Loading...
HomeMy WebLinkAbout20210256 Ver 1_12-02-22 On-Site Meeting - Follow up Summary_20221221Baker, Caroline D From: Andrew Grant <AGrant@bgeinc.com> Sent: Wednesday, December 21, 2022 11:53 AM To: Jamie Hopkins; Chad Waldrup Cc: Brian Collins; Brower, Taylor; Thomas Garrison; joseph.alm; Hoy, Joseph K; Pitner, Andrew Subject: [External] RE: Harper Landing 12-02-22 On -Site Meeting - Follow up Summary Attachments: 2022-1220 - EC Observations - Harper Landing.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. All, Good morning. Please see the attached EC plan with markups from the two BGE Site Visits and the additional erosion control measures installed by JE Jenkins and documented below. If the attached is agreeable to everyone, we will ensure this gets included in the SWPPP with a copy kept onsite. Thanks, Andrew Grant, PE Director, Land/Site Associate Main: 980-220-2322 Cell: 803-322-7510 Serving. Lf,,,�ding. Sviving." From: Jamie Hopkins <JamieH@jejenkins.com> Sent: Thursday, December 15, 2022 7:21 AM To: Chad Waldrup <Chad.Waldrup@gastongov.com> Cc: Brian Collins <Brian.Collins@meritagehomes.com>; Brower, Taylor <taylor.brower@meritagehomes.com>; Thomas Garrison <ThomasG@jejenkins.com>; Andrew Grant <AGrant@bgeinc.com>; Joseph D. Alm <Joseph.Alm@gastongov.com>; joseph.hoy@ncdenr.gov; andrew.pitner@ncdenr.gov Subject: Re: Harper Landing 12-02-22 On -Site Meeting - Follow up Summary Chad just wanted to shoot you some pictures of progress. 2 3 icy - r_ - � _ .'L-t. h' .�`f i riJ f '� n �f ri Y�IJ77 �F'' _ .:+�t�.a�l� 1. - �: El Ord'- /' -I 6 7 -Olt Z,. MA ,�ft -% I WNW -9r." Weal" Prey, 10 L # i 4 T��y 4L 12 13 14 15 I Jamie Hopkins Superintendent John E. Jenkins Inc. M— 912-665-5754 iamieh @ie'enkins. com On Dec 6, 2022, at 3:22 PM, Jamie Hopkins <JamieH@ieienkins.com> wrote: Chad, just a follow up with you. We got the berm and All done at pond one and a few more diversion out in. Also most of silt fence repaired. We still have several things to complaint but Mother Nature is mad at us at the moment. Jamie Hopkins Superintendent 16 John E. Jenkins Inc. M— 912-665-5754 jamieh@ieienkins.com On Dec 6, 2022, at 3:01 PM, Chad Waldrup <Chad.Waldrup@gastongov.com> wrote: 0 This email is a follow up summary of the on -site meeting and site visit held on Friday December 2nd, 2022. The site is currently under a Notice of Violation (NOV) and remains under an NOV status. Below is a list of observations made by Gaston County Natural Resources Staff: 1. Observed additional sedimentation migration past limits of disturbance into a previously impacted and noted wetland and intermittent stream located between Basin 1 and Basin 2. The intermittent stream was flowing with no blockages comprised of sediment; however, pockets of sediment lined the channel downstream to the confluence with South Stanley Creek. Majority of the sediment deposition was located on property between Basin 1 and 2. No sediment deposition was observed at the confluence or in South Stanley Creek beyond the confluence. However, turbidity was present in South Stanley Creek. 2. Observed sedimentation migration past limits of disturbance along perimeter measures (mainly at silt fence outlets) along the southside of South Stanley Creek. No sediment deposition was visible in South Stanley Creek, however there were pockets of sediment deposition between perimeter measures and the top of bank. 3. Sediment basins 1, 2, 3, and 7 were all discharging via their respective skimmer devices. Sediment Basin 7 discharge was crossing an area of disturbed site and exiting the site via silt fence outlets into South Stanley Creek. 4. Efforts to clean up sediment past limits of disturbance were underway by crews utilizing shovels and buckets. 5. Efforts to remove accumulated sediment along interior of perimeter measures were underway. Summary of discussions and recommendations on moving forward with the project: 1. Design Engineer to submit revisions on additional measures to be utilized in problem areas of site and verify additional measures already in place. 2. Ensure all diversion ditches are functioning per design and draining to sediment basins. Utilize temporary pipes to cross diversion ditches. 3. Ensure sediment basins are functioning properly. Basin 7 ensure north -facing dam is higher than emergency spillway, correct any low spots in top of dam, and verify skimmer orifice size in skimmer device is per design. 4. Offsite water (i.e. water tower discharges, road runoff) should be diverted to existing diversion ditches and basins (assuming basins are designed to handle the additional runoff amounts), or the offsite water should be treated as clean water and clean water bypass(es) should be submitted as a plan revision. 5. Ensure all perimeter measures are cleaned up, reinforced as needed, and functioning properly. It may be necessary to utilize j-hooks along perimeter silt fence and increase size of plunge pools at silt fence outlets. 6. Stabilize or provide ground cover on all disturbed areas (including stockpiles) that are not currently being worked to aid in minimizing erosion. 17 Continue clean up efforts and working toward addressing corrective actions in the current Notice of Violation which was issued on 11-21-22. Staff will be on site to perform a follow up inspection on the compliance date of 12-21-22. Please call or email with any questions or concerns. Thanks, <i mage001.j pg> Chad Waldrup Conservationist III CESSWI, CPESC Natural Resources Department Gaston SWCD 704.922.2153 1303 Dallas Cherryville Hwy. Dallas, NC 28034 www.gastongov.com This message may contain confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this email. Please notify the sender immediately by email if you have received this email by mistake and delete it from your system. Emails that do not contain confidential medical information are subject to North Carolina General Statute, Chapter 132 and may be considered a matter of public record. 18 , 2 . • A.. tr: :VC ."••• .74 % 4.'"V. • " • nt • iitk era./ .4jett r' . 7. • - _ •• • ` %." • +vq^ ,�a. r.,! : • fr •;:•,•(, ;•".. b•T ' • 7". • • 4. " .; • 4:: '..;• " Attl )' l 0 o100 Qo J • 0 M ,. IZ 0 I— J 0 ti Moy O9 GENERAL EROSION CONTROL CONSTRUCTION SEQUENCE THE FOLLOWING CONSTRUCTION SEQUENCE IS FURNISHED AS A GENERAL GUIDE FOR PREPARATION OF A SEQUENCE OF CONSTRUCTION EVENTS. ADDITIONS, DELETIONS, AND MODIFICATIONS SHOULD BE COORDINATED WITH THE ENGINEER AND GASTON COUNTY INSPECTOR. PHASE 1: PHASE 2: 1. OBTAIN GRADING/ EROSION CONTROL PLAN APPROVAL FROM THE TOWN OF STANLEY AND GASTON 11. COUNTY NATURAL RESOURCES DEPARTMENT. 2. THE CONTRACTOR SHALL SET UP AN ON -SITE PRE -CONSTRUCTION CONFERENCE WITH COUNTY EROSION CONTROL INSPECTOR TO DISCUSS EROSION CONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIOR TO ANY LAND DISTURBING ACTIVITY IS A VIOLATION AND IS SUBJECT TO 12. FINE. 3. INSTALL SWPPP SIGN AND TEMPORARY CONSTRUCTION ENTRANCE. 4. CONTRACTOR TO INSTALL CONSTRUCTION ENTRANCE, SILT FENCE WITH SILT FENCE CONCENTRATION OUTLETS, SKIMMER SEDIMENT BASINS AND SEDIMENT BASINS WITH INFILL AREAS AND TEMPORARY DIVERSION DITCHES WITH CHECK DAMS AS SHOWN ON PLANS, CLEARING AND GRUBBING ONLY AS NECESSARY TO INSTALL THESE DEVICES. (MASS GRUBBING NOT TO HAPPEN UNTIL AFTER EROSION CONTROL MEASURES ARE FULLY INSTALLED AND INSPECTED BY GASTON COUNTY INSPECTOR) BEGIN EARTHWORK/GRADING ACTIVITIES. MAINTAIN AND VERTICALLY ADJUST ALL INLET PROTECTION DEVICES, DITCHES, AND SILT FENCE THROUGHOUT GRADING ACTIVITIES TO MAINTAIN DRAINAGE PATTERNS. CONTRACTOR TO ENSURE ALL EROSION CONTROL MEASURES DO NOT ADVERSELY AFFECT CONSTRUCTABILITY OF PROJECT. CONTRACTOR TO ENSURE TEMPORARY DITCHES ARE STABILIZED AFTER VERTICALLY ADJUSTING AND ALL CHECK DAMS ARE MAINTAINED. 13. AS EARTHWORK ALLOWS, BEGIN INSTALLING STORM DRAINAGE STRUCTURES AND UTILITIES. AS STORM DRAINAGE IS INSTALLED, CONTRACTOR SHALL PLACE INLET PROTECTION ON ALL STORM STRUCTURES. NO PIPES SHALL BE LEFT EXPOSED AT THE CLOSE OF BUSINESS EACH DAY. 14. INSTALLATION OF SOUTH STANLEY CREEK CULVERT AND SEWER PIPE CROSSINGS SHALL BE AVOIDED UNTIL CONTRACTOR IS PREPARED TO INSTALL PERMANENT INFRASTRUCTURE. ALL WORK IN CREEKS AND WETLANDS SHALL BE IN ACCORDANCE WITH USACE AND NCDEQ PERMITS. 5. PRIOR TO DRAW INFILL NEXT TO SKIMMER SEDIMENT BASIN SB7, DOGHOUSE MANHOLES DH-MH#1 AND 15. DH-MH#2 ALONG WITH 240.00 LF OF TEMPORARY SEWER PIPE NEED TO BE INSTALLED TO REMOVE EXISTING SEWER ALIGNMENT FROM FUTURE PROPOSED RIGHT OF WAY. (SEE SHEET C2-4) INSTALL PROPOSED TEMPORARY FORCEMAIN REALIGNMENT TO PARALLEL TEMPORARY GRAVITY SEWER. EXISTING FOREMAIN AND GRAVITY SEWER PIPE AND STRUCTURES BEING BYPASSED BY TEMPORARY PIPE 16. ARE TO BE REMOVED PRIOR TO BACK FILL. 6. DURING BACK FILL PROCESS OF INFILL AREA NEXT TO SKIMMER SEDIMENT BASIN SB7 INSTALL TEMPORARY 240.00 LF OF 24" HDPE PIPE TO DISCHARGE NATURAL DRAW TO BASIN SB7. 7. ALL INFILL AREA SLOPES TO BE STABILIZED AS SHOWN ON PLANS AS SOON AS POSSIBLE BUT NO LATER THAN 7 DAYS. 8. WITH INFILL AREAS COMPLETE, THE REMAINING TEMPORARY DITCHES WITH CHECK DAMS CAN BE INSTALLED AS SHOWN ON PLANS TO DIRECT STORMWATER RUNOFF TO THE DETENTION BASINS. 9. SCHEDULE AN ON -SITE INSPECTION BY COUNTY INSPECTOR. WHEN APPROVED, INSPECTOR ISSUES THE GRADING PERMIT AND CLEARING AND GRUBBING OF REMAINDER OF SITE MAY BEGIN. co�cn —10. 0 C W W( CONTRACTOR INSTALLED ENHANCED SF OUTLET AND REPAIRED BUFFER CONTRACTOR INSTALLED ENHANCED SF OUTLET WITH STORAGE -1 r _ ^ TEMPORARY PIPE THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. Jt 200.0 LF 24" HDPE INV. UP: 772.00 INV. DOWN: 771.00 s, SLOPE: 0.50% CONTRACTOR TO VERIFY BERM ELEVATION AND CONSISTENCY \tic\ Ali NO CONSTRUCTION TRAFFIC SHALL ENTER , OR EXIT SITE UTILIZING RIDGE DRIVE UPON COMPLETION OF STORM SEWER SYSTEM CONVEYING STORMWATER TO SB-3 OR SB-4, SKIMMER SEDIMENT BASINS SB5, SB6, AND SB7 TO BE FILLED AND ALL TEMPORARY STRUCTURES AND APPURTENANCES TO BE REMOVED AFTER INSPECTOR APPROVAL. UPON THE COMPLETION OF OFFSITE SEWER AND PROPOSED PUMPSTATION AND FORCEMAIN ARE ACTIVE, ALL EXISTING SEWER LOCATED IN FUTURE PROPOSED RIGHT OR WAY OR UNDER PROPOSED PERMANENT STRUCTURES IS TO BE REMOVED. REMAINING EXISTING SEWER TO BE FILLED WITH FLOWABLE FILL AND ABANDONED IN PLACE. 17. DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES TO MINIMIZE EROSION. THE CONTRACTOR SHALL MAINTAIN CLOSE CONTACT WITH THE COUNTY INSPECTOR SO THAT PERIODIC INSPECTIONS CAN BE PERFORMED AT APPROPRIATE STAGES OF CONSTRUCTION. 18. GRADED SLOPES AND FILLS ARE TO BE PLANTED OR PROVIDED WITH PROTECTIVE COVER SUFFICIENT TO RESTRAIN EROSION WITHIN 7 CALENDAR DAYS AFTER THE COMPLETION OF ANY PHASE OF GRADING. ALL AREAS UPON WHICH NO FURTHER LAND DISTURBING ACTIVITY WILL BE UNDERTAKEN ARE TO BE PLANTED OR PROVIDED WITH PROTECTIVE COVER WITHIN 14 CALENDAR DAYS. 19. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S. DEPT. OF AGRICULTURE, GASTON COUNTY SOIL EROSION AND SEDIMENTATION CONTROL ORDINANCE, 20. AS AREAS ARE BROUGHT TO FINISHED GRADE, CONTRACTOR TO INSTALL FINAL GRASSING AND STABILIZE ALL SLOPES PER THE EROSION CONTROL NOTES AND DETAILS AND LANDSCAPE PLAN AND DETAILS. ji _ _ �� 21. CONTRACTOR SHALL COORDINATE WITH THE EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF f j� = ��\ �\_ EROSION CONTROL MEASURES. s,. �\\ t5 )l; / \=:_...,-:-.-\\>t \ FILL, STABILIZE AND FINALIZE SB-3 CONSTRUCTION DIVERT AS MUCH WATER TO SB-2 AS PRACTICAL e W CONTRACTOR HAND REMOVING SEDIMENT BEYOND THE SILT FENCE CONTRACTOR HAS i\ MATTED SLOPE OA \� 1 •- ENSURE DIVERSION IS INSTALLED INCLUDING CHECK DAMS T EROSION CONTROL LEGEND p N T T T 7 Z 600 — — —601— — — — — 600 601 DA# ±X.X AC J H:V X.X% 100.XX � °i 100.XX watztztgi PF 4' SF PF CF HZ PROPERTY LINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR DRAINAGE AREA DRAINAGE AREA LABEL SOIL TYPE DIRECTION OF OVERLAND FLOW DIRECTION OF OVERLAND FLOW RIP RAP APRON CONSTRUCTION EXIT EROSION CONTROL MATTING (NAG S75) LIMITS OF DISTURBANCE TEMPORARY JUTE NETTING BAFFLES (700 G/M2 COIR FABRIC OR HEAVIER) TEMPORARY DIVERSION DITCH OR BERM TEMP SILT FENCE WITH OUTLET TEMP TREE PROTECTION FENCE TEMP SILT / TREE PROTECTION FENCE TEMP CONSTRUCTION FENCE TEMPORARY HIGH HAZARD FENCE SILT SOCK / WATTLE CHECK DAM SEDIMENTATION CHAMBER BERM SLOPE DRAIN WITH RIP -RAP APRON TEMPORARY RISER SKIMMER SEDIMENT BASIN STONE FILTER RING HARDWARE CLOTH AND GRAVEL INLET PROTECTION CATCH BASIN INLET PROTECTION CONCRETE WASHOUT CONTRACTOR TO DIVERT WATER TOWER DISCHARGE AROUND DISTURBED AREA BGE NOTES: - 9/14/2022 OBSERVATIONS AND RECOMMENDATIONS - 12/2/2022 OBSERVATIONS AND RECOMMENDATIONS - CONTRACTOR INSTALLED ADDITIONAL EC MEASURES REVISED PER SEWER REVISED PER STANLEY 2ND ROUND COMMENTS REVISED PER STANLEY 1ST ROUND COMMENTS REVISED PER GASTON COUNTY COMMENTS DESCRIPTION 03/01 /2022 08/13/2021 06/09/2021 04/20/2021 DESIGNED BY: LK / AB DRAWN BY: REVIEWED BY: AG Lo LIJ tolit? n : o er LIJ 0 IN 00 cN rrj MERITAGE HOMES SUITE 300 CHARLOTTE / NC /28277 0 _1 Lij 03 cN CD c7[ o Lu o Lu Lu TOTAL DISTURBED AREA Know what's below. Call before you dig. 044291 FILE NUMBER: 6835-00 DATE: 03/19/2021