Loading...
HomeMy WebLinkAboutGW95042/DEH95-06_Correspondence_19950609State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director MEMORANDUM TO: THROUGH: FROM:' SUBJECT: AWA EDEHNFi GROUNDWATER SECTION June 9, 1995 xECEIVEn Stacy Covil, Head (Acting) On -Site Wastewater Section JUN 14 1995 Bob Cheek 12_47L Brian Wagner a-�-- Eckerd Youth Camp Subsurface Disposal Bladen County DEH95-06/GW95042 ( Victor D'Amato : Review Engineer ) nta. MANAGEMENT FMIE./.ILLE REG. OFFICE! The Groundwater Section has reviewed the subject permit application. The system is designed to treat and dispose of 10,000 GPD (gallons per day) at a loading rate of 0.6 gallons per day per foot squared. The'system will consist of septic tanks at each camp building, a grease trap will be added to the administration building where the kitchen is to be located, all collected into one forcemain and pumped approximately 4500 feet southwest of the camp into a dosing chamber with dual siphons which will dose two subsurface absorption fields with 2,800 feet of lateral drainfield pipe and an application area of 16,666 squared feet. We recommend issuance of the permit with the following conditions: 1. Any groundwater quality monitoring, as deemed necessary by the Division, shall be provided. 2. The COMPLIANCE BOUNDARY for the disposal system is specified by regulations in 15A NCAC 2L, Groundwater Classifications and Standards. The Compliance Boundary for disposal systems constructed after December 31, 1983 is established at the property boundary. An exceedance of Groundwater Quality Standards at or beyond the Compliance Boundary is subject to immediate remediation action in addition to the penalty provisions applicable under General Statute 143-215.6A(a)(1). 3. In accordance with 15A NCAC 2L, a REVIEW BOUNDARY is established around the disposal systems midway between the Compliance Boundary and the perimeter P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015, FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper of the waste disposal area. Any exceedance of standards at the Review Boundary shall require remediation action on the part of the permittee. cc: Jim Bales= Central Files Permit Files baw/95042.doc tH DIVISION OF ENVIRONMENTAL MANAGEMENT MEMORANDUM TO: April 27, 1995 Brian Wagner, Groundwater Section Raleigh Central Office THROUGH: Jim Bales, Groundwater Section Fayetteville Regional Office FROM: Michael Linscott, Groundwater Secti Fayetteville Regional' Office SUBJECT: Eckerd Youth Comp. Subsurface Disposal System, New Permit Application GW95042 DEH95-06 Bladen County The subject new permit application has been reviewed by the FRO Groundwater Section. In the permit application, it is stated that 10,000 gallons per day will be generated by the subject facility. However, in the "Soil Site Evaluations,Hydraulic Measurements and Mounding Analysis" all of the calculations use 5,000 gallons per day. We re -ran the calculations using 10,000 gpd, and it appears that the system will still adequately handle the 10,000 gpd. I felt that this significant difference in gallons per day generated needed to be brought to your attention. Theonly problem associated with the system is its close proximity to the property line, and associated compliance and review boundaries. It is likely that with any impact to the groundwater--, a compliance boundary violation will also have occurred. Despite this, the subsurface disposal system's location has many positive aspects. There are no 'threatening receptors in the anticipated direction of flow from the disposal field. The disposal field is very remote to all threatening receptors except the camp itself which is approximately 4,000 feet away. No groundwater monitoring in necessaryfor this site at this time. If you have any questions, please call me at (910) 486-1541. JTB/MWL GROUNDWATER SECTION GW # DIVISION OF ENVIRONMENTAL MANAGEMENT 1504-1 RECORD OF WASTE DISPOSAL PERMIT APPLICATION REVIEW REVIEW BY A \L DATE LI—ZS-gt FIELD INVESTIGATION? (YIN) ( FACILITY NAME E- COUNTY - g let Gh . LOCATION - Z\ 1 a S SVA\ TYPE OF DISPOSAL SYSTEM (LAGOON, ETC.) eSo\c, Sot - &ySt•er, CAP. (GPD) 10, D 0 n DESCRIPTION OF FACILITY Astir � c e: DL`spos� \ s 5��+.. pESIGN i ,i ,Pa T-Or j- r4.1 I.-M.? es ;- pc I4Ayr11,4 f erZ. qcou CA..P SIZE OF IMPOUNDMENT (FT. SQ) IIo) ID (a flZ. &/OR SIZE -OF APPLICATION AREA WASTE SOURCE: MUN. SLUDGE MUN. W. WATER: �RIMARY SECONDARY TERTIARY IND. SLUDGE IND: WELL WATER —OTHERS: DISTANCE FROM WASTE SOURCE TO NEAREST: STREAM 2000 FT., WELL rOr) FT. FOR WELL: TYPE OF USE )1,Pd1y , DEPTH PUMP RATE (EST.) WHAT DESIGN CONDITIONS WILL REDUCE/ CREASE` HANCE OF GW TCONTAMINATIO IN• 71LC- € � �.-L. o F /�ODO 6- Inn. (u�-SY y�,c�-.. rrtite.�� pr`�t-'f L. �� SI►^� 4 Ryi_ WHAT NATURAL SITE COIN,DITION WILL RkDUC CREAS CHANCE OF GW CONTAMINATION. 14 %citti (( C DEPTH TO: BEDROC 7 �S FT., SEASO AL HIGH W.T. FT., ANNUAL W.T. FLUX 3 FT. SURFICIAL AQUIFER BEDROCK/ARTESIAN AQUIFER GEN. LITHOLOGY 1 k y HYD. COND. /0- - i /DAY ❑MEASURED E MEASURED [}-ESTiMATED FT./DAY ESTIMATED THICKNESS FT NO. OF MONITER.WELLS: PROPOSED: UP g DOWN 9 ; EXISTING: UP DOWN p FROM WORKSHEET: SITE NUMERICAL DESCRIPTION= - - - 6 b, A A T 1 2 3 4' 5 6 6A 6B SITE GRADE (HYDROGEOL) = SITUATION GRADE= PROPOSED SAMPLING SCHEDULE & PARAMETER(S): I70 SQ..- j-ref �1r- d_ f - S.p- HAVE-THERE BEEN ANY EXCEEDANCES OF THE GROUNDWATER STANDARDS? YES NO HAS ANY ENFORCEMENT ACTION BEEN TAKEN? YES NO --- DATE OF ACTION. BRIEF SUMMARY OF ENFORCEMENT ACTION TAKEN. - REMARKS/ RECOMMENDATIONS (Continue on reverse, if necessary): S c-r cc I lAuLi M Pro GW-48 Revised 04/94 HYD. REGIONAL UP RVISOR SUM am 7&/P S • TO: DATE: DIVISICN OF E VIRCNMEWTAL MANAGEME I' GROUNr A'u R SECTION /0 A.6 /99S- FROM: Jack Floyd SUBJECT: Application for RENEWAL/AMENDMENT of Permit No. ,A NEW PEST EC I FEB 2 i. 1995 ENV. MANAGEMENT FAYETTEVILLE REG.. OFFICE Facility Name: C 5 Cas./p County: d oe' Type of Project: Central Office Contact: 6&Via h &)a i h.ek Applicable Permit Numbers: 199 Gig 9,5-0 e/2 DELI qs-o , AC EPA The Groundwater Section has received a copy of the above referenced permit application. A copy of the application package is attached. The Groundwater Section has received a copy of the above referenced permit application, which has been sent to the regional office water quality supervisor. If a copy has not been sent to the regional office p1e se let me know. The Groundwater Section has received the subject Division of --;Environmental Health project for review. A copy of the application has been forwarded to e,/ Cau, p4n , Regional Soil Specialist. Please coordinate your review with the regional soil specialist. 4/0- 1,46 //91 Please review the application materials for completeness and submit .. any request for additional information to the central.office contact on or before)6 . A copy of the formal request for additional information will be forwarded to you. If you do not require any arlai tional information to complete your review, please provide your final comments by JL 13 . If you have any questions, please let me know as soon as possible.