Loading...
HomeMy WebLinkAboutNCG081033_Application_20221208RECEIVED FOR AGENCY U E ONLY DEC 0 8 1011 NCG08 I Q_3 Assigned to: t v C) \� DEMLR-Stormwater Program ARID FRO MRO RO WARD WIRO WSRO Division of Energy, Mineral, and Land Resources Land Quality Section National Pollutant Discharge Elimination System NCGO80000 Notice of Intent This General Permit covers STORMWATER DISCHARGES associated with activities under the following Standard Industrial Classifications: SIC 40 [Railroad Transportation], SIC 41 [Local and Suburban Transit and Interurban Highway Passenger Transportation], SIC 42 [Motor Freight Transportation and Warehousing — except for SIC 4221-4225], SIC 43 [United States Postal Services], SIC 5171 [Petroleum Bulk Stations and Terminals — when total petroleum site storage capacity is less than 1 million gallons]. The following activities are also included: other industrial actives where the vehicle maintenance area(s) are the only area requiring permitting; stormwater discharges from oil water separators and/or from secondary containment structures associated with petroleum storage facilities with less than 1 million gallons of total petroleum site storage capacity. You can find information on the DEMLR Stormwater Program at deq.nc.gov/SW Directions: Print or type all entries on this application. Send the original, signed application with all required items listed in Item (6) below to: NCDEMLR Stormwater Program, 1612 MSC, Raleigh, INC 27699-1612. The submission of this application does not guarantee coverage under the General Permit. Prior to coverage under this General Permit a site inspection will be conducted. 1. Owner/Operator (to whom all permit correspondence will be mailed): Name of legal organizational entity: Legally responsible person as signed in Item (7) below: BRAVEN ENVIRONMENTAL, LLC MR. JEFF NEUMANN Street address: City: State: Zip Code: 517 N. INDUSTRIAL DR. ZEBULON NC 27591 Telephone number: Email address: 917-658-9330 jneumann@bravenenvironmental.com Type of Ownership: Government ❑County ❑Federal ❑Municipal ❑State Non -government ❑+ Business (If ownership is business, a copy of NCSOS report must be included with this application) ❑Individual 2. Industrial Facility (facility being permitted): Facility name: Facility environmental contact: BRAVEN ENVIRONMENTAL, LLC MR. CHRISTOPHER R. SERRATI Street address: City: State: Zip Code: 517 N. INDUSTRIAL DR. ZEBULON NC 27591 Parcel Identification Number (PIN): County: 2705574023 WAKE Telephone number: Email address: 501-628 4793 cserrati@bravenenvironmental.com 4-digit SIC code: Facility is: Date operation is to begin or began: 2869 [:]New ❑ Proposed ❑ Existing 2019 Latitude of entrance: Longitude of entrance: 35"49'40.99" N 78"18'22.94" W Page 1 of 5 Brief description of the types of industrial activities and products manufactured at this facility: PYROLYSIS OF WASTE PLASTICS If the stormwater discharges to a municipal separate storm sewer system (MS4), name the operator of the MS4: ❑ N/A 3. Consultant (if applicable): Name of consultant: Consulting firm: CHALAM V. PAKALA CP ENGINEERING & ENVIRONMENTAL SOLUTIONS Street address: City: State: Zip Code: 10017 ALLYSON PARK DR. CHARLOTTE NC 28277 Telephone number: Email address: 704-756-7451 CVPAKALA@CAROLINA.RR.COM 4. Clutfall(s) At least one outfall is required to be eligible for coverage. 3-4 digit identifier: FName of receiving water: Classification: ❑ This water is impaired. I OUTFALL-001 I LITTLE CREEK/MOCCASIN CREEK QNSW El This watershed has a TMDL. Latitude of outfall: Longitude of outfall: 35"49'42.22"N 78"18'22.49"W Brief description of the industrial activities that drain to this outfall: STORAGE OF A NON-HAZ WASTE CHAR DUMPSTER, TRASH DUMPSTEER, YARD AND WATER FROM AN OILMATER SEPARATOR Do Vehicle Maintenance Activities occur in the drainage area of this outfall? ❑ Yes 0 No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? 3-4 digit identifier: Name of receiving water: Classification: ❑ This water is impaired. ❑ This watershed has a TMDL. Latitude of outfall: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? 171 Yes ❑ No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? 3-4 digit identifier: Name of receiving water: Classification: ❑ This water is impaired. ❑ This watershed has aTMDL Latitude of outfalI: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? ® Yes E3 No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? All outfalls must be listed and at least one outfall is required. Additional outfalls may be added in the section "Additional Outfalls" found on the last page of this NOI. Page 2 of 5 S. Other Facility Conditions (check all that apply and exalain accordinalv): ❑ This facility has other NPDES permits. If checked, list the permit numbers for all current NPDES permits: NONE ❑ This facility has Non -Discharge permits (e.g. recycle permit). If checked, list the permit numbers for all current Non -Discharge permits: NONE O This facility uses best management practices or structural stormwater control measures. If checked, briefly describe the practices/measures and show on site diagram: CONCRETE DIKE FOR OIL STORAGE TANKS, OlUWATER SEPARATOR, SPILL CONTROL KITS, INSPECTIONS ❑ This facility has a Stormwater Pollution Prevention Plan (SWPPP). If checked, please list the date the SWPPP was implemented: IN PREPARATION ❑ This facility stores hazardous waste in the 100-year floodplain. If checked, describe how the area is protected from flooding: NONE O This facility is a (mark all that apply) O Hazardous Waste Generation Facility ❑ Hazardous Waste Treatment Facility ❑ Hazardous Waste Storage Facility ❑ Hazardous Waste Disposal Facility If checked, indicate: Kilograms of waste generated each month: Type(s) of waste: > 2200 LBS D001 How material is stored: Where material is stored: DRUMS INSIDE THE BUILDING Number of waste shipments per year: Ns ite eF t eitsl e@A/disposal vendor: 5-10 GREEN AMERICA RECYCLING ixmpeft/disposal vendor EPA ID: Vendor address: MOD054018288 110107 HWY 79, HANNIBAL, MO ❑ Thisfacility is located on a Brownfield or Superfund site If checked, briefly describe the site conditions NONE 6. Required Items (Application will be returned unless all of the following items have been included): O Check for $100 made payable to NCDEQ 0 Copy of most recent Annual Report to the NC Secretary of State 0 This completed application and any supporting documentation O A site diagram showing, at a minimum, existing and proposed: a) outline of drainage areas b) surface waters c) stormwater management structures d) location of stormwater outfalls corresponding to the drainage areas e) runoff conveyance features f) areas where industrial process materials are stored g) impervious areas h site property lines O Copy of county map or USGS quad sheet with the location of the facility clearly marked Page 3 of 5 7. Applicant Certification: North Carolina General Statute 143-215.68 (1) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article ... shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). Under penalty of law, I certify that: 0 1 am the person responsible for the permitted industrial activity, for satisfying the requirements of this permit, and for any civil or criminal penalties incurred due to violations of this permit. 0 The information submitted in this NOI is, to the best of my knowledge and belief, true, accurate, and complete based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information. 0 1 will abide by all conditions of the NCG080000 permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. O I hereby request coverage under the NCG080000 General Permit. Printed Name of Applicant: MR. JEFF NEUMANN Title: CHIEF ADMINISTRATIVE OFFICER (Signature of Applicant) Nov 11, 2022 (Date Signed) Mail the entire package to: DEMLR —Stormwater Program Department of Environmental Quality 1612 Mail Service Center Raleigh, NC 27699-1612 Page 4 of 5 Additional Outfalls 3-4 digit identifier: Name of receiving water: Classification: ❑ This water is impaired. ❑ This watershed has a TMDL. Latitude of outfall: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? ❑ Yes ❑ No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? 3-4 digit identifier: Name of receiving water: Classification: ❑ This water is impaired. ❑ This watershed has a TMDL. Latitude of outfall: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? ® Yes 13 No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? 3-4 digit identifier: Name of receiving water: Classification: ❑ This water is impaired. ❑ This watershed has a TMDL. Latitude of outfall: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? ❑ Yes ❑ No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? 3-4 digit identifier: Name of receiving water: Classification: is water is impaired. ❑ This watershed has a TMDL. Latitude of outfall: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? [--]Yes ❑ No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? 3-4 digit identifier: Name of receiving water: Classification: ❑ This water is impaired. ❑ This watershed has a TMDL Latitude of outfall: Longitude of outfall: Brief description of the industrial activities that drain to this outfall: Do Vehicle Maintenance Activities occur in the drainage area of this outfall? I3Yes ❑ No If yes, how many gallons of new motor oil are used each month when averaged over the calendar year? Page 5 of 5 + x. ® ® Ygme O 517NInduNrtl Dc._ X Q ae , 88 Surface Water Classifications: aa. R,: ro.. $ ? Stream Index: 27-86-2-4 M P9 Stteem Neme: Little Creek(Wert Side) v — - '� Drscripdon: From source m.Moccesin W pna Creek Classification: C:NSW 4 xows .`p d 2 , Ome, of Class.: April30,1988 w. t EGemo^ e5a x lw l.� i4�. Whet does this Class. mean? View River Basin: Neuse > r5 ptW�s o^Pw 'lw iri 5t _ ( p� e2 Wlan 17 wa+q w��tl oio'e '� Polo � ^ii N M^i t>u� i 'FxeA - Vea g ? S p E gpsaZ. ��� � `5 anwwam ,e h\\\\ eaa ^ YlP ,nS Aga 300 -. �sv°°rtA ue oWc.r Goo n. n_._ Ge, n:.m och,. NC TMDL and TMDL Alternative Watersheds Project ListI' N. KvrEeeYaryTR1Dl PIan T," M.Retln Pael"I lmultipw elec -. @.use N,,,xer 0 517 N.Indu.pial D,.AEu X Qi1= o Maiw Rlve, BaAns xL`nwLn n,pmL e ,z.___. —_._._____.__ TMDL and MI —Wove Plan � - Watarehede ,nay -_. i^ - Pon Type TMDL ' �- W�mmn.SJ.m Grmmpem y� DuIRim 4R(AhYneuWTMDLI lnmr NIpIr PWm R«NMnun _, Sr ITMDLtlNem.l O Mwpemm xeery swnxll. A.Iwre Rele pA Lll.' W.H. SWaM SMIM <Ne,lalY 4eILW°m.: Ageb' n-•. N Click wFoc for infoTmetion on the Statewide Mercury- ryurilM TMDL sPm.ne•re n«NnRn.m .. R«t. .NCWiwlll. Project Details m Gu..raat 'imm. Mlmlgtm Se4aepmjMfiom dro lin above -"" C.4erble WYm. Be.N I.e.mm rnlwpe Scuwr?vi.xM. G.—. PRO N044 WW G0RW4tenW.. zlt.,s I. N. GI6 U' .Com 'INCDE6 Dviv OWare, Rewuru,Ol—fa.n%G'a INC' Elll, HERE, G. Powered R, Es, FIGURES Figure-1 Site USGS TOPO Map Figure — 2 Site Drainage Maps -nmaotn ca� cc<m mono my z 00 z�oz . zD N m N D 0o r r r n ' 49' 00.00" N 035' 49' 30.00" N 035' 50' 00.00" N 035' 50' 30.00" N 035` m (D a m t s N a�.fj�, j'� a �e?CQgsti w W C rf 8 e'Roa Nance Cir �o �� Nf �� �e l N N peoa•!oo �g pied"ayS ` oda1�� F1 '- o aP w Q N„o oa, 'i S,t� o \ m c Z7 �3 o �p U. u � C3 m^'' � 3a i / m n ���,l m m 0 mhA l Z d = A ws ° :ive m o r l z� a/w co Ilan P!a, d - f ~ jrxa / N to 035' 48' 30.00" N 035' 49' 00.00" N 035" 49' 30,00" N 035' 50' 00.00" N 035' 50' 30.00" N I I I I I 1 0135' LEGEND ON. SOURCES) 1 10.000 Gl1AN MI%EO Cu PYPOLY515 OIL ® IMPEWOUS SURGRCE (BUILDINGS) 2 3.-0o GALLON HGW CM PYROLYSIS OIL �. IMPEWOUS SURFACE (CONCRETE) 10.000 MN MEDIUM CUT PYROLNNIS OIL IBAco c+LON WnsiE Pu C$, MOLDED LOW GUT OIL DL-1 DRUNUE AKEA m S UISTIW110N COLUMN ——DRANUE MG SOUNDMA 8 60 ON MID CUT PYROLSS OIL TANK G 0 mKKSFORMER 275/55 GALLON USED OIL k DIKE WATER TOTES/DRUMS (10-30) � WATER ROW DIRE"ON T NSFORMER D1 DROP INLET B BULK LOADING MOBILE TANKER SPILL CONTROL KR --- PROPERTT BOUNOM' .n,6 mevn <e eMeloM. R...1DR..AL mtl r 5 .e um. 1... (cPCt5) d IIbiY pxnnna entl <aMrv.bn b tl°piq 1" B UPflLINON WXIR%NYO COUNTERMEASURE PLW pMB G-9r, larlal Mope. Ceuny PIS 0 3P W em IMa-,l O'EEs'.'I K. nYM,el°11 K I®4°i.�.ee.1 ia, uN' T°^T."a^Rrvnim E. w,ry ... I. a.. b. e.a,.M aM d-I "°`N WIEALL / D.NPCE MG DISCRANGE IMPE,,oUS MU PEWOU9 MEA }OiK A9RE5 (.ACRES) (ACRES) (AWES) 01 Oq_I' OUIENL 01 OP ACRES LIS ACRES I.BO R. (SS,.31 SO. EI.) (AB.OSS SO. R) 0.,152 SO. Fr.) W-2 SNEEE TIAW 0.0 ACRES 1.31 ACRES IX ACRES 00 BID. R.) (59.568 SO. ER) (59568 so, R.) TOTALS O.T ACRES 2.50 ACRES ]22 ACRES (31.7 SO. H.) (IOB.5B5 SO. a..) (112.500 SO. n..) PROCESS FLOW DIAGRAMS AND OIL/WATER SEPARATOR INSTALLATION DETAILS Zebulon Wastewater System Process Flow Diagram ( Max. Capacity Operation ) Tank 100 Tank 101 Sump Flow 300 gpm Oil Water Treated Storm Water Pump #1 Containment (100gpm) Separator Wastewater Outfall Area Process Equipment Containment Area Tote Recovered (275 gal.) Oil Tank 102 Sump Tank 103 Pump #2 Containment (100 gpm) Solids Area GRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL 1 Zebulon Containment Areas iFFit-• Sumd/Pump e•',. 1— T Tank 100 & 101 y�To-,m III II O PLAN AT GRADE }} no* TO scnLE Tank 102 & 103 Containment An BRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL 3 Zebulon Facility with Oil Water Separator PLAN AT GRADE worm x GRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL Oil w.l. SOPMM cmNimsit Oo Tote oa Wow 5rspa•amr 2 Zebulon Facility with Oil Water Separator (Detai U Truck Loading Containment Are 2 NIL i �r Sumoipump SLmp P.jrnp Tank 100 & 101 Tank 102 & 103 COntanment Are Containment Area BRAVEN ENVIRONMENTAL, LLC CONFIDENTIAL view) Oil water 04 Tpte r Separator 5 (� OIL WATER SEPARATOR TECHNOLOGIES, LLC TECH 1109 25th STREET, STE. E & F WEST PALM BEACH. FL 33407 1-800-770-0099 WWW.OWSTECH.COM 161TIT1L 11:14.'I STANDARD MODEL# O WS-SA-H F-SS-300 ENVIRO VAC OWSTECH JOB# 18005 INSTALLATION, OPERATION, AND MAINTENANCE BROCHURE OWS TECH 1109 25TH Street, Ste. E & F West Palm Beach, FI 33407 TABLE OF CONTENTS Installation, Operation, Maintenance Oil Water Separator Specification OWS Model (SA-HF-SS-300) Anchor Bolt Location 6" 0 Rotary Pipe Skimmer Coalescing Filters (Tube Arrangement) OWS-STD OWS-STD Drawing #4S5236 Drawing #3S5218 Drawing #3S5129 Drawing #1S5013 OWS TECH 1109 25" STREET WEST PALM BEACH, FL 33407 Installation, Operation and Maintenance Instructions for above grade models (SA-HF-SS-300) Installation: 1. Locate separator at desired location using the supplied lifting lugs. 2. Inlet Pipe- Attach to waste water source. 3. Outlet Pipe- Attach to discharge. 4. Oil Outlet Pipe- Attach to oil storage tank or install shut-off valves. 5. Drains- Install shut-off valves and/or pipe back to sump pit. 6. Install anchors using the supplied anchor bolt location drawing. Operation: 1. Fill unit with clean water. 2. Introduce waste water stream at or below the separators rated flow rate per minute. 3. Rotate oil skimmer to a vertical position. 4. Oil will accumulate at the surface. 5. Clean water will pass thru the unit to the discharge pipe. 6. Solids will fall to the bottom of the inlet chamber as well as under the coalescers in the separation chamber. Maintenance: 1. Remove oil layer by rotating skimmer pipe open area towards oil. Remove excess oil only to avoid removing clean water. Minimum oil level build up prior removal %" or approximately 15 gallons. Maximum oil level build up before affecting the separation process is 4 inches or approximately 120 gallons. 2. Check for solids build up. A. Rotate vertical fiberglass angles upward to remove front horizontal hold down angle. B. Remove front horizontal hold down angle. C. Remove center bundle from the first row and check to see if there are solids in the bottom portion of the bundle. D. If solids are present it is time to remove the coalescers and clean. E. Remove grating and the solids from the bottom of the separator. F. Reinstall grating, coalescers and hold down angle. G. Fill unit with clean water. Unit is now ready for operation. OWS TECH 1109 25th STREET WEST PALM BEACH, FL33407 SQUARE ABOVE HIGH FLOW (SA-HF) SERIES SPECFICATION Model Number (SA-HF-SS-300) Design Parameters: Installation Flow Rate Oil Removal Oil Storage Capacity Oil Spill Capacity Sludge Capacity Operating Capacity Empty Weight Estimated Operating Weight Estimated Operating Temperature Materials of Construction: Tank, baffles, lid, nozzles, fitting, Hardware, and identification tag High Efficiency Coalescers (HEC) Packs Rotary Pipe Skimmer Rotary Pipe Skimmer Mounting Bracket Grating Above Ground 0-300 GPM 20 Micron Size and larger down to 10 ppm 120 Gallons 810 Gallons 36 Cu/Ft. 2,450 Gallons 6,111 LBS. 26,520 LBS. 33 —130 degrees Stainless Steel 304 L Polypropylene (FRP) (FRP) (FRP) OWS TECH 1109 25"i STREET WEST PALM BEACH, FL 33407 Nozzles: Inlet One (1) 4" 0 Flanged Outlet One (1) 8" 0 Flanged Oil Outlet One (1) 6" 0 Flanged Level Switch One (1) 2" 0 Flanged Drains/Solids Three (3) 2" 0 Flanged Vent One (1) 2" 0 Flanged Separator Internals/Chambers: Inlet Diffuser Evenly distributes flow Inlet Chamber Collects solids Inlet Baffle Directs flow thru (HEC) Pack Separation Chamber Removes 20 micron size and larger oil droplets using 114 Cubic ft. or 5,244 Sq. Ft. of High Efficiency Coalescers (HEC) pack. Sludge/Solids Chamber Allows solids to collect below the High Efficiency Coalescers (HEC) Pack for easy solids removal. Oil Retention Baffle Retains floating oil for removal utilizing the rotary pipe skimmer. Weir Wall Maintains a constant water level in the separation chamber. Outlet Chamber Clear well complete with 8" 0 Tee Pipe to allow only the cleanest water to exit the Separator. OWS TECH 1109 25' STREET WEST PALM BEACH, FL 33407 Separator Access: Manways One (1) 5'-3" x 4'-0" One (1) 4'-0" x 2'-0" ri 5A-HF-SS/CS-300 G.P.M. EWRO VAC r D Z G m r N I nw o-4 O u u I I to L m o o z e U m a m n r n K p p £ S Z Z O O S a mo m z F- a i @ a 00 Z o � G1 - 9 V O o 0 i z n o v 1W S 8005 OIL WATER SEPARATOR ° `455TECHNOLOGIES, USN.T.S. TECH 1109 25TH STREET —e TMB tv A rn F- r D Z < N m c w I" 2DO r ro NOZZ2 A m to N A N T m I" O\ o s Og N 0 : z O m rn NIA 54-HF-58-30L 18005 Amkm OIL WATER SEPARATOR TIE DOWN BOLT HOLE LOCATIONS TECHNOLOGIES LLC N.T.S. TMB ENVIRO VAC �b55218 e %wmm011.mwrn o 1109 25TH STREET W.P.B., FL 3d40] ro 1/1]/18 ^�,� -- — TEr7a � I I � T � i € m � E D = � e qI E rn L J n c E O D + A Z c D � I m � S4—HF—SS-300 6'0 ROTARY PIPE SKIMMER 18005 OIL WATER SEPARATOR ENVIRO VAC �355129 ® 5� TECHNOLOGIES,, LL4 ""e N.T.S. �v"` m..0 TUB .z>+. 111. TES 1109 25TH STREET W.P.B., F4/21/15 � ..: ms D Z m En I 0 O O O c G O O O 0 G 0 0 0 G G G G G G O O O O O mom on JOB N. SA—HF—SS-300 TUBE ARRANGEMENT 18005 ® OIL WATER SEPARATOR O JOS DMA No. -W DPANIND AND SPEDIGTON l "' s TECHNOLOGIES LLC N.T.S. THE PROPE"IY oP ows £"""rocks D� TMB ENVIRO VAC 155013 M a 7 AND S oT B eFLH' nc: Im TA 1/17/18 TECH 1109 25TH STREET W.P.B., FL. 33407 wTe12/10/13 � c m+ cNcc�aD er. Chalam Pakala 10017 Allyson Park Dr., Charlotte, NC October 21, 2022 Ms. Brittany Carson, Permit Coordinator NC DEMLR — Stormwater Permitting Unit 1612 Mail Service Center Raleigh, North Carolina 27699-1612 919 707 3641 office bethanv. eeorgoulias(aD,ncdenr.gov and Environmental Solutions 7451, Fax: Re: NPDES Stormwater General Permit (NCGO80000) Approval Request Braven Environmental, LLC 517 N. Industrial Dr. Zebulon, Wake County, North Carolina 27597 CPEES Proiect No. 1202-001 Dear Ms. Carson: On behalf of Braven Environmental, LLC (Braven) located at 517 N. Industrial Dr., Zebulon, North Carolina, CP Engineering and Environmental Solutions (CPEES) is pleased to submit the attached Stormwater NPDES General Permit (NCGO80000) request for the subject facility operations. The facility manufactures liquid petrochemicals using waste plastics via pyrolysis method and the generated products are stored on site in an aboveground storage tanks contained in a concrete dike. The operations are conducted under SIC/NAICS Code 2869/32511"Petrochemical Manufacturing ". No Stormwater General Permit exists for the above SIC code, however, Braven will be installing an Oil/Water Separator to process stormwater collected in the tanks concrete dike. We intend to discharge the water from the oil/water separator to an outfall at the facility. All collected oils in the oil/water separator will be either recycled in the plant or disposed of properly using a licensed disposal contractor. The outfall location with lattlong is provided on the Site Drainage Map. The Stonnwater NPDES General Permit Application package includes: • A check for $100 Payable to NC DEQ: • A signed NC DELMR supplied NCG080000 NOI application; • Process Flow Diagrams and proposed OiUWater Separator installation details: • USGS TOPO Map; • Site Drainage Map showing the proposed Oil/Water Separator location; • Site Drainage Map showing the location of the outfall from the facility; and • TMDL and 303(d) Maps. Please call me at 704-756-7451 or Mr. Chris Serrati at 501-628-4793 or Alex Gonzalez at 305-710-4539 should you have any questions on this permit application request. Respectfully submitted, CP Engineering and Environmental Solutions \ �Q NESAI e (A Cost E ctive Sohnion Provider or Manv acturin ��� ;a SEAL .19807 Chalam V. Managing Pr��paP E 111tPx\ 10/21/2022 Attachment: NPDES NCG080000 Application Package NPDES STORMWATER GENERAL PERMIT (NCG08000) NOI FORMS