HomeMy WebLinkAboutWQ0043958_Application_20221129Division of Water Resources
State of North Carolina
Department of Environmental Quality
Division of Water Resources
FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 06-21 & SUPPORTING DOCUMENTATION
Application Number: 1AI `�Cn�IYi 0 U (to be completed by DWR)
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
WOROS
MOORESVILLE REGI�ON1L OFFICE
1. Applicant's name: Dominion Realty Partners, LLC (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership
❑ Federal ❑ State/County ❑ Municipal
3. Signature authority's name: Joe Murray per 15A NCAC 02T .0106(b)
Title: Vice President
4. Applicant's mailing address: 101 N. 5' St
City: Richmond State: VA Zip: 23219-
5. Applicant's contact information:
Phone number: (919) 582-2050 Email Address: jmurray@DRP-LLC.com
II. PROJECT INFORMATION:
1. Project name: The Exchange
2. Application/Project status:
❑ Privately-OwnedtthhaarrPublic Utility
❑ OUitbEIVED/NCDEQ/DWR
Nf2 9 2022
WQROS
MOORESVILLE REGIONAL OFFICE
® Proposed (New Permit) ❑ Existing Permit/Project
If a modification, provide the existing permit number: WQ00 and issued date:
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Mecklenburg
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.170803° Longitude: -80.882049°
5. Parcel ID (if applicable): 169-052-06 (or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Matthew Weschler License Number: 048124
Firm: Land Design
Mailing address: 223 N. Graham St
City: Charlotte State: NC Zip: 28202-
Phone number: (704) 333-0325 Email Address: mweschlernn,Ianddesign.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: McAlpine Creek Permit Number: NC00024970
Owner Name: City of Charlotte
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s): WQ
2. Downstream (Receiving) Sewer Information: 8 inch r Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCS
Owner Name(s):
FORM: FTA 06-21
Page 1 of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes El No ®N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes El No ®N/A
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and
supplementary documentation as required by 15A NCAC 02T.0115(c) been attached?
❑Yes ❑No ®N/A
4. Origin of wastewater: (check all that apply):
❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls)
® Residential (Leased) ❑ Retail with food preparation/service
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities
❑ Food and drink facilities ❑ Church
❑ Businesses / offices / factories ❑ Nursing Home
El Car Wash
❑ Hotel and/or Motels
Swimming Pool/Clubhouse
El Swimming Pool/Filter Backwash
❑ Other (Explain in Attachment)
11
5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20))
If Industrial, is there a Pretreatment Program in effect? El Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .0114(0? ❑ Yes ® No
➢ If ves, provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(I))
Daily Design Flow a,b
No. of Units
Flow
Multi -Family Apartments
135 gal/day
79
10,665 GPD
Townhomes
190 gal/day
12
2,280 GPD
Pool
10 gal/day/person
304
3,040 GPD
Amenity Center
50 gal/100 SF
5,516
2,758 GPD
Total
18,743 GPD
a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i e , minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 40.613 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
❑ Flow has already been allocated in Permit Number: Issuance Date:
❑ Rehabilitation or replacement of existing sewers with no new flow expected
❑ Other (Explain):
FORM: FTA 06-21
Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8
252
PVC
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -
3. Total number of pumps at the pump station:
3. Design flow of the pump station: millions gallons per day (firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s):
gallons per minute (GPM) at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) 1 Length (feet)
Material
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify)
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B):
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
FORM: FTA 06-21 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (a)? ® Yes ❑ No
15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
18 inches
2Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
2Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
10 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
➢ If noncompliance with 02T.0305(f) or (a). see Section X.1 of this application
*15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpage
2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A
➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ❑ N/A
➢ Please provide supplementary information identifying the areas of non-conformance.
➢ See the Division's draft separation requirements for situations where separation cannot be met.
➢ No variance is required if the alternative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No
If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No
➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes /1 No
or 401 Water Quality Certifications?
> Please provide the permit number/permitting status in the cover letter if coverage/authorization is required.
6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No
Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
> If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
FORM: FTA 06-21 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer
review times. For projects requiring two or more variances or where the variance is determined by the Division to be a
significant portion of the project, the full technical review is required.
2. Professional Engineer's Certification:
1, Matthew Weschler
, attest that this application for The Exchange
(Professional Engineer's name from Application Item I11.1.) (Project Name from Application Item 11.1)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application
information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
11/29/2022
I, Joe Murray , attest that this application for The Exchange
(Signature Authority Name from Application Item 1.3.) (Project Name from Application Item 11.1)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Digitally signed by Josoph Murray
DN. C=US, E=JMurray@drp Ilc.com, CN=Josoph Murray
Joseph Murray Location Rale'gh
Reason. I agree to the terms defined by the placement of
my signature on this document
Signature: Date. 2022 11.29 11 52 43 05'00'
Date:
FORM: FTA 06-21 Page 5 of 5
LandDesign.
CREATING PLACES
THAT MATTER.
October 27, 2022
The Exchange Mutli-family Development
LDI Project No. 1021134
SEWER SYSTEM APPLICANT:
Dominion Realty Partners, LLC
101 N. 5th Street
Richmond, VA 23219
DEVELOPER:
Dominion Realty Partners, LLC
101 N. 5th Street
Richmond, VA 23219
DESCRIPTION:
RECEIVED/NCDEQ/DWR
NOV 1 6 2022
UVOROS
MOORESVILLE REGIONAL. OFFICE
We would like to request approval for sewer extension to the project site of The Exchange.
The proposed buildings contributing flow to the private sewer extension will include ofive multi-
family apartment building (240 units), three townhome complexes (12 units), and a pool. The
total wastewater flow requested and approved for the entire project was 40,613 gpd. The
private sewer extension will allocate a total flow of 18,743 gpd to the public system. We are
proposing to install 252 LF of 8" PVC. Flows from the site will be sent to the McAlpine Creek
Wastewater Treatment Plants (facility permit number NC0024970). This application package
consists of the Fast Track sewer system extension application, the application fee, the flow
tracking and acceptance form from Charlotte Water, a USGS topographic map indicating the
location of the project, a street level map showing the project area, and articles of organization
for DRP.
Respectfully Submitted,
Matthew Weschler, PE
LandDesign, Inc.
LANDDESIGN.COM
223 N GRAHAM STREET • CHARLOTTE NC 28202 704 333 0325
CHARLOTTE • WASHINGTON DC • DALLAS • ORLANDO - SAN FRANCISCO
CHARLOTTE
WTER
July 19, 2022
Mrs. Jessica Hertzberg
LandDesign
223 North Graham Street
Charlotte, NC 28202
SUBJECT: WATER AND SEWER FLOW ACCEPTANCE
THE EXCHANGE
316 ROUNTREE ROAD, CHARLOTTE, NC 28217
CLTWATER TRACKING# 20224716
After analysis of the sanitary sewer associated with the proposed design of project, 20224716, THE
ECHANGE, it was determined that there is sufficient capacity to accommodate the proposed sewer
flow of 40,613 gallons per day (241 units x 135 gpd/unit; 12 units x 190 gpd/unit; 304 people x 10
gpd/person; 5,516 sfx 50 gpd/100 sf) at the connection point(s) indicated on the submitted utility
plan for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number
NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the
designated publicly owned treatments works.
Please see attached NCDEQ-FTSE form.
Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the
subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water
Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of
NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow.
The applicant should understand that due to the involvement of other agencies and continuing
growth of the water and sewer system, the ability to provide service for future projects cannot be
guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first
come, first served basis.
The applicant should understand that this letter is not authorization to construct or extend private
water or sewer systems, as the appropriate local or State permits are required prior to construction.
If the appropriate authorization to construct permits are not obtained, construction has not started
within two (2) years of issuance of this flow acceptance, and payment for anv service connections
have not been received within two (2) years of issuance of this flow acceptance letter, this flow
acceptance approval shall be rescinded, and a new flow acceptance request must be made.
If you have any questions, please do not hesitate to contact me at (704) 432-5801.
Sincerely,
vox,- A svzc,4
Guillermo Anzola / Engineering Assistant
CHARLOTTE WATER / charlottewater.orq
Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org
Operated by the City of Charlotte
State of North Carolina
Department of Environmental Quality
Division of Water Resources
Flow Tracking for Sewer Extension Applications
(FTSE 10-18)
Entity Requesting Allocation: Land Design
Project Name for which flow is being requested: The Exchange (MF on Roundtree Rd)
More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek
b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937
All flows are in MGD
c. WWTP facility's permitted flow 99.00
d. Estimated obligated flow not yet tributary to the WWTP 15.063
e. WWTP facility's actual avg. flow
f. Total flow for this specific request
g. Total actual and obligated flows to the facility
h. Percent of permitted flow used
65.766
0.040613
80.871
81.7%
II. Complete this section for each pump station you are responsible for along the route of this proposed
wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A) (B) (C) (D)=(B+C) (E)=(A-D)
Design Obligated,
Pump Pump Average Approx. Not Yet Total Current
Station Station Firm Daily Flow** Current Tributary Flow Plus
(Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available
Number) No. MGD MGD Flow, MGD MGD Flow Capacity***
* The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow
that can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor
(pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < O.
Downstream Facility Name (Sewer): Trunk to Chastain & Springbrook
Downstream Permit Number: Unknown
Page 1 of 2
FTSE 10-18
III. Certification Statement:
Keri Cantrell certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any
capacity related sanitary sewer overflows or overburden any downstream pump station en route to the
receiving treatment plant under normal circumstances, given the implementation of the planned
improvements identified in the planning assessment where applicable. This analysis has been performed
in accordance with local established policies and procedures using the best available data. This
certification applies to those items listed above in Sections I and II plus all attached planning assessment
addendums for which I am the responsible party. Signature of this form certifies that the receiving
collection system or treatment works has adequate capacity to transport and treat the proposed new
wastewater.
(KN;
Digitally signed by Keri Cantrell
Date: 2022.07.19 10:10:38 -04'00' 7/19/2022
Adobe Acrobat version: 2022.001.20117
Signing Official Signature Date
Chief Engineer
Title of Signing Official
Page 2 of 2
FTSE 10-18
Polaris 3G Map — Mecklenburg County, North Carolina
Date Printed: 10/26/2022 2:11:59 PM
i nis map or report is preparea tortne inventory of real property witnin mecKienourg county ana is compiiea rrom recoraea aeeas, plats, tax maps, surveys,
planimetric maps, and other public records and data. Users of this map or report are hereby notified that the aforementioned public primary information sources
should be consulted for verification. Mecklenburg County and its mapping contractors assume no legal responsibility for the information contained herein.
.1259 NJ
-II 0000
UVGV U.S. DEPARTMENT U.S. GEOLOGICAL SURVEY
u�.a.w..a..w
Ere>ce<Ey Uro UMIM DANN GANA.AN k n
SCALE 1:24000
.1613
u ,mo NCO xro 40, 5000 ONO rae uoe sow ,mm
Ayr
CHARLOTTE WEST QUADRANGLE
NORTH CAROLINA • MECKLENBURG COUNTY
7.S.MINUTE SERIES
CHARLOTTE WEST, NC
2021
North Carolina Secretary of State Search Results Page 1 of 1
• File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online •
Add Entity to My Email Notification List • View Filings • Print a Pre -Populated Annual Report form • Print
an Amended a Annual Report form
Limited Liability Company
Legal Name
Dominion Realty Partners LLC
Information
Sosld: 0814581
Status: Current -Active
Date Formed: 11/28/2005
Citizenship: Domestic
Annual Report Due Date: April 15th
CurrentAnnual Report Status:
Registered Agent: Andrews, Alexander B., IV
Addresses
Mailing Principal Office Reg Office
501 Fayetteville St, Ste 100 501 Fayetteville St, Ste 100 501 Fayetteville St, Ste 100
Raleigh, NC 27601 Raleigh, NC 27601 Raleigh, NC 27601
Reg Mailing
501 Fayetteville St, Ste 100
Raleigh, NC 27601
Company Officials
All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20.
Chief Executive Officer Manager
Alexander B. Andrews , IV DRP Holdings, LLC
501 Fayetteville St, Ste 100 2626 Glenwood Ave, Suite 195
Raleigh NC 27601-3068 Raleigh NC 27608
https://www.sosnc.gov/online_services/search/Business_Registration_Results 11/18/2022