HomeMy WebLinkAboutNC0032131_Wasteload Allocation_19920820NPDES WASTE LOAD ALLOCATION
PERMIT NO.: NCO032131
PERMITI'EE NAME: Tweetsie Railroad Inc.
FACILITY NAME: Tweetsie Railroad Inc.
Facility Status: Existing
Permit Status: Renewal
Major
Pipe No.: 001
Design Capacity:
Minor
0.070 MGD
Domestic (% of Flow):
Industrial (% of Flow):
Comments:
RECEIVING
Class: WS-III-Trout
100 %
1
the Middle Fork of the South Fork of the New River
Sub -Basin: 05-07-01
Reference USGS Quad: C12NW (please attach)
County: Watauga
Regional Office: Winston-Salem Regional Office
Previous Exp. Date: 11/30/92 Treatment Plant Class:
Classification changes within three miles:
change to WS-III at Boone Dam.
Requested b :,I Randy Kepler Date: 4/28/92
Prepared by: Date: d' 7 L
Reviewe b Date: 9 1
Modeler
Date Rec.
I #
zvt3
S t qz
Oo
Drainage Area (mil ) 9 6 Avg. Streamflow (cfs): /9
7Q10 (cfs) 9 s Winter 7Q10 (cfs) SS 30Q2 (cfs) 87
Toxicity Limits: IWC
Instream Monitoring:
% Acute/Chronic
Parameters
Upstream Location
Downstream Location
Effluent
Characteristics
Summer
Winter
BOD5 (mg/1)
30
NH3-N (mg/1)
26
D.O. (mg/1)
kvzdw,;�^,
TSS (mg/1)
3o
F. Col. (/100 ml)
Leo
pH (SU)
6 - i
4d�E Cl�
6 7 u LC
Comments:
lt
Q(
�-003
I�� .I�?< _../ / s N tz0•. ` tf��\snp-
O
-
- , •
, ( rant
A\
.—
rum
i
7l�'Ecim P rk • = U - ENTRAL FILE COPY
Wtn-
rA
\ r:` `• _.11%l.� _.�\ `� I;��\\ `L:�\\\l\\� N.
`• ��lii:;,((�, i ._., `�•.,,c:+m':\ \� �'�-36`07'30'
"41 ........... ..m..,w_.°°_
4430ea°-E.
i. i
A. (_). EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS Final
NPDES No. NCO032131
Daring the period beginning on the effective date of the Permit and lasting until expansion above 0.0024
MGD, the Permittee is authorized to discharge from outfall(s) serial number(s) 001. Such discharges shall be_ limited and monitored by the Permittee as specified below:
Effluent Characteristics
Discharge Limitations
Monitoring
Requirements
Monthly
Lbs da Other Units
Avg. Weekly Avg. Monthly Avg.
(Specify)
Weekly Avg
Measurement
Sample
*Sample
Frequen
Type
Location
Flow
BOD, 5Day, 20 Degrees C
0.00240 MGD
Weekly
Instantaneous
I or E
Total Suspended Residue
30.0 mg/1
30.0 mg/l
45.0 mg/1
45.0
2/month
Grab
E
NH3 as N
mg/1
2/month
Grab
E
Fecal Coliform (geometric mean)
200.0/100 ml 400.0/100 ml
Monthly
2/month
Grab
Grab
E
Total Residual Chlorine
Temperature
1.9 mg/1
2.85 mg/1
Daily
Grab
E
gWeekly
Grab
E
* Sample locations: E - Effluent, I - Influent
The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units and shall be
monitored 2/month at the effluent by grab sample.
There shall be no discharge of floating solids or visible foam in other than trace amounts.
M3
n
m
2
bC-�
��l
� d3
r
n
"a
.moo
A. (_1_). EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS Final
NPDES No. NC0032131
During the
period beginning on
-the
the effective date of the expansion above 0.0024 MGD
and lasting until
expiration,
shall be limited
Permittee is authorized to discharge from outfall(s) serial number(s) 001.
Such disFharges_
and monitored by
the Permittee as specified below:
Effluent Characteristics
Discharge Limitations
Lbs da Other Units (Specify)
Monthly Avg. Weekly Avg Monthly Ayg• Weekly Avg.
Monitoring Requirements
Measurement Sample *Sample
Frequency Type Location
Flow
BOD, SDay, 20 Degrees C
0.070 MGD
Continuous
Recording
I or E
Total Suspended Residue
30.0 mg/l
45.0 mg/1
2/month
Composite
E
NH3 as N
30.0 mg/l
45.0 mg/l
2/month
Composite
E
Fecal Coliform (geometric mean)
200.0/100 ml
400.0/100 ml
Monthly
2/month
Composite
Grab
E
Total Residual Chlorine
Temperature
67.0 ug/l
100.5 ug/l
Daily
Grab
E
E
Total Nitrogen (NO2 + NO3 + TKN)
Weekly
Grab
E
Total Phosphorus
2/Year
Composite
E
2/Year
Composite
E
* Sample locations: E - Effluent, I - Influent
The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units and shall be
monitored 2/month at the effluent by grab sample.
There shall be no discharge of floating solids or visible foam in other than trace amounts.
M m
ZD C-3
# 'n
.t
.'i
Part III
Permit No. NCO032131
F. Toxicity Reopener.
This permit shall be modified, or revoked and reissued, to incorporate toxicity
limitations and monitoring requirements in the event toxicity testing or other
studies conducted on the effluent or receiving stream indicate that detrimental
effects may be expected in the receiving stream as a result of this discharge.
G. If this facility is built in phases, plans and specifications for the next
phase shall be submitted when the flow to the existing units reaches 80% of the
design capacity of the facilities on line. At no time may the flow tributary
to the facility exceed the design capacity of the existing units.
1091924%
OCT 24 1989 11
CENTRAL FILE COPY
.
GKEX08/MP
86/02/92
�
COMPLIANCE
EVALUATION
ANALYSIS
REPORT
PAGE i
PERMIT--NC8832i31
PIPE--081
REPORT
PERIOD:
9185-9284
LOC^--E
FACILITY--TWEET%IE
RAILROAD
DESIGN FLOW-~
'0788
CLASS--2
LOCATION --BLOWING
ROCK
REGION/COUNTY--04
WATAUGA
58858
8008
08538
8808
31616
58860
88018
88408
MONTH
Q/MGD
BOD
RE%/T%%
NH3+NH4-
FEC COLI
CHLORINE
TEMP
PH
LIMIT F
^8824 F
30,O0
F 38^0
NOL
F 280^O
F 1^908
NOL
9^8 6^8
91/85
.020F
^20
1^O
2^80
LE%%THAN
^OOO
14.88
6^8~6^7
LIMIT F
^8700 F
30^08
F 38^8
NOL
F 288^0
F 67088
NOL
9^8 6^8
91/06
^0812
15.98
8^8
8.58
LE%%THAN
^888
18^08
7^4-70
91/87
^8128
2^30
4^O
27^08
20^8
19.80
7^0-60
�
� 91/88
^028
18^20
3.5
1^28
LE%%THAN
^888
19^88
6^9~6"8
91/89
^8120
1"35
9^8
i^8O
85^8
^888
i8^88
6^9-6^8
91/18
^8128
5^30
9^8
15.08
48^8
1888
16^08
7^4-7^8
� 91/ii
�
^8228
4^58
2^8
LE%%THAN
45^8
^880
15"80
7"3~7^2
�
� 91/12
^8802
1.48
16.5
2^88
LE%%THAN
^008
9^08
7^4-7^2
92/Oi
92/82
92/83
^OdOO
ii^YO
LE%%TMAM
25^00
LE%%THAN
^800
8^68
7^4-6^8
AVERAGE
^068
5^89
6^6
Q.41
47^5
^008
15.17
MAXIMUM
,0688
i5^90
16.5
27^88
85^8
--------
19"08
7^400
MINIMUM
.0882
^28
LE%%THAN
LE%%THAN
LE%%THAN
^OOO
8.68
6^700
| UNIT
MGD
MG/L
MG/L
MG/L
4/188ML
U[/L
DEG.0
%U
� IGKEX@8/^MP -
O6/O2/92
COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2
^ PERMIT^-NCO832i31 PIPE--80i REPORT PERIOD: 9185-9284 LOC--^E
FACILITY-~TWEET%IE RAILROAD DESIGN FLOW-- '8788 CLASS--2
| LOCATION~ -BLOWING ROCK REGION/COUNTY~^84 WATAUGA
| 88688 08665
�
MONTH TOTAL N PHO%-TOT
LIMIT NOL NOL
� 91/86 9^808 3^9888
| 91/88 15^608 160588
91/11
i7^888
5^5500
� 9i/i2
�
92/Oi
92/O2
92/83
� AVERAGE
13^866
8^7933
� MAXIMUM
17^008
16^8500
MINIMUM
9~000
3.9880
| UNIT
MG/L
MG/L
,G9EXIS/MP- 06/02/92
COMPLIANCE EVALUATION ANALYSIS REPORT PAGE i
PERMIT---NC0032i3i PIPE---00i REPORT PERIOD: 9005-9f04 L-OC---E
FACILITY---TWEETSIE:: RAILROAD DESIGN FLOW--- .0700 CLASS--2
.LOCATION --BLOWING ROCK REGION/COUNTY----04 WATAUGA
50050 0000 00530 00610 31616 50060 00010 00400
MONTH Q/MGD BOD RE:.S/TES NH3+NH4- FE.0 COLI CHLORINE TEMP PH
LIMIT 1= .0024 F 30.00 F 30.0 NOL F 200.0 F 1.900 NOL. 9.0 6.0
90/05 .00is 16.70 13.0 & 00 LESSTHAN .000 16.00 & 1--6.1
90/06 .008 LESSTHAN 210 37.80 LESSTHAN .000 17.00 6.2-6. 1
90/07 .009 f42.50F 20.3 70.10 LESSTHAN .000 20.00 6.3-6.2
90/08 .0022 1 f 6.0t}F 28.1 57.50 LESSTHAN .000 18.00 6.4-6.2
90/09 .0019 171.50E 43.3E 74.f0 LESSTHAN .000 20.00 6.4-6.0
90/f0 .0015 24.00 21.0 4& 10 141.0 .000 14.00 6.4--6.2.
90/ 1 1 .0016 6.60 8.0 3.30 L.ES'STHAN .000 1 & 00 6.2-6. 2
1 90/ 1 2
91/01
91/02
91/03 .0000
91/04
AVERAGE
.005
79.55
22.1
42.70
141.0
.000 17,00
MAXIMUM
.0022
171.50
43.3
74.10
141.0
20.00 6.400
MINIMUM
.0000
LESSTHAN
& 0
3.30
LESSTHAN
.000 1& 00 6.000
UNIT
MGD
MG/L
MG/L.
MG/L
000ML..
MG/L DEG.0 EU
_
'GKEX88/MP
O6/82/92
,
'
COMPLIANCE
EVALUATION
ANALYSIS
REPORT
PAGE i
' PERMIT-~NC8832i3i
PIPE~-88i
REPORT
PERIOD: 8905-9884
LOC
--- E
FACILITY--TWEET%IE
RAILROAD
DESIGN FLOW--
.8788
CLASS-~2
LOCATION --BLOWING
ROCK
REGION/COUNTY`-84
WATAUGA
58858
80318
88538
88618
31616 58860
888iO
08480
MONTH
Q/MGD
BOD
RE%/T%%
NH3+NH4~
FEC COLI CHLORINE
TEMP
PH
LIMIT F
^8824
F 38^88
F 38.8
F 1088.0 F 1'980
9^8 6^0
89/O5
LIMIT F
^8024
F 38^88
F 38^8
NOL
F 1800^0 F 1'988
NOL
9"0 6^8
| 89/86
^0817
LE%%THAN
7^8
K70
^8 ^800
14^8O
6^4^6^2
1 89/87 ^0817 24^38 12^8
89/08 '8824 vvq)20^3
� 89/89 ^0822 4^58 6^8
8908 ^005 26~1
� LIMIT F ^0824 F 38^88 F 38^O
� 89/1i
8902 ^888O
� 90/01 .8888
98/82 ^8080
98/O3
98/84
ii^3O 158,0
.888 15^88 6^2-6'8
088 i5.88 6^2-6^8
3.80
28^8
^888
16^08
60~6^8
22.78
28^8
^800
13'88
6^2-6^O
NOL F
208.0
F
i^908
NOL
9.8 6^8
AVERAGE
^8011
3i^85
i4"4
ii^16
39^6
^880 14^68
MAXIMUM
^0024
49^88
26^1
22^78
i58^8 --------
~~--
16^00 ~---6400
MINIMUM
,0088
LE%%THAN
6^0
i,78
^O
^800 i3^8O 6.000
UNIT
MGD
MG/L
MG/L
MG/L
4088ML
MG/L DEG'C %U
RECEIVED
N.C. Dept. of EHNR
Facility Name:
NPDES No.:
Type of Waste:
Facility Status:
Permit Status:
Receiving Stream:
Stream Classification:
Subbasin:
County:
Regional Office:
Requestor:
Date of Request:
Topo Quad:
FACT SHEET FOR WASTELOAD ALLOCATION
Request # 6900
Tweetsie Railroad, Inc.
NC0032131
Domestic - 100%
Existing
Renewal
Middle Fork of the South Fork of the New River
WS-III Trout
050701
Watauga
Stream Characteristic:
Winston-Salem
USGS #
Kepler
Date:
5/l/92
Drainage Area (mi2):
C12Nw
Summer7Q10 (cfs):
Winter 7Q10 (cfs):
Average Flow (cfs):
30Q2 (cfs):
IWC (%):
J I I i - " ,192
Winston-Salem
Regiok,�,; �_)ttice
9.6
3.5
5.5
19
8.7
Wasteload Allocation Summary
(approach taken, correspondence with region, EPA, etc.)
Facility requesting renewal of existing NPDES permit. Technical Support recommends facility be
given the NH3 Choice Option of existing limits with a toxicity test or NH3 limit of 26 mg/l.
7h�5 [va5kMo' i5 aysomin� �aU.W y has 0M,,r(c(/�a o.o7rnr�cl P4/ � (r
Special Schedule Requirements and additional comments from Reviewers:
Recommended by;
Reviewed by
Instream Assessment:
Regional Supervisor:
Permits & Engineerin
7/8/92
RETURN TO TECHNICAL SERVICES BY:
AUG 1 1 1992
Z
W F e C7
-10
rn
O
0
Existing Limits:
Wasteflow (MGD):
BODS (mg/l):
NH3N (mg/1):
DO (mg/1):
TSS (mg/1):
Fecal Col. (/100 ml):
pH (SU):
Residual Chlorine (µg/1):
Oil & Grease (mg/1):
TP (mg/1):
TN (mg/1):
Wasteflow (MGD):
BODS (mg/1):
NH3N (mg/1):
DO (mg/1):
TSS (mg/1):
Fecal Col. (/100 ml):
pH (SU):
Residual Chlorine (µg/1):
Oil & Grease (mg/1):
TP (mg/1):
TN (mg/1):
Toxicity test (P/F):
CONVENTIONAL PARAMETERS
Monthly Average
Summer Winter
0.070
30
monitor
monitor
30
200
6-9
67
Existing Limits w/ Tox Test
Su Win
0.070
30
monitor
monitor
30
200
6-9
67
Chronic P/F @ 4.1 %
t"'�
NH3 Choice Limits
0.070
30
26
monitor
30
200
6-9
67
Limits Changes Due To: Parameters) Affected
Change in 7Q10 data
Change in stream classification
Relocation of discharge
Change in wasteflow
Other (onsite toxicity study, interaction, etc.)
Instream data
New regulations/standards/procedures
New facility information
_X_ Parameter(s) are water quality limited. For some parameters, the available load capacity of
the immediate receiving water will be consumed. This may affect future water quality based
effluent limitations for additional dischargers within this portion of the watershed.
Xj
No parameters are water quality limited, but this discharge may affect future allocations.
INSTREAM MONITORING REQUIREMENTS
Upstream Location:
Downstream Location:
Parameters:
Special instream monitoring locations or monitoring frequencies:
MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS
AAd ,quacy of Existing Treatment
Has the facility demonstrated the ability to meet the proposed new limits with existing treatment
facilities? Yes No
If no, which parameters cannot be met?
Would a "phasing in" of the new limits be appropriate? Yes No f-
If yes, please provide a schedule (and basis for that schedule) with the regional
office recommendations:
If no, why not?
�' s. w o � M-IM
Wasteload sent to EPA? (Major) _N_ (Y or N)
(If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old
assumptions that were made, and description of how it fits into basinwide plan)
Additional Information attached? (Y or N) If yes, explain with attachments.
w / /14Z.s - /71, ss
J
C.aw�L„e
6.070416v / xi-'Pm,d e-A,-A-0-4. a_ T-,,..u;— /,, a.- sC,� YSZ-ca�
Z�-
070 �lGD ' O P9�� Nf/3 ee..� '�SS
76 ova O°D,
t v /
/
�• 02s Al60
�Gcic �0.095- MCP # A5S5-
Co 3 5' It /.
I� _ o,o o A 1, 0•/ e,
�I �.07a� ls� f 3.ru o.lf' 3r 3,6
_ 4, /'/,
tweetsie railroad
AMMONIA ANALYSIS
7Q10: 3.5000 cfs
NH3 Effl. Conc: 74.0000 mg/l
AL (1/1.8 mg/1): 1000.00 ug/l
Upstream NH3 Conc.: 220.0000 ug/1
Design Flow: 0.0700 MGD
Predicted NH3 Downstream: 2438.41 ug/l
2.438409 mg/l
NH3 Limit: 26161.29 ug/l
26.16129 mg/1
AMMONIA ANALYSIS
7Q10: 5.5000 cfs
NH3 Effl. Conc: 74.0000 mg/l
AL (1/1.8 mg/1): 1800.00 ug/l
Upstream NH3 Conc.: 220.0000 ug/1
Design Flow: 0.0700 MGD
Predicted NH3 Downstream: 1647.32 ug/1
1.647321 mg/l
NH3 Limit: 81892.16 ug/l
81.89216 mg/1
(WINTER)
tweetsie railroad
CHLORINE
7Q10:
3.5000
CL2 Effl.
Conc:
0.0000
AL (17/19
ug/1):
17.0000
Upstream CL2
Conc.:
0.0000
Design
Flow:
0.0700
Predicted CL2 Downstream: 0.00
0
CL2 Limit: 565.3870
0.565387
ANALYSIS
cfs
mg/1
ug/1
ug/l
MGD
ug/l
mg/1
ug/l
mg/1