Loading...
HomeMy WebLinkAboutNC0090051_Renewal (Application)_20221201 (2) kc TsSTATE,� ROY COOPER . Governor =sal �y• r�o;. ELIZABETH S.BISER 17" Secretary / RICHARD E.ROGERS,JR. NORTH CAROLINA Director - - - Environmental Quality December 01, 2022 Georgia-Pacific Wood Products LLC Attn: Mason Curry, Plant Manager 139 Brewington Rd Dudley, NC 28333 Subject: Permit Renewal Application No. NC0090051 Georgia Pacific Dudley Plywood Facility Wayne County Dear Applicant: The Water Quality Permitting Section acknowledges the December 1, 2022, receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit.The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerecv StigA Wren Thedford Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/applicationE CV) - North Caro Drt of EroetalQuality I iiio Washington Regionallinaepa Office nvi 1943 Washingtonnmn Q Square Mali sI on Was ofhingtWateron,Res Northurces Carolina 27889 6ad..d omN 252.9466481 Georgia-Pacific Wood Products LLC GP Georgia-Pacific 1139iBrewi ywood ngt n Road Dudley, NC 28333 RECEIVED November 28,2022 DEC 0 1 2022 NC DENR/DWR/NPDES Unit NCDEQJDWWNPDES 1617 Mail Service Center Raleigh,NC 27699-1617 RE: Georgia-Pacific Wood Products LLC Dudley Plywood Facility NPDES Permit No.NC0090051 -Renewal Application Dear Sir or Madam: As required by the NPDES Permit No. NC0090051, attached are the original and 2 copies of the completed NPDES Application Forms for renewal of the current permit. This permit was originally issued on July 7, 2022 for the wet deck system. During the fmal design and install, it was determined that six sprinkler heads (instead of four) were required to provide proper coverage. The pond calculations have been updated to reflect the updated operations. The pond residence time will decrease form 88.3 hours to 53.2 hours as a result of the increase. The wet deck system is scheduled to commence operation December 15th,2022. Should you have any questions or need additional information, please contact Elizabeth Meyer, Complex Environmental Manager,at 910-547-7080 or via e-mail at elizabeth.meyerl@sapac.com gapac.com Sincerel Mason Curry Plant Manager Dudley Plywood Attachments: NC0090051 Renewal Application r r National Pollutant Discharge Elimination System Individual Permit Application Georgia Pacific Plywood Facility Dudley, Wayne County, North Carolina Prepared by: COURY ' scri'd=f 3 Etirit Alf411iG rs;C Coury Science&Engineering, PLLC PO Box 125 Hampstead, North Carolina 28443 November 2022 Georgia Pacific Dudley NPDES Permit Application November 2022 TABLE OF CONTENTS Section 1: Introduction 3 Permit Request and Permit Fees 3 Facility Information 3 Document Organization 3 Section 2: Site Information 5 Site Location 5 Description of Manufacturing Process 5 Site Map 6 Section 3: Effluent Description and Treatment 6 Description of Discharged Wastewater and Treatment 6 Estimated Effluent Data 6 Engineering Design of Settling Pond 6 Section 4: Application Form 8 Appendix 1 Site Map 9 Appendix 2 Topographic Map 10 Appendix 3 Wastewater Flow Line Diagram 11 Appendix 4 Stormwater supporting calculations 12 Page 2 of 13 t Georgia Pacific Dudley NPDES Permit Application November 2022 SECTION 1: INTRODUCTION Georgia-Pacific Wood Products LLC (GP) owns and operates a Plywood manufacturing plant in Dudley, Wayne County, North Carolina. GP operations are categorized under North American Industrial Classification System (NAICS) code 321212 for softwood veneer and standard industrial classification (SIC) code of 2436 for softwood veneer and plywood. The facility is proposing to permit wastewater discharges from a wet deck operation. PERMIT REQUEST AND PERMIT FEES The GP Dudley facility is covered by NPDES Permit NC00900051 with an expiration date of May 31, 2023. This renewal application is being submitted at least 180 days prior to expiration. Included in this package is one original and two copies of the application as required. GP is requesting to add the following non-stormwater discharge activities to the permit as part of the renewal: 1. Discharges from emergency/unplanned fire-fighting activities; 2. Fire hydrant flushings; 3. Potable water, including water line flushings; 4. Uncontaminated condensate from air conditioners, coolers, and other outside storage of refrigerated gases or liquids; 5. Irrigation drainage; 6. Landscape watering, provided all pesticides, herbicides, and fertilizers applied in accordance with the approved labeling; 7. Pavement wash waters where no detergents or cleaning products are used; 8. Routine external building washdown power/wash water that does not use cleaning products; 9. Uncontaminated ground water or spring water; 10. Foundational or footing drains where flows are not contaminated with process materials; Additionally, during the final design and install,it was determined that six sprinkler heads were required to provide proper coverage.The pond calculations have been updated to reflect the updated operations. The pond residence time will decrease form 88.3 hours to 53.2 hours as a result of the increase. FACILITY INFORMATION The physical and mailing address for GP facility is as follows: 139 Brewington Road Dudley, North Carolina 28333 To facilitate review of this application, please contact the following individuals identified below. Preparer's Contact Information: Facility's Contact Information: Sean Coury, PE(NC) Elizabeth Meyer Partner Environmental Manager Coury Science& Engineering, PLLC Georgia-Pacific Wood Products LLC (910)319-0017 Dudley Plywood and Chip-N-Saw sean.coury@couryse.com (910)547-7080 Elizabeth.meyerl@gapac.com DOCUMENT ORGANIZATION Page 3 of 13 Georgia Pacific Dudley NPDES Permit Application November 2022 This permit application is divided into five sections and various appendices. Tables are included throughout the document and are referenced in the table of contents. The seven sections and four appendices are as follows: Section 1 Introduction Section 2 Site Information Section 3 Effluent Description and Treatment Section 4 Application Form Refer to the table of contents for a detailed listing of tables and figures. Page 4 of 13 Georgia Pacific Dudley NPDES Permit Application November 2022 SECTION 2: SITE INFORMATION This section provides information on the site location,surrounding terrain, and description of industrial activities. SITE LOCATION The GP Dudley Complex is located in Dudley,North Carolina in Wayne County.The approximate Universal Transverse Mercator (UTM) coordinates of the facility are Zone 17, 769.8 km east and 3,906.1 km north, at an elevation of approximately 180 feet above mean sea level. Refer to the Area Map in Appendix A for additional details. DESCRIPTION OF MANUFACTURING PROCESS The GP Dudley Facility consists of a Chip-N-Saw (CNS) lumber mill and a Plywood manufacturing facility. The co- located CNS Mill is separated from the Plywood Plant by a CSX rail spur that runs east to west with the manufacturing areas of the Plywood Plant situated south of the spur.The Plywood Plant operates under North American Industry Classification System (NACS) Code 321212, Softwood Veneer and Plywood Manufacturing, and employs up to 400 employees. The CNS Mill operates under NAICS Code 321213, Softwood Sawmill, and employs approximately 170 employees. Production process areas at the plywood facility consist primarily of the logyard, green end (lathes), dryers,presses,finishing/shipping,and the boiler. Major production processes for the CNS include sawing(sawmill), drying(kilns),and finishing(planer mill).The facility operates 24 hours per day,7 days per week. The Plywood Plant receives pine and softwood logs and stores them on the log yard prior to processing.The logs are debarked,cut to length,conditioned in steam-heated dryers,graded and formed into plywood panels by gluing and pressing. After pressing, the plywood sheets are trimmed, sanded, and sorted for shipping. Finished product and manufacturing process residuals are shipped offsite via truck and rail. The topography of the GP Dudley Plywood Plant and surrounding area is relatively flat.Stormwater runoff from the majority of the manufacturing areas from the Plywood Plant that is not conveyed to the wet deck pond is discharged to Outfall 001. The outfall is located at the southwest corner of the property.Stormwater runoff from the majority of the manufacturing areas of the Plywood site generally flows south or southwest via sheet flow, soil ditches, or underground piping into the spill retention pond located along Brewington Road on the south side of the Plant.The spill pond discharges into the Plant's stormwater treatment pond and then to Outfall 001. Runoff from the northern part of the Plant flows west and then south via an open soil ditch directly to Outfall 001. Stormwater runoff from a grassed area on the northwest corner of the Plywood facility discharges to Outfall 002 under North Carolina Department of Environmental Quality(NCDEQ)General Permit NCG210000(COC NCG210168). Outfall 002 discharges into an open ditch on the west side of the railroad (located on the west side of the facility). This ditch converges with the discharge from Outfall 001, which discharges to an unnamed tributary of Brooks Swamp. The Plywood Plant's nondischarge wastewater permit (WQ0003380) requires that all categorical non-discharge process wastewater and the effluent from the facility's oil water separator be recycled or discharged to the county wastewater treatment facility (POTW). All sanitary wastewater, with the exception of the training room, is discharged to the POTW. Sanitary wastewater from the training room is discharged to an on-site septic tank/leach field located on the east side of the office building. Georgia Pacific Dudley NPDES Permit Application November 2022 SITE MAP A site map depicting the facility and surrounding areas is located in Appendix 1. The log storage area where the wet deck operation will take place has been outlined in red and the location of the settling basin is outlined in blue. The facility outfall location has been denoted with a red star on the site map. A topographic map that shows the terrain of the site and surrounding areas is included in Appendix 2. SECTION 3: EFFLUENT DESCRIPTION AND TREATMENT This section describes the effluent that will be generated from the wet decking operation and the method of wastewater treatment. DESCRIPTION OF DISCHARGED WASTEWATER AND TREATMENT Georgia-Pacific is proposing to permit discharge from a wet decking operation,which will be used to spray water onto the log storage piles especially during warmer, dryer months. Water will be pumped from the stormwater collection pond or from a groundwater well and then sprayed onto logs stockpiled on the wet deck via spray nozzles. The wet decking pad will be paved with concrete and will be sloped in a manner that will ensure water will flow into a detention/settling pond prior to discharge via Outfall 001,indicated on the site map in Appendix 1. The wet decking operation consists of six sprinkler heads,each with an approximate flow rate of 113 gallons per minute(gpm). The calculated maximum flow rate is 0.979 million gallons per day(MGD),assuming 113 gpm from each of six sprinkler heads for 1,440 minutes per day. No chemicals will be added for the wet decking operation. A water flow line diagram is included in Appendix 3. ESTIMATED EFFLUENT DATA US EPA effluent limitations guidelines for Timber Products Processing(40 CFR 429),Subpart I,Wet Storage Subcategory,states that there shall be no debris discharged from the wet decking operation and provides ranges for effluent pH. As required by these federal effluent limitations guidelines,there will be no debris present in the effluent and the pH will remain within the range of 6.0 to 9.0. To ensure that no debris will be present in the discharge,all runoff associated with the wet decking operation will be routed to a settling pond prior to discharge. In accordance with the Neuse River Basinwide Water Quality Plan, Brooks Swamp is classified as a NSW(Nutrient Sensitive Water)which requires wastewater dischargers to set permitted nitrogen and phosphorus limits of 3 mg/I and 1 mg/I, respectively. Based on the characteristics of the wastewater stream and the design of the wet settling basin, effluent nitrogen and phosphorus quantities are expected to be well within these specified limits. The water withdrawal/discharge system is designed to have the option of operating as a single pass system to prevent concentrations of BOD from increasing. The wet deck operation will have the option of pulling water out of the collection pond during wet weather periods where the pond is turning over frequently or from a groundwater well during drier periods. Additionally,incoming water will pass through a filter to minimize the amount of bark that is introduced to the settling basin. The facility will also have the option of diverting wastewater to the spill pond to provide an additional pretreatment step and reduce solids in the permanent pool. ENGINEERING DESIGN OF SETTLING POND The runoff from the wet decking operation will be diverted to a wet detention pond prior to discharge to surface waters. The pond has been designed in accordance with USDA Soil Conservation Services Practice Standard Code r Georgia Pacific Dudley NPDES Permit Application November 2022 No.378 and the North Carolina Department of Environment and Natural Resources(NCDENR) Practice Standards and Specifications for Sediment Basins. Appendix 4 includes a drawing of the settling pond and supporting calculations. The pond is designed with a 3.3:1 length to width ratio,which is greater than the recommended minimum of 2:1. The volume of the pond is 284,000 cubic feet and results in a hydraulic residence time of 53.2 hours at maximum dry weather flows. Additionally,the facility will be designed with the option of diverting wastewater to a 35,000 cubic foot spill pond to enhance solids removal and reduce the cost of pond cleanouts. Georgia Pacific Dudley NPDES Permit Application November 2022 SECTION 4: APPLICATION FORM EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 Form U.S.Environmental Protection Agency 1 2 EPA Application for NPDES Permit to Discharge Wastewater NPDES GENERAL INFORMATION SECTION 1.ACTIVITIES REQUIRING AN NPDES PERMIT(40 CFR 122.21(f)and(f)(1)) 1.1 Applicants Not Required to Submit Form 1 1.1.1 Is the facility a new or existing publicly owned 1 1 2 Is the facility a new or existing treatment works treatment works? treating domestic sewage? If yes,STOP.Do NOT complete No If yes,STOP.Do NOT No Form 1.Complete Form 2A. complete Form 1. Complete Form 2S. 1.2 Applicants Required to Submit Form 1 .. 1.2.1 Is the facility a concentrated animal feeding 1.2.2 Is the facility an existing manufacturing, operation or a concentrated aquatic animal commercial,mining,or silvicultural facility that is a production facility? currently discharging process wastewater? Yes 4 Complete Form 1 ❑✓ No D Yes 4 Complete Form ❑✓ No a and Form 2B. 1 and Form 2C. `o 1.2.3 Is the facility a new manufacturing,commercial, 1.2.4 Is the facility a new or existing manufacturing, mining,or silvicultural facility that has not yet commercial,mining,or silvicultural facility that commenced to discharge? discharges only nonprocess wastewater? 0 E✓ Yes 4 Complete Form 1 ❑ No Yes 4 Complete Form E No ce and Form 2D. 1 and Form 2E. N 61 1.2.5 Is the facility a new or existing facility whose .5 discharge is composed entirely of stormwater associated with industrial activity or whose discharge is composed of both stormwater and non-stormwater? Yes 4 Complete Form 1 0✓ No and Form 2F unless exempted by 40 CFR 122.26(b)(14)(x)or b 15 . SECTION 2.NAME,MAILING ADDRESS,AND LOCATION(40 CFR 122.21(f)(2)) 2.1 Facility Name Georgia-Pacific Wood Products LLC Dudley Plywood Facility 0 2.2 EPA Identification Number w co U 110000349855 2.3 Facility Contact ui Name(first and last) Title Phone number --0 Elizabeth Meyer Facility Environmental Manager (910)547-7080 Email address elizabeth.meyerl@gapac.com 2.4 Facility Mailing Address Street or P.O.box 139 Brewington Dr City or town State ZIP code Dudley NC 28333 EPA Form 3510-1(revised 3-19) Page 1 , EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 H d 2.5 Facility Location -a Street,route number,or other specific identifier Q r c 139 Brewington Dr �U c o County name County code(if known) Wayne d City or town State ZIP code z Dudley NC 28333 SECTION 3.SIC AND NAICS CODES(40 CFR 122.21(f)(3)) 3.1 SIC Code(s) Description(optional) 243 Millwork,plywood,and structural members N N .D 0 U U • 3.2 NAICS Code(s) Description(optional) 10 321212 Softwood veneer and plywood manufacturing SECTION 4.OPERATOR INFORMATION(40 CFR 122.21(f)(4)) 4.1 Name of Operator Georgia-Pacific Wood Products LLC • 4.2 Is the name you listed in Item 4.1 also the owner? w� A 0 ❑✓ Yes ❑ No 4.3 Operator Status g` ,a D Public—federal ❑ Public—state ❑ Other public(specify) P fy) o ❑✓ Private ❑ Other(specify) 4.4 Phone Number of Operator (910)547-7080 4.5 Operator Address O Street or P.O. Box 139 Brewington Rd wCity or town State ZIP code w v Dudley NC 28333 0_ Email address of operator elizabeth.meyerl@gapac.com SECTION 5.INDIAN LAND(40 CFR 122.21(f)(5)) 0 5.1 Is the facility located on Indian Land? c co ❑Yes ❑✓ No EPA Form 3510-1(revised 3-19) Page 2 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 SECTION 6.EXISTING ENVIRONMENTAL PERMITS(40 CFR 122.21(f)(6)) 6.1 Existing Environmental Permits(check all that apply and print or type the corresponding permit number for each) m NPDES(discharges to surface LZI RCRA(hazardous wastes) ❑ UIC(underground injection of water) fluids) y NCG210168 NCD000813659 w a ❑✓ PSD(air emissions) ElNonattainment program(CAA) ❑✓ NESHAPs(CAA) NC0000003709600058 NC0000003709600058 ❑ Ocean dumping(MPRSA) ❑ Dredge or fill(CWA Section 404) ❑✓ Other(specify) WQ0003380 SECTION 7.MAP(40 CFR 122.21(f)(7)) 7.1 Have you attached a topographic map containing all required information to this application?(See instructions for Co specific requirements.) ❑✓ Yes ❑ No ❑ CAFO—Not Applicable(See requirements in Form 2B.) SECTION 8.NATURE OF BUSINESS(40 CFR 122.21(f)(8)) 8.1 Describe the nature of your business. Plywood manufacturing co N 61 .U) 7 co O 1p SECTION 9.COOLING WATER INTAKE STRUCTURES(40 CFR 122.21(f)(9)) 9.1 Does your facility use cooling water? ❑ Yes ❑✓ No 4 SKIP to Item 10.1. .3 9.2 Identify the source of cooling water.(Note that facilities that use a cooling water intake structure as described at a ' 40 CFR 125,Subparts I and J may have additional application requirements at 40 CFR 122.21(r).Consult with your c NPDES permitting authority to determine what specific information needs to be submitted and when.) 43 O O cp U SECTION 10.VARIANCE REQUESTS(40 CFR 122.21(f)(10)) 10.1 Do you intend to request or renew one or more of the variances authorized at 40 CFR 122.21(m)?(Check all that apply.Consult with your NPDES permitting authority to determine what information needs to be submitted and when.) d ❑ Fundamentally different factors(CWA ❑ Water quality related effluent limitations(CWA Section Section 301(n)) 302(b)(2)) CD ❑ Non-conventional pollutants(CWA ❑ Thermal discharges(CWA Section 316(a)) co Section 301(c)and(g)) ❑✓ Not applicable EPA Form 3510-1(revised 3-19) Page 3 ti Ii EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 SECTION 11.CHECKLIST AND CERTIFICATION STATEMENT(40 CFR 122.22(a)and(d)) 11.1 In Column 1 below,mark the sections of Form 1 that you have completed and are submitting with your application. For each section,specify in Column 2 any attachments that you are enclosing to alert the permitting authority.Note that not all applicants are required to provide attachments. Column 1 Column 2 ❑✓ Section 1:Activities Requiring an NPDES Permit ❑ wl attachments ❑✓ Section 2:Name,Mailing Address,and Location ❑ wl attachments ❑✓ Section 3:SIC Codes ❑ wl attachments ❑✓ Section 4:Operator Information ❑ wl attachments ❑✓ Section 5:Indian Land ❑ wl attachments ❑✓ Section 6:Existing Environmental Permits ❑ wl attachments CD w/topographic ❑✓ Section 7:Map ❑✓ map ❑ w/additional attachments o ❑✓ Section 8:Nature of Business ❑ w/attachments ❑✓ Section 9:Cooling Water Intake Structures ❑ w/attachments �' ❑✓ Section 10:Variance Requests ❑ wl attachments ❑✓ Section 11:Checklist and Certification Statement ❑ wl attachments d 11.2 Certification Statement U I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name(print or type first and last name) Official title Signature Date signed 11401 2-1-- EPA Form 3510-1(revised 3-19) Page 4 • EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 U.S.Environmental Protection Agency Form Application for NPDES Permit to Discharge Wastewater NPDES vIEPA NEW MANUFACTURING,COMMERCIAL,MINING,AND SILVICULTURAL OPERATIONS THAT HAVE NOT YET COMMENCED DISCHARGE OF PROCESS WASTEWATER SECTION 1.EXPECTED OUTFALL LOCATION(40 CFR 122.21(k)(1)) 1.1 Provide information on each of the facility's outfalls in the table below. c Outfall Receiving Water Latitude Longitude Number Name CO 0 0 001 Brooks Swamp 35° 15' 36" 78° 02' 117" R ° , „ ° , II ° ° , II SECTION 2.EXPECTED DISCHARGE DATE(40 CFR 122.21(k)(2)) 0 cu 2.1 Month Day Year U co N a N o 12 15 2022 w o SECTION 3.AVERAGE FLOWS AND TREATMENT(40 CFR 122.21(k)(3)(i)) 3.1 For each outfall identified under Item 1.1,provide average flow and treatment information.Add additional sheets as necessary. **Outfall Number** 001 Operations Contributing to Flow Operation Average Flow Wet Deck 0.979 mgd Stormwater 0.203 mgd c' mgd 1,-'0 mgd 1— mgd 3 o Treatment Units Li 0. Description Code from Final Disposal of Solid or Liquid (o (include size,flow rate through each treatment unit, Exhibit 2D 1 Wastes Other Than by Discharge aretention time,etc.) 284,000 cubic foot retention pond(53.2 hr retention) 1-U Land Apply Screens 1-T Boiler Fuel EPA Form 3510-2D(Revised 3-19) Page 1 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 3.1 "Outfall Number" Cont. Operations Contributing to Flow Operation Average Flow mgd mgd mgd mgd mgd Description Code from Final Disposal of Solid or Liquid (include size,flow rate through each treatment unit, Exhibit 2D-1 Wastes Other Than by Discharge retention time,etc.) -0 d 0 U w.. C i l0 N H CO **Outfall Number** 0 Operations Contributing to Flow u- Operation Average Flow 0 mgd 0 mgd mgd mgd mgd Description Code from Final Disposal of Solid or Liquid (include size,flow rate through each treatment unit, Exhibit 2D-1 Wastes Other Than by Discharge retention time,etc.) EPA Form 3510-2D(Revised 3-19) Page 2 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 SECTION 4.LINE DRAWING(40 CFR 122.21(k)(3)(ii)) rn 4.1 Have you attached a line drawing to this application that shows the water flow through your facility with a water 0.3 c 3 balance?(See instructions for drawing requirements. See Exhibit 2D-2 at end of instructions for example.) J 0Ei ❑✓ Yes ElNo SECTION 5.INTERMITTENT OR SEASONAL FLOWS(40 CFR 122.21(k)(3)(iii)) 5.1 Except for stormwater runoff,leaks,or spills,are any expected discharges described in Sections 1 and 3 intermittent or seasonal? ❑ Yes ✓❑ No 4 SKIP to Section 6. 5.2 Provide information on intermittent or seasonal flows for each applicable outfall.Attach additional pages,if necessary. Outfall Operations Fre uency Rate and Volume Number (list) Average Average Maximum Daily Maximum Total Duration Days/Week Months/Year Discharge Volume days/week months/year mgd gallons days o days/week months/year mgd gallons days - ri c days/week months/year mgd gallons days 0 d Frequency Rate and Volume Cl) Outfall Operations Average Average Maximum Daily Maximum Total Duration o Number (list) Days/Week Months/Year Discharge Volume C p days/week months/year mgd gallons days E c days/week months/year mgd gallons days days/week months/year mgd gallons days Outfall Operations Frequency Rate and Volume Number (list) Average Average Maximum Daily Maximum Total Duration Days/Week Months/Year Discharge Volume days/week months/year mgd gallons days days/week months/year mgd gallons days days/week months/year mgd gallons days SECTION 6.PRODUCTION(40 CFR 122.21(k)(4)) 6.1 Do any effluent limitation guidelines(ELGs)promulgated by EPA under CWA Section 304 apply to your facility? ❑✓ Yes 0 No-3 SKIP to Section 7. 6.2 Provide the following information on applicable ELGs. 0 �.. ELG Category ELG Subcategory Regulatory Citation 0 2 2 Timber Products Processing Subpart I,Wet Storage 40 CFR 29 a_ EPA Form 3510-2D(Revised 3-19) Page 3 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 OMB No.2040-0004 110000349855 NC0090051 Georgia-Pacific Dudley Plywood 6.3 Are the limitations in the applicable ELGs expressed in terms of production(or other measure of operation)? ❑ Yes ❑✓ No 4 SKIP to Section 7. 6.4 Provide an expected measure of average daily production expressed in terms and units of applicable ELGs. Expected Actual Average Daily Production for First Three Years Outfall Quantity per Day Unit of Measure Number Year Operation,Product,or Material (note basis if applicable) Year 1 Year 2 N Year 3 U 0 Year 1 -a 0 a Year 2 Year 3 Year 1 Year 2 Year 3 SECTION 7.EFFLUENT CHARACTERISTICS(40 CFR 122.21(k)(5)) See the instructions to determine the parameters and pollutants you are required to monitor and,in turn,the tables you must complete.Note that not all applicants need to complete each table. Table A.Conventional and Non-Conventional Parameters 7.1 Are you requesting a waiver from your NPDES permitting authority for one or more of the Table A parameters for any of your outfalls? ❑ Yes ✓❑ No 4 SKIP to Item 7.3. 7.2 If yes,indicate the applicable outfalls below.Attach waiver request and other required information to the application. Outfall number Outfall number Outfall number 53 7.3 Have you have provided estimates or actual data for all Table A parameters for each of your outfalls for which a waiver has not been requested and attached the results to this application package? No;a waiver has been requested from my co ❑✓ Yes ❑ NPDES permitting authority for all parameters at all outfalls. Table B.Certain Conventional and Non-Conventional Pollutants 7.4 Have you checked"Believed Present"for all pollutants listed in Table B that are limited directly or indirectly by an applicable ELG? ❑✓ Yes ❑ No 7.5 Have you checked"Believed Present"or"Believed Absent"for all remaining pollutants listed in Table B? ❑✓ Yes ❑ No 7.6 Have you provided estimated data for those Table B pollutants for which you have indicated are"Believed Present" in your discharge? ❑✓ Yes ❑ No EPA Form 3510-2D(Revised 3-19) Page 4 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 Table C.Toxic Metals,Total Cyanide,and Total Phenols 7,7 Have you indicated whether pollutants are"Believed Present"or"Believed Absent"for all pollutants listed on Table C for all outfalls? ❑✓ Yes ❑ No 7.8 Have you completed Table C by providing estimated data for pollutants you indicated are"Believed Present," including the source of the information,for each applicable outfall? ❑✓ Yes ❑ No Table D.Organic Toxic Pollutants(GCIMS Fractions) 7.9 Do you qualify for a small business exemption under the criteria specified in the Instructions? ❑ Yes 4 Note that you qualify at the top of ❑ No Table D,then SKIP to Item 7.12. 7.10 Have you indicated whether pollutants are"Believed Present"or"Believed Absent"for all pollutants listed on Table D for all outfalls? © Yes ❑ No 0 0 7.11 Have you completed Table D by providing estimated data for pollutants you indicated are"Believed Present," including the source of the information,for each applicable outfall? 7-7 © Yes ❑ No 2,3,7,8-Tetrachlorodibenzo-p-Dioxin(TCDD) co 7.12 Does the facility use or manufacture one or more of the 2,3,7,8-TCDD congeners listed in the Instructions,or do you know or have reason to believe that TCDD is or may be present in effluent from any of your outfalls? ai ❑ Yes ❑✓ No Table E.Certain Hazardous Substances and Asbestos 7.13 Have you indicated whether pollutants are"Believed Present"or"Believed Absent"for all pollutants listed in Table E for all outfalls? © Yes ❑ No 7.14 Have you completed Table E by reporting the reason the pollutants are expected to be present and available quantitative data for pollutants you indicated are"Believed Present"for each applicable outfall? ❑✓ Yes ❑ No Intake Credits,Tables A through E 7.15 Are you applying for net credits for the presence of any of the pollutants on Tables A through E for any of your outfalls? ❑ Yes 4 Consult with your NPDES permitting © No authorit . SECTION 8.ENGINEERING REPORT(40 CFR 122.21(k)(6)) 8.1 Do you have any technical evaluations of your wastewater treatment,including engineering reports or pilot plant studies? 0 ElYes ❑✓ No 4 SKIP to Item 8.3. 0. a, 8.2 Have you provided the technical evaluation and all related documents to this application package? a © Yes ❑ No 8.3 Are you aware of any existing plant(s)that resemble production processes,wastewater constituents,or wastewater w treatment at your facility? ❑✓ Yes ❑ No 4 SKIP to Section 9. EPA Form 3510-2D(Revised 3-19) Page 5 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 OMB No.2040-0004 110000349855 NC0090051 Georgia-Pacific Dudley Plywood 8.4 Provide the name and location of the similar plants. r O Name of Similar Plants Location of Similar Plants w• v C) Ashton Lewis Gatesville,NC I c ._ v.. w N C m o C O C W SECTION 9.OTHER INFORMATION(40 CFR 122.21(k)(7)) 9.1 Have you attached any optional information that you would like considered as part of the application review process (i.e.,material beyond that which you have already noted in the application as being attached)? ❑ Yes ❑✓ No 4 SKIP to Section 10. o 9.2 List the additional items and briefly note why you have included them. w co 1. 0 c 2. d s 3. 0 4. 5. SECTION 10.CHECKLIST AND CERTIFICATION STATEMENT(40 CFR 122.22(a)and(d)) 10.1 In Column 1 below,mark the sections of Form 2D that you have completed and are submitting with your application. For each section,specify in Column 2 any attachments that you are enclosing to alert the permitting authority.Note that not all applicants are required to complete all sections or tables,or provide attachments. Column 1 Column 2 ❑ Section 1: Expected Outfall 0 w/attachments(e.g.,responses for additional outfalls) I Location O Section 2:Expected ❑ w/attachments Discharge Date Section 3:Average Flows w/attachments c 0 and Treatment ❑ E ❑✓ Section 4:Line Drawing ❑ w/line drawing ❑ w/additional attachments co Section 5:Intermittent or 0 0 El w/attachments Seasonal Flows o 0 Section 6:Production ❑ wl attachments c w/Table A waiver c ❑ request or ❑✓ Table A .0 approval '., Section 7:Effluent ❑✓ Table B ❑✓ Table C -c 0 Characteristics 0 ❑✓ Table D ❑✓ Table E ❑ w/other attachments ❑✓ Section 8:Engineering ❑ w/technical evaluations and related attachments Report ❑✓ Section 9:Other Information 0 w/optional information ❑✓ Section 10:Checklist and ❑ w/attachments Certification Statement EPA Form 3510-2D(Revised 3-19) Page 6 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 10.2 Certification Statement v I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.Based on my inquiry of the person or persons who manage the system,or those persons w -a directly responsible for gathering the information,the information submitted is, to the best of my knowledge and belief,true,accurate,and complete. lam aware that there are significant penalties for submitting false information, cincluding the possibility of fine and imprisonment for knowing violations. a 0 Name(print or type first and last name) Official title tksoc k 4 Signature Date signed It\2$t?°- EPA Form 3510-2D(Revised 3-19) Page 7 This page intentionally left blank. EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE A.CONVENTIONAL AND NON CONVENTIONAL PARAMETER ESTIMATES(40 CFR 122.21(k)(5)(i))1 Effluent Data Intake Water Waiver Units Maximum Daily Average Daily Believed Present? Pollutant Requested Source of Information (if applicable) Discharge Discharge (use codes in instructions) (check only one response per (required) (if available) parameter) D Check here if you have applied to your NPDES authority for a waiver for all of the pollutants listed on this table for the noted outfall. 1. Biochemical oxygen ❑ Concentration mg/I 100 4 ❑✓ Yes 0 No demand(BOD5) Mass 2 Chemical oxygen demand 0 Concentration mg/I 120 4 ❑✓ Yes 0 No (COD) Mass 3 Total organic carbon 0 Concentration mg/I 50 4 ❑✓ Yes 0 No (TOC) Mass Concentration mg/I 36 4 4. Total suspended solids ❑ ❑✓ Yes 0 No (TSS) Mass Concentration 5. Ammonia(as N) 0 ❑ Yes ❑✓ No Mass 6. Flow 0 Rate mgd 0.576 4 ❑✓ Yes 0 No Temperature(winter) 0 °C °C 60 4 7. ❑✓ Yes ❑ No Temperature(summer) 0 °C °C 90 4 pH(minimum) ❑ Standard units s.u. 6 4 8. ❑✓ Yes ❑ No pH(maximum) ❑ Standard units S.U. 9 4 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e., methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2D(Revised 3-19) Page 1 This page intentionally left blank. EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE B.CERTAIN CONVENTIONAL AND NON CONVENTIONAL POLLUTANTS(40 CFR 122.21(k)(5)(ii))1 Presence or Absence Estimated Data for Pollutants Expected to be Present or Limited by an ELG (check one) (Provide both concentration and mass estimates for each pollutant.) Effluent Intake Water Pollutant Believed Believed Maximum Daily Average Daily Source of Information Believed Present? Present Absent Units Discharge Discharge (use codes in instructions) (check only one (required) (if available) response per item) ❑ Check(✓)here if you believe all pollutants listed to be absent from the discharge.You need not complete Table B for the noted outfall unless you have quantitative data available. 1 Bromide 0 0 Concentration 0 Yes 0 No (24959-67-9) Mass 2 Chlorine,total 0 El Concentration ❑ Yes ✓❑ No residual Mass Concentration 3. Color 0 ❑✓ 0 Yes ✓❑ No Mass Concentration 4. Fecal coliform 0 ❑✓ 0 Yes 0 No Mass Fluoride Concentration 5 El 0 0 Yes ✓❑ No (16984-48-8) Mass Concentration 6. Nitrate-nitrite ❑ ❑✓ 0 Yes 0 No Mass 7 Nitrogen,total ❑ ❑ Concentration ❑ Yes 0 No organic(as N) Mass Concentration mg/I 5 p 8. Oil and grease ❑✓ 0 0 Yes ✓❑ No Mass 9 Phosphorus(as P), 0 ❑ Concentration 0 Yes ✓❑ No total(7723-14-0) Mass 10. Sulfate(as SO4) 0 0 Concentration El Yes El No (14808-79-8) Mass Concentration 11. Sulfide(as S) 0 0 0 Yes ✓❑ No Mass EPA Form 3510-2D(Revised 3-19) Page 3 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE B.CERTAIN CONVENTIONAL AND NON CONVENTIONAL POLLUTANTS(40 CFR 122.21(k)(5)(ii))1 Presence or Absence Estimated Data for Pollutants Expected to be Present or Limited by an ELG (check one) (Provide both concentration and mass estimates for each pollutant.) Effluent Intake Water Pollutant Believed Believed Maximum Daily Average DailyBelieved Present? Present Absent Units DischargeDischargeSource of Information (check only one (use codes in instructions) (required) (if available) response per item) 12. Sulfite(as S03) 0 0 Concentration ❑Yes El No (14265-45-3) Mass Concentration 13. Surfactants 0 ❑✓ ❑Yes ❑No Mass 14, Aluminum,total 0 ❑✓ Concentration ❑Yes CD No (7429-90-5) Mass 15. Barium,total ❑ ❑✓ Concentration x (7440-39-3) Mass ❑Yes ❑No 16. Boron,total ❑ ❑✓ Concentration ❑Yes El No (7440-42-8) Mass 17 Cobalt,total 0 ❑✓ Concentration ❑Yes ONo (7440-48-4) Mass 18 Iron,total 0 ❑✓ Concentration ❑Yes ElNo (7439-89-6) Mass 19 Magnesium,total 0 ❑✓ Concentration ❑Yes El No (7439-95-4) Mass 20 Molybdenum,total 0 ❑✓ Concentration ❑Yes ONo (7439-98-7) Mass 21 Manganese,total ❑ ❑✓ Concentration Ekes El No (7439-96-5) Mass 22 Tin,total 0 ❑✓ Concentration ❑Yes El No (7440-31-5) Mass EPA Form 3510-2D(Revised 3-19) Page 4 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 i' Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE B.CERTAIN CONVENTIONAL AND NON CONVENTIONAL POLLUTANTS(40 CFR 122.21(k)(5)(ii))1 Presence or Absence Estimated Data for Pollutants Expected to be Present or Limited by an ELG (check one) (Provide both concentration and mass estimates for each pollutant) Effluent Intake Water Pollutant Believed Believed Maximum Daily Average DailyBelieved Present? Present Absent Units Discharge Discharge Source of Information (check only one (use codes in instructions) item response(required) (if available) res P per ) Titanium,total Concentration 23' (7440 32 6) 0 0 ❑Yes El No Mass 24. Radioactivity Concentration 24.1 Alpha,total ❑ 0 ❑Yes 0No Mass 24.2 Beta,total ❑ ❑ Concentration ❑Yes ElNo Mass Concentration 24.3. Radium,total 0 0 ❑Yes El No Mass 24.4 Radium 226,total ❑Concentration DYes El No 1 Mass Sampllf g shaft De connoted ccoroing to ufllcfenu sensitive test procecinrBs(I.e., methOo )approved under 40 CFK 136 for'he analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2D(Revised 3-19) Page 5 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 OMB No.2040-0004 110000349855 Georgia-Pacific Dudley Plywood 001 TABLE C.TOXIC METALS,TOTAL CYANIDE,AND TOTAL PHENOLS(40 CFR 122.21(k)(5)(iii)(A))1 Presence or Absence Estimated Data for Pollutants Expected to be Present in Discharge (check one) (Provide both concentration and mass estimates for each pollutant.) Effluent Intake Water Pollutant Maximum Average (CAS Number,if available) Believed Believed Believed Present? Present Absent Units Daily Daily Source of Information (Check only one Discharge Discharge (Use codes in Instructions.) response per pollutant.) (required) (if available) ❑ Check(,7)here if you believe all pollutants listed to be absent from the discharge.You need not complete Table C for the noted outfall unless you have quantitative data available. 1. Antimony,Total Concentration X (7440 36 0) ❑ ❑✓ Mass ❑ Yes No 2. Arsenic,Total ❑ ❑✓ Concentration ❑ Yes LINo (7440-38-2) Mass 3. Beryllium,Total ❑ ❑✓ Concentration ❑ Yes El No (7440-41-7) Mass 4. Cadmium,Total ❑ ✓❑ Concentration ❑ Yes ONo (7440-43-9) Mass 5. Chromium,Total Concentration (7440-47-3) ❑ Mass El Yes ❑No 6. Copper,Total Concentration ❑No (7440-50-8) ❑ El Mass ❑ Yes 7. Lead,Total Concentration 0 No (7439-92-1) ❑ Mass ❑ Yes 8. Mercury,Total Concentration X (7439-97-6) ❑ El Mass El No 9. Nickel,Total Concentration (7440-02-0) ❑ ❑ Mass ❑ Yes ❑No 10. Selenium,Total Concentration (7782-49-2) El ❑ Mass ❑ Yes El No 11. Silver,Total Concentration X (7440-22-4) ❑ El Mass ❑ Yes No 12. Thallium,Total Concentration x (7440 28 0) El ❑✓ Mass ❑ Yes No 13. Zinc,Total 0 El Concentration ❑ Yes 0 No (7440-66-6) Mass 14. Cyanide,Total ❑ ❑✓ Concentration ❑ Yes ONo (57-12-5) Mass 15. Phenols,Total 0 ❑✓ Concentration ❑ Yes El No Mass 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e., methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0.See Instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2D(Revised 3-19) Page 7 This page intentionally left blank. � 1 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 OMB No.2040-0004 110000349855 Georgia-Pacific Dudley Plywood 001 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas ChromatographylMass Spectrometry or GCIMS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Units Maximum Average Source of Believed Present? Present Absent Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) ❑✓ Check here if all pollutants listed in Table D are expected to be absent from your facility's discharge. ❑ Check here if the facility believes it is exempt from Table D reporting requirements because it is a qualified small business.See the instructions for exemption criteria and for a list of materials you must attach to the application. Note: If you check either of the above boxes,you do not need to complete Table D for the noted outfall unless you have quantitative data available. 1.Organic Toxic Pollutants(GC/MS Fraction—Volatile Compounds) 1.1 Acrolein ❑ I ❑ Concentration El Yes ❑✓ No (107 02 8) Mass 1.2 Acrylonitrile 0 0 Concentration ❑ Yes 0 No (107 13 1) Mass 1.3 Benzene 0 ❑ Concentration El Yes ❑✓ No (71 43 2) Mass 1.4 Bromoform 0 ❑ Concentration El Yes 0 No (75 25 2) Mass 1.5 Carbon tetrachloride ❑ ❑ Concentration ❑ Yes 0 No (56 23 5) Mass 1.6 Chlorobenzene El ❑ Concentration ❑ Yes 0 No (108 90 7) Mass 1.7 Chlorodibromomethane 0 El Concentration ❑ Yes ❑✓ No (124 48 1) Mass 1.8 Chloroethane 0 ❑ Concentration El Yes ❑✓ No (75 00 3) Mass 1.9 2-chloroethylvinyl ether 0 Concentration El Yes 0 No (110 75 8) Mass 1.10 Chloroform(67-66-3) ElConcentration El El Yes ❑✓ No Mass 1.11 Dichlorobromomethane 0 Concentration El Yes 0 No (75 27 4) Mass EPA Form 3510-2D(Revised 3-19) Page 9 ` EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 , 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas ChromatographylMass Spectrometry or GCIMS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Maximum Average Source of Believed Present? Present Absent Units Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 1.12 1,1-dichloroethane Concentration (75-34-3) 0 ❑✓ 0 Yes ❑✓ No Mass 1.13 1,2-dichloroethane Concentration (107-06-2) 0 ❑✓ 0 Yes ❑✓ No Mass 1.14 1,1-dichloroethylene Concentration (75-35-4) 0 0 0 Yes 0 No Mass 1.15 1,2-dichloropropane El ❑ Concentration ❑ Yes ❑✓ No (78 87 5) Mass 1.16 1,3-dichloropropylene 0 ❑ Concentration ❑ Yes ❑✓ No (542 75 6) Mass 1.17 Ethylbenzene 0 El El❑ Yes ❑✓ No (100-41-4) Mass 1.18 Methyl bromide El ❑ Concentration ❑ Yes 0 No (74 83 9) Mass 1.19 Methyl chloride 0 0 Concentration ❑ Yes ❑✓ No (74 87 3) Mass 1.20 Methylene chloride 0 ❑ Concentration ❑ Yes ❑✓ No (75 09 2) Mass 1.21 1,1,2,2-tetrachloroethane ❑ El El ❑ Yes 0 No (79 34 5) Mass 1.22 Tetrachloroethylene ❑ ❑✓ Concentration ❑ Yes 0 No (127-18 4) Mass 1.23 Toluene ❑ ❑ Concentration El Yes 0 No (108 88 3) Mass 1.24 1,2-trans-dichloroethylene ❑ 0 Concentration ❑ Yes El No (156-60-5) Mass EPA Form 3510-2D(Revised 3-19) Page 10 EPA Identification Number Facility Name I Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood ! 001 OMB No.2040-0004 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas Chromatography/Mass Spectrometry or GCIMS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Maximum Average Source of Believed Present? Present Absent Units Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 1.25 1,1,1-trichloroethane ❑ 0 Concentration ❑ Yes ❑✓ No (71 55 6) i Mass 1.26 1,1,2-trichloroethane El ❑ Concentration ❑ Yes 2 No (79 00 5) Mass 1.27 Trichloroethylene 0 El Concentration ❑ Yes 0 No (79 01 6) Mass 1.28 Vinyl chloride 0 0 Concentration ❑ Yes 2 No (75 01 4) Mass 2.Organic Toxic Pollutants(GC/MS Fraction—Acid Compounds) 2.1 2-chlorophenol 0 ❑ Concentration El Yes 2 No (95 57 8) Mass 2.2 2,4-dichlorophenol 0 El Concentration ❑ Yes ❑✓ No (120 83 2) Mass 2.3 2,4-dimethylphenol 0 ❑ Concentration ❑ Yes 2 No (105 67 9) Mass 2.4 4,6-dinitro-o-cresol El ❑ Concentration ❑ Yes 2 No (534 52 1) Mass 2.5 2,4-dinitrophenol 0 ❑ Concentration ❑ Yes 2 No (51 28 5) Mass 2.6 2-nitrophenol El Concentration El Yes ❑✓ No (88 75 5) Mass 2.7 4-nitrophenol ❑ ❑ Concentration ❑ Yes ❑✓ No (100-02-7) Mass 2.8 p-chloro-m-cresol El ❑ Concentration ❑ Yes 2 No (59 50 7) Mass 2.9 Pentachlorophenol 0 ❑ Concentration ❑ Yes 2 No (87 86 5) Mass EPA Form 3510-2D(Revised 3-19) Page 11 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas ChromatographylMass Spectrometry or GUMS Fractions)(40 CFR 122.21(k)(5)(iii)(B)p Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Maximum Average Source of Believed Present? Present Absent Units Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 2.10 Phenol 0 El Concentration ❑ Yes 0 No (108 95 2) Mass 2.11 2,4,6-trichlorophenol 0 0 Concentration ❑ Yes 2 No (88 05 2) Mass 3.Organic Toxic Pollutants(GC/MS Fraction—Base/Neutral Compounds) 3.1 Acenaphthene ❑ El Concentration ❑ Yes 0 No (83 32 9) Mass 3.2 Acenaphthylene 0 ❑ Concentration ❑ Yes 2 No (208 96 8) Mass 3.3 Anthracene 0 0 Concentration ❑ Yes El No (120 12 7) Mass 3.4 Benzidine 0 0 Concentration ❑ Yes ❑✓ No (92-87-5) Mass 3.5 Benzo(a)anthracene ❑ 0 Concentration ❑ Yes 0 No (56 55 3) Mass 3.6 Benzo(a)pyrene 0 0 Concentration ❑ Yes 2 No (50-32-8) Mass 3.7 3,4-benzofluoranthene 0 0 Concentration ❑ Yes 2 No (205 99 2) Mass 3.8 Benzo(ghi)perylene 0 0 Yes Concentration ❑ ❑ No (191-24-2) Mass 3.9 Benzo(k)fluoranthene 0 ❑ Concentration ❑ Yes 2 No (207 08 9) Mass 3.10 Bis(2-chloroethoxy)methane 0 ❑ Concentration ❑ Yes ❑✓ No (111-91-1) Mass 3.11 Bis(2-chloroethyl)ether 0 El Concentration El Yes 2 No (111 44 4) Mass EPA Form 3510-2D(Revised 3-19) Page 12 £1 abed (6-E pasha°)aZ-019£WJod Vd3 oN ❑ SB,k ❑ sseW 0 ❑ (£-��-i.£i) uo!;e.IWaouo3 a;eleq;qd!Aq;aw!a 5Z•£ oN ❑ s9A ❑ son ❑ ❑ (Z-99178) uo!;eJ;ueouo3 eTeleq;gd IAq;a!a iZ•E ON ❑ saA ❑ sseW ❑ El (V 6-66) uoRaqueouoO eu!p!zuegao!go!p-£'E £Z•£ oN 0 seA ❑ sseW ❑� El (L-917-906) uo!;eJ;ueouo3 euezuegaolgo!p-j' I. ZZ•£ oN 0 SaA ❑ sseW ❑ El (6-£L-6ti9) uo!;eJ;ueouo3 euezuegaolgo!p-£'6 6Z•£ 0 0 sseW (6-05-56) ONsaduo!;a;ueouo3 ❑ ❑ euezuegaoigo!p-VI. ON ON 0 SOA 0 sseW 0 uo!;ei;ueouo3 eueowt ue(q`e)ozueq!d 6vE sseW (6-60-86Z) ON 0 sad ❑ uogej;ueouo0 0 Eleuestig3 8V£ sseW (£-ZL-5001) ON ❑ sad ❑ uo!;e�;uaouo0 0 0 aaq;a!Auegd IAuagdao!go-ti Ll•£ sseW (L-85-66) ON ❑ SOA ❑ uo!;equeouoO ❑ 0 eue!eq;gdeuao!go-Z 9VE 0 ❑ El ❑ (L-89-92) sseW ONsad uo!;eW;ueouoO eleleq;qd!p(zueq Iona 56•£ sseW (£-55-601) ON 0 sad ❑ uo!;eJ;ueouoo El 0 aaq;a lAuegd!Auegdowwq-p y1,•E sseW (L-68-Li.I.)oN ❑ sad ❑ uo!;eW;uaouoO ❑ ❑ a;eleq;gd(li(xa llAgle-Z)s!8 E6.£ ON ❑ seA 0 mini El ❑ (1-08-ZOI•) uogew;ueouo0 aaq;a(!Adoidos!oaolgo-Z)s!8 Z6•E (lueanpod (suogon.gsul u!sapoo asn) a6iegos!a aNegas!Q Jed asuodsaJ auo Akio)ioago) uogewJo;u! 411e0 /ll!ea ;uesgy ;uasad 4,;ueseid pana!la8 ;o°linos e6eaany wnw!xeW s}!u8 paneues panties (algeliene}I'JaquinN SHO) is;eM ame;ul ;uenl 3 ;ue;nllad (lueanllod goea Jo;saaewgsa ssew pue uogeilueouoo yaoq ap!Awd) (auo)ioego) a6.1egos!Q u!;uasaad ea o;pe;oadx9 s;ue;nllod Jo}Ma pa;ewgs3 aouesgy Jo aauasaJd ((s)(!!!)(s)01)1 Z'ZZI 21d3 ob)(suo!;ae.1d SVI139 ao itqatuomeds ssemAgdeJ6o;ewom see)SiNdllllOd 31X0l 3110'O210'a 318V1 17000 OtiOZ'oN 8W0 i0O poomAld AaipnG of;toed-elaaoag SS86b£0000II 61150/£0 penoiddy WJod JagwnN IIeAnO I aweN AlFed iequmN uogeoyyuapI Vd3 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 • 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas ChromatographylMass Spectrometry or GCIMS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Maximum Average Source of Believed Present? Present Absent Units Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 3.26 Di-n-butyl phthalate El ❑ Concentration El Yes ❑✓ No (84 74 2) Mass 3.27 2,4-dinitrotoluene 0 0 Concentration ❑ Yes 0 No (121 14 2) Mass 3.28 2,6-dinitrotoluene ❑ El El❑ Yes 0 No (606 20 2) Mass 3.29 Di-n-octyl phthalate 0 0 Concentration ❑ Yes 0 No (117-84-0) Mass 3.30 1,2-diphenylhydrazine 0 0 Concentration ❑ Yes 0 No (as azobenzene)(122-66-7) Mass 3.31 Fluoranthene 0 ❑ Concentration ❑ Yes 0 No (206 44 0) Mass 3.32 Fluorene 0 ❑ Concentration ❑ Yes 0 No (86 73 7) Mass 3.33 Hexachlorobenzene 0 ❑ Concentration El Yes 0 No (118 74 1) Mass 3.34 Hexachlorobutadiene 0 El Concentration ❑ Yes ❑✓ No (87 68 3) Mass 3.35 Hexachlorocyclopentadiene 0 0 Concentration ❑ Yes 0 No (77-47-4) Mass 3.36 Hexachloroethane 0 El Concentration ❑ Yes ❑✓ No (67-72-1) Mass 3.37. Indeno(1,2,3-cd)pyrene 0 0 Concentration ❑ Yes 0 No (193 39 5) Mass 3.38 Isophorone 0 0 Concentration ❑ Yes 0 No (78-59-1) Mass 3.39 Naphthalene 0 0 Concentration ❑ Yes 0 No (91 20 3) Mass EPA Form 3510-2D(Revised 3-19) Page 14 t - EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 OMB No.2040-0004 110000349855 Georgia-Pacific Dudley Plywood 001 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas ChromatographylMass Spectrometry or GCIMS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Maximum Average Source of Believed Present? Present Absent Units Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 3.40 Nitrobenzene 0 0Concentration ❑ Yes ❑✓ No (98 95 3) Mass 3.41 N-nitrosodimethylamine 0 Concentration El Yes 0 No (62 75 9) Mass 3.42 N-nitrosodi-n-propylamine 0 Concentration El El Yes ❑✓ No (621 64 7) Mass 3.43 N-nitrosodiphenylamine 0 ❑ Concentration ❑ Yes 0 No (86 30 6) Mass 3.44 Phenanthrene 0 ❑ Concentration ❑ Yes 0 No (85 01 8) Mass 3.45 Pyrene 0 Concentration El El Yes 0 No (129 00 0) Mass 3.46 1,2,4-trichlorobenzene 0 ❑ Concentration ❑ Yes 0 No (120-82-1) Mass 4.Organic Toxic Pollutants(GCIMS Fraction—Pesticides) 4.1. Aldrin 0 ❑ Concentration ❑ Yes 0 No (309 00 2) Mass 4.2 a-BHC 0 Concentration ❑ Yes 0 No (319 84 6) Mass 4.3 13-BHC 0 Concentration ❑ Yes 0 No (319 85 7) Mass 4.4 y-BHC 0 Concentration El ❑ Yes 0 No (58 89 9) Mass 4.5 5-BHC El El Yes 0 No (319 86 8) Mass 4.6 Chlordane 0 ❑ Concentration ❑ Yes 0 No (57 74 9) Mass EPA Form 3510-2D(Revised 3-19) Page 15 ` EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 • 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 I TABLE D.ORGANIC TOXIC POLLUTANTS(Gas ChromatographylMass Spectrometry or GC/MS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Units Maximum Average Source of Believed Present? Present Absent Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 4.7 4,4'-DDT 0 0 Concentration ❑ Yes 0 No (50 29 3) Mass 4.8 4,4'-DDE 0 ❑ Concentration ❑ Yes ❑✓ No (72 55 9) Mass 4.9 4,4'-DDD 0 0 Concentration ❑ Yes ❑ No (72 54 8) Mass 4.10 Dieldrin ❑ El Concentration ❑ Yes El No (60 57 1) Mass 4.11 a-endosulfan Concentration (115-29-7) 0 ❑✓ ❑ Yes 0 No Mass 4.12 6-endosulfan Concentration (115-29-7) ❑ ❑✓ 0 Yes ❑ No Mass 4.13 Endosulfan sulfate Concentration (1031-07-8) 0 0 0 Yes 0 No Mass 4.14 Endrin Concentration (72-20-8) 0 ❑✓ ❑ Yes 0 No Mass 4.15 Endrin aldehyde Concentration (7421-93-4) ❑ 0 0 Yes 0 No Mass EPA Form 3510-2D(Revised 3-19) Page 16 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE D.ORGANIC TOXIC POLLUTANTS(Gas Chromatography/Mass Spectrometry or GC/MS Fractions)(40 CFR 122.21(k)(5)(iii)(B))1 Presence or Absence Estimated Data for Pollutants Expected to Be Present in Discharge (check one) (provide both concentration and mass estimates for each pollutant) Pollutant Effluent Intake Water (CAS Number,if available) Believed Believed Maximum Average Source of Believed Present? Present Absent Units Daily Daily Information (check only one response per Discharge Discharge (use codes in instructions) pollutant) 4.16 Heptachlor 0 0 Concentration ❑ Yes 0 No (76 44 8) Mass 4,17 Heptachlor epoxide 0 0 Concentration ❑ Yes ❑✓ No (1024 57 3) Mass 4.18 PCB-1242 ❑ El Concentration ❑ Yes ❑✓ No (53469 21 9) Mass 4.19 PCB-1254 0 0 Concentration El Yes 0 No (11097 69 1) Mass 4.20 PCB-1221 0 0 Concentration ❑ Yes 2 No (11104 28 2) Mass 4.21 PCB-1232 0 ❑ Concentration ❑ Yes ❑ No (11141 16 5) Mass 4.22 PCB-1248 0 ❑ Concentration ❑ Yes 0 No (12672 29 6) Mass 4.23 PCB-1260 0 ❑ Concentration ❑ Yes ❑✓ No (11096 82 5) Mass 4.24 PCB-1016 0 El Concentration ❑ Yes 0 No (12674 11 2) Mass 4.25 Toxaphene 0 0 Concentration ❑ Yes 0 No (8001 35 2) Mass 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e., methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2D(Revised 3-19) Page 17 , This page intentionally left blank. EPA Identification Number Facility Name Outfall Number I Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE E.CERTAIN HAZARDOUS SUBSTANCES AND ASBESTOS(40 CFR 122.21(k)(5)(v))1 Presence or Absence Pollutant (check one) Available Quantitative Data Believed Believed Reason Pollutant Believed Present in Discharge (specify units) Present Absent ❑✓ Check(✓)here if you believe all pollutants listed to be absent from the discharge.You need not complete Table E for the noted outfall unless you have quantitative data available. 1. Asbestos ❑ ❑✓ 2. Acetaldehyde 0 ✓❑ 3. Allyl alcohol 0 ❑✓ 4. Allyl chloride 0 0 5. Amyl acetate 0 ❑✓ 6. Aniline 0 ❑✓ 7. Benzonitrile 0 0 8. Benzyl chloride 0 ❑✓ 9. Butyl acetate 0 ❑✓ 10. Butylamine ❑ 0 11. Captan 0 ❑✓ 12. Carbaryl 0 ❑✓ 13. Carbofuran 0 ❑✓ 14. Carbon disulfide 0 0 15. Chlorpyrifos 0 0 16. Coumaphos 0 ❑✓ 17. Cresol 0 0 18. Crotonaldehyde ❑ 0 EPA Form 3510-2D(Revised 3-19) Page 19 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE E.CERTAIN HAZARDOUS SUBSTANCES AND ASBESTOS(40 CFR 122.21(k)(5)(v))1 Presence or Absence Pollutant (check one) Available Quantitative Data Believed Believed Reason Pollutant Believed Present in Discharge (specify units) Present Absent 19. Cyclohexane ❑ ✓❑ 20. 2,4-D(2,4-dichlorophenoxyacetic acid) El ❑✓ 21, Diazinon El ❑✓ 22. Dicamba El ❑✓ 23. Dichlobenil El ❑✓ 24. Dichlone 0 ❑✓ 25. 2,2-dichloropropionic acid 0 ❑✓ 26. Dichlorvos 0 ❑✓ 27. Diethyl amine ❑ ❑✓ 28. Dimethyl amine ❑ ✓❑ 29. Dintrobenzene El ❑✓ 30. Diquat El ❑✓ 31. Disulfoton El ❑✓ 32. Diuron El ❑✓ 33. Epichlorohydrin ❑ ❑✓ 34. Ethion El ❑✓ 35. Ethylene diamine 0 ❑✓ 36. Ethylene dibromide El 0 37. Formaldehyde 0 0 EPA Form 3510-2D(Revised 3-19) Page 20 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE E.CERTAIN HAZARDOUS SUBSTANCES AND ASBESTOS(40 CFR 122.21(k)(5)(v))l Presence or Absence Pollutant (check one) Reason Pollutant Believed Present in Discharge Available Quantitative Data Believed Believed (specify units) Present Absent 38. Furfural 0 0 39. Guthion 0 0 40. Isoprene ❑ 0 41. Isopropanolamine 0 0 42. Kelthane ❑ 0 43. Kepone ❑ 0 44. Malathion 0 0 45. Mercaptodimethur 0 0 46. Methoxychlor 0 0 47. Methyl mercaptan 0 0 48. Methyl methacrylate 0 0 49. Methyl parathion .0 12 50. Mevinphos 0 0 51. Mexacarbate 0 0 52. Monoethyl amine ❑ 0 53. Monomethyl amine ❑ 0 54. Naled 0 0 55. Naphthenic acid 0 0 56. Nitrotoluene 0 0 EPA Form 3510-2D(Revised 3-19) Page 21 I EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 L 110000349855 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 • TABLE E.CERTAIN HAZARDOUS SUBSTANCES AND ASBESTOS(40 CFR 122.21(k)(5)(v))1 Presence or Absence Pollutant (check one) Reason Pollutant Believed Present in Discharge Available Quantitative Data Believed Believed (specify units) Present Absent 57. Parathion ❑ ❑✓ 58. Phenolsulfonate ❑ ❑✓ 59. Phosgene ❑ ❑✓ 60. Propargite 0 ❑✓ 61. Propylene oxide 0 ❑✓ 62. Pyrethrins ❑ ❑✓ 63. Quinoline ❑ ❑✓ 64. Resorcinol ❑ ❑✓ 65. Strontium ❑ ❑✓ 66. Strychnine ❑ ❑✓ 67. Styrene ❑ ❑✓ 68. 2,4 5-T(2,4,5-trichlorophenoxyacetic ❑ ❑✓ acid) 69. TDE(tetrachlorodiphenyl ethane) 0 ❑✓ 70. 2,4,5-TP[2-(2,4,5-trichlorophenoxy) ❑ El propanoic acid] 71. Trichlorofon ❑ ❑✓ 72. Triethanolamine ❑ ✓❑ 73. Triethylamine ❑ ❑✓ . 74. Trimethylamine ❑ ❑✓ 75. Uranium ❑ ❑✓ EPA Form 3510-2D(Revised 3-19) Page 22 EPA Identification Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 ' Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE E.CERTAIN HAZARDOUS SUBSTANCES AND ASBESTOS(40 CFR 122.21(k)(5)(v))1 Presence or Absence Pollutant (check one) Reason Pollutant Believed Present in Discharge Available Quantitative Data Believed Believed (specify units) Present Absent 76. Vanadium ❑ 0 77. Vinyl acetate ❑ 0 78. Xylene 0 0 79. Xylenol ❑ 0 80. Zirconium ❑ 0 I Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2D(Revised 3-19) Page 23 • EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 Form U.S Environmental Protection Agency 2F ,oEPA Application for NPDES Permit to Discharge Wastewater NPDES STORMWATER DISCHARGES ASSOCIATED WITH INDUSTRIAL ACTIVITY SECTION 1.OUTFALL LOCATION(40 CFR 122.21(g)(1)) 1.1 Provide information on each of the facilit 's outfalls in the table below Outfall Receiving Water Name Latitude Longitude Number 001 Brooks Swamp 35° 15' 36" 78° 02' 117" 0 002 Brooks Swamp 35' 15 471' 78° 02' 16" 0 O J ° " 0 io 1 0 ° 11 SECTION 2.IMPROVEMENTS(40 CFR 122.21(g)(6)) 2.1 Are you presently required by any federal,state,or local authority to meet an implementation schedule for constructing, upgrading,or operating wastewater treatment equipment or practices or any other environmental programs that could affect the discharges described in this application? ❑ Yes ❑✓ No 4 SKIP to Section 3. 2.2 Briefly identify each applicable project in the table below. Final Compliance Dates Brief Identification and Affected Outfalls Source(s)of Discharge Description of Project (list outfall numbers) Required Projected E al O d E 2.3 Have you attached sheets describing any additional water pollution control programs(or other environmental projects that may affect your discharges)that you now have underway or planned?(Optional Item) ❑ Yes ❑ No EPA Form 3510-2F(Revised 3-19) Page 1 • • EPA Identification Number NPDES Permit Number Facility Name Form Approved 03105119 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 SECTION 3.SITE DRAINAGE MAP(40 CFR 122.26(c)(1)(i)(A)) 4 3.1 Have you attached a site drainage map containing at required information to this application?(See instructions for .0) CASspecific guidance.) Tsi to Yes ❑ No SECTION 4.POLLUTANT SOURCES(40 CFR 122.26(c)(1)(i)(B)) 4.1 Provide information on the facility's pollutant sources in the table below. Outfall Impervious Surface Area Total Surface Area Drained Number (within a mile radius of the facility) (within a mile radius of the facility) specify units specify units 001 56 acres acres specify units specify units 002 1.1 acres 10.7 acres specify units specify units specify units specify units specify units specify units specify units specify units 4.2 Provide a narrative description of the facility's significant material in the space below.(See instructions for content requirements.) Facility is wood products manufacturing facility that produces plywood. U) 3 0 0 d 4.3 Provide the location and a description of existing structural and non-structural control measures to reduce pollutants in stormwater runoff.(See instructions for specific guidance.) Stormwater Treatment Codes from Outfall Control Measures and Treatment Exhibit Number 2F-1 (list) 001 Settling Pond 1-U EPA Form 3510-2F(Revised 3-19) Page 2 1 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 SECTION 5.NON STORMWATER DISCHARGES(40 CFR 122.26(c)(1)(i)(C)) 5.1 I certify under penalty of law that the outfall(s) covered by this application have been tested or evaluated for the presence of non-stormwater discharges. Moreover, I certify that the ouffalls identified as having non-stormwater discharges are described in either an accompanying NPDES Form 2C,2D, or 2E application. Name(print or type first and last name) Official title, 1 .0-7 1& r ' Signature Date signed I I,zs81 g4- u, E) 5.2 Provide the testing in ormation requested in the table below. -c Onsite Drainage Points N Outfall Description of Testing Method Used Date(s)of Testing Directly Observed Number During Test ai 001 Visual 09/30/2022 Yes in z � SECTION 6.SIGNIFICANT LEAKS OR SPILLS(40 CFR 122.26(c)(1)(i)(D)) 6.1 Describe any significant leaks or spills of toxic or hazardous pollutants in the last three years. None Q U `o N co co J co co SECTION 7.DISCHARGE INFORMATION(40 CFR 122.26(c)(1)(i)(E)) See the instructions to determine the pollutants and parameters you are required to monitor and,in turn,the tables you must o complete. Not all applicants need to complete each table. 7.1 Is this a new source or new discharge? No 4 See instructions regarding submission of Yes See instructions regarding submission of g g ❑ estimated data. ❑ actual data. Tables A,B,C,and D 7.2 Have you completed Table A for each outfall? ❑✓ Yes ❑ No EPA Form 3510-2F(Revised 3-19) Page 3 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 7.3 Is the facility subject to an effluent limitation guideline(ELG)or effluent limitations in an NPDES permit for its process wastewater? ❑ Yes ✓❑ No+ SKIP to Item 7.5. 7.4 Have you completed Table B by providing quantitative data for those pollutants that are(1)limited either directly or indirectly in an ELG and/or(2)subject to effluent limitations in an NPDES permit for the facility's process wastewater? ❑ Yes ❑ No 7.5 Do you know or have reason to believe any pollutants in Exhibit 2F-2 are present in the discharge? ❑ Yes ❑✓ No 4 SKIP to Item 7.7. 7.6 Have you listed all pollutants in Exhibit 2F-2 that you know or have reason to believe are present in the discharge and provided quantitative data or an explanation for those pollutants in Table C? ❑ Yes ❑✓ No 7.7 Do you qualify for a small business exemption under the criteria specified in the Instructions? ❑ Yes +SKIP to Item 7.18. ❑✓ No 7.8 Do you know or have reason to believe any pollutants in Exhibit 2F-3 are present in the discharge? ❑ Yes ❑✓ No 4 SKIP to Item 7.10. 7.9 Have you listed all pollutants in Exhibit 2F-3 that you know or have reason to believe are present in the discharge in Table C? ❑✓ Yes ❑ No 0 7.10 Do you expect any of the pollutants in Exhibit 2F-3 to be discharged in concentrations of 10 ppb or greater? ❑ Yes ❑✓ No 4 SKIP to Item 7.12. 7.11 Have you provided quantitative data in Table C for those pollutants in Exhibit 2F-3 that you expect to be discharged in rn concentrations of 10 ppb or greater? co y ❑✓ Yes ElNo i3 7.12 Do you expect acrolein,acrylonitrile,2,4-dinitrophenol,or 2-methyl-4,6-dinitrophenol to be discharged in concentrations of 100 ppb or greater? ❑ Yes ❑✓ No 4 SKIP to Item 7.14. 7.13 Have you provided quantitative data in Table C for the pollutants identified in Item 7.12 that you expect to be discharged in concentrations of 100 ppb or greater? © Yes ❑ No 7.14 Have you provided quantitative data or an explanation in Table C for pollutants you expect to be present in the discharge at concentrations less than 10 ppb(or less than 100 ppb for the pollutants identified in Item 7.12)? ❑✓ Yes ❑ No 7.15 Do you know or have reason to believe any pollutants in Exhibit 2F-4 are present in the discharge? ❑ Yes © No 4 SKIP to Item 7.17. 7.16 Have you listed pollutants in Exhibit 2F-4 that you know or believe to be present in the discharge and provided an explanation in Table C? ❑ Yes ❑ No 7.17 Have you provided information for the storm event(s)sampled in Table D? ElYes ❑ No EPA Form 3510-2F(Revised 3-19) Page 4 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 Used or Manufactured Toxics 7.18 Is any pollutant listed on Exhibits 2F-2 through 2F-4 a substance or a component of a substance used or manufactured as an intermediate or final product or byproduct? ❑ Yes ❑✓ No 4 SKIP to Section 8. o 7.19 List the pollutants below,including TCDD if applicable. 1. 4. 7. CD 2. 5. 8. co 0 3. 6. 9. SECTION 8.BIOLOGICAL TOXICITY TESTING DATA(40 CFR 122.21(g)(11)) 8.1 Do you have any knowledge or reason to believe that any biological test for acute or chronic toxicity has been made on co any of your discharges or on a receiving water in relation to your discharge within the last three years? ca ❑ Yes ❑✓ No 4 SKIP to Section 9. 43 8.2 Identify the tests and their purposes below. Test(s) Purpose of Test(s) Submitted to NPDES Date Submitted Permitting Authority? 0 ~ ❑ Yes ❑ No _urn ❑ Yes ❑ No ❑ Yes ❑ No SECTION 9.CONTRACT ANALYSIS INFORMATION(40 CFR 122.21(g)(12)) 9.1 Were any of the analyses reported in Section 7(on Tables A through C)performed by a contract laboratory or consulting firm? ❑✓ Yes ❑ No 4 SKIP to Section 10. 9.2 Provide information for each contract laboratory or consulting firm below. Laboratory Number 1 Laboratory Number 2 Laboratory Number 3 Name of laboratory/firm Pace 0 E `o N Laboratory address 9800 Kincey Ave,Suite 100 T Huntersville,NC 28078 m o Phone number U (704)875-9092 Pollutant(s)analyzed TSS,COD,Oil and Grease EPA Form 3510-2F(Revised 3-19) Page 5 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood OMB No.2040-0004 SECTION 10.CHECKLIST AND CERTIFICATION STATEMENT(40 CFR 122.22(a)and(d)) 10.1 In Column 1 below,mark the sections of Form 2F that you have completed and are submitting with your application.For each section,specify in Column 2 any attachments that you are enclosing to alert the permitting authority.Note that not all applicants are required to complete all sections or provide attachments. Column 1 Column 2 ❑✓ Section 1 ❑ wl attachments(e.g.,responses for additional outfalls) ❑✓ Section 2 ❑ wl attachments ❑✓ Section 3 ❑ w/site drainage map ❑✓ Section 4 ❑ w/attachments ❑✓ Section 5 ❑ w/attachments • ✓❑ Section 6 ❑ wl attachments ❑✓ Section 7 ❑✓ Table A ❑ w/small business exemption request a ❑ Table B ❑ wl analytical results as an attachment ❑ Table C 0 Table D ❑✓ Section 8 ❑ w/attachments a y_ ID Section 9 ❑ w/attachments(e.g.,responses for additional contact laboratories or firms) 0 Section 10 ❑ 10.2 Certification Statement 1 certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name(print or type first and last name)n Official title (' LSo►•, W 1 'a't ` & Signature Date signed EPA Form 3510-2F(Revised 3-19) Page 6 EPA Identification Number NPDES Permit Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE A.CONVENTIONAL AND NON CONVENTIONAL PARAMETERS(40 CFR 122.26(c)(1)(i)(E)(3))1 You must provide the results of at least one analysis for every pollutant in this table. Complete one table for each outfall.See instructions for additional details and requirements. Maximum Daily Discharge Average Daily Discharge Source of (specify units) (specify units) Number of Storm Information Pollutant or Parameter Grab Sample Taken Flow-Weighted Grab Sample Taken Flow-Weighted Events Sampled (new source/new During First During First dischargers only;use 30 Minutes Composite 30 Minutes Composite ) codes in instructions 1. Oil and grease 5 4.9 7 2. Biochemical oxygen demand(BOD5) 3. Chemical oxygen demand(COD) 121 79 7 4. Total suspended solids(TSS) 19.6 118 7 5. Total phosphorus 6. Total Kjeldahl nitrogen(TKN) 7. Total nitrogen(as N) pH(minimum) 8. pH(maximum) 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F(Revised 3-19) Page 7 This page intentionally left blank. EPA Identification Number NPDES Permit Number Facility Name Outfall Number Form Approved 03/05/19 110000349855 NC0090051 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE B.CERTAIN CONVENTIONAL AND NON CONVENTIONAL POLLUTANTS(40 CFR 122.26(c)(1)(i)(E)(4)and 40 CFR 122.21(g)(7)(vi)(A))1 List each pollutant that is limited in an effluent limitation guideline(ELG)that the facility is subject to or any pollutant listed in the facility's NPDES permit for its process wastewater(if the facility is operating under an existing NPDES permit).Complete one table for each outfall.See the instructions for additional details and requirements. Maximum Daily Discharge Average Daily Discharge Source of (specify units) (specify units) Number of Storm Information Pollutant and CAS Number(if available) Grab Sample Taken Flow-Weighted Grab Sample Taken Flow-Weighted Events Sampled (new source/new During First During First dischargers only;use 30 Minutes Composite 30 Minutes Composite codes in instructions) 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F(Revised 3-19) Page 9 This page intentionally left blank. EPA Identification Number NPDES Permit Number Facility Name Outfall Number Form Approved 03/05/19 • 110000349855 NC0090051 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE C.TOXIC POLLUTANTS,CERTAIN HAZARDOUS SUBSTANCES,AND ASBESTOS(40 CFR 122.26(c)(1)(i)(E)(4)and 40 CFR 122.21(g)(7)(vi)(B)and(vii))1 List each pollutant shown in Exhibits 2F-2,2F-3,and 2F-4 that you know or have reason to believe is present.Complete one table for each outfall.See the instructions for additional details and requirements. Maximum Daily Discharge Average Daily Discharge Source of (specify units) (specify units) Number of Storm Information Pollutant and CAS Number(if available) Grab Sample Taken Grab Sample Taken (new source/new During First Flow-Weighted During First Flow-Weighted Events Sampled dischargers only;use 30 Minutes Composite 30 Minutes Composite codes in instructions) 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I,subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F(Revised 3-19) Page 11 This page intentionally left blank. . EPA Identification Number NPDES Permit Number Facility name Outfall Number Form Approved 03/05/19 ' 110000349855 NC0090051 Georgia-Pacific Dudley Plywood 001 OMB No.2040-0004 TABLE D.STORM EVENT INFORMATION(40 CFR 122.26(c)(1)(i)(E)(6)) Provide data for the storm event(s)that resulted in the maximum daily discharges for the flow-weighted composite sample. Number of Hours Between Duration of Storm Event Total Rainfall During Beginning of Storm Measured and Maximum Flow Rate Total Flow from Rain Event Date of Storm Event (in hours) Storm Event End of Previous Measurable Rain During Rain Event (in gallons or specify units) (in inches) Event (in gpm or specify units) Provide a description of the method of flow measurement or estimate. EPA Form 3510-2F(Revised 3-19) Page 13 APPENDIX 1 SITE MAP 1 M iL' • 1111111. Brooks Swamp • t ' Sit: Stream Class NSW Yii I A)1_ /( •. ' —�ji a } w 7s( 4 .,may .,� a ft 3 '�►e y J:' ,, ti .. . ...._ 4J — 1 1 1 . . • Or 1 , i jY �� o.k •• • ' Y ✓C +, .. � -'r�, . - _I- + - Ty Legend -) Outfall 001 - Coordinates 35.259962, -78.038021 GP Dudley Plywood ■ Proposed Wet Deck I. GP Site Map Appendix 1 -...—Stormwater Direction Georgia-Pacific1 APPENDIX 2 TOPOGRAPHIC MAP • ./ / .... • --/ 1' . I ,.2,,•:--:, f„._--,-,,-;.:..",.,,,!y4,•i.4-f‘.,,)1„i,y4f,,/'h,.%o'.-;',w‘\-_..-_,:-i.:\\t-,,-),-,_.._..-.r,1-:I.r-..../,A-'„j\,"„„:•.,.:=.:4-,1-:-.:..:.„C•,-.,•-_.-;.;,-,-.-r,--,.,.,..,!-_.,,•-.-,,.,,\‘_,'-z.•-i-;...',.••>-.'-.,_,-,z:‘.-./41,-..-,...i4„-'f":- --...ta41-..•-.-\-:...,t-_--_.s...-1.\.-!..,•.,._"_.\,_:..-:X.,.,7.,,-.J::..7ir.,.7.,_.„,1..,:...,.:t.,7-.:;--.:1,.-;‘-....4_.-.7..'*,_+1,-\1,.1...(,'--,-.„-,-.,...a.--)...•_(,,-t:.-_,--.:,.\7-.\._..'-_,_---_-_--.v--t-_,_--..._-i.,-..!,.•- ':•,i• 1.l''i p,'.l•c•• .-... '-"...-.„----1:.,',.'s.l-;-".•.4i,lIl"7-`,,r-:',4 t:i-1i3-!---)--i-.-r•,i;\i•i!iii,(,,_,_-_-, ,r,‘•„4„,.•..7.._.•J.v-••,-:.\:•!L,y\,4.',.5-.,',,,,.L ......'.-:',..5,:•-.'I i,..r..-..).:7,i,t-7 '•Lai!! ,I. rir.2.7) .c rri,;-");:(7,--- A---v---.. 1.../altt.....,v ',`,---i'le-)1 i-e7.-".t-.:7,,;,-;--:-_.-,-._.,:.Nt.,.„,,.-,\.‘v_.,.I.j.,_1,).',,/•/-/'-z--.-,./,s4„1-,:-.,,7,':\2-7-,-,c---•1-M.".'\,.,.,.'..-/'..\.•---.-..-,.1,‘‘.:..,,‘,...,.1...r'.-%-.,4-)_-.‘,,•_%/„.k'I)-..0t,"0.1.„•-i't,.'1,1•j1l'.-r,„',\,,,-,',,:.„,,.,.,,1•v\,;%,.!,,.•„„.'.-.,•_-,r•/-.:.--.._-.•-..-.._...-I_•-,?";I.-„:\•ir_.-.•;.;-,\,'•--,-,s\-'-,,-.-_....-..I,.7‘---A----_1.!t.L.-.\,,,:'._..-..:'..-.\-;-,.-.-,._.-.„.7--,,-_-I.,4-p..N,,,i.,..(,fi ,.,.-.-•-,..-.-,,,-,...,,4,rr1&-.,-',J/;I'It4r::/•".;r.-.a..0:.-,\I•.„A 1\A./1,..p•/'t,,,-,:-._.,---....-.-z..1.r1.!.-f.,g,..,-_,_,‘_,._,...,--,1-!-)"-.;7,,,--,,,-‘"i4l l.•%,/....\-t.‘i,-,, , ,,Th..-`'\Y,....„. D,„,,!----S",-•.• -,,.-----'\•\'\e{-,;,,,‘'--1- /-1--3-1-s,-1 I1 1- ? f . 7 -. L ,,,,r,„,,,..„ :,,, ,;:,,• . ..._ ,L , i \ `.•-•\,'..: . I 1...;.......... 71...0„/ 1 s,,4 / ...kr., • -, . s \\:. 4 Ntl t- :\ .---. \•,.• ,,,„ N, ---. ‘‘) ..-. .---• , \,•\ —1'71 - -Q,. • ,,,ir\•,•-..Vikz.-:::;‘,'Ll c---z-7.41, --.r. - ---, li z\ 'I') '1,,,•:..,:. --\, ,..,.-- --.--.'4.-.:--':-----:—.1.-7."---i/_...,,'-1-‘l'__,____,___,) / , , _,. „, , .I. • . :•) , / ,t, -.1 I / :, 1,.-I- \:'il.,.:77: ":..:2-7:"-",;11\•‘•\/:.;::: 111;ctft :.,:11\...,,1.*.p.....;‘.._.__Ii5B,r'3,t,f,d-e-1_.. 1 .1(...._\\, ::s....:,.... „\L';\;:...,',\••:::::•._,ltli;_11_,.,::: -:------:- 1 i 1 .--'--'-•-•::. Z.• kts.,,_ I r,. ,I., 0 i .....44 .,,....,,•• irif ._.-- • , -. , 1.'4 ,, P's-=-7.:-----•:"•- .4r,• L ‘. -"' , --4... -. , 1--- : 1 ,, 4* —-.,- 1 42__ , -, .3„._,t• i / I fil-,..--;., , NI,4,•.__ ,-,,,.-' 1-f-i 1 SITE /,,__„ 4.N'''':',N, ,.... MA Y•I I ( '''\ ,,,(-__.—--- -- I *_,-....-. r I . r-----\--1. k ‘ _ - - • .L. _ 1 .• '0 ".. 'I: ,:• i A i' %. \ 1 \ • ,• I'.•--.. 1 , ,.173 • . .p . - -. - . - vs. _, . 't ,I di 7 • I 1. :pne' • r 4-111 -...-- .. "k •-• . ,.5-1). .•• - - , _ ... , .., ) N '\ .I ! --' ...---'"-' '• 1 I i• --Z-• • .4 . I ,i' q • 1/ - - '''-',-, A 'V 11 ( ,, , - ' j--) i, ,1 . ( ,-,t.,---/-,„_, ,,,,, _1.1___. __ _ .. . ;. ) • ,, ,.( , .---7.' 1-. ._,-e.-1 , 1 '--___)1 ) dley ,, P-i-R. , .C. ! • i.t... 1--- /.) , ,, !.,.-7-,..i../7-7,-.- --,-, 1 .--' I. '--. • ,,'4 i-. , '.."' i,• ) '.1:11// . I'I.,"---I ...1 i ' • ' .--'liA 4 .--- ---;'.. '..1-.• -N --\., ......_-,. :..1 I • k, \I\-'''', - ' ) • ,,. t ,--- / •/ ..1.).iorne •., // .11., . • ,, --- .1 -.7::---/ 1...'i •••''' 1 6,) 12 I ' ; i i ---tir_4 ra,) - .. l •r`'\ ' \, I - . .., / /.11,--4,f IN /,/f r 1,_• /73 :-,c°'''Tre,' ' ''•••••---.__._ ____... i 41..),_.,/ i .)7T-$7:.1 1 '• '/4 ii,-,.---1 ' • (- • - _rs' ,`.----,._. \.,.. 1 ) 1 n, '•'' s'. 's t I.\'ii •4•:,-''.....•.,- ...--1--;' I .4..., j.e., 1 ...1;.L ,., ,, •\ /• II. - T --...--4-- ---- — -I. • , \ - ' N ."'/..,,- 21141-1rir,::----, '-:•---'.,...1'..,_, ,f 4* , .. • 7,.. . - /-7.---.- - _), :--.,-'.—=.1',c„,/ .• . ,! _.,•f7,- - , 1,.13• .. • -, 1 ,., , • ,- ---, r, .I., ,• ji,..-: . _...„11!/p. •/.1.4,7,f./ _ ' -,1 . elk% I 1 •.'-. \'•/- .L.- wr,... IF 1 ._.t, f-,1703.7t--_-_--:-__-•-.7,--;„„_:-3-(,:-.,-.. .,; .._, -1-14,4,r 1 . 't • 7--: • 7:---:•--..• 188_ •-”- '. ,iii- '-\' r • . ") /-,--- , , . ',.___,2-•_- ..:.•=-.7-1-.1,, ,S ..,;- C I,' -'-,., .---1196 1 ‘‘!'---4 -..-7-4.-1--*L..,• -7 "--• ',.. '',; / ..-- \•-,\,.... --,3 il..'''''-' elif-1_,-: I'---=-_ '''-'"_-_:-ir 1//o'.;-\., kr-k,•' .. -"a•---tc ,v; ''. ' ' ':, •Cerit .1.``.. ---'..,,, \ \ 1 1 ''-..4--.---::L-.) /:/y, -, j""_____ __,-Nr„,/,.. f=sic:.----1--Ilsi '."-:„..>..F,...,_ 1 \,..,,_,..)r_ct ,,,,,.. '..._,' --_-,"1144' ' .' • ,`" --,k N.k,v,::,,ii„is-'- --,'0"r• '.'r• , . , •-"llit 17 -',,,,/ ; J /--../-\ r" e'',.,.• •,__.\i‘.,‘ '`... •:". ...t.,)' ;•,, 1 .. \v„iv..., i 69 •-t - 1-. ( '''••z....,-.•..1. f _,--.,- -'t..,' 1/ '\,• -7',.= .I • "Cr - So;thnic • 1,) ) i ----N._ =.._-..-, ,, , ...„ \ ---• / . ,..6:::...D.,.. _,e. ...,..,,, j?..--.-T•2-4 • 'k ‘'.., ---. l'.'.. iv•, . ,,..„-'1„,- •\ ,., k„.„ 1141118C11 i i I, I. 4.41:'-/e.,. - i 1 .,'/ 2 :Th ../• . 1 ' i "J.. '1.(„•-•)Y I I . y.' I, ,» f „- 'Ik.--_:<"-, -'.1_; I ' / . I --,/ .--. ,,,- I 4' t'''' ‘`------....-•7,-- -, , •7‘..;••:,44,er.•::::•'.7.• ..• 1 'j.•!''21'-..' I . \---.s`'-'..-•/) '",' ( •••4., t,--,- ( ir..\ (.. (.4h1W‘li, 4 •'o4.7).'.....'" 1. • i•:-t.,•_••,-/•.'.1,-1. c---, •, ( , —--,,,--..7.:7.1::,'t::. r d- ';'% L''' •-•',/ I. -*-- j C j‘, --‘-47 !C,-,-.....--:-..., i.7_,..."',./1,- -.--f- 'i II 0 i 1-1 ( \\s,. ' ' ///- .,"•-_-7,_::__-,..--2. ;,, .....\-:,.::::,_._.,‘ ....._ ! -a- ..r.- .--*--`-t-— _-/,..:. - ...1.---_- _'.4111...r) __-__. !,._,..,,..„_,. __.___ • ... . __-z___,_. ,...., . . ' l" •- .-•". :1 - t-. -',-;'1..-, e_.• , .:ri,;-;" •l'ri (-- ,.•-•: - 1 .1 ...• N ... /, • •• 4.-,.: ' ,•.:,_._.,, ; - • , `-,.:-_.( ''' ) ). ••• „,,. „ •••,, , -,,, tial ft-•-• .- ,• --... .. , '. vv3s),,- / .-,,--, ,_ • , :, •• .,----„,. ••,k -,-., —...., •• . - ./ • , ,• — • .„.„., .. ., •---.:.,..--.--. .. . ./...--..,- . .. . . -\. ••._..,..,.........„ -ir;:"..,.. . :.7'-: ---;';':,/ ..__.. , • ,•, -, J . Z1, ) _ II . '''.,. -;_.-.4-''.k_...•1•••:— -.- --."'' :,,../..- tilY' .' • "-- c,--1 ..•• • - . ._ ..._ .'• • • Slife.0;'''. ._?_:---" --te..'•-',77." -; '..-1 fi . :-.. y----- ,../:•"li, ..4.- - s . , 1 (--_ \t'.. .- . Lit. • . • ' , I . . ,,.•••--...- ---. . '' 2- :Cn - • „'' J ---.......,,,,, .. _ .. , ., • i ji (.4;...,,`:(1:\--1.. __/_;,,le,,/.---....'".•(-\%\"- ' ' ' ''(- \-.7 ;'''''—. '. ' -• '•.*:,-'-'1[,:'' '0 •, ir,ire •.: '.1' • . 11 ' i•I'•- . usj'N•••!. '. ' ' :---f. -•- .. -.-;."',.. .. :.:.,(‘- ..-t•-•-•--7--:-..;-:--•-:.!7--.,1"_-•-•:'• .-...-1 i : • ;, ; L/-\---:.. • 1. TOPOGRAPHIC MAP IMAGE COURTESY OF THE US.GEOLOGICAL SURVEY QUADRANGLES INCLUDE:SOUTHWEST GOLDSBORO,NC(1/1/1998)and MOUNT OLIVE,NC(1/1/1977). Project Manager: Project Name. COURY TOPOGRAPHIC MAP Appendix STC= Dudley NPDES , . Drawn by: r=2,000'Scale: Dudley Plywood Facility STC 10414C4 4 itiGth14441,40 l'ttC Checked by:CC File Name: PO B 125 NPDES Permit Application 2 ox 139 Brewington Road Approved by: Date: Hampstead,NC 28443 Dudley,Wayne County,North Carolina CC Sept 2021 1 APPENDIX 3 WASTEWATER FLOW LINE DIAGRAM WATER WITHDRAWAL WET DECK From Pond or ► 6 HEADS _ BARK —� SETTLING 001 Groundwater 113 GPM/HEAD SCREEN / POND SAMPLE Well / \ 1 , Storm Water POND AND WATER FLOW _. N/A _.teem owns wo I 4 • APPENDIX 4 STORMWATER SUPPORTING CALCULATIONS Volume Calculations Method: NRCS Methodology Weighted Average Volume Technique 1. CN Impervious=98, CN Pervious 35 2. A=(Runoff)Area =63 Acres(88%impervious) 3. I =Intensity, Rainfall(NOAA Atlas 14,Volume 2,Version 3 for the Dudley, NC station) 25-yr, 24hr.storm: 7.2 inches Annual Average Precipitation: 48 inches/year 4. Impervious Area S=1000/CN-10 S= 0.2 inches Impervious Area Abstraction=0.2(S)=0.04 inches;0.8(S)=0.16 inches Pervious Area Runoff Volume=Q=(P-0.2S)2/( P+0.8S) Qlmperv25yr=(7.2-0.04)2/(7.2+0.16)=6.97 inches QlmpervAnn =(48-0.04)2/(48+0.16)=47.76 inches 5. Pervious Area-S=18.6 inches Impervious Area Abstraction=0.2(S)=3.71 inches;0.8(S)= 14.9 inches Qlmperv25yr=(7.2-3.71)2/(7.2+14.9)=0.55 inches QlmpervAnn=(48-3.71)2/(48+14.9)=31.2 inches 6. Runoff Volume 55 Acres Impervious,8 acres pervious Runoff Volume=(rain ft x acre x 43560 sf per acre) Runoff Volume 25 yr=(6.97/12 x 55 x 43560)+(0.55/12 x 8 x 43560)= 1,407,533 cubic feet=10.5 million gal Runoff Volume Annual=(47.76/12 x 55 x 43560)+(31.2/12 x 8 x 43560) _ 10,441,332 cubic feet=78 million gal • + Pond Calculations 1. Pond dimensions and compare to minimum design requirements a. Minimum Length to Width ratio is 2:1 b. The depth is 4'for the permanent pool c. The dimensions of the pond are 350' by 170'and 130'by 100' Surface area=72,500 ft2 Volume=290,000 ft3 2. Determine Hydraulic Residence Time(HRT) a. HRT=Volume/Qavg Qavg=678 gpm*60 minutes/hour* 24 hours/day*0.134 ft3/gallon=130,826 ft3/day HRT=290,000 ft3/130,826 ft3/day*24 hours/day=53 hours