Loading...
HomeMy WebLinkAboutNC0025909_202201776_5-day Bypass Report_20221212North Carolina Department of Environment and Natural Resources Spill/Bypass Reporting Form (August 2014) WWTP Upset , Spill, or Bypass 5-Day Reporting Form (Please Print or Type Use Attachments if Needed) Permittee: ___Town of Rutherfordton______ Permit Number: ___NC 0025909______ Facility Name: _Town of Rutherfordton WWTP__________ County: _Rutherford____________ Incident Started: Date: ____12/05/2022_ Time: __14:00_______ Incident Ended: Date: ____12/05/2022_____ Time: __16:30_______ Level of Treatment: ___None _X_Primary Treatment _X_Secondary Treatment ___Chlorination/Disinfection Only Estimated Volume of Spill/Bypass: ___24,000_______________(must be given even if it is a rough estimate) Did the Spill/Bypass reach the Surface Waters? _X_Yes ___No If yes, please list the following: Volume Reaching Surface Waters: ___23,500__ Surface Water Name: __Cleghorn Creek___________ Did the Spill/Bypass result in a Fish Kill? ____Yes _X__No Was WWTP compliant with permit requirements? __X_Yes ____No Were samples taken during event? ____Yes __x_No (samples collected December 6, 2022) Source of the Upset/Spill/Bypass (L ocation or Treatment Unit): Clarifier scum pit and Chlorine contact chamber Cause or Reason for the Upset/Spill/Bypass: The wastewater flows from the secondary clarifier to the chlorine contact chamber. The cause of the bypass occurred from the inlet slide gate to the chlorine contact chamber being closed. Contractors were on-site painting the outside of the clarifiers and contact chamber. It is suspected that one of the painters knocked the clamp off that was holding up the inlet slide gate to the contact chamber preventing the flow into the chlorine contact chamber and through the effluent. The closed inlet slide gate caused the flow to backup into the clarifier and the scum pit and subsequently onto the grounds with flowed into Cleghorn Creek. North Carolina Department of Environment and Natural Resources Spill/Bypass Reporting Form (August 2014) Describe the Repairs Made or Actions Taken: Upon discovery and investigation of the bypass, the inlet slide gate was lifted back up to allow the flow to go into the chlorine contact chamber. As preventative action, a chain was put in place to hold the slide gate up to prevent problem from happing again . WWTP Upset , Spill, or Bypass 5-Day Reporting Form Page 2 Spill/Bypass Reporting Form (August 2014) Action Taken to Contain Spill, Clean Up and Remediate the Site (if applicable): N/A Action Taken or Proposed to be Taken to Prevent Occurrences: Put chain on slide gate to prevent gate from falling again Additional Comments About the Event: 24-Hour Report Made To: Division of Water Resources __X_ Emergency Management ____ Contact Name: Lauren Armeni Date: 12/06/2022 Time: 8:10am Other Agencies Notified (Health Dept, etc): _______________________________ Person Reporting Event: ____Phillip Reynolds______Phone Number: ____828-289-8505________ Did DWR Request an Additional Written Report? ___Yes _X_No If Yes, What Additional Information is Needed: ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ WWTP Upset , Spill, or Bypass 5-Day Reporting Form Spill/Bypass Reporting Form (August 2014) Sample Results Collection Date: December 6, 2022 Location: Site 1 – Upstream of entry point Site 2 – Entry point Site 3 – Downstream of entry point Analyzing Laboratory: Rutherfordton WWTP and Water Quality Lab & Operation , Inc Location pH, SU D.O., mg/l Temp, C Fecal Coliform, CFU/100 mls Site 1 7.12 10.4 10 106 Site 2 102 Site 3 7.02 10.3 10 69 WWTP Upset , Spill, or Bypass 5-Day Reporting Form Spill/Bypass Reporting Form (August 2014) RUTHERFORDTON WWTP BYPASS LOCATION Scum Pit (Overflow location) Pathway and Entry point WWTP Upset , Spill, or Bypass 5-Day Reporting Form Spill/Bypass Reporting Form (August 2014) RUTHERFORDTON WWTP SLIDE GATE TO CHLORINE CONTACT CHAMBER Newly Added Chain Clamps