Loading...
HomeMy WebLinkAboutSW4221201_Supplement-EZ Form_20221207SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 lProjectNarne Salem Brooke Subdivision 2 Project Area ac 13.55 ---_ 3 Coastal Wetland Area {ac 0 4 Surface Water Area ac 0.04 5 Is this project High or Low Density? Low 8 Does [his project use an off site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003(D o:q? _ _ NIA to Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 infiltration System 12 Biaretentiort Coll 13 Wet Pond 14 Stormwater Wetland — 15 Permeable Pavement 16 Sand Fitter 17 Rainwater Harvesting RWH r 18 Green Roof 19 Level Spreader -Filter 20 Disconnected Im arvious Surface DIS 21 Treatment Swale 22 PR Pond 23 J Storm Filter 24 ISilva Cell 25 1Bayfilter _ — 26 iRlterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and TiLe: James L. Walters, P.E.__ 28 Or anlzation: _ Latham -Walters En ineerin , Inc. 29 Street address: 16507-A NoAhcross Drive 30 Citty, State, Zi Huntersville, NC 28078 31 Phone numbers : 704-807-4134 32 _ Email: jlmriillwengineer.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. 10 � W SEAL 18584 r e s'+'fif11fs ��t�� �r Signature of Designer Data // 212 - 201? z DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM N/A N/A 5 Total drainage area (sq ft) 1,089,321 1,089,321 6 Onsite drainage area (sq ft) 575,806 575,806 7 Offsite drainage area (sq ft) 513,515 513,515 8 Total BUA in project (sq ft) 185679 sf 185679 sf 9 New BUA on subdivided lots (subject to permitting) (sq ft) 67600 sf 67600 sf 10 New BUA not on subdivided lots (subject to permitting) (so 33327 sf 33327 sf 11 Offsite BUA (sq ft) 61352 sf 61352 sf 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft) sf sf Sidewalk (sq ft) sf sf Roof (sq ft) sf sf Roadway (sq ft) 33327 sf 33327 sf Future (sq ft) sf sf Other, please specify in the comment box below (sq ft) sf sf 13 New infiltrating permeable pavement on subdivided lots (sq ft) sf sf 14 New infiltrating permeable pavement not on subdivided lots (sq ft) sf sf 15 Existing BUA that will remain (not subject to permitting) (sq ft) sf sf 16 Existing BUA that is already permitted (sq ft) sf sf 17 Existing BUA that will be removed (sq ft) sf sf 18 Percent BUA 17% 17% 19 Design storm (inches) N/A N/A 20 Design volume of SCM (cu ft) N/A N/A 21 Calculation method for design volume N/A N/A DDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): 26 Lot single family subdivision LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 am 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 3 sf 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 5.67 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) na 8 Bottom width of curb outlet swale(s) (feet) na 9 Maximum side slope of curb outlet swale(s) (H:V) na 10 Minimum length of curb outlet swale(s) (feet) na 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: Line 4 does not format properly. Maximum side slo e is 3:1 Swale # Drainage Area ac BUA (ac) Pervious area ac C Q (cfs) Slope N Va„ - (fps) V.-.1 (fps) Flow depth (ft) 1 0.79 0.09 0.70 0.45 2.45 1.82 5.00 1.41 0.50 2 0.39 0.06 0.33 0.45 1.21 1.82 5.00 1.08 0.36 3 1.20 0.61 0.59 0.45 4.13 4.08 5.00 2.70 0.45 4 1.42 0.41 1.01 0.45 4.89 3.39 5.00 2.60 0.53 5 0.40 0.14 0.26 0.45 1.38 5.00 5.00 1.96 0.25 6 0.50 0.23 0.27 0.45 1.72 2.16 5.00 1.36 0.40 7 1.59 0.59 1.00 0.45 5.48 4.88 5.00 3.32 0.48 8 0.61 0.25 0.36 0.45 2.10 3.14 5.00 1.80 0.37 9 0.29 0.13 0.16 0.45 1.00 2.82 5.00 1.26 0.28 10 4.38 0.65 3.73 0.45 11.10 1.12 5.00 1.86 1.11 11 5.32 0.09 5.23 0.45 13.49 5.16 5.00 4.80 0.69 12 0.67 0.36 0.31 0.45 2.31 2.16 5.00 1.52 0.45 13 4.64 0.50 4.14 0.45 10.79 4.27 5.00 3.97 0.67 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30