HomeMy WebLinkAboutRE_ C204553 78_ RCP As-builtFrom:Lane, Stephen
To:Sprinkle, Hannah H; Farrell, Sean C; Steffens, Thomas A CIV USARMY CESAW (USA)
Cc:Westphal, Anneliese
Subject:RE: C204553 78" RCP As-built
Date:Wednesday, January 11, 2023 3:37:01 PM
Attachments:image001.png
image002.png
DCM concurs with the DWR’s comments listed below.
From: Sprinkle, Hannah H <hannah.sprinkle@ncdenr.gov>
Sent: Wednesday, January 11, 2023 3:30 PM
To: Farrell, Sean C <scfarrell@ncdot.gov>; Steffens, Thomas A CIV USARMY CESAW (USA)
<thomas.a.steffens@usace.army.mil>; Lane, Stephen <stephen.lane@ncdenr.gov>
Cc: Westphal, Anneliese <awestphal@ncdot.gov>
Subject: RE: C204553 78" RCP As-built
Sean,
I’m open to continuing to monitor the situation, in hopes the outlet will naturally fill in over time.
Going forward, I hope the contractors will take extra precaution with any excavation that is needed.
Thank for keeping us in the loop,
Hannah
From: Farrell, Sean C <scfarrell@ncdot.gov>
Sent: Wednesday, January 11, 2023 8:32 AM
To: Steffens, Thomas A CIV USARMY CESAW (USA) <thomas.a.steffens@usace.army.mil>; Sprinkle,
Hannah H <hannah.sprinkle@ncdenr.gov>; Lane, Stephen <stephen.lane@ncdenr.gov>
Cc: Westphal, Anneliese <awestphal@ncdot.gov>
Subject: FW: C204553 78" RCP As-built
Tom, Hannah, and Stephen
Please see the below email from Ben and the as-built elevations of the 72” RCP. It appears the pipe
inverts where set at the correct elevations, but the ditch was slightly over excavated (possibly a
result of loss retrieval efforts). Mason and I have discussed this and we would like to avoid the
contractor having to go in and regrade the ditch at this stage. We think the pipe is buried enough on
the inlet and being that it is about at grade on the outlet, it should continue to accrete sediment
over time. We would like to continue to monitor this instead of taking immediate corrective action if
you are in agreeance. Please let me know your thoughts on this.
Thanks,
Sean Farrell
GIS Analyst
Division 3
NCDOT- Division of Highways
910-341-2033 office
910-599-1184 mobile
scfarrell@ncdot.gov
5501 Barbados Blvd
Castle Hayne, NC 28429
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
From: Meyer (RK & K Civil Engineering), Benjamin C <ext-bcmeyer1@ncdot.gov>
Sent: Tuesday, January 10, 2023 1:51 PM
To: Farrell, Sean C <scfarrell@ncdot.gov>
Cc: Westphal, Anneliese <awestphal@ncdot.gov>; Gingrich, Sophia E <segingrich@ncdot.gov>;
Waugh, Daniel G <dgwaugh1@ncdot.gov>; Jackson Provost, PE, PLS
<Jackson.Provost@summitde.com>; Brandon Helms <brandon.helms@summitde.com>
Subject: C204553 78" RCP As-built
Sean,
Attached and below are the as-builts for the inverts of the ditch and 78” pipe at the US17 area. The
inverts and outlet have been over excavated during the retrieval of the sediment from the storm
event that occurred 12/22/2022 -12/23/2022. Concerns if we add material:
Inlet side will creating a head cut with most of the material washing into the pipe until an
equilibrium is met.
Outlet side adding material will impound water inside of the pipe.
There was not a note or provision to place material inside of the pipe to help equalize the
system
The typical Safe Passage Requirements for Culvert Placement permit provision was not included in
the C204553 Permits. To date the Conti has been submitting their drainage investigations for review,
which are meeting the Safe Passage Requirements for Culvert Placement.
Please advise if corrective action or monitoring of the area is required. Let us know if there is any
additional information needed.
Point Name Northing Easting Elevation Point Code
1 238759.614 2399860.25 34.814 Invert Out Pipe
2 239166.444 2400004.239 36.047 Invert In Pipe
3 238750.7 2399856.938 34.867 out - 10'
4 238740.679 2399854.203 34.803 out - 20'
5 238729.534 2399851.255 34.584 out - 30'
6 239175.397 2400010.492 36.212 inlet - 10'
7 239184.057 2400016.344 36.43 inlet - 20'
8 239192.39 2400022.265 36.604 inlet - 30'
Cheers,
Ben
Ben Meyer, PE, CCM
Assistant Resident Engineer
Hampstead Bypass
Cell: 910-617-1902
Ext-bcmeyer1@ncdot.gov
bmeyer@rkk.com
From: Hunter Livingstone <hlivingstone@conticivil.com>
Sent: Monday, January 9, 2023 6:57 AM
To: Meyer, Benjamin C <ext-bcmeyer1@ncdot.gov>
Cc: Bryce Locke <blocke@conticivil.com>; Brandon Ulishney <bulishney@conticivil.com>; James Day
<jday@conticivil.com>; John Kristensen <jkristensen@conticivil.com>; Michael Sullivan
<msullivan@conticivil.com>; Zachary Fuller <zfuller@conticivil.com>; Brandon Helms
<brandon.helms@summitde.com>; Jackson Provost, PE, PLS <Jackson.Provost@summitde.com>
Subject: RE: [External] 78" RCP As-built
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an
attachment to Report Spam.
Ben,
Please see attached information along with table below. Let me know if you have any questions.
Point Name Northing Easting Elevation Point Code
1 238759.614 2399860.25 34.814 Invert Out Pipe
2 239166.444 2400004.239 36.047 Invert In Pipe
3 238750.7 2399856.938 34.867 out - 10'
4 238740.679 2399854.203 34.803 out - 20'
5 238729.534 2399851.255 34.584 out - 30'
6 239175.397 2400010.492 36.212 inlet - 10'
7 239184.057 2400016.344 36.43 inlet - 20'
8 239192.39 2400022.265 36.604 inlet - 30'
CAUTION: This email originated from outside of the organization. Use caution when clicking links or opening
attachments. The sender may not be who they appear to be.
Hunter Livingstone | Project Engineer
18087 U.S. 17
Hampstead, NC 28443
o. 910.524.2234 | m. 910.524.2234
hlivingstone@conticivil.com
Done Once, Done Right
ContiCivil.com | Facebook | LinkedIn
a member of The Conti Group
From: Meyer, Benjamin C <ext-bcmeyer1@ncdot.gov>
Sent: Friday, January 6, 2023 9:01 AM
To: Hunter Livingstone <hlivingstone@conticivil.com>
Cc: Bryce Locke <blocke@conticivil.com>; Brandon Ulishney <bulishney@conticivil.com>; James Day
<jday@conticivil.com>; John Kristensen <jkristensen@conticivil.com>; Michael Sullivan
<msullivan@conticivil.com>; Zachary Fuller <zfuller@conticivil.com>; Brandon Helms
<brandon.helms@summitde.com>; Jackson Provost, PE, PLS <Jackson.Provost@summitde.com>
Subject: RE: [External] 78" RCP As-built
Hunter,
That provides us the information for the 78” pipe invert is correct per the accepted drainage
investigation. As noted in the plans and drainage investigation the pipe is supposed to be buried 1’
as part of the environmental requirement. We also need the grades shot at least every 10’ for
approximately 30’ from the invert and outlet. During the retrieval of the sediment after the rain
event on 12/22-12/23 the area may have been over excavated. Currently, it appears that the ditches
on either side of the pipe were graded to match the invert of the pipe. Please provide us with the
additional information for the ditch grades. Let us know if you have any questions.
Cheers,
Ben
Ben Meyer, PE, CCM
Assistant Resident Engineer
Hampstead Bypass
Cell: 910-617-1902
Ext-bcmeyer1@ncdot.gov
bmeyer@rkk.com
From: Hunter Livingstone <hlivingstone@conticivil.com>
Sent: Friday, January 6, 2023 8:38 AM
To: Meyer, Benjamin C <ext-bcmeyer1@ncdot.gov>
Cc: Bryce Locke <blocke@conticivil.com>; Brandon Ulishney <bulishney@conticivil.com>; James Day
<jday@conticivil.com>; John Kristensen <jkristensen@conticivil.com>; Michael Sullivan
<msullivan@conticivil.com>; Zachary Fuller <zfuller@conticivil.com>; Brandon Helms
<brandon.helms@summitde.com>
Subject: [External] 78" RCP As-built
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an
attachment to Report Spam.
Ben,
Please see attached CSV file from as-built on 78” RCP pipe run 2304.
Point Name Northing Easting Elevation Point Code
1 238759.6 2399860 34.814 Invert Out
2 239166.4 2400004 36.047 Invert In
Any questions please let me know.