HomeMy WebLinkAbout#5591 - 02 - 2012 - FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: 5591 Laboratory Name: SynTerra Corporation Inspection Type: Field Commercial Initial Inspector Name(s): Jason Smith Inspection Date: February 2, 2012 Date Report Completed: February 28, 2012 Date Forwarded to Reviewer: March 8 2012 Reviewed by: Todd Crawford Date Revs ,AI irnmr%1o+orl �V v�V v♦ VVINV VIA. nn7Ynil Q 2012 March 9 Cover Letter to use: _ Insp. Initial _ Insp. Reg. _ Insp. No Finding _ Insp. CP X Corrected Unit Supervisor: Gary Francies Date Received: 3/9/2012 Date Forwarded to Linda: 3/20/2012 Date Mailed: 1 i°• NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor 5591 Ms. Diane Rosseter SynTerra Corporation 148 River Street, Suite 220 Greenville, SC 29601 Division of Water Quality Charles Wakild, P. E. Director March 21, 2012 Dee Freeman Secretary SUBJECT: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Initial Inspection Dear Ms. Rosseter Enclosed is a report for the inspection performed on February 2, 2012 by Jason Smith. Since the finding(s) cited during the inspection were all corrected prior to the completion of the enclosed report, a response is not required. The staff is commended for taking the initiative in correcting the findings in such a timely manner. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by electronic mail, or if you have questions or need additional information please contact me at 828-296-4677. Sincerely, Gary Francies Certification Unit Supervisor Laboratory Section Enclosure CC: Master File Gary Francies DENR DWO Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 \ FAX: 919-733-6241 Internet: www.dwglab.org NorthCarolina aturrall An Equal Opportunity \ Affirmative Action Employer LABORATORY NAME: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: LOCAL PERSON(S) CONTACTED: INTRODUCTION: On -Site Inspection Report SynTerra Corporation 148 River Street, Suite 220 Greenville, SC 29601 5591 February 2, 2012 Field Commercial Initial Jason Smith Diane Rosseter, John Chastain, Lorene Leuner, Brandon Russo, and Mark Mcdade This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. 11. GENERAL COMMENTS: The laboratory has all the equipment necessary to perform the analyses and it appeared to be well maintained. The system for traceability of standard and reagent preparation is effective, thorough and easy to follow. Technical assistance documents were provided to the laboratory prior to the inspection. Ill. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Documentation Comment: Proficiency Testing (PT) sample analyses were not documented in the same manner as environmental samples. The Quality Assurance for Field Laboratories document states: The analysis of PT samples is designed to evaluate the entire process used to routinely report environmental analytical results. Therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. Notification of acceptable corrective action (i.e., future PT sample results will be documented the same as environmental samples) was received by email on February 6, 2012. No further response is necessary for this finding. pH — SW846 Method 9040 C Comment: A check buffer was not analyzed at mid day or at the end of sampling run. The Technical Assistance for Field Analysis of pH document states: If compliance samples are analyzed throughout the day, a post calibration check (e.g., 7 buffer) must be analyzed mid -day and at the end of the run (i.e., roughly every 4 hours based on an eight hour day). Notification of acceptable corrective action (i.e., a mid -day and end -of -run pH calibration check will be analyzed during future sampling events) was received by email on February 6, 2012. No further response is necessary for this finding. IV Page 2 #5591 SynTerra Corporation PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to client reports. Data were reviewed for Progress Energy Asheville Plant - Ash Pond Well CB-1 for April 12 and July 19, 2011 and Ash Pond Well GW-1 for November 9, 2011. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. V. CONCLUSIONS: All findings noted during the inspection were adequately addressed prior to the completion of this report. The inspector would like to thank the staff for its assistance during the inspection and data review process. No response is required. Report prepared by: Jason Smith Report reviewed by Todd Crawford Date: February 28, 2012 Date: March 9, 2012