HomeMy WebLinkAboutWQ0043908_Correspondence_20230112Strickland, Bev
From: Zach Hinnant <zhinnant@crupumps.com>
Sent: Thursday, January 12, 2023 2:16 PM
To: Robinson, Jason
Cc: mary.depina; Kurtz, Cassidy
Subject: [External] RE: WQ0043908 Permit
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Sounds great, thanks Jason.
From: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Sent: Thursday, January 12, 2023 2:10 PM
To: Zach Hinnant <zhinnant@crupumps.com>
Cc: mary.depina <mary.depina@sanfordnc.net>; Kurtz, Cassidy <Cassidy.Kurtz@ncdenr.gov>
Subject: RE: WQ0043908 Permit
Sound good Zach, I plan to issue a corrected permit that shows 812 GPM.
We don't see too many applications for triplex pumps, and the application isn't very clear about how the operational
point should be specified.
Jason T. Robinson, P.E.
Raleigh Regional Office
Water Quality Regional Operations
NC Division of Water Resources, DEQ
919-791-4200
**Subscribe to Collection System & Sewer Permitting Updates**
11 E
NORTH CAROLINA \ CO
Department of Environmental Duality
Email correspondence to and from this address is subject to the North
Carolina Public Records Law and may be disclosed to third parties.
From: Zach Hinnant <zhinnant@crupumps.com>
Sent: Thursday, January 12, 2023 2:07 PM
To: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Cc: mary.depina <mary.depina@sanfordnc.net>
Subject: RE: [External] WQ0043908 Permit
1
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Correct.
From: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Sent: Thursday, January 12, 2023 1:09 PM
To: Zach Hinnant <zhinnant@crupumps.com>
Cc: mary.depina <mary.depina@sanfordnc.net>
Subject: RE: [External] WQ0043908 Permit
Hi Zach,
I just want to make sure I'm understanding. Does the pump station pump 812 GPM with two pumps pumping
simultaneously (and largest pump out of service).
Jason T. Robinson, P.E.
Raleigh Regional Office
Water Quality Regional Operations
NC Division of Water Resources, DEQ
919-791-4200
**Subscribe to Collection System & Sewer Permitting Updates**
Et E CO
NORTH CAROLINA
Department of Environmental Quality
Email correspondence to and from this address is subject to the North
Carolina Public Records Law and may be disclosed to third parties.
From: Zach Hinnant <zhinnant@crupumps.com>
Sent: Tuesday, January 10, 2023 4:18 PM
To: Robinson, Jason <jason.t.robinson@ncdenr.gov>
Cc: mary.depina <mary.depina@sanfordnc.net>
Subject: [External] WQ0043908 Permit
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Hello Jason,
Regarding the attached permit and fast track application: myself and the City have a question:
2
- On the FTSA, page 6 (Section VIII.3), I indicated the total number of pumps at the pump station as 3,
and the design flow of the pump station to be 1.17MGD firm capacity.
- On the next line, I indicated the Operational Point per Pump as 760GPM. As, per my report, this is
what (1) pump will pump.
- But, on page 3 of the attached permit, it states "the construction and operation of a 760GPM pump
station with triplex pumps". Shouldn't this indicate the pump station at its firm capacity of 1.17MGD
(8112GPM)?
We need the pump station to be permitted for the firm capacity so the city can satisfy guarantees developers
have asked for.
Please let me know if this was a mistake in the permit, or if I filled out that section of the FTSA incorrectly and
what the easiest way to correct this will be.
Thanks!
Zach C. Hinnant, PE
Charles R. Underwood, Inc.
Office: 919.775.2463
Cell: 919.219.9261
3