Loading...
HomeMy WebLinkAbout#559_2017_0908_BS_FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: 559 Laboratory Name: K & W Laboratories Inspection Type: Abbreviated Commercial Maintenance Inspector Name(s): Beth Swanson Inspection Date: September 8, 2017 Date Forwarded for Initial Review: September 20, 2017 Initial Review by: Anna Ostendorff Date Initial Review Completed: September 20, 2017 Cover Letter to use: ❑ Insp. Initial ®Insp. No Finding ❑Corrected ❑ Insp. Reg ❑Insp. CP ❑Insp. Reg. Delay Unit Supervisor/Chemist III: Dana Satterwhite Date Received: September 21, 2017 Date Forwarded to Admin.: September 22, 2017 Date Mailed: September 26, 2017 Special Mailing Instructions: Water Resources ENVIRONMENTAL QUALITY September 26, 2017 559 Ms. Gosia Kraska K & W Laboratories 1121 Hwy. 24/27 W Midland, NC 28107 ROY COOPER M, : ") MICHEAL S. REGAN iarr S. JAY ZIMMERMAN Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Ms. Kraska: Enclosed is a report for the inspection performed on September 8, 2017 by Beth Swanson. No Findings are cited in this report, a response is not required. We appreciate the fine job you and your staff are doing. As a Certification requirement, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. A copy of the laboratory's Certified Parameter List at the time of the audit is attached. This list will reflect any changes made during the audit. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact me at (828) 296-4677. Sincerely, Dana Satterwhite, Environmental Program Supervisor Division of Water Resources Attachment cc: Beth Swanson, Master File #559 Water Sciences Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road, Raleigh, North Carolina 27607 Phone, 919-733-3908 FAX, 919-733-6241 Internet; http://deq.nc.goviabouUdiv€sionstwater-resources/water•resources-datalwater-sciences-home•Dage/laboratont-certification-branch • • a . • • LABORATORY NAME: K & W Laboratories ADDRESS: 1121 Hwy 24/27 W Midland, NC 28107 CERTIFICATE #: 559 DATE OF INSPECTION: September 8, 2017 TYPE OF INSPECTION: Abbreviated Commercial Maintenance AUDITOR(S): Beth Swanson LOCAL PERSON(S) CONTACTED: Szymon Kraska and Gosia Kraska INTRODUCTION: This laboratory was inspected by a representative of the North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) program to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. GENERAL COMMENTS: This was an abbreviated audit of E. Coli analyzed by SM 9223 B-2004 (IDEXX Colilert-18®) (MPN) (Aqueous) conducted via internet video and a desk review of the benchsheet with Proficiency Testing (PT) data. The laboratory requested the audit to fulfill a requirement needed to gain Certification for the parameter with the South Carolina Department of Health and Environmental Control. The parameter was added to the laboratory's NC WW/GW LC Certified Parameter Listing (CPL) on August 4, 2017. They have yet to analyze any compliance samples. The facility has all the equipment necessary to perform the analysis. All required PT Samples have been analyzed and the laboratory has fulfilled its PT requirements for the 2017 PT Calendar Year. The method Standard Operating Procedure (SOP) was originally submitted with the amendment request and was subsequently reviewed and updated as needed before the parameter was certified. The laboratory is reminded that any time changes are made to laboratory procedures, the laboratory must update the QA/SOP document(s) and inform relevant staff. Any changes made in response to the pre -audit review or to Findings, Recommendations or Comments listed in this report must be incorporated to insure the method is being performed as stated, references to methods are accurate, and the QA and/or SOP document(s) is in agreement with each approved practice, test, analysis, measurement, monitoring procedure or regulatory requirement being used in the laboratory. In some instances, the laboratory may need to create an SOP to document how new functions or policies will be implemented. The laboratory is also reminded that SOPs are intended to describe procedures exactly as they are to be performed. Use of the word "should" is not appropriate when describing requirements Page 2 #559 K & W Laboratories (e.g., Quality Control (QC) frequency, acceptance criteria, etc.). Evaluate all SOPs for the proper use of the word "should". III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Bacteria - E. Coli — Standard Methods, 9223 B-2004 (IDEXX Colilert-180) (MPN) (Aqueous) Comment: The Quanti-Tray® sealer had not been tested with dye to check for leaks prior to the inspection. This is required monthly by NC WW/GW LC Policy. As stated previously, no compliance samples have been analyzed and documentation of an acceptable sealer check was received by email on September 9, 2017. IV. PAPER TRAIL INVESTIGATION: No paper trail was performed since the laboratory has not generated any data beyond the PT sample. V. CONCLUSIONS: No Findings were noted during the inspection. The inspector would like to thank the staff for their assistance during the inspection and data review process. No response is required. Report prepared by: Beth Swanson Date: September 19, 2017 Report reviewed by: Anna Ostendorff Date: September 20, 2017