Loading...
HomeMy WebLinkAboutNCG030452_2022 DMR_20220815DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Re: Stormwater Discharge Outfall Monitoring Report: Tier III July Monthly for 3Q 2022 Carrier Corporation Mecklenburg County General Permit NCG030000, Certificate of Coverage NCG030452 Dear Stormwater Permitting Unit, We respectfully submit the enclosed original signed copy of the Stormwater Discharge Outfall Monitoring Report (DMR) for the Carrier Corporation facility under General Permit Number NCG030000, Certificate of Coverage Number NCG030452. This submission serves as the Tier III monthly sampling for July during sample period 31 Quarter 2022, as outlined in our stormwater permit. If you have any questions or comments regarding this Stormwater Discharge Outfall Monitoring Report (DMR) submission, please contact us at your convenience. Sincerely, k=-1 "—� — Annette Huntly Safety Coordinator Carrier Corporation Enclosures: Stormwater Discharge Outfall Monitoring Report (DMR) NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report DMR Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0452 Person Collecting Samples: Jaynes W. Willard II (INENCO, INC.) Facility Name: Carrier Corporation Laboratory Name: Pace Analytical Services, LLC Facility County: Mecklenburg Laboratory Cert. No.: 12. 40, 37706, 37712 Discharge during this period: [E Yes ❑ No (if no, skip to signature and dote) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? QYes © No If so, which Tier (I, II, or III)? III A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR Q Yes No Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmark3 in (Red) Parameter Parameter Outfall 1 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class Class C N/A Date Sample Collected MM/DD/YYYY 07/25/2022 46529 24-Hour Rainfall in inches 0.75 C0530 TSS in mg/L (100 or 50*) 36A pH in standard units (6.0 — 9.0 FW, 7.50 00400 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) 0.0122 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) < 0.0050 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.0623 Chemical Oxygen Demand (COD) in 00340 mg/L (120) < 25.0 00552 Nan -Polar oil & Grease in mg/L (15) < 4.8 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): pH sample collected and analyzed by James W. Willard It of INENCO, INC., North Carolina Field Services Certification #: 5540 "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware thzt there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." S1ignat/u`r�of Pe"ittee,& Delegated Authorized Individual Email Address IL44 Date 70 Phone Number