HomeMy WebLinkAbout#5605 - 9 - 2011 - FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: Laboratory Name: Inspection Type: Inspector Name(s): Inspection Date: Date Report Completed: Date Forwarded to Reviewe Reviewed by. Date Review Completed: Cover Letter to use: X Unit Supervisor: Date Received: Date Forwarded to Linda: Date Mailed: 5605 Town of Harmony WWTP Field Initial Chet Whiting September 29, 2011 October 20 2011 r: October 20 2011 Todd Crawford October 24 2011 Insp. Initial _ Insp. Reg. _ Insp. No Finding _ Insp. CP Gary Francies 10/25/2011 11 /3/2011 Corrected Beverly Eaves Perdue Governor 5605 Mr. Steve Lambert Town of Harmony WWTP P.O. Box 118 Harmony, NC 28634 T NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Director November 4, 2011 SUBJECT: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Lambert: Dee Freeman Secretary Enclosed is a report for the inspection performed on September 29, 2011 by Chet Whiting. No findings are cited in this report, a response is not required. We appreciate the fine job you and your staff are doing. As a certification requirement, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email, or if you have questions or need additional information please contact me at 828-296-4677. Sincerely, Gary Francies Unit Supervisor Laboratory Section CC Chet Whiting Gary Francies DENR DWQ Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch One 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Nor hCar®1i_na Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Naturally Phone: 919-733-3908 \ FAX: 919-733-6241 Internet: www.dwglab.org An Equal Opportunity \ Affirmative Action Employer Customer Service: 1.877-623-6748 www.newaterquality.org LABORATORY NAME: NPDES PERMIT # ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: Town of Harmony WWTP NC0087033 P.O. Box 118 Harmony, NC 28634 5605 September 29, 2011 Field Initial Chet Whiting Steve Lambert This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. • The facility is neat and well organized and has all the equipment necessary to perform the analyses. Benchsheets are well designed, easy to follow and concise. Records are well organized and easy to retrieve. At the time of the inspection the laboratory was in the process of obtaining laboratory certification. A certificate was issued on October 27, 2011. - _ - • : - u k Comment: Sample site was not documented. 15A NCAC 2H .0805 (g) (1) states: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, sample site, sample collector, and sample analysis time. The field bench sheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Notification of acceptable corrective action (i.e. a revised benchsheet documenting sample site) was faxed to this office on October 4, 2011. No further response is necessary for this finding. Comment: A few overwritten data entries were observed, however the majority of corrections were performed properly. Quality Assurance Policies for Field Laboratories states: All documentation errors must be corrected by drawing a single line through the error so that the original entry remains legible. Entries shall not be obliterated by erasures or markings. Wite-Out®, correction tape or similar products designed to obliterate documentation are not to be used. Write the correction adjacent to the error. The correction must be initialed by the responsible individual and the date of change documented. All data and log entries must be written in indelible ink. Pencil entries are not acceptable. Notification of Page 2 #5605 Town of Harmony WWTP acceptable corrective action (i.e. a statement that correcting errors by overwriting will no longer be done) was received by e-mail on 10/19/2011. No further response is necessary for this finding. pH — Standard Methods, 20th Edition, 4500 H+ B Comment: The temperature sensing device on the pH meter had not been calibrated against an NIST certified thermometer. The Technical Assistance for Field Analysis of pH document states: All temperature sensing devices on meters must be calibrated against a NIST certified or NIST traceable thermometer annually (every 12 months) and proper corrections made and documented. The meter reading must be less than 10C from the NIST certified reading to be acceptable. Document the serial number and manufacturer of the NIST thermometer that was used in the comparison. Document any correction that applies (even if zero) on both the meter and on a separate sheet to be filed. Notification of acceptable corrective action (i.e. a copy of the temperature sensor calibration from Statesville Analytical Labs) was faxed to this office on October 4, 2011. No further response is necessary for this finding. Comment: There was no system in place to document Proficiency Testing (PT) samples in the same manner as routine environmental samples. Quality Assurance Policies for Field Laboratories states: The analysis of PT samples is designed to evaluate the entire process used to routinely repoii environmental analytical results; therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. Notification of acceptable corrective action (i.e. a statement that performance samples will be documented on bench sheets the same as samples) was received by e-mail on 10/19/2011. No further response is necessary for this finding. Comment: pH values were reported that exceed the method specified accuracy (0.1 S.U.) for this analysis. Standard Methods, 20th Edition, 4500 H+ B. (6) states: A variance of ± 0.1 pH unit represents the limit of accuracy under normal conditions, especially for measurement of water and poorly buffered solutions. For this reason, report pH values to the nearest 0.1 pH unit. Notification of acceptable corrective action (i.e. a statement that as of this time pH values would be reported to 0.1 S.U.) was received by e-mail on 10/19/2011. No further response is necessary for this finding. pH — Standard Methods, 20th Edition, 4500 O G Temperature — Standard Methods, 20th Edition, 2550 Comment: Sample collection and analysis times were not adequately documented. 15A NCAC 2H .0805 (g) (1) states: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, sample site, sample collector, and sample analysis time. The field bench sheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Notification of acceptable corrective action (i.e. a revised benchsheet documenting Temperature and DO samples were analyzed in situ) was faxed to this office on October 4, 2011. No further response is necessary for this finding. IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Quality. Data for NPDES# NC0087033 was reviewed for June and July, 2011. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. Page 3 #5605 Town of Harmony WWTP CONCLUSIONS: All findings noted during the inspection report. The inspector would like to than Report prepared by: Chet Whiting Report reviewed by: Todd Crawford k Date: October 20 2011 Date: October 24, 2011