Loading...
HomeMy WebLinkAboutSW4220301_Application Form_20221214SUPPLEMENT-EZ COVER PAGE FORMS LOADED ECT INFORMATION Project Name Proiect Area (ac) Surface Water Area (ac) Is this project High or Low Density? Does this proiect use an off -site SCM? Woodhaven Subdivision 16.9 0 No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 30 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 113ayfilter 0 26 IFilterra 0 FORMS LOADED CERTIFICATION Email: Ravindra Bissram, PE Fleming Engineering, Inc. 8 NC 27235 Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. C z v' 027436 GIN E�QQ�, Seal Signature of Designer Date December 14, 2022 DRAINAGE AREAS 1 Is this a hi h density project? No 2 If so number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM NONE NONE 5 Total drainage area (sq ft 737950 737950 6 Onsite drainage area (sq ft 737950 737950 7 Offsite drainage area (sq ft 0 0 8 Total BUA in project (sq ft 152460 sf 152460 sf 9 New BUA on subdivided lots (subject to ermitting) (sq ft 98000 sf 98000 sf 10permitting) New BUA not on subdivided lots (subject to s 54460 sf 54460 sf 11 Offsite BUA (sq ft sf sf 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft 1850 sf 1850 sf Sidewalk (sq ft 9300 sf 9300 sf Roof (sq ft sf Roadway s ft 40030 sf 40030 sf Future (sq ft 3280 sf 3280 sf Other, please specify in the comment box below (sq ft 13 New infiltrating permeable pavement on isubdivided lots (sq ft sf sf 14 New infiltrating permeable pavement not on subdivided lots (sq ft sf sf 15permitting) Existing BUA that will remain (not subject to s ft sf sf 16 Existing BUA that is already permitted (sq ft sf sf 17 Existing BUA that will be removed (sq ft sf sf 18 Percent BUA 21 % 21 % 19 Design storm inches 20 IDesiqn volume of SCM cu ft na na 21 lCalculation method for design volume na na ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): Item 12 "Future" Verdant Lane is not required to be installed at this time and is considered as future ISA. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 021-1.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 3 to 1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 9.32 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s) (feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 JAre variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 1 Please use this space to provide any additional information about this low density project: 17.9 Acres of offsite drainage area flow to the western property line as indicated in information provided in the packet. Swale information is updated and conforms with exhibits in this package. Velocities prior/during/after stablization conform with manufacturers specifications for Curlex I, Curex II, and Pyramat (specs previously submitted). Swale # Drainage Area ac BUA (ac) Pervious area ac C Q (cfs) Slope N V,11- (fps) V.�., (fps) Flow depth (ft) 1 0.13 0.08 0.05 0.80 0.72 4.00 5.00 3.32 0.06 2 0.10 0.03 0.07 0.65 0.45 2.00 5.00 2.29 0.06 3 0.08 0.03 0.05 0.65 0.36 4.00 5.00 2.71 0.04 4 1 1.71 0.20 1.51 0.60 1 7.06 3.00 5.00 4.36 0.41 5 0.33 0.14 0.19 0.80 1.82 3.00 5.00 3.69 0.14 6 1.53 0.11 1.42 0.60 6.32 2.20 5.00 3.76 0.42 7 0.33 0.10 0.23 0.65 1.48 9.60 5.00 4.17 0.08 8 0.33 0.10 0.23 0.65 1.48 40.00 25.00 9.32 0.05 9 2.76 0.38 2.38 0.60 11.39 1.80 5.00 3.71 1 0.77 10 2.77 0.25 1 2.52 0.60 1 11.43 1.50 5.00 3.42 0.84 11 0.29 0.11 0.18 0.65 1.30 2.10 5.00 3.00 0.13 12 0.22 0.09 0.13 0.65 0.98 1.80 5.00 2.32 0.11 13 0.83 0.04 0.79 0.60 3.43 13.40 5.00 4.79 0.11 14 12.88 0.02 12.86 0.50 44.31 4.30 7.00 2.82 1.75 15 0.39 0.13 0.26 0.60 1.61 7.80 5.00 4.46 0.09 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30