HomeMy WebLinkAboutNCG060184_2022 DMR_20220822W
NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG060000
Food and Kindred
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMRj U load form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG060184 I Person Collecting Samples: Jeremy Spencer
Facility Name: Pilgrim's Pride Corp., Wingate Feed Mill Laboratory Name: K & W Laboratories
Facility County: Union _ Laboratory Cert- No.: 559
Discharge during this period: ✓❑ Yes No (if no, skip to signature and date)
Has your f4lity implemented mandatd�y Tier response actions t ampleperiod for any be 9hmark exceedances? 0 ❑ No
If so, which Tier (I, ll, or III)? 1.
A copy of this DMR has been uploaded electronically via https://edocs.deo.nc.gov/Forms/SW-DMR ❑✓ Yes [-]No
Date Uploaded: August 18, 2022
Analytical Monitoring Requirements for Outfalls with Industrial Activities - Benchmarks in (Red)
Parameter
Code
Parameter
Outfall#001A
Outfall#002A
Outfall
Outfall
Outfall
N/A
Receiving Stream Class
Rays Fork Creek
Rays Fork Creek
N/A
Date Sample Collected MM/DD/YYYY
7/26/2022
7/262022
46529
24-Hour Rainfall in inches
0.8
0.8
C0530
TSS in mg/L (100 or 50*)
13
22
00400
pH in standard units (6.0-9.0)
7.9
7.5
00556
Oil & Grease in mg/L (30)
<5.9
<5.9
Fecal Coliform per 100 ml of
31616
freshwater (if required) (1000)
est>600
est>600
61211
Enterococci per 100 ml of saltwater
(if required) (500)
Chemical Oxygen Demand in mg/L
00340
(120)
41
50
Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average
Estimated New Motor/Hydraulic Oil
NCOIL
Usage in gal/month
64
64
00552
Non -Polar Oil & Grease in mg/L (15)
<5.9
<5.9
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 200 mg/L
Notes (optional):
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false information, including the possibility of fines and imprisonment for knowing violations."
Signature of Permittee or Dele ted Authorized Individual
Email Address Micah.Abernaty@pilgrims.com
Date
Phone Number (704) 624-4448
K & W Laboratories
1121 Hwy 24/27 W
Midland, North Carolina 28107
Tel (704) 888-1211 Fax (704) 888-1511
Client: Pilgrims Pride Corp.
205 Edgewood Drive
Wingate, NC 28174
Project: "'Wingate Feed Mill Sto4water
Location: Outfall #001A
SAMPLE # PARAMETER
22072701-01
22072701-01
22072701-01
22072701-01
22072701-01
22072701-01
COD
Fecal Coliform
Oil&Grease
pH
SOT -HEM, TPH
TSS
RESULT
41
ast>600
<6.9
7.9
<5.9
13
Results Report
Date: 11-Aup--22
OrderlD: 22072701
Collect Date:
7/26/2022 14,
Collect Time:
110
2.00:00 PM
REPORTING ANALYSIS
UNITS
METHOD
LIMIT DATE
mg/L
SM5220D
10 8/10/2022
colony/100ml
SM9222D (MF)
1 7/26/2022
mg/L
EPA16643
5.9 8=022
units
SM4500H+B
0.1 7126/2022
mg/L
EPA1664B
5.9 81=022
mg/L
SM2540D
3.1 7/2812022
pH analysis initiated more than 15 minutes after sample collection.
Fecal Coliform: Estimated Result. All dilutions produced too many colonies to count.
NC Certification: 669 SC Certification: 99061
Certified By
G. Kraska / Lab Director
A
0
K & WTPaaboratories
1121 Hwy 24/27 W
Midland, North Carolina 28107
Tel (704) 888-1211 Fax (704) 888-1511
Client: Pilgrims Pride Corp.
205 Edgewood Drive
Wingate, NC 28174
Project-Aloo Wingate Feed Mill St'�rmwater
,
Location: Outfall #002A
SAMPLE #
PARAMETER
RESULT
22072702-M
COD
50
22072702-01
Fecal Coliform
eat>600
22072702-01
Op&Grease
<5.9
22072702-01
pH
7.5
22072702-01
SOT -HEM, TPH
<5.9
22072702-01
TSS
22
Results Report
Date: 1 I-Aue-22
Order ID: 22072702
Collect Date:
- 7/26/2022
Collect Time:
2:07:00 PM
REPORTING ANALYSIS
UNITS
METHOD
LIMIT DATE
mg/L
SM5220D
10 8/10/2022
colony/100ml
SM9222D (MF)
1 7/26/2022
mg/L
EPA1664B
5.9 8/2/2022
units
SM4500H+13
0.1 7/28/2022
mg1L
EPAIS64B
5.9 =12022
mg/L
SM2540D
3.1 7/28/2022
pH analysis initiated more than 15 minutes after sample collection
Fecal Coliform: Estimated Result. All dilutions produced too many colonies to count.
Certified By-
G. Kraska / Lab Director
oil
NC Certification: 569 SC Certification: 99051
Tel: 704-888-1211
Fax: 704-888-1511
Chain of Custody Record
Report To: r Y
IEmait: Yin-Pong.ChanQOPiIarims.com
Copy To: Jeremy. SDencerQpiIgrims.COm
Bitl To:
PON
T'
K & W Laboratories
1121 Hwy 24127 W Midland, NC 28107
Pilgrim; Oride
205 Edgewood Dr.
Wingate, NC 28174
Jeremy Spencer
ProJW Hama: "ate Feed Miiv Stormwater
Sampled By.
ReenquisW Ey
hale:
_
Tlma: Reretved Sy.
Ft1
Date:
Tkm:
samde Temp: Lax
ReengWshedBy.
Dale:
rune: Rece
Date �I7s�LZ
r 6
On Ice: 10 1 N