HomeMy WebLinkAbout#153 - 10 - 2011 - FINALBeverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary December 12, 2011 153 Ms. Debra Tunstell City of Lincolnton WWTP Lab P.O. Box 617 Lincolnton, NC 28092 SUBJECT: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Ms. Tunstell: Enclosed is a report for the inspection performed on October 26, 2011 by Chet Whiting. I apologize for the delay in getting this report to you. Where finding(s) are cited in this report, a response is required. Within 30 days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information please contact me at 828-296-4677. Sincerely, COY' Gary Francies Unit Supervisor Laboratory Section CC: Chet Whiting Master files DENR DWQ Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 \ FAX: 919.733-6241 Internet: www.dwglab.org i An Equal Opportunity \ Affirmative Action Employer Customer Service:1-877-623-6748 www.ncwaterquality.org . INSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: 153 Laboratory Name: City of Lincolnton WWTP Lab Inspection Type: Municipal Maintenance Inspector Name(s): Chet Whiting Inspection Date: October 26, 2011 Date Report Completed: November 28, 2011 Date Forwarded to Reviewer: November 29, 2011 RCyieyyed by: Jason Smith Date Review Completed: December 2, 2011 Cover Letter to use: _ Insp. Initial X Insp. Reg. _ Insp. No Finding _ Insp. CP _Corrected Unit Supervisor: Gary Francies Date Received: 12/6/2011 Date Forwarded for mailing: 12/9/2011 Date Mailed:, L On -Site Inspection Report LABORATORY NAME: NPDES PERMIT #: CERTIFICATE #: AUDITOR(S): LOCAL PERSON(S) CONTACTED: City of Lincolnton WWTP Lab NCO025496 P.O. Box 617 Lincolnton, NC 28092 153 October 26, 2011 Municipal Maintenance Chet Whiting Debra Tunstell This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. I' &IV14:7_TW1•7Tili�rC��t ' a The laboratory was clean and well organized. The facility has all the equipment necessary to perform the analyses. The requirements associated with Findings A and B are new policies that have been implemented by our program since the last inspection. Comment: The Conductivity and Dissolved Oxygen temperature sensors had not been checked within 12 months and the corrections were not posted. The pH meter temperature sensor, thermometers for the TSS oven, refrigerator, water bath and measurement of temperature had been checked but the corrections were not posted. North Carolina Wastewater/Groundwater Laboratory Certification Policy states: All thermometers and temperature measuring devices must be checked every 12 months against a NIST certified or NISI traceable thermometer and the process documented. To check a thermometer or the temperature sensor of a meter, read the temperature of the thermometer/meter against a NIST certified or NIST traceable thermometer and record the two temperatures. The calibration must be performed at a temperature that corresponds to the temperature used by the incubator, refrigerator, freezer, etc. In the case of temperature measuring devices used to perform variable temperature readings the calibration must be performed at a temperature range that approximates the range of the samples. The thermometer/meter readings must be less than or equal to 10C from the NIST certified or NIST traceable thermometer reading. The documentation must include the .serial number of the NIST certified thermometer or NIST traceable thermometer that was used in the comparison. Also make any corrections to the data and document any correction that applies (even if zero) on both the thermometer/meter and on a separate sheet to be filed. (NOTE: Other certified laboratories may provide assistance in meeting this requirement.) Acceptable corrective Page 2 #153 City of Lincolnton WWTP Lab action was performed on -site (i.e., the Conductivity and Dissolved Oxygen meter temperature sensors were checked as required and all corrections were posted). No further response is necessary for this finding. Suspended Solids — Standard Methods, 18th Edition, 2540 D Comment: On 5/2/11, the time that Total Suspended Solids (TSS) samples were removed from the drying oven was not documented. This was the only instance observed in the data reviewed. A. Finding: The laboratory is not basing the reporting limit on the minimum weight gain required by the method. Requirement: Choose sample volume to yield between 2.5 and 200 mg dried residue. To obtain the required residue yield, successive aliquots of samples may be added to the same dish after evaporation or adjust reporting level based upon the weight gain and sample volume used. The minimum reporting value is established at 2.5 mg/L based upon a sample volume used of 1000 mL. Ref: North Carolina Wastewater/Groundwater Laboratory Certification Policy based upon Standard Methods, 20th and 21 st Editions, 2540 C. (3) (d) and 2540 B. (3) (b). Comment: For the instances observed, 500 mL sample was analyzed, and less than 2.5 mg of dried residue was reported. Based on that volume the value reported would be <5 mg/L. Suspended Solids — Standard Methods, 181h Edition, 2540 D Fecal Coliform — Standard Methods, 18th Edition, 9222 D Recommeindation: The TSS and Fecal Coliform duplicate Relative Percent Differences (RPD) acceptance criteria were as large as to 65% due to low sample concentrations. It is recommend that the laboratory consider an alternate method for evaluating low level TSS and Fecal Coliform duplicates that reflects a more realistic assessment. Standard Methods, 21st Edition, 1020 B. (12) (b) and 9020 B. (8) (b) (1 — 5) use a statistical approach to evaluate duplicates. Another option could be a two tiered system, with different acceptance criteria based upon the concentration or value of the result. For example, the acceptance criterion of TSS results below 10 mg/L could be ± 2 mg/L while retaining the current acceptance criterion for results above 10 mg/L. Similarly, the Fecal Coliform acceptance criterion for samples with fewer than 20 colonies could be ± 5 colonies (using actual colonies, rather than the calculated result per 100 mL) while retaining the current acceptance criterion for 20-60 colonies. Comment: While no instances were observed in the data that was reviewed please be aware of our policy when laboratory established or method Quality Control (QC) limits are exceeded: When quality control (QC) failures occur, the laboratory must attempt to determine the source of the problem and must apply corrective action. Part of the corrective action is notification to the end user. If data qualifiers are used to qualify samples not meeting QC requirements, the data may not be useable for the intended purposes. It is the responsibility of the laboratory to provide the client or end -user of the data with sufficient information to determine the usability of the qualified data. Where applicable, a notation must be made on the Discharge Monitoring Report (DMR) form, in the comment section, when any required sample quality control does not meet specified criteria and another sample cannot be obtained. Ref: North Carolina Wastewater/Groundwater Laboratory Certification Policy based upon Standard Methods, 20th Edition, 1020 B. (14). Although this is a recommendation please include a written response stating which duplicate QC evaluation option is going to be used for the above cited methods. Page 3 #153 City of Lincolnton WWTP Lab Ammonia Nitrogen — Standard Methods, 18th Edition, 4500 NH3 F B. Finding: The volume of Ionic Strength Buffer added to samples, blanks and standards is not documented. Requirement: Record volume of 10N NaOH added in excess of 1 mL. Ref: Standard Methods, 18th Edition, 4500 NH3-N F. (4) (e) and (5). Comment: The volume of 10N NaOH used is a part of the calculation to determine the concentration of NH3-N. C. Finding: Units of measure are not documented on the pH calibration log. Requirement: All laboratories must use printed laboratory bench worksheets that include a space to enter the signature or initials of the analyst, date of analyses, sample identification, volume of sample analyzed, VQIIle f1olll the IIIGGIslllelllellt system, lalaor cllld final VcIUFZl to be reported and each item must be recorded each time samples are analyzed. The date and time BOD and coliform samples are removed from the incubator must be included on the laboratory worksheet. Ref: 15A NCAC 2H .0805 (a) (7) (H). Total Residual Chlorine — Standard Methods, 18th Edition, 4500 Cl G Recommendation: The current Total Residual Chlorine (TRC) curve verification was performed using the following concentrations: 20, 50, 75, 150 and 200,ug/L. In order to increase confidence the area of likely sample concentrations, it is recommended that the laboratory verify the internal calibration using the concentrations: 20, 30, 50, 200 and 400 ,ug/L the next time the instruments internal curve is verified. This will also verify the analytical range used to measure Proficiency Testing (PT) samples . The paper trail consisted of comparing laboratory benchsheets and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Quality. Data were reviewed for NPDES permit # NC0025496 for May and June 2011. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. ONOOIM�„•� Correcting the above -cited findings and implementing the recommendations will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance during the inspection and data review process. Please respond to all findings. Report prepared by: Chet Whiting Date: November 28, 2011 Report reviewed by: Jason Smith Date: December 2, 2011