Loading...
HomeMy WebLinkAboutSW6110103_O&M Agreement_20110201Permit Number: (to be provided by DWQ) Drainage Area Number: Infiltration Trench Operation and Maintenance Agreement I will keep a maintenance record on this BMP. This maintenance record will be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the removal efficiency of the BMP. Important maintenance procedures: — The drainage area of the infiltration trench will be carefully managed to reduce the sediment load to the sand filter. — The water level in the monitoring wells will be recorded once a month and after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal Comity). The infiltration trench will be inspected once a quarter and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County). Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potentialproblem: How I will remediate theproblem: The entire BMP Trash debris is present. Remove the trash debris. The grass filter strip or Areas of bare soil and/or Regrade the soil if necessary to other pretreatment area erosive gullies have formed. remove the gully, and then plant a ground cover and -water until it established. Provide lime and a one-time fertilizer application. Sediment has accumulated to Search for the source of the a depth of greater than six sediment and remedy the problem if inches. possible. Remove the sediment and dispose of it in a location where it will not cause impacts to streams or the BMP. The flow diversion The structure is clogged. Unclog the conveyance and dispose structure (if applicable) of any sediment off -site. The structure is damaged. Make any necessary repairs or replace if damage is too large for repair. J Form SW401 -I nfiltration Trench O&M-Rev.3 Page I of 3 BMP element: Potentialproblem: How I will remediate theproblem: The trench Water is pending on the surface for more than 24 Remove the accumulated sediment from the infiltration system and hours after a storm. dispose in a location that will not impact a stream or the BMP. The depth in the trench is Remove the accumulated sediment reduced to 75% of the original from the infiltration system and design depth. dispose in a location that will not impact a stream or the BMP. Grass or other plants are Remove the plants, preferably by growing on the surface of the hand. If pesticide is used, wipe it on trench. the plants rather than s ra in . The observation well(s) The water table is within one Contact the DWQ Stormwater Unit foot of the bottom of the immediately at 919-733-5083. system for a period of three consecutive months. The outflow pipe is clogged. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. The outflow pipe is damaged. Repair or replace the pipe. The emergency overflow Erosion or other signs of The emergency overflow berm will berm damage have occurred at the be repaired or replaced if beyond outlet. repair. The receiving water Erosion or other signs of Contact the NC Division of Water damage have occurred at the Quality 401 Oversight Unit at 919- outlet. 1 733-1786. Form SW401-Infiltration Trench O&M-Rev.3 Page 2 of 3 Permit Number: (m be provide(i by UIVQ) acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed above. 1 agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Project name:JSOC, SIDE C4 Facility (LI 66362) BMP drainage area number: Print name:Mr. Craig Lantz Title:Water Management Branch Chief(WMB) Address:Bldg. 0-9125 McKellars Road, Fort Bragg, NC 28310 Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. a Notary Public for the State of County of , do hereby certify that personally appeared before me this day -of , and acknowledge the due execution of the forgoing infiltration trench maintenance requirements. Witness my hand and official seal, SEAL My commission Form SW401-Infiltration Trench O&M-Rev.3 Page 3 of 3