January 20, 2015