Loading...
HomeMy WebLinkAboutSW1170501_Supplement-EZ Form_20221223SUPPLEMENT-EZ COVER GAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Acony Bell - PH3 2 Project Area ac 50,Oac 3 F5 Coastal Wetland Area ac 0 4 Surface Water Area ac 0.5 Is this project High or Low Density? Low 6 1 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feetl. 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is pfoposed in the setback, does It meet NCAC 02H.1003 4 Gd ? Yes 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: Infiltration System 0 BioretentlonCell 0 F15 Wet Pond 0 Stormwater Wetland 0 Permeable Pavement 0 Sand Filter 0 17 Rainwater HarvestingRWH 0 F16 18 Green Roof 0 19 Level Spreader -Filter StripLS-FS 0 24 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dy Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Eric J. Hutchison lil, PE 28 organization: Brooks Engineering Associates 29 Street address; 15 Arlington St 30 City, State, Zip: Asheville, NC 28801 31 Phone numbers : 828 232-4700 32 Email: ehutchison@brooksea.com Certlficallon Statement: I certify, under penally of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the Information provided here, \\\��'owl CI II r/w/77ARO 7/// SSjpN`�'yy�'%� SEAL 051824 �A.• 1ZI22 �� HUT COs����`��� 4 Signature of DeYlgner " — L Date f Is this a htA h density ro'eci? No 2 If so, number of drainage areaslSCMs 0 3 Does this project have low density -areas? Yes 4 5 If so, number of tow density drainage aroas Is aHlparf of this project subject to previous rule versions? 1 No -__ _..... FORMS LOADED DRAINAGE AREA INFORMATION Entire Site , 4 Type of SCM NIA _ NIA _ 5 Total draina a area s It 2,178,OOOsf_ _ 2,17_8,000sf 6 Onsite draina a area s ft ___ 2,178,OOOst 2,178,000sf 7_ Offsiie drainage reAkq ft) Osf Osf _202,870sf 202,870sf _ _8 _Total BUA inro'eci soft) _ _ New BUA on subdivided lots (subject to _9 permiitin (sgftj--- -- __.--------_- _m NIA -- NIA _.. New BUA not on subdivided lots (subject to 10_ Rermitti��jsf)_...._ 202,870sf 202,870sf 05f Osf 12 Breakdown of new BUA not on subdivided lots: _ Parkin0 (sgft) 50,239sf 50,239sf Sidewalk Csq ft) - Osf Osf Raaf s ft q- 50,957sf 50,957sf_ - --_t Roadwa s ft 100,553sf 100,553sf - Future (sg ft)- ,_._„ __._ Osf Osf - Other, please specify In the comment box below s ft) _ 1121 sf m _ 11_21 sf New infiltrating permeable pavement on 13 subdivided lots s ft osf _ Osf New infiltrating permeable pavement not on 14 subdivided lots s 1t —_ Osf Osf Existing BUA that will remain (not subject to 15 erp mittinqJ s ft _ Osf —Osf 16 Exist€ng BUA that is alreadypermitted (sq ft)____. 17 Existing BUA that will be removed s ft) Osf Osf 18 Porceni BUA - 9% 9% 19 __„ Dosi n storm (inches NIA NIA 20 Design volume of SCM (cuff)_ N1A NIA 21 Calculation method for design volume NIA NIA ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Other BUA is common space amenities (eg. fire ring and pavers), LOW DENSITY