HomeMy WebLinkAbout#555 - 03 - 2012 - FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: 555 Laboratory Name: Unimin Schoolhouse Quartz Plant Inspection Type: Industrial Maintenance Inspector Name(s): Jason Smith Inspection Date: March 27 2012 Date Report Completed: April 18, 2012 Date Forwarded to Reviewer: April 18, 2012 Reviewed by: Todd Crawford Date Review Completed: April 19, 2012 Cover Letter to use: _ Insp. Initial X Insp. Reg. _ Insp. No Finding _ Insp. CP _ Corrected Unit Supervisor: Gary Francies Date Received: 4/27/2012 Date Forwarded to Linda: 5/15/2012 Date Mailed: . Beverly Eaves Perdue Governor 555 Mr. Scott Fortner Unimin Quartz Schoolhouse Plant P.O. Box 588 Spruce Pine, NC 28777 a •'NCDENR Division of Water Quality Charles Wakild, P. E. Director May 16, 2012 Dee Freeman Secretary Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Fortner.: Enclosed is a report for the inspection performed on March 27, 2012 by Jason Smith. I apologize for the delay in getting this report to you. Where finding(s) are cited in this report, a response is required. Within thirty days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. If the finding(s) cited in the enclosed report are not corrected, enforcement actions may be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact us at 828-296-4677. Sincerely, ca�� �Z'4� 4-0-kl Gary Francies Certification Unit Supervisor Laboratory Section Enclosure cc: Jason Smith Master File DENR DWO Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina-27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 t FAX: 919-733-6241 Internet: www.dwglab.org One Northfarolina An Equal Opportunity 1 Affirmative Action Employer LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: INTRODUCTION: On -Site Inspection Report Unimin Quartz Schoolhouse Plant NC0000361 P.O. Box 588 Spruce Pine, NC 28777 555 March 27, 2012 Industrial Maintenance Jason Smith Scott Fortner This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. GENERAL COMMENTS: Laboratory personnel changed since the last inspection. The inspector is concerned about the number of transcription errors and record omissions detected during the data review process. Many of the data points recorded on the benchsheet did not compare to the values reported on the Discharge Monitoring Reports (DMRs). These observations are documented in the Paper Trail Investigation section of this report. The laboratory is reminded that any time changes are made to laboratory operations; the laboratory must update the Quality Assurance (QA)/Standard Operating Procedures (SOP) document(s). Any changes made in response to the Findings, Recommendations or Comments listed in this report must be incorporated to insure the method is being performed as stated, references to methods are accurate, and the QA and/or SOP document(s) is in agreement with approved practice and regulatory requirements. In some instances, the laboratory may need to create a SOP to document how new functions or policy will be implemented. The requirements associated with Findings B, C, D and E are new policies that have been implemented by our program since the last inspection. III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: General Laboratory Comment: The laboratory was not documenting the required information for purchased chemicals. North Carolina Wastewater/Groundwater Laboratory Certification Policy states: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date received, Date Opened (in use), Vendor, Lot Number, and Expiration Date (where specified). A system (e.g., traceable identifiers) must be in place that links standard/reagent preparation information Page 2 #555 Unimin Schoolhouse Quartz Plant to analytical batches in which the solutions are used. Documentation of solution preparation must include the analyst's initials, date of preparation, the volume or weight of standard(s) used, the solvent and final volume of the solution. This information as well as the vendor and/or manufacturer, lot number, and expiration date must be retained for primary standards, chemicals, reagents, and materials used for a period of five years. Consumable materials such as pH buffers, lots of pre -made standards and/or media, solids and bacteria filters, etc. are included in this requirement. Demonstration of acceptable corrective action (i.e., the analyst located the traceability log and stated that it would be put into use immediately) was performed at the time of the inspection. No further response is necessary for this finding. A. Finding: The analyst was not able to locate the laboratory Standard Operating Procedures (SOPS). Requirement: Each laboratory shall develop and maintain a document outlining the analytical quality control practices used for the parameters included in their certification. Supporting records shall be maintained as evidence that these practices are being effectively carried out. The quality control document shall be available for inspection by the State Laboratory. Ref: 15A NCAC 2H .0805 (a) (7). Please submit a copy of all laboratory SOPs by December 31, 2012. B. Finding: When duplicate analyses are performed, the laboratory only reports the first result obtained. Requirement: The results of all tests on the characteristics of the effluent, including but not limited to NPDES Permit Monitoring Requirements, shall be reported on monthly report forms. Ref: 15A NCAC 02B .0506 (3) (J). Comment: This is no longer allowed as it was in the past. In order to fulfill the requirements of this Rule, the laboratory must either report the average of the results or report both results on the Discharge Monitoring Report (DIVIR). C. Finding: Proficiency Testing (PT) samples were not analyzed in the same manner as routine environmental samples. Requirement: The analysis of PT samples is designed to evaluate the entire process used to routinely report environmental analytical results; therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. Ref: Proficiency Testing Requirements, February 20, 2012, Revision 1.2. Comment: PT samples were analyzed multiple times. D. Finding: PT samples were not documented on benchsheets in the same manner as routine environmental samples. Requirement: The analysis of PT samples is designed to evaluate the entire process used to routinely report environmental analytical results; therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. Ref: Proficiency Testing Requirements, February 20, 2012, Revision 1.2. E. Finding: The preparation of Proficiency Testing (PT) samples is not documented. Requirement: PT samples received as ampules must be diluted according to the PT provider's instructions. The preparation of PT samples must be documented in a traceable log or other traceable format. The diluted PT sample becomes a routine environmental sample and is added Page 3 #555 Unimin Schoolhouse Quartz Plant to a routine sample batch for analysis. Ref: Proficiency Testing Requirements, February 20, 2012, Revision 1.2. F. Finding: The analytical balance is not being checked with three weights on a quarterly basis. Requirement: The analytical balance must be checked with one class S, or equivalent, standard weight each day used and at least three standard weights quarterly. The values obtained must be recorded in a log and initialed by the analyst. Ref: 15A NCAC 2H .0805 (a) (7) (K). Documentation Recommendation: As shown below, in the paper trail section, there were a significant number of transcription errors. It is recommended that a thorough review, preferably a peer review, of all data be performed on every Discharge Monitoring Report (DMR). Comment: Decimals were often hard to see on the benchsheets and in some cases were missing. While no mathematical or transcription errors were found due to this, it may cause the legal defensibility of the data to be questionable. G. Finding: Several instances of writing over a number as a means of error correction were observed. Requirement: All documentation errors must be corrected by drawing a single line through the error so that the original entry remains legible. Entries shall not be obliterated by erasures or markings. Wite-Out®, correction tape or similar products designed to obliterate documentation are not to be used. Write the correction adjacent to the error. The correction must be initialed by the responsible individual and the date of change documented. All data and log entries must be written in indelible ink. Pencil entries are not acceptable. Ref: North Carolina Wastewater/ Groundwater Laboratory Certification Policy. H. Finding: The date received and date opened is not written on chemical containers. Requirement: Chemicals must be dated when received and when opened. Reagents must be dated and initialed when prepared. Ref: 15A NCAC 2H .0805 (a) (7) (L). Total Suspended Solids — Standard Methods, 191" Edition, 2540 D 1. Finding: A standard is not analyzed quarterly. Requirement: Excluding Oil and Grease, all residue parameters, leachate extractions, residual chlorine, and coliform, analyze one known standard in addition to calibration standards each day samples are analyzed to document accuracy. Analyze one suspended residue, one dissolved residue, one residual chlorine and one oil and grease standard ug arterly. Ref: 15A NCAC 2H .0805 (a) (7) (B). J. Finding: Filters are not weighed to a constant weight after initial washing nor is a dry filter blank analyzed with each set of samples. Requirement: If pre -prepared filters are not used, the method requires that filters must be weighed to a constant weight after washing. In lieu of this process, it is acceptable to analyze a single daily dry filter blank (i.e., no additional rinsing during the analysis). The acceptance criterion for the blank is a weight change of less than 4% of the filter's initial weight or 0.5 mg, Page 4 #555 Unimin Schoolhouse Quartz Plant whichever is less. Ref: North Carolina Wastewater/Groundwater Laboratory Certification Policy based upon Standard Methods, 201h Edition, Method 2540 D. (3) (a). K. Finding: The samples are not weighed to constant weight, nor is an annual multiple weighing study, to verify the adequacy of the drying time, performed. Requirement: Constant weights must be documented. The approved methods require the following: "Repeat the cycle of drying, cooling, desiccating, and weighing until a constant weight is obtained or until the weight change is less than 4% of the previous weight or 0.5 mg, whichever is less." In lieu of this, an annual study documenting the time required to dry representative samples to a constant weight may be performed. Verify minimum daily drying time is greater than or equal to the time used for the initial verification study drying cycle. Drying cycles must be a minimum 1 hour for verification. Ref: North Carolina Wastewater/Groundwater Laboratory Certification Policy based on Standard Methods 20th Edition, 2540 D. (3) (c), 2540 B. (3) (b), and 2540 C. (3) (d). L. Finding: The laboratory is not basing the reporting limit on the minimum weight gain required by the method. Requirement: The minimum weight gain allowed by any approved method is 2.5 mg. Choose sample volume to yield between 2.5 and 200 mg dried residue. This establishes a minimum reporting value of 2.5 mg/L when 1000 mL of sample is analyzed. If complete filtration takes more than 10 minutes increase filter diameter or decrease sample volume. In instances where the weight gain is less than the required 2.5 mg, the value must be reported as less than the appropriate value based upon the volume used. Ref: North Carolina Wastewater/Groundwater Laboratory Certification Policy based upon Standard Methods, 20th and 21st Editions, 2540 D. (3) (b). Comment: For example, if 500 mL of sample is analyzed and < 2.5 mg of dried residue is obtained, the value reported would be < 5 mg/L. IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing laboratory benchsheets and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Quality. Data were reviewed for June, October and November, 2011. The following errors were noted: Date Parameter Location Value on Benchsheet Value on DMR 6/1/11 TSS Effluent 14.2 mg/L — 166.2 lb/day 3/6 mg/L — 42.1 lb/day 6/20/11 Fluoride Effluent 7.36 mg/L — 80.8 lb/day 7.86 mg/L — 86.3 lb/day 6/24/11 pH Effluent 8.6 SU 7.2 SU 6125/11 pH Effluent 7.4 SU 8.3 SU 6/30/11 Fluoride Effluent 8.24 mg/L — 82.7 lb/day 8.20 mg/L — 82.3 lb/day 10/2/11 Fluoride Effluent 9.8 mg/L — 102.1 lb/day 9.4 mg/L — 97.8 lb/day 10/5/11 Turbidity Effluent 2.3 NTU 2.9 NTU 10/6/11 Turbidity Effluent 2.8 NTU 2.3 NTU Page 5 #555 Unimin Schoolhouse Quartz Plant 10/7/11 Turbidity Effluent 3.6 NTU 3.9 NTU 10/11/11 Turbidity Effluent 4.4 NTU 3.4 NTU 10/14/11 Fluoride Effluent 8.4 mg/L - 101.3 lb/day 8.0 mg/L - 96.5 lb/day 10/15/11 Fluoride Effluent 8.7 mg/L - 97.9 lb/day 8.8 mg/L - 98.9 lb/day 10/16/11 Fluoride Effluent 8.4 mg/L - 89.7 lb/day 8.5 mg/L - 90.3 lb/day 10/17/11 Fluoride Effluent 8.6 mg/L - 89.5 lb/day 8.8 mg/L - 91.3 lb/day 10/18/11 Turbidity Effluent 2.3 NTU 2.8 NTU 10/19/11 Turbidity Effluent 2.9 NTU 2.0 NTU 10/19/11 Fluoride Effluent 9.8 mg/L - 93.4 lb/day 9.0 mg/L - 75.1 lb/day 10/20/11 Turbidity Effluent 2.6 NTU 9.0 NTU 10/20/11 Fluoride Effluent 9.3 mg/L - 99.4 lb/day 9.9 mg/L - 105.9 lb/day 10/21/11 Fluoride Effluent 9.9 mg/L - 69.8 lb/day 9.2 mg/L - 66.5 lb/day 10/25/11 Turbidity Effluent 4.8 NTU 4.2 NTU 10/25/11 Fluoride Effluent 8.9 mg/L - 98.5 lb/day 8.6 mg/L - 84.2 lb/day 10/26/11 Turbidity Effluent 2.0 NTU 2.8 NTU 10/28/11 Turbidity Effluent 2.2 NTU 2.8 NTU 10/28/11 Fluoride Effluent 8.7 mg/L - 105.3 lb/day 8.6 mg/L - 103.8 lb/day 10/30/11 Fluoride Effluent 8.6 mg/L - 90.2 lb/day 8.0 mg/L - 83.9 lb/day 11 /9/11 pH Effluent 8.6 SU 8.0 SU 11/16/11 Turbidity Effluent 8.7 NTU 3.7 NTU 11/24/11 Turbidity Effluent 2.8 NTU 3.8 NTU 11/27/11 Fluoride Effluent 9.4 mg/L - 104 lb/day 9.1 mg/L - 100.5 lb/day Due to the unusual number of transcription errors, the Asheville Regional Office has requested amended DMRs for June, October, and November, 2011. V. CONCLUSIONS: Correcting the above -cited findings and implementing the recommendations will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance during the inspection and data review process. Please respond to all findings. Report prepared by: Jason Smith Date: April 18, 2012 Report reviewed by: Todd Crawford Date: April 19, 2012