HomeMy WebLinkAboutWQ0043952_Application_20221129DocuSign Envelope ID: 7D807F8D-2CC1-49FA-9BCA-674F974E57A2
WOROS
I. APPLICANT INFORMATION: AOORESVILLE REGIONAL OFFICE
2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
State of North Carolina
DW R Department of Environmental Quality
Division of Water Resources
FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION
Ht,tIVEDIPICDE®1' SCR'
Application Number: k(Qo -> I'7`3�°J (to be completed by DWR) �'
Nov 2 3 2TLZ
All items must be completed or the application will be returned
1. Applicant's name: Dynamo Holdings, LLC (company, municipality, HOA, utility, etc.)
❑ Federal ❑ State/County ❑ Municipal
3. Signature authority's name: Igor Shipper per 15A NCAC 02T .0106(b)
Title: Manager
4. Applicant's mailing address: 118 Charing Place
City: Mooresville State: NC Zip: 28117-
5. Applicant's contact information:
Phone number: (919) 274-3200 Email Address: dynamoholdings.cltna,gmail.com
❑ Other
II. PROJECT INFORMATION:
1. Project name: Petes Rd Duplexes
2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project
If a modification, provide the existing permit number: WQ00 and issued date:
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Lincoln
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.445003° Longitude: -80.272435°
5. Parcel ID (if applicable): 100155, 105980, 105981, 105982, 105983, & 105984 (or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Josh Butler License Number: 048418
Finn: Gateway Design Group, PLLC
Mailing address: 15126 Castlebridge Lane
City: Matthews State: NC Zip: 28104-
Phone number: (910) 840-2661 Email Address: josh(agatewavdesigngroup.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: Lincolnton WWTP Permit Number: NC0025494
Owner Name:
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s): WQ
2. Downstream (Receiving) Sewer Information: inch
❑ Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCS
Owner Name(s):
FORM: FTA 06-21
Page 1 of 5
DocuSign Envelope ID: 7D807F8D-2CC1-49FA-9BCA-674F974E57A2
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑ No ® N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑ No ®N/A
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and
supplementary documentation as required by 15A NCAC 02T.0115(c) been attached?
❑ Yes ❑ No ® N/A
4. Origin of wastewater: (check all that apply):
® Residential (Individually Owned)
❑ Residential (Leased)
❑ School / preschool / day care
❑ Food and drink facilities
❑ Businesses / offices / factories
❑ Retail (stores, centers, malls)
❑ Retail with food preparation/service
0 Medical / dental / veterinary facilities
0 Church
❑ Nursing Home
0 Car Wash
0 Hotel and/or Motels
0 Swimming Pool/Clubhouse
0 Swimming Pool/Filter Backwash
0 Other (Explain in Attachment)
5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20))
If Industrial, is there a Pretreatment Program in effect? 0 Yes 0 No
6. Has a flow reduction been approved under 15A NCAC 02T .0114(0? 0 Yes ® No
➢ If ves, provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow 0'
No. of Units
Flow
3 bedroom units
360 gal/
12
4,320 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
4,320 GPD
a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 4,320 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
❑ Flow has already been allocated in Permit Number: Issuance Date:
0 Rehabilitation or replacement of existing sewers with no new flow expected
0 Other (Explain):
FORM: FTA 06-21
Page 2 of 5
DocuSign Envelope ID: 7D807F8D-2CC1-49FA-9BCA-674F974E57A2
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8"
786
PVC
8"
78
DIP
U II
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
> Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - .
3. Total number of pumps at the pump station:
3. Design flow of the pump station: millions gallons per day (firm capacity)
> This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify)
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B):
> Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
> Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
> Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
FORM: FTA 06-21 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(t) & (g)?
15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
® Yes ❑ No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
18 inches
2Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
'Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
10 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application
*15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpage
2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A
➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands?
➢ Please provide supplementary information identifying the areas of non-conformance.
➢ See the Division's draft separation requirements for situations where separation cannot be met.
➢ No variance is required if the alternative design criteria specified is utilized in design and construction.
❑Yes El No ZN/A
4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Catawba
If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200?
➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage/authorization under a 404 Nationwide/individual permits
or 401 Water Quality Certifications?
➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is re
❑ No
® Yes ❑ No
❑ Yes ® No
quired.
6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No
Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
FORM: FTA 06-21 Page 4 of 5
DocuSign Envelope ID: 7D807F8D-2CC1-49FA-9BCA-674F974E57A2
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
®Yes ❑No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
concurrently with the approval of the permit, and projects requiring a variance approval may be subject to loner
review times. For projects requiring two or more variances or where the variance is determined by the Division to be a
significant portion of the project, the full technical review is required.
2. Professional Engineer's Certification:
Josh Butler
, attest that this application for Petes Rd Duplexes
(Professional Engineer's name from Application Item III.1.) (Project Name from Application Item II.1)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misreta a3tjt_application
information, including failure to disclose any design non-compliance with the ap icable Rules andidesiginiTten7, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing . • ard. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date
3. Applicant's Certification per 15A NCAC 02T .0106(b):
Igo r
I, , attest that this application for
(Signature Authority Name from Application Item 1.3.)
ess 4'''
SEAL
048418
s
CN
Petes Rd Duplexes
(Project Name from Application Item II.1)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
DocuSigned by:
LLr
Signature: o67c9o9Bc4o8...
Date:
11/21/2022
FORM: FTA 06-21 Page 5 of 5
State of North Carolina
Department of Environment and Natural Resources
Division of Water Resources
Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 08-13)
Project Applicant Name: Dynamo Holdings, LLC
Project Name for which flow is being requested: Petes Rd Duplexes
More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater, flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: Lincolnton WWTP
b. WWTP Facility Permit #: NC0025496
Allf1`aws are in MGD
c. WWTP facility's permitted flow 6.0
d. Estimated obligated flow not yet tributary to the WWTP 1.26
e. WWTP facility's actual avg. flow
f. Total flow for this specific request
g. Total actual and obligated flows to the facility
h. Percent of permitted flow used
1.641
0.00432
2.901
45.35%
II. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A) (B) (C) (D)=(B+C) (E)==(A-D)
Design Obligated,
Pump Average Daily Approx. Not Yet Total Current
Station Firm Flow** Current Avg. Tributary Flow Plus
(Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available
Number) MGD MGD MGD MGD Flow Capacity***
Hwy 150
0.310 0.124 0.024 0 0.024 0.100
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pi) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Page 1 of 6
I"TSE 08-13
III. Certification Statement:
I iC' .CO 1,1avinQ f certify to the best of my knowledge that the addition of
the volume of wastewatetrto be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessment addendums for which I am the responsible party. Signature of this
form indicates acceptance of this wastewater flow.
49ciat Signature/045r/b
Date
Page 2 of 6
FUSE 08-13
DocuSign Envelope ID: 4C43FB5A-06C2-49CE-8356-B42B23DA2EC9
FORM WSCAS 08-13
WATERSHED CLASSIFICATION ATTACHMENT
FOR SEWER SYSTEMS
Applicant Name
Project Name
Dynamo Holdings, LLC
Fetes Rd Duplexes
Professional Engineer Name
Engineering Firm Name
Josh Butler, P.E.
Gateway Design Group, PLLC
Location
ID
Name of Waterbody'
County
River
Basin
Waterbody
Stream Index No.
Waterbody
Classification
A
South Fork Catawba Rivert
Lincoln
Catawba
11-129-7
C
1 If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to w,
I certify that as a Registered Professional Engineer in the State of
North Carolina that I have diligently followed the Division's
instructions for classifying waterbodies and that the above
classifications are inclusive of the stated project, complete and
correct to the best of my knowledge and belief.
PE Seal, Signature and Date
*** END OF FORM WSCAS 08-13 ***
DocuSigned by:
h the unnamed tributary joins.
FORM: WSCAS 08-13
Page 1 of 1
11/21/22, 5:39 AM North Carolina Secretary of State Search Results
• File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online •
Add Entity to My Email Notification List • View Filings • Print a Pre -Populated Annual Report form • Print
an Amended a Annual Report form
Limited Liability Company
Legal Name
Dynamo Holdings, LLC
Information
Sosld: 2149553
Status: Current -Active 0
Date Formed: 3/12/2021
Citizenship: Domestic
Annual Report Due Date: April 15th
CurrentAnnual Report Status:
Registered Agent: Shiper, Igor
Addresses
Mailing Principal Office Reg Office Reg Mailing
205 S. Academy St 205 S. Academy St 205 S. Academy St 205 S. Academy St
Lincolnton, NC 28092 Lincolnton, NC 28092 Lincolnton, NC 28092 Lincolnton, NC 28092
Company Officials
All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20.
Member Managing Member Member
Sergii Abramenko Igor Shiper Vladimir Strela
205 S Academy St 205 S Academy St 1218 High Brook Dr
Lincolnton NC 28092 Lincolnton NC 28092 Waxhaw NC 28173
https://www.sosnc.gov/online_services/search/Business_Registration_Results 1/1
PARTMENT OF THE
w.W�V U.S. U.S. GEO1 OG1CAL SURVEY INTERIOR
.wan.nM+vroJ
P.
tM USS State G. IflkLN Survey
ION
4; US TOpo
SCALE 1:24 000
IMO
WAS
e NOQ IOW .00 WV HOP MI env MOO
LINCOLNTON WEST QUADRANGLE
NORTH COMM
T.S.AVNUTE SERIES
•^ W.w.. fjwu,..
UNCOLNTON WEST, NC
2021