Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW4221201_Design Calculations_20221207
STORMWATER & EROSION CONTROL CALCULATIONS Zem SALEM BROOKE SUBDIVISION FORSYTH COUNTY, NORTH CAROLINA PREPARED BY: LATHAM-WALTERS ENGINEERING, INC. 16507-A NORTHCROSS DRIVE HUNTERSVILLE, N.C. 28078 Phone: 704-895-8484 Fax: 704-237-4362 N.C. Corporate License C-1815 FOR BRAXTON REAL ESTATE & DEVELOPMENT COMPANY, LLC 6420 HAMPTON KNOLL ROAD CLEMMONS, N.C. 27012 DATE: NOVEMBER 22, 2022 ,• ,� CA t � Doe G 5 ro SEAL o 0 18584 0 o N AC IN r/ DOnO.DD \ Dschedule (25 YR.) Page 1 Line Inlet Gnd/Rim Drng Total Runoff i i Flow Invert Invert Capac Line Line Line Vol Line Depth Depth Cover No. ID El Up Area Area Coeff Inlet Sys Rate Up Dn Full Size Length Slope Dn ID Dn Up Up (ft) (ac) (ac) (C) (in/hr) (in/hr) (cfs) (ft) (ft) (cfs) (in) (ft) M (ft/s) (ft) (ft) (ft) 1 DI 1 811.50 2.39 2.39 0.60 7.59 7.59 10.89 807.00 806.00 12.70 18 68.360 1.46 6.87 DI 1-FES 2 1.26 1.26** 3.00 2 DI 9 807.00 5.98 5.98 0.60 5.31 5.31 19.05 803.00 802.20 26.80 24 56.979 1.40 7.20 DI 9-FES 10 1.57 1.57** 2.00 3 DI 6 806.50 1.86 1.86 0.60 7.59 7.59 8.47 801.75 801.00 10.70 18 72.300 1.04 5.93 DI 6-FES 7 1.13 1.13** 3.25 4 SDMH 4 809.11 0.01 9.69 0.60 7.59 4.64 26.97 799.00 797.80 45.48 30 97.560 1.23 7.26 SDMH4-FES 5 1.77 1.77** 7.61 5 HW 3 806.29 9.68 9.68 0.60 4.66 4.66 27.08 803.00 799.20 79.18 30 101.940 3.73 8.35 HW3-SDMH4 1.57 1.77** 0.79 Project File: Storm Drainage.stm Number of lines: 5 Date: 11/22/2022 NOTES: Intensity = 61.15 / (Inlet time + 11.30) 10.75 --Return period = 25 Yrs. ; ** Critical depth Storm Sewers Salem Brooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 1 2. Determine Runoff for 10-Year Storm Q = CIA 19.8 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 11160 cf 4. Size Basin: INPUT Basin No. 1 Drainage Area 9.5 Disturbed Area 6.2 C 0.45 Time of Concentration 15 Intensity 4.62 Weir Depth 1.0 Weir Length 10 Storage: Area Vol. Cum Vol 796 5209 0 0 798 6476 11685 11685 800 7844 14320 26005 Surface Area = (Q10 x325) = 6418.91 S.F. 6476.00 S.F. @ EL Length = 2 x Width Width 56.7 Feet USE W = 55 Length 113.3 Feet USE L = 120 Depth 1.74 Feet USE D = 2.0 Actual Volume = 11685.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 1.0 FEET Depth to Top of Embankment 6.0 FEET 2:1 Side Slopes 5' Top Width 798 TOP 800 WEIR 798 BOTTOM 796 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 19.8 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 2.00 " Diameter Skimmer Orifice Size= 2.00 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.16667 ft Qo= 0.04286 cfs 3703.3901 cf/day Volume: 11160 cf Drawdown time= 72.32 Hrs 3.01345519 (48-120 hours Required) Drawdown per 0.01 feet Salem Brooke Subdivision Forsyth County, NC Erosion Control Skimmer Sediment Basin NCDWQ (or SCDHEC) 1. Basin No. 2 2. Determine Runoff for 10-Year Storm Q = CIA 8.5 C.F.S. 3. Determine Storage Capacity Required: 1800 CF/AC x Disturbed Area = Storage Volume Storage Volume = 1872 cf 4. Size Basin: Surface Area = (Q10 x325) = 2766.52 S.F. Length = 2 x Width Width 37.2 Feet USE W = Length 74.4 Feet USE L = Depth 0.68 Feet USE D = INPUT Basin No. 2 Drainage Area 2.62 Disturbed Area 1.04 C 0.45 Time of Concentration 5 Intensity 7.22 Weir Depth 1.0 Weir Length 10 Storage: Area Vol. Cum Vol 800 2249 0 0 802 3076 5325 5325 804 4004 7080 12405 3076.00 S.F. @ EL Actual Volume = 5325.00 Cubic Feet (from the plans) 5. Embankment Depth to Weir 1.0 FEET Depth to Top of Embankment 4.0 FEET 2:1 Side Slopes 5' Top Width 40 80 2.0 802 TOP 804 WEIR 802 BOTTOM 800 6. Design Spillway for Q10 utilizing the Weir Equation with P of Freeboard. Q = 3.0(Q(H^1.5) wY L = Length of Weir 10 feet H = Depth of Weir = 1 feet Qcapacity 30.0 cfs Q 10 = 8.5 cfs < Qcapacity - OK 9. Basin Dewateri ng/ Skimmer Sizing: Q=cA(2gH)^1/2 Skimmer Device Size= 1.00 " Diameter Skimmer Orifice Size= 1.00 " (This may be reduced if required) Amount of Skimmers= 1 Head on Orifice= 0.08333 ft Qo= 0.00758 cfs 654.67306 cf/day Volume: 1872 cf Drawdown time= 68.63 Hrs 2.85944256 (48-120 hours Required) Drawdown per 0.01 feet TR 55 Urban Hydrology for Small Watershe LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Salem Brook Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Skimmer Basin 1 Prop. Tc for Existing Drainage Area Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nL)^0.8))/((P2)^0.5 x s^0.4) 0.24 n Manning's Coefficient for pavement 100 L Flow Length Travel (100' max. urban, 300' max rural) 3.12 P2 (0.16 in/hr x 24 hours from NCDENR for Charlotte) 0.03 s Slope of hydraulic grade line 0.220 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345's^0.5) Unpaved V2 = (20.3282's^0.5) Paved 0 Length of Paved Flow 695 Length of Unpaved Flow 2.61 % Slope of Paved Flow 7.19% Slope of Unpaved Flow 4.328 V2 -Unpaved (fps) 3.284 V2 - Paved (fps) 0.000 T2 Paved (seconds) 160.597 T2 Unpaved (seconds) 0.045 T2 Total (hours) 3. Pipe Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 18 d - diameter of pipe, in. 0.375 r - hydraulic radius, I; AreaM/etted Perimeter 2.280 s - slope of hydraulic grade line, (ft/ft) 0.013 n - Manning's roughness coefficient 89.995 V - velocity in fps 1 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 4. Open Channel Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 0.65 r - hydraulic radius, I; AreaM/etted Perimeter 0.0151 s - slope of hydraulic grade line, (ft/ft) 0.045 n - Manning's roughness coefficient 3.053033 V - velocity in fps 0 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 0.265 Tc = T1 + T2 + T3 + T4 (hrs.) 15.89 Total Tc (minutes) Use 16 Minute Tc TR 55 Urban Hydrology for Small Watershe LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Salem Brook Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Drop Inlet 9 Prop. Tc for Existing Drainage Area Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nL)^0.8))/((P2)^0.5 x s^0.4) 0.24 n Manning's Coefficient for pavement 100 L Flow Length Travel (100' max. urban, 300' max rural) 3.12 P2 (0.16 in/hr x 24 hours from NCDENR for Charlotte) 0.03 s Slope of hydraulic grade line 0.220 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345's^0.5) Unpaved V2 = (20.3282's^0.5) Paved 0 Length of Paved Flow 441 Length of Unpaved Flow 2.61 % Slope of Paved Flow 6.35% Slope of Unpaved Flow 4.066 V2 -Unpaved (fps) 3.284 V2 - Paved (fps) 0.000 T2 Paved (seconds) 108.473 T2 Unpaved (seconds) 0.030 T2 Total (hours) 3. Pipe Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 18 d - diameter of pipe, in. 0.375 r - hydraulic radius, I; AreaM/etted Perimeter 0.027 s - slope of hydraulic grade line, (ft/ft) 0.013 n - Manning's roughness coefficient 9.727 V - velocity in fps 0 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 4. Open Channel Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 0.65 r - hydraulic radius, I; AreaM/etted Perimeter 0.0151 s - slope of hydraulic grade line, (ft/ft) 0.03 n - Manning's roughness coefficient 4.57955 V - velocity in fps 413 Length of Flow (ft.) 0.025 T3 (hrs.) Length/Velocity/3600 0.275 Tc = T1 + T2 + T3 + T4 (hrs.) 16.53 Total Tc (minutes) Use 16 Minute Tc TR 55 Urban Hydrology for Small Watershe LATHAM-WALTERS ENGINEERING, INC. Time of Concentration & Travel Time 16507-A Northcross Drive Salem Brook Subdivision Huntersville, NC 28078 Forsyth County, NC (704) 895-8484 Headwall 3 Prop. Tc for Existing Drainage Area Tc = T1 + T2 + T3 Time of Concentration 1. Sheet Flow: T1 = (0.007 x (nL)^0.8))/((P2)^0.5 x s^0.4) 0.24 n Manning's Coefficient for pavement 100 L Flow Length Travel (100' max. urban, 300' max rural) 3.12 P2 (0.16 in/hr x 24 hours from NCDENR for Charlotte) 0.01 s Slope of hydraulic grade line 0.367 T1 Travel Time (hr.) 2. Shallow Concentrated Flow V2 = (16.1345's^0.5) Unpaved V2 = (20.3282's^0.5) Paved 0 Length of Paved Flow 548 Length of Unpaved Flow 2.61 % Slope of Paved Flow 5.62% Slope of Unpaved Flow 3.825 V2 -Unpaved (fps) 3.284 V2 - Paved (fps) 0.000 T2 Paved (seconds) 143.265 T2 Unpaved (seconds) 0.040 T2 Total (hours) 3. Pipe Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 18 d - diameter of pipe, in. 0.375 r - hydraulic radius, I; AreaM/etted Perimeter 2.280 s - slope of hydraulic grade line, (ft/ft) 0.013 n - Manning's roughness coefficient 89.995 V - velocity in fps 1 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 4. Open Channel Flow V = (1.49 x (r)^0.67 x (s)^0.5)/n Velocity from Manning's Equation (fps) 0.65 r - hydraulic radius, I; AreaM/etted Perimeter 0.0151 s - slope of hydraulic grade line, (ft/ft) 0.045 n - Manning's roughness coefficient 3.053033 V - velocity in fps 0 Length of Flow (ft.) 0.000 T3 (hrs.) Length/Velocity/3600 0.406 Tc = T1 + T2 + T3 + T4 (hrs.) 24.38 Total Tc (minutes) Use 20 Minute Tc Salem Place Subdivision Culvert Calculations Date: 9/21/2022 Project #: 2022.25 CAPACITY CHECK FOR NCDOT DROP INLETS PACITY CHECK FOR NCDOT STD. 840.05 OPEN THROAT INLET OPENING HEIGHT 0.5 FT. NUMBER OF OPENINGS 4 WIDTH OPENING 4.33 FT. REA OF OPENING = 8.66 SF JTAL LENGTH = 17.32 FT /EIR EQUATION: Q= CLH^3/2 (C=3.1) RIFICE EQUATION: Q= CA(2GH)^1/2 (C=0.60) DEPTH (FEET) Q weir 0.5 18.98 cfs 1 53.69 1.5 98.64 HW/d for max flow of 18.37 cfs = 0.50' Q orifice 29.48 41.70 51.07 Culvert Report Hydraflow Express Extension for Autodesk0 AutoCADO Civil 3D0 by Autodesk, Inc. Headwall 3 Invert Elev Dn (ft) = 799.20 Calculations Pipe Length (ft) = 101.00 Qmin (cfs) Slope (%) = 3.76 Qmax (cfs) Invert Elev Up (ft) = 803.00 Tailwater Elev (ft) Rise (in) = 30.0 Shape = Circular Highlighted Span (in) = 30.0 Qtotal (cfs) No. Barrels = 1 Qpipe (cfs) n-Value = 0.012 Qovertop (cfs) Culvert Type = Circular Concrete Veloc Dn (ft/s) Culvert Entrance = Square edge w/headwall (C) Veloc Up (ft/s) Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 HGL Dn (ft) HGL Up (ft) Embankment Hw Elev (ft) Top Elevation (ft) = 810.00 Hw/D (ft) Top Width (ft) = 2.00 Flow Regime Crest Width (ft) = 100.00 El-(ft) 811.00 809.DD 907.D0 305.00 303.00 301.00 799.00 797.00 0 Headwall 3 1c 20 30 40 50 60 70 30 90 100 110 120 130 140 Circular Culvert HGL Embank Wednesday, Sep 14 2022 = 24.54 = 24.54 = (dc+D)/2 = 24.54 = 24.54 = 0.00 = 5.59 = 6.97 = 801.29 = 804.69 = 805.64 = 1.06 = Inlet Control H. Depth jt) 3.00 6.00 4.00 2.00 0.00 2.00 -4.00 -6.00 150 Reach (R) VEGETATED CONVEYANCE DITCH CALCULATIONS 10 YEAR STORM Channel Bottom Drain Runoff i10 Q10 Mannings Slope Ditch Normal Velocity Ditch Liner ID Width Area Coeff © (Ditch) ft/ft Length Depth & Final Grass FT. AC. in/hr CFS FT. FT. FPS VCD 1 2 0.79 0.45 6.89 2.45 0.0690 0.0182 264 0.50 1.41 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 2 2 0.39 0.45 6.89 1.21 0.0760 0.0182 200 0.36 1.08 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 3 2 1.20 0.50 6.89 4.13 0.0510 0.0408 407 0.45 2.70 NAG S150 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 4 2 1.42 0.50 6.89 4.89 0.0530 0.0339 229 0.53 2.60 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 5 2 0.40 0.50 6.89 1.38 0.0570 0.0500 195 0.25 1.96 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 6 2 0.50 0.50 6.89 1.72 0.0690 0.0216 238 0.40 1.36 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 7 2 1.59 0.50 6.89 5.48 0.0470 0.0488 148 0.48 3.32 NAG S150 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD8 2 0.61 0.50 6.89 2.10 0.0610 0.0314 89 0.37 1.80 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 9 2 0.29 0.50 6.89 1.00 0.0700 0.0282 133 0.28 1.26 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 10 2 4.38 0.50 5.07 11.10 0.0640 0.0112 149 1.11 1.86 NAG S150 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 11 2 5.32 0.50 5.07 13.49 0.0410 0.0516 142 0.69 4.80 NAG SC150 STAPLE PATTERN D MIX (SOD & BUNCH) VCD 12 2 0.67 0.50 6.89 2.31 0.0760 0.0216 221 0.45 1.52 NAG S75 STAPLE PATTERN "D" MIX (SOD & BUNCH) VCD 13 2 4.64 0.50 4.65 10.79 0.0440 0.0427 413 0.67 3.97 NAG S150 STAPLE PATTERN "D" MIX (SOD & BUNCH) NOTE: VCD 10 & VCD 11 ARE BY-PASS DITCHES IMPROVED TO CARRY OFF -SITE RUNOFF THROUGH THE PROJECT. 10/12/22, 12:38 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS »>VCD1 Name VCD 1 Discharge 2.45 Channel Slope 0.0182 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S75 Unvegetated Straight 2.45 cfs 2.28 ft/s 0.35 ft 0.035 1.6 Ibs/ft2 0.4 Ibs/ft2 4 STABLE D Underlying Straight 2.45 cfs 2.28 ft/s 0.35 ft 0.035 1.74 Ibs/ft2 0.29 Ibs/ft2 6.03 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 2.45 cfs 1.41 ft/s 0.5 ft 0.069 4 Ibs/ft2 0.56 Ibs/ft2 7.09 STABLE -- Vegetation Underlying Straight 2.45 cfs 1.41 ft/s 0.5 ft 0.069 4 Ibs/ft2 0.38 Ibs/ft2 10.44 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232699/show 1 /1 10/12/22, 12:44 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD2A Name VCD 2 Discharge 1.21 Channel Slope 0.0182 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S75 Unvegetated Straight 1.21 cfs 1.8 ft/s 0.25 ft 0.037 1.6 Ibs/ft2 0.28 Ibs/ft2 5.73 STABLE D Underlying Straight 1.21 cfs 1.8 ft/s 0.25 ft 0.037 1.74 Ibs/ft2 0.21 Ibs/ft2 8.11 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 1.21 cfs 1.08 ft/s 0.36 ft 0.076 4 Ibs/ft2 0.41 Ibs/ft2 9.69 STABLE -- Vegetation Underlying Straight 1.21 cfs 1.08 ft/s 0.36 ft 0.076 4 Ibs/ft2 0.3 Ibs/ft2 13.48 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232701 /show 1 /1 10/12/22, 12:49 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD3 Name VCD 3 Discharge 4.13 Channel Slope 0.0408 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S150 Straight 4.13 cfs 3.31 ft/s 0.39 ft 0.039 1.8 Ibs/ft2 1 Ibs/ft2 1.8 STABLE D Unvegetated Underlying Straight 4.13 cfs 3.31 ft/s 0.39 ft 0.039 1.96 Ibs/ft2 0.71 Ibs/ft2 2.77 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 4.13 cfs 2.7 ft/s 0.45 ft 0.051 4 Ibs/ft2 1.16 Ibs/ft2 3.46 STABLE -- Vegetation Underlying Straight 4.13 cfs 2.7 ft/s 0.45 ft 0.051 4 Ibs/ft2 0.8 Ibs/ft2 5.01 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232704/show 1 /1 10/12/22, 12:51 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD4 Name VCD 4 Discharge 4.89 Channel Slope 0.0339 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S75 Unvegetated Straight 4.89 cfs 3.72 ft/s 0.41 ft 0.032 1.6 Ibs/ft2 0.86 Ibs/ft2 1.85 STABLE D Underlying Straight 4.89 cfs 3.72 ft/s 0.41 ft 0.032 1.74 Ibs/ft2 0.61 Ibs/ft2 2.87 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 4.89 cfs 2.6 ft/s 0.53 ft 0.053 4 Ibs/ft2 1.11 Ibs/ft2 3.59 STABLE -- Vegetation Underlying Straight 4.89 cfs 2.6 ft/s 0.53 ft 0.053 4 Ibs/ft2 0.75 Ibs/ft2 5.35 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232705/show 1 /1 10/12/22, 12:54 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD5 Name VCD 5 Discharge 1.38 Channel Slope 0.05 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S75 Unvegetated Straight 1.38 cfs 2.85 ft/s 0.19 ft 0.033 1.6 Ibs/ft2 0.59 Ibs/ft2 2.72 STABLE D Underlying Straight 1.38 cfs 2.85 ft/s 0.19 ft 0.033 1.74 Ibs/ft2 0.47 Ibs/ft2 3.69 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 1.38 cfs 1.96 ft/s 0.25 ft 0.057 4 Ibs/ft2 0.8 Ibs/ft2 5.03 STABLE -- Vegetation Underlying Straight 1.38 cfs 1.96 ft/s 0.25 ft 0.057 4 Ibs/ft2 0.61 Ibs/ft2 6.57 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232706/show 1 /1 10/12/22, 12:55 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD6 Name VCD 6 Discharge 1.72 Channel Slope 0.0216 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S75 Unvegetated Straight 1.72 cfs 2.17 ft/s 0.28 ft 0.035 1.6 Ibs/ft2 0.37 Ibs/ft2 4.27 STABLE D Underlying Straight 1.72 cfs 2.17 ft/s 0.28 ft 0.035 1.74 Ibs/ft2 0.28 Ibs/ft2 6.17 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 1.72 cfs 1.36 ft/s 0.4 ft 0.069 4 Ibs/ft2 0.54 Ibs/ft2 7.47 STABLE -- Vegetation Underlying Straight 1.72 cfs 1.36 ft/s 0.4 ft 0.069 4 Ibs/ft2 0.38 Ibs/ft2 10.56 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232707/show 1 /1 10/12/22, 1:46 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD7 Name VCD 7 Discharge 5.48 Channel Slope 0.0488 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S150 Straight 5.48 cfs 4.01 ft/s 0.42 ft 0.036 1.8 Ibs/ft2 1.27 Ibs/ft2 1.41 STABLE D Unvegetated Underlying Straight 5.48 cfs 4.01 ft/s 0.42 ft 0.036 1.96 Ibs/ft2 0.89 Ibs/ft2 2.2 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 5.48 cfs 3.32 ft/s 0.48 ft 0.047 4 Ibs/ft2 1.46 Ibs/ft2 2.74 STABLE -- Vegetation Underlying Straight 5.48 cfs 3.32 ft/s 0.48 ft 0.047 4 Ibs/ft2 1 Ibs/ft2 4.01 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232708/show 1 /1 10/12/22, 2:43 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD8 Name VCD 8 Discharge 2.1 Channel Slope 0.0314 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S75 Unvegetated Straight 2.1 cfs 2.72 ft/s 0.27 ft 0.034 1.6 Ibs/ft2 0.54 Ibs/ft2 2.99 STABLE D Underlying Straight 2.1 cfs 2.72 ft/s 0.27 ft 0.034 1.74 Ibs/ft2 0.41 Ibs/ft2 4.3 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 2.1 cfs 1.8 ft/s 0.37 ft 0.061 4 Ibs/ft2 0.73 Ibs/ft2 5.47 STABLE -- Vegetation Underlying Straight 2.1 cfs 1.8 ft/s 0.37 ft 0.061 4 Ibs/ft2 0.52 Ibs/ft2 7.65 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232710/show 1 /1 10/12/22, 2:43 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>>VCD9 Name VCD 9 Discharge 1 Channel Slope 0.0282 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S75 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern S75 Unvegetated Straight 1 cfs 2.01 ft/s 0.19 ft 0.036 1.6 Ibs/ft2 0.34 Ibs/ft2 4.73 STABLE D Underlying Straight 1 cfs 2.01 ft/s 0.19 ft 0.036 1.74 Ibs/ft2 0.27 Ibs/ft2 6.43 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 1 cfs 1.26 ft/s 0.28 ft 0.07 4 Ibs/ft2 0.49 Ibs/ft2 8.16 STABLE Vegetation Underlying Straight 1 cfs 1.26 ft/s 0.28 ft 0.07 4 Ibs/ft2 0.37 Ibs/ft2 10.82 STABLE Substrate hftps://ecmds.com/project/153992/channel-analysis/232714/show 1 /1 10/12/22, 2:46 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>> VCD 10 Name VCD 10 Discharge 11.1 Channel Slope 0.0112 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 11.1 cfs 2.4 ft/s 0.95 ft 0.045 1.8 Ibs/ft2 0.66 Ibs/ft2 2.71 STABLE D Unvegetated Underlying Straight 11.1 cfs 2.4 ft/s 0.95 ft 0.045 1.96 Ibs/ft2 0.4 Ibs/ft2 4.87 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 11.1 cfs 1.86 ft/s 1.11 ft 0.064 4 Ibs/ft2 0.78 Ibs/ft2 5.13 STABLE Vegetation Underlying Straight 11.1 cfs 1.86 ft/s 1.11 ft 0.064 4 Ibs/ft2 0.46 Ibs/ft2 8.69 STABLE Substrate hftps://ecmds.com/project/153992/channel-analysis/232715/show 1 /1 10/12/22, 2:52 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>> VCD 11 Name VCD 11 Discharge 13.49 Channel Slope 0.0516 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) SC150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC150 Straight 13.49 cfs 5.67 ft/s 0.62 ft 0.033 2 Ibs/ft2 1.99 Ibs/ft2 1.01 STABLE D Unvegetated Underlying Straight 13.49 cfs 5.67 ft/s 0.62 ft 0.033 2.18 Ibs/ft2 1.3 Ibs/ft2 1.68 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 13.49 cfs 4.8 ft/s 0.69 ft 0.041 4 Ibs/ft2 2.22 Ibs/ft2 1.8 STABLE Vegetation Underlying Straight 13.49 cfs 4.8 ft/s 0.69 ft 0.041 3.11 Ibs/ft2 1.42 Ibs/ft2 2.19 STABLE Substrate hftps://ecmds.com/project/153992/channel-analysis/232716/show 1 /1 10/12/22, 1:53 PM NORTH AMERICAN GREEN CHANNEL ANALYSIS »>VCD 12 Name VCD12 Discharge 10.79 Channel Slope 0.0427 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern S150 Straight 10.79 cfs 4.75 ft/s 0.6 ft 0.035 1.8 Ibs/ft2 1.59 Ibs/ft2 1.13 STABLE D Unvegetated Underlying Straight 10.79 cfs 4.75 ft/s 0.6 ft 0.035 1.96 Ibs/ft2 1.04 Ibs/ft2 1.88 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress I Factor Pattern lnreinforced Straight 10.79 cfs 3.97 ft/s 0.67 ft 0.044 4 Ibs/ft2 1.8 Ibs/ft2 2.22 STABLE -- Vegetation Underlying Straight 10.79 cfs 3.97 ft/s 0.67 ft 0.044 3.67 Ibs/ft2 1.1S Ibs/ft2 3.18 STABLE -- Substrate https://ecmds.com/project/153992/channel-analysis/232703/show 1 /1 10/24/22, 9:31 AM NORTH AMERICAN GREEN CHANNEL ANALYSIS >>> VCD 13 Name VCD 13 Discharge 10.79 Channel Slope 0.0427 Channel Bottom Width 2 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam (CL) S150 ECMDS 7.0 North American Green 5401 St. Wendel -Cynthia na Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern 5150 Straight 10.79 cfs 4.75 ft/s 0.6 ft 0.035 1.8 Ibs/ft2 1.59 Ibs/ft2 1.13 STABLE D Unvegetated Underlying Straight 10.79 cfs 4.75 ft/s 0.6 ft 0.035 1.96 Ibs/ft2 1.04 Ibs/ft2 1.88 STABLE D Substrate Unreinforced Vegetation Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern Inreinforced Straight 10.79 cfs 3.97 ft/s 0.67 ft 0.044 4 Ibs/ft2 1.8 Ibs/ft2 2.22 STABLE Vegetation Underlying Straight 10.79 cfs 3.97 ft/s 0.67 ft 0.044 3.67 Ibs/ft2 1.15 Ibs/ft2 3.18 STABLE Substrate hftps://ecmds.com/project/153992/channel-analysis/232703/show 1 /1