Loading...
HomeMy WebLinkAboutSW4220601_Design Calculations_20221221STORMWATER CALCULATIONS FOR HAVENBROOKE SUBDIVISION FORSYTH COUNTY, NORTH CAROLINA .. .�. . lm LATHAM-WALTERS ENGINEERING, INC. 16507-A NORTHCROSS DRIVE HUNTERSVILLE, N.C. 28078 Phone:704-895-8484 Fax:704-237-4362 N.C. Corporate License C-1815 FOR BRAXTON REAL ESTATE AND DEVELOPMENT CO. 6420 HAMPTON KNOLL RD. CLEMMONS, NC 27012 6/15/2022 RE�y/, j 1,�,/21 /22 10%CA �4 4�5 SEAL a 0 18584 2 611 Havenbrooke Subdivision Stormwater Narrative Havenbrooke Subdivision is a 71 lot single family development on a 74.97 acre parcel in Northeast Forsyth County. The subdivision is being developed as low density since the percent of impervious coverage is 10.34% which is well below the State's requirement of being less than 24% BUA, and the density is 0.947 units per acre which is far less than the maximum 2 units per acre allowed for low density. In trying to adhere to the low -density requirement of the State the subdivision is being developed with ditch section roads using 3:1 side slopes with a 2' bottom width with ditch liner and sodded with dense fescue. The pipe system for the development is limited to cross pipes with rip rap aprons on the downstream side to keep the outlet velocity at a non -erosive rate. To meet the State's low -density requirements per 15A NCAC 02H.1003 (2) the following design requirements were used for the low -density project and are listed and described below: (a) DENSTIY THRESHOLDS: The density for this project is less than 2 dwelling units per acre. The impervious percentage for the net 74.19 acre tract (74.97 ac. less surface water area) is 10.34% (7.67 acres impervious). (b) DISPERSED FLOWS: Stormwater flows for this project will be mostly conveyed using ditch section flows except where cross pipes are needed to convey stormwater across the NCDOT designed streets. The outflows from these culverts will use rip rap aprons to reduce velocities to be non -erosive. Calculations for all aprons have been provided in the calculation booklet. (c) VEGETATED CONVEYANCES: Vegetated conveyances have been designed with side slopes no steeper than 3:1 with a 2' bottom width to carry the runoff in roadside swales, curb outlets, and dispersed flows to aid in treating the runoff. Also at the end of all pipe outlets a vegetated conveyance has been designed to treat the runoff prior to outfalling into the natural buffer areas. Calculations for the conveyances are contained within. (d) CURB OUTLET SYSTEMS Even though curb and gutter are not being used within the development, outlet systems have been provided in suitable locations on all streets to convey stormwater to vegetated conveyance systems to provide additional treatment from roadside runoff. At the end of all curb outlets vegetated conveyances were designed using a 3:1 slope trapezoidal ditch with a minimum length of 100', a 2' bottom width, and slopes 5% or less. These ditches are to be and sodded with tall fescue. These areas are depicted on sheets C8.0 Et 8.1 with design information and details. 15A NCAC 2H.1003(4) VEGETATED SETBACKS: Buffers have been provided on all existing intermittent and perennial streams within the development. These have been denoted and shown on the plans. 15A NCAC 2H.1003(7) DEED RESTRICTIONS AND PROTECTIVE COVENANTS: The permittee shall record deed restrictions and protective covenants prior to the issuance of a certificate of occupancy to ensure that projects will be maintained in perpetuity consistent with the plans and specifications approved by the permitting authority. Dsche ule (25 YR. STORM) Page 1 Line Inlet Gnd/Rim Drng Total Runoff i i Flow Invert Invert Capac Line Line Line Vel Line Depth Depth Cover Line No. ID El Up Area Area Coeff Inlet Sys Rate Up Dn Full Size Length Slope Dn ID Dn Up Up No. (ft) (ac) (ac) (C) (in/hr) (in/hr) (cfs) (ft) (ft) (cfs) (in) (ft) (%) (ft/s) (ft) (ft) (ft) 1 DI-6A 880.44 0.18 5.08 0.50 8.25 5.96 14.12 876.52 876.00 24.54 24 51.850 1.00 8.07 6A-FES5A 1.09 1.35" 1.92 1 2 DI-7A 880.53 1.49 4.90 0.50 8.25 5.98 13.62 877.15 876.72 24.30 24 43.720 0.98 7.27 7A-6A 1.15 1.33" 1.38 2 3 DI-8A 883.00 3.41 3.41 0.45 6.03 6.03 9.25 878.94 877.65 11.39 18 128.760 1.00 7.18 8A-7A 1.03 1.17" 2.56 3 4 CULVERT F 879.60 0.64 0.64 0.50 8.25 8.25 2.64 877.60 877.00 9.09 18 93.994 0.64 4.45 F-END 0.55 0.62" 0.50 4 5 DI-1 D 879.54 0.52 2.83 0.50 8.25 8.22 11.62 874.70 874.00 18.62 18 26.140 2.68 11.09 1 D-FESD 0.86 1.30" 3.34 5 6 DI-2D 879.54 2.31 2.31 0.50 8.25 8.25 9.53 875.50 874.90 13.84 18 40.560 1.48 6.87 2D-1 D 1.10 1.19" 2.54 6 7 CULVERT E 878.63 0.94 0.94 0.50 8.25 8.25 3.88 876.42 874.20 13.62 18 131.880 1.68 6.60 HW2-FES1 E 0.55 0.75" 0.71 7 8 DI-3D 888.00 1.56 1.56 0.50 6.95 6.95 5.42 878.92 874.25 15.20 18 222.837 2.10 7.86 3D-FES4D 0.62 0.90" 7.58 8 9 SDMH-2B 867.01 0.00 4.03 0.50 0.00 6.82 12.86 854.80 854.00 15.46 18 43.340 1.85 9.78 2B-FES1 B 1.04 1.35" 10.71 9 10 DI-313 879.29 0.31 4.03 0.50 8.25 6.86 12.92 867.60 858.00 31.83 18 122.610 7.83 17.06 313-213 0.67 1.35" 10.19 10 11 DI-413 879.29 1.11 3.72 0.50 8.25 6.88 11.89 868.67 867.80 16.28 18 42.504 2.05 8.20 413-313 1.15 1.31" 9.12 11 12 SDMH 5B 881.99 0.00 2.61 0.45 0.00 6.92 8.13 870.29 868.90 14.83 18 81.817 1.70 5.98 513-413 1.08 1.10" 10.20 12 13 HW-613 874.85 2.61 2.61 0.45 6.95 6.95 8.16 871.00 870.49 13.00 18 39.064 1.31 7.33 HW6B-5B 0.90 1.11" 2.35 13 14 CULVERT C 875.06 2.06 2.06 0.50 8.25 8.25 8.49 871.91 871.11 22.98 24 77.480 1.03 3.34 HW5-FES4C 1.51 1.04" 1.15 14 15 DI-2C 867.28 3.05 3.48 0.50 8.25 8.15 14.18 861.60 858.00 21.86 18 97.496 3.69 13.16 2-FES1 C 0.88 1.39" 4.18 15 16 DI-3C 867.36 0.43 0.43 0.50 8.25 8.25 1.77 863.75 861.80 24.18 18 43.150 4.52 1.18 3C-2C 1.19 0.50" 2.11 16 17 D I-2A 863.93 0.34 8.02 0.50 8.25 6.01 24.09 849.54 847.91 36.74 24 72.490 2.25 12.47 2A-F E S 1 A 1.18 1.74" 12.39 17 18 D I-3A 863.93 0.36 7.68 0.50 8.25 6.02 23.11 857.04 856.34 32.16 24 40.630 1.72 11.14 3A-2A 1.25 1.71 " 4.89 18 19 DI-4A 868.00 7.32 7.32 0.50 6.03 6.03 22.05 859.00 858.00 42.11 24 33.859 2.95 13.55 4A-3A 1.03 1.68" 7.00 19 Project File: 2134 STORM REV11-22 DITCH.stm Number of lines: 19 Date: 12/21/2022 NOTES: Intensity = 102.61 / (Inlet time + 16.50) ^ 0.82 -- Return period = 25 Yrs. ; " Critical depth Storm Sewers Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 1 2. Determine Runoff for 10-Year Storm Q = CIA 26.4 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 9954 cf 4. Size Basin: INPUT Basin No. Drainage Area Disturbed Area C Time of Concentratior Intensity Weir Depth Weir Length Surface Area = (Q10 x325) = 8595.23 S.F. 8818.00 S.F. @ EL. Length = 2 x Width Width 65.6 Feet USE W = 60 Length 131.1 Feet USE L = 120 Depth 1.16 Feet USE D = 1.5 Actual Volume = 16149.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 1.0 FEET Depth to Top of Embankment 6.0 FEET 2:1 Side Slopes 5' Top Width 1 8.14 5.53 0.45 5 7.22 1.0 10 848 TOP WEIR BOTTOM 850 848 846 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 26.4 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 2.00 " Diameter Skimmer Orifice Size= 2.00 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.16667 ft Qo= 0.04286 cfs 3703.39 cf/day Volume: 9954 cf Drawdown time= 64.51 Hrs 2.687808 (48-120 hours Required) Drawdown per 0.02 feet Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 2 2. Determine Runoff for 10-Year Storm Q = CIA 14.8 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 7902 cf 4. Size Basin: Surface Area = (Q10 x325) = 4825.58 S.F. Length = 2 x Width Width 49.1 Feet USE W = Length 98.2 Feet USE L = Depth 1.64 Feet USE D = INPUT Basin No. 2 Drainage Area 4.57 Disturbed Area 4.39 C 0.45 Time of Concentratior 5 Intensity 7.22 Weir Depth 1.0 Weir Length 10 6980.00 S.F. @ EL. 850 60 TOP 852 120 WEIR 850 1.5 BOTTOM 848.5 Actual Volume = 9743.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 1.0 FEET Depth to Top of Embankment 6.0 FEET 2:1 Side Slopes 5' Top Width 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 14.8 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 2.00 " Diameter Skimmer Orifice Size= 1.75 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.16667 ft Qo= 0.03282 cfs 2835.41 cf/day Volume: 7902 cf Drawdown time= 66.89 Hrs 2.7869 (48-120 hours Required) Drawdown per 0.01 feet Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 3 2. Determine Runoff for 10-Year Storm Q = CIA 20.1 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 6858 cf 4. Size Basin: Surface Area = (Q10 x325) = 6536.18 S.F. Length = 2 x Width Width 57.2 Feet USE W = Length 114.3 Feet USE L = Depth 1.05 Feet USE D = INPUT Basin No. 3 Drainage Area 6.19 Disturbed Area 3.81 C 0.45 Time of Concentratior 5 Intensity 7.22 Weir Depth 1.0 Weir Length 10 6605.00 S.F. @ EL. 876 50 TOP 878 120 WEIR 876 1.5 BOTTOM 874.5 Actual Volume = 9142.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 2.0 FEET Depth to Top of Embankment 4.0 FEET 2:1 Side Slopes 5' Top Width 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 20.1 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 2.00 " Diameter Skimmer Orifice Size= 1.75 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.16667 ft Qo= 0.03282 cfs 2835.41 cf/day Volume: 6858 cf Drawdown time= 58.05 Hrs 2.4187 (48-120 hours Required) Drawdown per 0.03 feet Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 4 2. Determine Runoff for 10-Year Storm Q = CIA 11.3 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 6282 cf 4. Size Basin: Surface Area = (Q10 x325) = 3685.18 S.F. Length = 2 x Width Width 42.9 Feet USE W = Length 85.9 Feet USE L = Depth 1.70 Feet USE D = INPUT Basin No. 4 Drainage Area 3.49 Disturbed Area 3.49 C 0.45 Time of Concentratior 5 Intensity 7.22 Weir Depth 2.0 Weir Length 10 3710.00 S.F. @ EL. 850 50 TOP 852 120 WEIR 850 1.5 BOTTOM 848 Actual Volume = 6512.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 2.0 FEET Depth to Top of Embankment 4.0 FEET 2:1 Side Slopes 5' Top Width 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 11.3 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 2.00 " Diameter Skimmer Orifice Size= 1.75 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.16667 ft Qo= 0.03282 cfs 2835.41 cf/day Volume: 6282 cf Drawdown time= 53.17 Hrs 2.215554 (48-120 hours Required) Drawdown per 0.04 feet Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 5 2. Determine Runoff for 10-Year Storm Q = CIA 13.7 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 3042 cf 4. Size Basin: Surface Area = (Q10 x325) = 4445.44 S.F. Length = 2 x Width Width 47.1 Feet USE W = Length 94.3 Feet USE L = Depth 0.68 Feet USE D = INPUT Basin No. 5 Drainage Area 4.21 Disturbed Area 1.69 C 0.45 Time of Concentratior 5 Intensity 7.22 Weir Depth 2.0 Weir Length 10 4780.00 S.F. @ EL. 850 50 TOP 830 100 WEIR 828 1.0 BOTTOM 827 Actual Volume = 4514.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 2.0 FEET Depth to Top of Embankment 4.0 FEET 2:1 Side Slopes 5' Top Width 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 13.7 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 1.50 " Diameter Skimmer Orifice Size= 1.25 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.125 ft Qo= 0.01450 cfs 1252.82 cf/day Volume: 3042 cf Drawdown time= 58.27 Hrs 2.428114 (48-120 hours Required) Drawdown per 0.03 feet Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 6 2. Determine Runoff for 10-Year Storm Q = CIA 17.1 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 5976 cf 4. Size Basin: Surface Area = (Q10 x325) = 5564.72 S.F. Length = 2 x Width Width 52.7 Feet USE W = Length 105.5 Feet USE L = Depth 1.07 Feet USE D = INPUT Basin No. 6 Drainage Area 5.27 Disturbed Area 3.32 C 0.45 Time of Concentratior 5 Intensity 7.22 Weir Depth 2.0 Weir Length 10 5456.00 S.F. @ EL. 856 55 TOP 858 110 WEIR 856 1.0 BOTTOM 854 Actual Volume = 9847.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 2.0 FEET Depth to Top of Embankment 4.0 FEET 2:1 Side Slopes 5' Top Width 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 17.1 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 2.00 " Diameter Skimmer Orifice Size= 1.60 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.16667 ft Qo= 0.02743 cfs 2370.17 cf/day Volume: 5976 cf Drawdown time= 60.51 Hrs 2.521339 (48-120 hours Required) Drawdown per 0.03 feet Havenbrooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 7 2. Determine Runoff for 10-Year Storm Q = CIA 6.4 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 3546 cf 4. Size Basin: Surface Area = (Q10 x325) = 2080.17 S.F. Length = 2 x Width Width 32.3 Feet USE W = Length 64.5 Feet USE L = Depth 1.70 Feet USE D = INPUT Basin No. 7 Drainage Area 1.97 Disturbed Area 1.97 C 0.45 Time of Concentratior 5 Intensity 7.22 Weir Depth 2.0 Weir Length 10 2050.00 S.F. @ EL. 850 32 TOP 852 64 WEIR 850 2.0 BOTTOM 848 Actual Volume = 3454.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 2.0 FEET Depth to Top of Embankment 4.0 FEET 2:1 Side Slopes 5' Top Width 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 6.4 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 1.50 " Diameter Skimmer Orifice Size= 1.25 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.125 ft Qo= 0.01450 cfs 1252.82 cf/day Volume: 3546 cf Drawdown time= 67.93 Hrs 2.830405 (48-120 hours Required) Drawdown per 0.03 feet II��������II�II�� � tl���� TR 55 Urban Hydrology for Small Watershed. LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Havenbrooke Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Post -developed Tc for Existing Drainage Area-Basin#1 Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nQA0.8))/((P2)^0.5 x s^0.4) 0.3 n Manning's Coefficient for Grass 100 L Flow Length Travel (100' max. urban, 300' max rural) 3.52 P2 2 Year - 24 Hour Rainfall for Midland, NC 3.00% s Slope of hydraulic grade line 0.231 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345*s^0.5) Unpaved V2 = (20.3282*s^0.5) Paved 0.01 Length of Paved Flow 296 Length of Unpaved Flow 6.67% Slope of Paved Flow 6.67% Slope of Unpaved Flow 4.166 V2 -Unpaved (fps) 5.249 V2 - Paved (fps) 0.002 T2 Paved (seconds) 71.053 T2 Unpaved (seconds) 0.020 T2 Total (hours) 5. Open Channel Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 5 a - area of foot depth ditch with 3:1 side slopes. ft^2 0.625 r - hydraulic radius, f; Area/Wetted Perimeter 0.04 s - slope of hydraulic grade line, (ft/ft) 0.035 n -Manning's roughness coefficient h1 h2 I h1 h2 I h1 h2 I 6.298 V - velocity in fps 415 Length of Flow (ft.) 0.018 T3 (hrs.) Length/Velocity/3600 0.269 Tc = T1 + T2 + T3 (hrs.) 16.11 Total Tc (minutes) Post Developed Tc = 16.11 minutes Use 15 minutes TR 55 Urban Hydrology for Small Watershed. LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Havenbrooke Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Post -developed Tc for Existing Drainage Area -Basin 6 Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nQA0.8))/((P2)^0.5 x s^0.4) h1 0.3 n Manning's Coefficient for Grass h2 100 L Flow Length Travel (100' max. urban, 300' max rural) 1 3.52 P2 2 Year - 24 Hour Rainfall for Midland, NC 14.00% s Slope of hydraulic grade line 0.124 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345*s^0.5) Unpaved V2 = (20.3282*s^0.5) Paved 0.01 Length of Paved Flow 296 Length of Unpaved Flow 15.49% Slope of Paved Flow 15.49% Slope of Unpaved Flow 6.351 V2 -Unpaved (fps) 8.001 V2 - Paved (fps) 0.001 T2 Paved (seconds) 46.609 T2 Unpaved (seconds) 0.013 T2 Total (hours) 5. Open Channel Flow h1 h2 I V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) h1 h2 5 a - area of foot depth ditch with 3:1 side slopes. ft^2 I 0.625 r - hydraulic radius, f; Area/Wetted Perimeter 10.00 s - slope of hydraulic grade line, (ft/ft) 0.035 n -Manning's roughness coefficient 98.408 V - velocity in fps 1 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 0.137 Tc = T1 + T2 + T3 (hrs.) 8.25 Total Tc (minutes) Post Developed Tc = 8.25 minutes Use 10 minutes TR 55 Urban Hydrology for Small Watershed. LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Havenbrooke Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Post -developed Tc for Existing Drainage Area-VCD 3 and HW-5B Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nQA0.8))/((P2)^0.5 x s^0.4) h1 0.3 n Manning's Coefficient for Grass h2 100 L Flow Length Travel (100' max. urban, 300' max rural) 1 3.52 P2 2 Year - 24 Hour Rainfall for Midland, NC 14.00% s Slope of hydraulic grade line 0.124 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345*s^0.5) Unpaved V2 = (20.3282*s^0.5) Paved 0.01 Length of Paved Flow 296 Length of Unpaved Flow 15.49% Slope of Paved Flow 15.49% Slope of Unpaved Flow 6.351 V2 -Unpaved (fps) 8.001 V2 - Paved (fps) 0.001 T2 Paved (seconds) 46.609 T2 Unpaved (seconds) 0.013 T2 Total (hours) 5. Open Channel Flow h1 h2 I V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) h1 h2 5 a - area of foot depth ditch with 3:1 side slopes. ft^2 I 0.625 r - hydraulic radius, f; Area/Wetted Perimeter 10.00 s - slope of hydraulic grade line, (ft/ft) 0.035 n -Manning's roughness coefficient 98.408 V - velocity in fps 1 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 0.137 Tc = T1 + T2 + T3 (hrs.) 8.25 Total Tc (minutes) Post Developed Tc = 8.25 minutes Use 10 minutes TR 55 Urban Hydrology for Small Watershed. LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Havenbrooke Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Post -developed Tc for Existing Drainage Area-VCD10 and DI-8A Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nQA0.8))/((P2)^0.5 x s^0.4) 0.3 n Manning's Coefficient for Grass 100 L Flow Length Travel (100' max. urban, 300' max rural) 3.52 P2 2 Year - 24 Hour Rainfall for Midland, NC 3.00% s Slope of hydraulic grade line 0.231 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345*s^0.5) Unpaved V2 = (20.3282*s^0.5) Paved 0.01 Length of Paved Flow 296 Length of Unpaved Flow 6.67% Slope of Paved Flow 6.67% Slope of Unpaved Flow 4.166 V2 -Unpaved (fps) 5.249 V2 - Paved (fps) 0.002 T2 Paved (seconds) 71.053 T2 Unpaved (seconds) 0.020 T2 Total (hours) 5. Open Channel Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 5 a - area of foot depth ditch with 3:1 side slopes. ft^2 0.625 r - hydraulic radius, f; Area/Wetted Perimeter 0.04 s - slope of hydraulic grade line, (ft/ft) 0.035 n -Manning's roughness coefficient h1 h2 I h1 h2 I h1 h2 I 6.298 V - velocity in fps 415 Length of Flow (ft.) 0.018 T3 (hrs.) Length/Velocity/3600 0.269 Tc = T1 + T2 + T3 (hrs.) 16.11 Total Tc (minutes) Post Developed Tc = 16.11 minutes Use 15 minutes Havenbrooke Subdivision INLET CAPACITY CALCULATION Date: 12/12/2022 Project #: 2021.34 CAPACITY CHECK FOR NCDOT DROP INLETS CAPACITY CHECK FOR NCDOT STD. 840.05 OPEN THROAT INLET OPENING HEIGHT 0.5 FT. NUMBER OF OPENINGS 4 WIDTH OPENING 4.33 FT. AREA OF OPENING = 8.66 SF TOTAL LENGTH = 17.32 FT WEIR EQUATION: Q= CLH^3/2 (C=3.1) ORIFICE EQUATION: Q= CA(2GH)^1/2 (C=0.60) DEPTH Q weir Q orifice (FEET) 0.56 22.50 cfs 31.20 1 53.69 41.70 1.5 98.64 51.07 MAX. FLOW TO A STD INLET IS FOR DI-4A Q25=22.05 CFS HW/d for max flow of 22.05 cfs = 0.56' Culvert Report Hydraflow Express Extension for AUtodeskS AUtoCADO Civil 3DO by Autodesk, Inc. CULVERT C Invert Elev Dn (ft) = 871.11 Calculations Pipe Length (ft) = 77.48 Qmin (cfs) Slope (%) = 1.03 Qmax (cfs) Invert Elev Up (ft) = 871.91 Tailwater Elev (ft) Rise (in) = 24.0 Shape = Circular Highlighted Span (in) = 24.0 Qtotal (cfs) No. Barrels = 1 Qpipe (cfs) n-Value = 0.012 Qovertop (cfs) Culvert Type = Circular Concrete Veloc Dn (ft/s) Culvert Entrance = Square edge w/headwall (C) Veloc Up (ft/s) Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 HGL Dn (ft) HGL Up (ft) Embankment Hw Elev (ft) Top Elevation (ft) = 874.00 Hw/D (ft) Top Width (ft) = 54.00 Flow Regime Crest Width (ft) = 54.00 Elev (R) 875 00 674.00 B73.00 872.00 871.00 B70.00 0 CULVERT C 10 20 30 40 50 60 70 80 90 100 110 Circular Culvert HGL Embank Wednesday, Dec 21 2022 = 8.49 = 8.49 = (dc+D)/2 = 8.49 = 8.49 = 0.00 = 3.32 = 5.16 = 872.63 = 872.95 = 873.42 = 0.76 = Inlet Control Hw Depth (fl) 120 Reach (ft) Culvert Report Hydraflow Express Extension for AUtodeskS AUtoCADO Civil 3DO by Autodesk, Inc. CULVERT E Invert Elev Dn (ft) = 874.20 Calculations Pipe Length (ft) = 131.88 Qmin (cfs) Slope (%) = 1.68 Qmax (cfs) Invert Elev Up (ft) = 876.42 Tailwater Elev (ft) Rise (in) = 18.0 Shape = Circular Highlighted Span (in) = 18.0 Qtotal (cfs) No. Barrels = 1 Qpipe (cfs) n-Value = 0.012 Qovertop (cfs) Culvert Type = Circular Concrete Veloc Dn (ft/s) Culvert Entrance = Square edge w/headwall (C) Veloc Up (ft/s) Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 HGL Dn (ft) HGL Up (ft) Embankment Hw Elev (ft) Top Elevation (ft) = 878.00 Hw/D (ft) Top Width (ft) = 92.00 Flow Regime Crest Width (ft) = 24.00 Elev (R] 879 00 BIB.00 M-00 976.00 975.00 874.00 CULVERT E Wednesday, Dec 21 2022 = 3.88 = 3.88 = (dc+D)/2 = 3.88 = 3.88 = 0.00 = 2.73 = 4.37 = 875.33 = 877.17 = 877.50 = 0.72 = Inlet Control Hw Depth (ft) 2 58 1.58 0.59 -0.42 -1.42 -2.42 B73.00 i i i i i i i i i i i i i i i i i i i -3.42 0 10 20 30 40 50 60 70 80 K 100 110 120 130 140 150 160 170 180 Circular Culvert HGL Embank Reach (ft) Culvert Report Hydraflow Express Extension for AUtodeskS AUtoCADO Civil 3DO by Autodesk, Inc. CULVERT F Invert Elev Dn (ft) = 877.00 Calculations Pipe Length (ft) = 93.99 Qmin (cfs) Slope (%) = 0.64 Qmax (cfs) Invert Elev Up (ft) = 877.60 Tailwater Elev (ft) Rise (in) = 18.0 Shape = Circular Highlighted Span (in) = 18.0 Qtotal (cfs) No. Barrels = 1 Qpipe (cfs) n-Value = 0.012 Qovertop (cfs) Culvert Type = Circular Concrete Veloc Dn (ft/s) Culvert Entrance = Square edge w/headwall (C) Veloc Up (ft/s) Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 HGL Dn (ft) HGL Up (ft) Embankment Hw Elev (ft) Top Elevation (ft) = 880.00 Hw/D (ft) Top Width (ft) = 34.00 Flow Regime Crest Width (ft) = 34.00 Elev (R) 881 00 880.00 879 00 818.00 977.00 876.00 0 10 20 30 Circular Culvert 40 50 — HGL CULVERT F Wednesday, Dec 21 2022 = 2.64 = 2.64 = (dc+D)/2 = 2.64 = 2.64 = 0.00 = 1.98 = 3.87 = 878.06 = 878.22 = 878.46 = 0.58 = Inlet Control Hw Depth (ft) 3 40 2.40 1 40 0.40 -0 60 -1.60 60 70 80 90 100 110 120 130 140 — Embank Reach (ft) VEGETATED CONVEYANCE DITCH CALCULATIONS 10 YR. STORM Channel ID Bottom Width FT. Drain Area AC. Imperv. Area Runoff Coeff © i10 in/hr Q10 CFS Mannings (Ditch) Slope ft/ft Ditch Length FT. Normal Depth FT. Velocity FPS Ditch Liner and Permanent Vegetation Type VCD 1 2 0.35 0.16 0.5 6.84 1.20 0.067 0.03 100 0.3 1.41 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 2 2 0.191 0.05 0.51 6.84 0.651 0.051 0.0276 1051 0.23 1.051 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 3 2 5.02 0.85 0.5 5.47 13.73 0.075 0.0426 125 0.97 2.88 N.A.G. SC 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 4 2 0.61 0.1 0.5 6.84 2.09 0.097 0.0427 143 0.44 1.44 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 5 2 0.371 0.11 0.51 6.84 1.27 0.102 0.0464 135 0.34 1.241 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 6 2 1.42 0.07 0.5 6.84 4.86 0.084 0.046 250 0.61 2.06 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 7 2 5.84 0 0.5 5.47 15.97 0.042 0.0418 353 0.8 4.53 N.A.G. SC 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 8 2 2.7 1.12 0.5 5.47 7.38 0.047 0.0421 180 0.58 3.42 N.A.G. SC 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 9 2 3.57 1.07 0.5 5.47 9.76 0.044 0.05 148 0.56 3.9 N.A.G. SC 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 10 2 7.84 1.46 0.45 5.19 18.31 0.068 0.05 150 1.06 3.6 N.A.G. C 125 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 11 2 0.93 0.24 0.51 6.84 3.18 0.063 0.022 180 0.52 1.73 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 12 2 3.41 0.19 0.5 5.19 8.85 0.047 0.038 425 0.65 3.46 N.A.G. SC 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 13 2 0.36 0.06 0.5 6.84 1.23 0.077 0.0177 130 0.37 1.07 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 14 2 1.56 0 0.5 5.19 4.05 0.051 0.0419 395 0.45 2.72 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 15 2 2.82 1.04 0.5 5.19 7.32 0.045 0.0476 165 0.55 3.66 N.A.G. SC 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 16 2 1.68 0.65 0.5 6.84 5.75 0.057 0.0234 132 0.65 2.24 N.A.G. S 150 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) VCD 17 2 4.36 0.39 0.45 6.84 13.42 0.072 0.051 2351 0.91 3.13 N.A.G. C 125 STAPLE PATTERN "D" W/ MIX (SOD & BUNCH GRASS) 11/16/22, 3:50 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>> VCD 1 Name VCD 1 Discharge 1.2 Channel Slope 0.03 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 1.2 cfs 1.8 ft/s 0.24 ft 0.047 1.8 Ibs/ft2 0.46 Ibs/ft2 3.94 STABLE D Unvegetated Underlying Straight 1.2 cfs 1.8 ft/s 0.24 ft 0.047 1.96 Ibs/ft2 0.35 Ibs/ft2 5.57 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight Vegetation Underlying Straight Substrate 1.2 cfs 1.41 ft/s 0.3 ft 0.067 1.2 cfs 1.41 ft/s 0.3 ft 0.067 4lbs/ft2 0.55lbs/ft2 7.23 STABLE 4lbs/ft2 0.41lbs/ft2 9.69 STABLE hftps://ecmds.com/project/154418/channel-analysis/234646/show# 1 /1 11/16/22, 3:51 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD2 Name VCD 2 Discharge 0.65 Channel Slope 0.0276 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 0.65 cfs 1.36 ft/s 0.19 ft 0.051 1.8 Ibs/ft2 0.32 Ibs/ft2 5.6 STABLE D Unvegetated Underlying Straight 0.65 cfs 1.36 ft/s 0.19 ft 0.051 1.96 Ibs/ft2 0.26 Ibs/ft2 7.58 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 0.65 cfs 1.05 ft/s 0.23 ft 0.075 4 Ibs/ft2 0.4 Ibs/ft2 10.09 STABLE Vegetation Underlying Straight 0.65 cfs 1.05 ft/s 0.23 ft 0.075 4 Ibs/ft2 0.31 Ibs/ft2 12.96 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234653/show 1 /1 11/16/22, 4:08 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD3 Name VCD 3 Discharge 13.73 Channel Slope 0.0426 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class B 12-24 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC150 Straight 13.73 cfs 5.16 ft/s 0.66 ft 0.034 2 Ibs/ft2 1.77 Ibs/ft2 1.13 STABLE D Unvegetated Underlying Straight 13.73 cfs 5.16 ft/s 0.66 ft 0.034 2.18 Ibs/ft2 1.14 Ibs/ft2 1.92 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 13.73 cfs 2.88 ft/s 0.97 ft 0.075 4 Ibs/ft2 2.58 Ibs/ft2 1.55 STABLE Vegetation Underlying Straight 13.73 cfs 2.88 ft/s 0.97 ft 0.075 4 Ibs/ft2 1.56 Ibs/ft2 2.57 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234654/show 1 /1 11/16/22, 4:11 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD4 Name VCD 4 Discharge 2.09 Channel Slope 0.0427 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class B 12-24 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 2.09 cfs 2.63 ft/s 0.28 ft 0.041 1.8 Ibs/ft2 0.74 Ibs/ft2 2.42 STABLE D Unvegetated Underlying Straight 2.09 cfs 2.63 ft/s 0.28 ft 0.041 1.96 Ibs/ft2 0.56 Ibs/ft2 3.5 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 2.09 cfs 1.44 ft/s 0.44 ft 0.097 4 Ibs/ft2 1.17 Ibs/ft2 3.42 STABLE Vegetation Underlying Straight 2.09 cfs 1.44 ft/s 0.44 ft 0.097 4 Ibs/ft2 0.81 Ibs/ft2 4.93 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234656/show 1 /1 11/16/22, 4:12 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD5 Name VCD 5 Discharge 1.27 Channel Slope 0.0464 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class B 12-24 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 1.27 cfs 2.26 ft/s 0.21 ft 0.043 1.8 Ibs/ft2 0.62 Ibs/ft2 2.93 STABLE D Unvegetated Underlying Straight 1.27 cfs 2.26 ft/s 0.21 ft 0.043 1.96 Ibs/ft2 0.49 Ibs/ft2 4.04 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 1.27 cfs 1.24 ft/s 0.34 ft 0.102 4 Ibs/ft2 0.98 Ibs/ft2 4.07 STABLE Vegetation Underlying Straight 1.27 cfs 1.24 ft/s 0.34 ft 0.102 4 Ibs/ft2 0.72 Ibs/ft2 5.59 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234658/show 1 /1 11/16/22, 4:14 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD6 Name VCD 6 Discharge 4.86 Channel Slope 0.046 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class B 12-24 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 4.86 cfs 3.73 ft/s 0.4 ft 0.037 1.8 Ibs/ft2 1.16 Ibs/ft2 1.55 STABLE D Unvegetated Underlying Straight 4.86 cfs 3.73 ft/s 0.4 ft 0.037 1.96 Ibs/ft2 0.82 Ibs/ft2 2.39 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 4.86 cfs 2.06 ft/s 0.61 ft 0.084 4 Ibs/ft2 1.76 Ibs/ft2 2.27 STABLE Vegetation Underlying Straight 4.86 cfs 2.06 ft/s 0.61 ft 0.084 4 Ibs/ft2 1.15 Ibs/ft2 3.48 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234659/show 1 /1 11/16/22, 4:18 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD7 Name VCD 7 Discharge 15.97 Channel Slope 0.0418 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC150 Straight 15.97 cfs 5.38 ft/s 0.71 ft 0.033 2 Ibs/ft2 1.86 Ibs/ft2 1.07 STABLE D Unvegetated Underlying Straight 15.97 cfs 5.38 ft/s 0.71 ft 0.033 2.18 Ibs/ft2 1.19 Ibs/ft2 1.84 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 15.97 cfs 4.53 ft/s 0.8 ft 0.042 4 Ibs/ft2 2.09 Ibs/ft2 1.91 STABLE Vegetation Underlying Straight 15.97 cfs 4.53 ft/s 0.8 ft 0.042 3.33 Ibs/ft2 1.3 Ibs/ft2 2.56 STABLE Substrate hftps://ecmds.com/project/l54418/channel-analysis/234661 /show 1 /1 11/16/22, 4:19 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD8 Name VCD 8 Discharge 7.38 Channel Slope 0.0421 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC150 Straight 7.38 cfs 4.14 ft/s 0.51 ft 0.036 2 Ibs/ft2 1.33 Ibs/ft2 1.5 STABLE D Unvegetated Underlying Straight 7.38 cfs 4.14 ft/s 0.51 ft 0.036 2.18 Ibs/ft2 0.9 Ibs/ft2 2.42 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 7.38 cfs 3.42 ft/s 0.58 ft 0.047 4 Ibs/ft2 1.52 Ibs/ft2 2.64 STABLE Vegetation Underlying Straight 7.38 cfs 3.42 ft/s 0.58 ft 0.047 4 Ibs/ft2 1 Ibs/ft2 4 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234662/show 1 /1 11/16/22, 4:22 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD9 Name VCD 9 Discharge 8.15 Channel Slope 0.05 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Underlying Straight 8.15 cfs 4.68 ft/s 0.5 ft 0.034 2.18 Ibs/ft2 1.05 Ibs/ft2 2.07 STABLE D Substrate SC150 Straight 8.15 cfs 4.68 ft/s 0.5 ft 0.034 2 Ibs/ft2 1.55 Ibs/ft2 1.29 STABLE D Unvegetated Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 8.15 cfs 3.9 ft/s 0.56 ft 0.044 4 Ibs/ft2 1.75 Ibs/ft2 2.28 STABLE Vegetation Underlying Straight 8.15 cfs 3.9 ft/s 0.56 ft 0.044 3.65 Ibs/ft2 1.16 Ibs/ft2 3.14 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234664/show 1 /1 11/16/22, 4:25 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>> VCD 10 Name VCD 10 Discharge 19.73 Channel Slope 0.05 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class B 12-24 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) C125 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern C125 Straight 19.73 cfs 6.42 ft/s 0.73 ft 0.031 2.3 Ibs/ft2 2.28 Ibs/ft2 1.01 STABLE D Unvegetated Underlying Straight 19.73 cfs 6.42 ft/s 0.73 ft 0.031 2.51 Ibs/ft2 1.44 Ibs/ft2 1.73 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 19.73 cfs 3.6 ft/s 1.06 ft 0.068 4 Ibs/ft2 3.3 Ibs/ft2 1.21 STABLE Vegetation Underlying Straight 19.73 cfs 3.6 ft/s 1.06 ft 0.068 4 Ibs/ft2 1.97 Ibs/ft2 2.03 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234665/show 1 /1 11/16/22, 4:27 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>> VCD 11 Name VCD 11 Discharge 3.18 Channel Slope 0.022 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 3.18 cfs 2.21 ft/s 0.43 ft 0.045 1.8 Ibs/ft2 0.6 Ibs/ft2 3.02 STABLE D Unvegetated Underlying Straight 3.18 cfs 2.21 ft/s 0.43 ft 0.045 1.96 Ibs/ft2 0.42 Ibs/ft2 4.72 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 3.18 cfs 1.73 ft/s 0.52 ft 0.063 4 Ibs/ft2 0.71 Ibs/ft2 5.64 STABLE Vegetation Underlying Straight 3.18 cfs 1.73 ft/s 0.52 ft 0.063 4 Ibs/ft2 0.48 Ibs/ft2 8.37 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234666/show 1 /1 11/16/22, 4:29 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >> > VCD 12 Name VCD 12 Discharge 8.85 Channel Slope 0.038 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC150 Straight 8.85 cfs 4.18 ft/s 0.57 ft 0.036 2 Ibs/ft2 1.35 Ibs/ft2 1.48 STABLE D Unvegetated Underlying Straight 8.85 cfs 4.18 ft/s 0.57 ft 0.036 2.18 Ibs/ft2 0.89 Ibs/ft2 2.44 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 8.85 cfs 3.46 ft/s 0.65 ft 0.047 4 Ibs/ft2 1.54 Ibs/ft2 2.6 STABLE Vegetation Underlying Straight 8.85 cfs 3.46 ft/s 0.65 ft 0.047 4 Ibs/ft2 0.99 Ibs/ft2 4.02 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234667/show 1 /1 11/16/22, 4:31 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >> > VCD 13 Name VCD 13 Discharge 1.23 Channel Slope 0.0177 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 1.23 cfs 1.4 ft/s 0.3 ft 0.052 1.8 Ibs/ft2 0.33 Ibs/ft2 5.4 STABLE D Unvegetated Underlying Straight 1.23 cfs 1.4 ft/s 0.3 ft 0.052 1.96 Ibs/ft2 0.25 Ibs/ft2 7.92 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 1.23 cfs 1.07 ft/s 0.37 ft 0.077 4 Ibs/ft2 0.41 Ibs/ft2 9.77 STABLE Vegetation Underlying Straight 1.23 cfs 1.07 ft/s 0.37 ft 0.077 4 Ibs/ft2 0.29 Ibs/ft2 13.64 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234669/show 1 /1 11/16/22, 4:32 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >> > VCD 14 Name VCD 14 Discharge 4.05 Channel Slope 0.0419 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 4.05 cfs 3.33 ft/s 0.38 ft 0.038 1.8 Ibs/ft2 1.01 Ibs/ft2 1.79 STABLE D Unvegetated Underlying Straight 4.05 cfs 3.33 ft/s 0.38 ft 0.038 1.96 Ibs/ft2 0.72 Ibs/ft2 2.74 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 4.05 cfs 2.72 ft/s 0.45 ft 0.051 4 Ibs/ft2 1.16 Ibs/ft2 3.43 STABLE Vegetation Underlying Straight 4.05 cfs 2.72 ft/s 0.45 ft 0.051 4 Ibs/ft2 0.81 Ibs/ft2 4.96 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234672/show 1 /1 11/16/22, 4:34 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >> > VCD 15 Name VCD 15 Discharge 7.32 Channel Slope 0.0476 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC150 Straight 7.32 cfs 4.39 ft/s 0.48 ft 0.035 2 Ibs/ft2 1.44 Ibs/ft2 1.39 STABLE D Unvegetated Underlying Straight 7.32 cfs 4.39 ft/s 0.48 ft 0.035 2.18 Ibs/ft2 0.98 Ibs/ft2 2.23 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 7.32 cfs 3.66 ft/s 0.55 ft 0.045 4 Ibs/ft2 1.63 Ibs/ft2 2.45 STABLE Vegetation Underlying Straight 7.32 cfs 3.66 ft/s 0.55 ft 0.045 3.85 Ibs/ft2 1.09 Ibs/ft2 3.55 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234674/show 1 /1 11/16/22, 4:35 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >> > VCD 16 Name VCD 16 Discharge 5.75 Channel Slope 0.0234 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 5.75 cfs 2.81 ft/s 0.56 ft 0.042 1.8 Ibs/ft2 0.81 Ibs/ft2 2.22 STABLE D Unvegetated Underlying Straight 5.75 cfs 2.81 ft/s 0.56 ft 0.042 1.96 Ibs/ft2 0.54 Ibs/ft2 3.63 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 5.75 cfs 2.24 ft/s 0.65 ft 0.057 4 Ibs/ft2 0.95 Ibs/ft2 4.21 STABLE Vegetation Underlying Straight 5.75 cfs 2.24 ft/s 0.65 ft 0.057 4 Ibs/ft2 0.61 Ibs/ft2 6.52 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234675/show 1 /1 11/16/22, 4:38 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >> > VCD 17 Name VCD 17 Discharge 13.42 Channel Slope 0.05 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class B 12-24 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) C125 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern C125 Straight 13.42 cfs 5.79 ft/s 0.61 ft 0.031 2.3 Ibs/ft2 1.89 Ibs/ft2 1.22 STABLE D Unvegetated Underlying Straight 13.42 cfs 5.79 ft/s 0.61 ft 0.031 2.51 Ibs/ft2 1.24 Ibs/ft2 2.02 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 13.42 cfs 3.13 ft/s 0.91 ft 0.072 4 Ibs/ft2 2.83 Ibs/ft2 1.41 STABLE Vegetation Underlying Straight 13.42 cfs 3.13 ft/s 0.91 ft 0.072 4 Ibs/ft2 1.73 Ibs/ft2 2.32 STABLE Substrate hftps://ecmds.com/project/154418/channel-analysis/234678/show 1 /1 Calculate Q10 for roadside ditches - 5 min. Tc RS-1 C = 0.6 i 10 = 6.88 D.A. = 0.15 Q10 = 0.62 cfs RS-2 C = 0.6 i 10 = 6.88 D.A. = 0.19 Q10 = 0.78 cfs RS-3 C = 0.6 i 10 = 6.88 D.A. = 0.12 Q10 = 0.50 cfs RS-4 C = 0.6 i 10 = 6.88 D.A. = 0.11 Q10 = 0.45 cfs RS-5 C = 0.6 i 10 = 6.88 D.A. = 0.11 Q10 = 0.45 cfs RS-6 C = 0.6 i 10 = 6.88 D.A. = 0.07 Q10 = 0.29 cfs RS-7 C = 0.6 i 10 = 6.88 D.A. = 0.14 Q10 = 0.58 cfs RS-8 C = 0.6 i 10 = 6.88 D.A. = 0.2 Q10 = 0.83 cfs RS-9 C = 0.6 i 10 = 6.88 D.A. = 0.43 Q10 = 1.78 cfs RS-10 c = 0.6 i 10 = 6.88 D.A. = 0.12 Q10 = 0.50 cfs RS-11 c = 0.6 i 10 = 6.88 D.A. = 0.24 Q10 = 0.99 cfs RS-12 c = 0.6 i 10 = 6.88 D.A. = 0.26 Q10 = 1.07 cfs RS-13 c = 0.6 i 10 = 6.88 D.A. = 0.09 Q10 = 0.37 cfs RS-14 c = 0.6 i 10 = 6.88 D.A. = 2.54 Q10 = 10.49 cfs RS-15 c = 0.6 i 10 = 6.88 D.A. = 0.32 Q10 = 1.32 cfs RS-16 c = 0.6 i 10 = 6.88 D.A. = 0.43 Q10 = 1.78 cfs RS-17 c = 0.6 i 10 = 6.88 D.A. = 0.42 Q10 = 1.73 cfs RS-18 c = 0.6 i 10 = 6.88 D.A. = 0.86 Q10 = 3.55 cfs RS-19 c = 0.6 i 10 = 6.88 D.A. = 1.21 Q10 = 4.99 cfs RS-20 C = 0.6 i 10 = 6.88 D.A. = 0.15 Q10 = 0.62 cfs RS-21 C = 0.6 i 10 = 6.88 D.A. = 0.19 Q10 = 0.78 cfs RS-22 C = 0.6 i 10 = 6.88 D.A. = 0.32 Q10 = 1.32 cfs RS-23 C = 0.6 i 10 = 6.88 D.A. = 0.33 Q10 = 1.36 cfs RS-24 C = 0.6 i 10 = 6.88 D.A. = 0.48 Q10 = 1.98 cfs RS-25 C = 0.6 i 10 = 6.88 D.A. = 0.26 Q10 = 1.07 cfs RS-26 C = 0.6 i 10 = 6.88 D.A. = 0.78 Q10 = 3.22 cfs RS-27 C = 0.6 i 10 = 6.88 D.A. = 0.38 Q10 = 1.57 cfs RS-28 C = 0.6 i 10 = 6.88 D.A. = 0.18 Q10 = 0.74 cfs RS-29 c = 0.6 i 10 = 6.88 D.A. = 0.77 Q10 = 3.18 cfs RS-30 c = 0.6 i 10 = 6.88 D.A. = 0.82 Q10 = 3.38 cfs RS-31 c = 0.6 i 10 = 6.88 D.A. = 1.46 Q10 = 6.03 cfs RS-32 c = 0.6 i 10 = 6.88 D.A. = 0.83 Q10 = 3.43 cfs RS-33 c = 0.6 i 10 = 6.88 D.A. = 0.58 Q10 = 2.39 cfs RS-34 c = 0.6 i 10 = 6.88 D.A. = 0.65 Q10 = 2.68 cfs RS-35 c = 0.6 i 10 = 6.88 D.A. = 0.43 Q10 = 1.78 cfs NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-1 Name RS-1 Discharge 0.62 Channel Slope 0.0508 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.62 cfs 1.41 ft/s 0.17 ft 0.065 4 Ibs/ft2 0.55 Ibs/ft2 7.25 STABLE Vegetation Underlying Straight 0.62 cfs 1.41 ft/s 0.17 ft 0.065 4 Ibs/ft2 0.45 Ibs/ft2 8.91 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-2 Name RS-2 Discharge 0.78 Channel Slope 0.0365 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.78 cfs 1.31 ft/s 0.22 ft 0.068 4 Ibs/ft2 0.51 Ibs/ft2 7.86 STABLE Vegetation Underlying Straight 0.78 cfs 1.31 ft/s 0.22 ft 0.068 4 Ibs/ft2 0.4 Ibs/ft2 10.05 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-3 Name RS-3 Discharge 0.5 Channel Slope 0.0417 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.5 cfs 1.16 ft/s 0.17 ft Vegetation Underlying Straight 0.5 cfs 1.16 ft/s 0.17 ft Substrate 0.07 4lbs/ft2 0.45lbs/ft2 8.98 STABLE 0.07 4lbs/ft2 0.36lbs/ft2 11.01 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-4 Name RS-4 Discharge 0.45 Channel Slope 0.0214 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.45 cfs 0.79 ft/s 0.22 ft Vegetation Underlying Straight 0.45 cfs 0.79 ft/s 0.22 ft Substrate 0.085 4lbs/ft2 0.29lbs/ft2 13.87 STABLE 0.085 4lbs/ft2 0.23lbs/ft2 17.63 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-5 Name RS-5 Discharge 0.45 Channel Slope 0.0263 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.45 cfs 0.88 ft/s 0.2 ft Vegetation Underlying Straight 0.45 cfs 0.88 ft/s 0.2 ft Substrate 0.08 4lbs/ft2 0.32lbs/ft2 12.31 STABLE 0.08 4lbs/ft2 0.26lbs/ft2 15.43 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-8 Name RS-8 Discharge 0.83 Channel Slope 0.0326 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.83 cfs 1.27 ft/s 0.24 ft Vegetation Underlying Straight 0.83 cfs 1.27 ft/s 0.24 ft Substrate 0.069 4lbs/ft2 0.49lbs/ft2 8.16 STABLE 0.069 4lbs/ft2 0.38lbs/ft2 10.56 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-9 Name RS-9 Discharge 1.78 Channel Slope 0.0432 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.78 cfs 2.01 ft/s 0.3 ft 0.057 4 Ibs/ft2 0.82 Ibs/ft2 4.87 STABLE Vegetation Underlying Straight 1.78 cfs 2.01 ft/s 0.3 ft 0.057 4 Ibs/ft2 0.61 Ibs/ft2 6.57 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-10 Name RS-10 Discharge 0.5 Channel Slope 0.0273 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.5 cfs 0.93 ft/s 0.2 ft Vegetation Underlying Straight 0.5 cfs 0.93 ft/s 0.2 ft Substrate 0.078 4lbs/ft2 0.35lbs/ft2 11.46 STABLE 0.078 4lbs/ft2 0.28lbs/ft2 14.45 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-11 Name RS-11 Discharge 0.99 Channel Slope 0.0709 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.99 cfs 2.04 ft/s Vegetation Underlying Straight 0.99 cfs 2.04 ft/s Substrate 0.19 ft 0.055 0.19 ft 0.055 4lbs/ft2 0.83lbs/ft2 4lbs/ft2 0.67lbs/ft2 4.8 STABLE -- 5.97 STABLE -- NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-12 Name RS-12 Discharge 1.07 Channel Slope 0.0709 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.07 cfs 2.11 ft/s 0.2 ft 0.054 4 Ibs/ft2 0.87 Ibs/ft2 4.62 STABLE Vegetation Underlying Straight 1.07 cfs 2.11 ft/s 0.2 ft 0.054 4 Ibs/ft2 0.69 Ibs/ft2 5.78 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-13 Name RS-13 Discharge 0.37 Channel Slope 0.0308 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.37 cfs 0.87 ft/s 0.17 ft Vegetation Underlying Straight 0.37 cfs 0.87 ft/s 0.17 ft Substrate 0.08 4lbs/ft2 0.32lbs/ft2 12.32 STABLE 0.08 4lbs/ft2 0.27lbs/ft2 15.08 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-14 Name RS-14 Discharge 10.49 Channel Slope 0.0318 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 10.49 cfs 3.32 ft/s 0.74 ft 0.048 4 Ibs/ft2 1.48 Ibs/ft2 2.71 STABLE Vegetation Underlying Straight 10.49 cfs 3.32 ft/s 0.74 ft 0.048 3.63 Ibs/ft2 0.93 Ibs/ft2 3.9 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-15 Name RS-15 Discharge 1.32 Channel Slope 0.0422 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.32 cfs 1.76 ft/s 0.27 ft 0.06 4 Ibs/ft2 0.71 Ibs/ft2 5.67 STABLE Vegetation Underlying Straight 1.32 cfs 1.76 ft/s 0.27 ft 0.06 4 Ibs/ft2 0.54 Ibs/ft2 7.47 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-16 Name RS-16 Discharge 1.78 Channel Slope 0.0314 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.78 cfs 1.69 ft/s 0.35 ft 0.062 4 Ibs/ft2 0.68 Ibs/ft2 5.89 STABLE Vegetation Underlying Straight 1.78 cfs 1.69 ft/s 0.35 ft 0.062 4 Ibs/ft2 0.49 Ibs/ft2 8.12 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-17 Name RS-17 Discharge 1.73 Channel Slope 0.0264 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.73 cfs 1.52 ft/s 0.37 ft 0.065 4 Ibs/ft2 0.61 Ibs/ft2 6.61 STABLE Vegetation Underlying Straight 1.73 cfs 1.52 ft/s 0.37 ft 0.065 4 Ibs/ft2 0.43 Ibs/ft2 9.21 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-18 Name RS-18 Discharge 3.55 Channel Slope 0.0405 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 3.55 cfs 2.54 ft/s Vegetation Underlying Straight 3.55 cfs 2.54 ft/s Substrate 0.43 ft 0.053 0.43 ft 0.053 4 Ibs/ft2 1.08 Ibs/ft2 4lbs/ft2 0.75lbs/ft2 3.71 STABLE -- 5.32 STABLE -- NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-19 Name RS-19 Discharge 4.99 Channel Slope 0.0382 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 4.99 cfs 2.8 ft/s 0.51 ft 0.051 Vegetation Underlying Straight 4.99 cfs 2.8 ft/s 0.51 ft 0.051 Substrate 4 Ibs/ft2 1.21 Ibs/ft2 4lbs/ft2 0.82lbs/ft2 3.31 STABLE -- 4.9 STABLE -- NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-20 Name RS-20 Discharge 0.62 Channel Slope 0.0276 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.62 cfs 1.03 ft/s 0.23 ft Vegetation Underlying Straight 0.62 cfs 1.03 ft/s 0.23 ft Substrate 0.076 4lbs/ft2 0.39lbs/ft2 10.31 STABLE 0.076 4lbs/ft2 0.3lbs/ft2 13.19 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-21 Name RS-21 Discharge 0.78 Channel Slope 0.0333 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.78 cfs 1.25 ft/s 0.23 ft Vegetation Underlying Straight 0.78 cfs 1.25 ft/s 0.23 ft Substrate 0.069 4lbs/ft2 0.48lbs/ft2 8.3 STABLE 0.069 4lbs/ft2 0.37lbs/ft2 10.68 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-22 Name RS-22 Discharge 1.32 Channel Slope 0.0304 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.32 cfs 1.47 ft/s 0.31 ft 0.066 4 Ibs/ft2 0.58 Ibs/ft2 6.87 STABLE Vegetation Underlying Straight 1.32 cfs 1.47 ft/s 0.31 ft 0.066 4 Ibs/ft2 0.43 Ibs/ft2 9.27 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-23 Name RS-23 Discharge 1.36 Channel Slope 0.036 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.36 cfs 1.63 ft/s 0.29 ft 0.062 4 Ibs/ft2 0.65 Ibs/ft2 6.14 STABLE Vegetation Underlying Straight 1.36 cfs 1.63 ft/s 0.29 ft 0.062 4 Ibs/ft2 0.49 Ibs/ft2 8.2 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-24 Name RS-24 Discharge 1.98 Channel Slope 0.0426 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.98 cfs 2.08 ft/s 0.32 ft 0.056 4 Ibs/ft2 0.85 Ibs/ft2 4.68 STABLE Vegetation Underlying Straight 1.98 cfs 2.08 ft/s 0.32 ft 0.056 4 Ibs/ft2 0.63 Ibs/ft2 6.37 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-25 Name RS-25 Discharge 1.07 Channel Slope 0.0288 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.07 cfs 1.31 ft/s 0.28 ft Vegetation Underlying Straight 1.07 cfs 1.31 ft/s 0.28 ft Substrate 0.069 4lbs/ft2 0.51lbs/ft2 7.82 STABLE 0.069 4lbs/ft2 0.38lbs/ft2 10.41 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-27 Name RS-27 Discharge 1.57 Channel Slope 0.0193 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.57 cfs 1.23 ft/s 0.4 ft Vegetation Underlying Straight 1.57 cfs 1.23 ft/s 0.4 ft Substrate 0.072 4lbs/ft2 0.48lbs/ft2 8.32 STABLE 0.072 4lbs/ft2 0.34lbs/ft2 11.78 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-28 Name RS-28 Discharge 0.74 Channel Slope 0.0323 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 0.74 cfs 1.2 ft/s 0.23 ft Vegetation Underlying Straight 0.74 cfs 1.2 ft/s 0.23 ft Substrate 0.071 4lbs/ft2 0.46lbs/ft2 8.66 STABLE 0.071 4lbs/ft2 0.36lbs/ft2 11.12 STABLE NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-29 Name RS-29 Discharge 3.18 Channel Slope 0.0366 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 3.18 cfs 2.3 ft/s 0.42 ft 0.055 4 Ibs/ft2 0.96 Ibs/ft2 4.15 STABLE Vegetation Underlying Straight 3.18 cfs 2.3 ft/s 0.42 ft 0.055 4 Ibs/ft2 0.67 Ibs/ft2 5.93 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-30 Name RS-30 Discharge 3.38 Channel Slope 0.0302 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 3.38 cfs 2.11 ft/s 0.47 ft 0.057 4 Ibs/ft2 0.88 Ibs/ft2 4.53 STABLE Vegetation Underlying Straight 3.38 cfs 2.11 ft/s 0.47 ft 0.057 4 Ibs/ft2 0.61 Ibs/ft2 6.61 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-31 Name RS-31 Discharge 6.03 Channel Slope 0.0265 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 6.03 cfs 2.44 ft/s Vegetation Underlying Straight 6.03 cfs 2.44 ft/s Substrate 0.63 ft 0.055 0.63 ft 0.055 4 Ibs/ft2 1.05 Ibs/ft2 4lbs/ft2 0.68lbs/ft2 3.82 STABLE -- 5.89 STABLE -- NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-32 Name RS-32 Discharge 3.43 Channel Slope 0.0426 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 3.43 cfs 2.58 ft/s Vegetation Underlying Straight 3.43 cfs 2.58 ft/s Substrate 0.41 ft 0.052 0.41 ft 0.052 4 Ibs/ft2 1.09 Ibs/ft2 4lbs/ft2 0.77lbs/ft2 3.66 STABLE -- 5.2 STABLE -- NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-33 Name RS-33 Discharge 2.39 Channel Slope 0.0243 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 2.39 cfs 1.64 ft/s 0.44 ft 0.064 4 Ibs/ft2 0.66 Ibs/ft2 6.02 STABLE Vegetation Underlying Straight 2.39 cfs 1.64 ft/s 0.44 ft 0.064 4 Ibs/ft2 0.46 Ibs/ft2 8.66 STABLE Substrate NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-34 Name RS-34 Discharge 2.68 Channel Slope 0.0241 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 2.68 cfs 1.71 ft/s Vegetation Underlying Straight 2.68 cfs 1.71 ft/s Substrate 0.46 ft 0.063 4 Ibs/ft2 0.7 Ibs/ft2 5.75 STABLE -- 0.46 ft 0.063 4 Ibs/ft2 0.48 Ibs/ft2 8.36 STABLE -- NORTH AMERICAN GREEN CHANNELANALYSIS > > > RS-35 Name RS-35 Discharge 1.78 Channel Slope 0.0439 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 1.78 cfs 2.02 ft/s 0.3 ft 0.057 4 Ibs/ft2 0.83 Ibs/ft2 4.84 STABLE Vegetation Underlying Straight 1.78 cfs 2.02 ft/s 0.3 ft 0.057 4 Ibs/ft2 0.61 Ibs/ft2 6.51 STABLE Substrate