HomeMy WebLinkAboutSW1221003_Supplement-EZ Form_20221031SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1
Project Name
Mills River Townhomes single-family Attached Development
2
Project Area (ac)
37,001
3
F5
Coastal Wetland Area (ac
0.000
4
Surface Water Area ac
0.194
Is this project High or Low Density?
Nigh
6
Does this project use an off -site SCM?
No
COMPLIANCE WITH 02H A 003(4)
7
Width of vegetated setbacks provided (feet)
0
8
Will the vegetated setback remain vegetated?
NIA
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d ?
NIA
10
Is streambank stabilization proposed on this project?
No
UMBER AND TYPE OF SC Ms:
11
Infiltration System
12
Bioretention Cell
13
Wet Pond
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
17
Rainwater Harvesting RWH
18
Green Roof
19
LevelSpreader-Filter StriLS-FS
20
Disconnected Impervious Surface DIS
21
Trealment Swale
22
Dry Pond
23
Stormfilter
24
Silva Cell
25
Ba filter
3
26
IFilterra
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
Mark Brooks, PE
28
Organization:
Brooks En i neering Associates PA
29
Street address:
15 Artlington Street
30
City, State, Zip:
Asheville NC 28801
31
Phone numbers ;
828-232-4700
32
Email:
mbrooks@brooksea.com
Certification Statement:
I certify, under penally of law that this Supplement-EZ form and all supporting information were prepared under my directlon or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting informatics are consistent with the information provided here.
Signature of Designer
Date
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
3
3
Does this project have low density areas?
No
4
If so, number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
2
3
4
Type of SCM
Ba Filter
Ba Filter
Ba Filter
Ba Filter
5
Total drainage area (sq ft
529861 cf
229334
158200
142327
6
Onsite drainage area (sq ft)
529861 cf
229334
158200
142327
7
Offsite drainage area (sq ft
cf
0
0
0
8
Total BUA in project (sq ft
374003 cf
147233 sf
126899 sf
99871 sf
9
New BUA on subdivided lots (subject to permitting)
(sq ft
208076 cf
66204 sf
83145 sf
58727 sf
10
New BUA not on subdivided lots (subject to
permitting) (so
138523 cf
53625 sf
43754 sf
41144 sf
11
Offsite BUA (sq ft
cf
sf
sf
sf
12
Breakdown of new BUA not on subdivided lots:
cf
0
0
0
Parking (sq ft
cf
sf
sf
sf
Sidewalk (sq ft
cf
sf
sf
sf
Roof (sq ft
cf
sf
sf
sf
Roadway (sq ft)
122546 cf
53625 sf
43751 sf
25170 sf
Future (sq ft
cf
sf
sf
Other, please specify in the comment box
below (sq ft)
15974 cf
sf
sf
15974 sf
13
New infiltrating permeable pavement on
subdivided lots (sq ft
cf
sf
sf
sf
14
New infiltrating permeable pavement not on
Isubdivided lots (sq ft
cf
sf
sf
sf
15permitting)
Existing BUA that will remain (not subject to
s ft
cf
sf
sf
sf
16
Existing BUA that is already permitted (sq ft)
cf
sf
sf
sf
17
Existing BUA that will be removed (sq ft
3126 cf
3126 sf
sf
sf
18
Percent BUA
-
64%
80%
70%
19
Design storm inches
-
1.8 in
1.5 in
2.2 in
20
Design volume of SCM cu ft
30258 cf
11998 cf
10177 cf
8083 cf
21
1 Calculation method for design volume
Simple
Simple
Simple
Simple
ADDITIONAL INFORMATION
22
Please use this space to provide any additional information about the
drainage area(s):
The amenities BUA is listed for "Other" on Item #12 for Breakdown of new
BUA not on subdivised lots. All offsite drainage areas are proposed to be
bypass the SCM's
BAYFILTER
1
1 Drainage area number
1
2
3
21
Minimum required treatment volume cu ft
11998 cf
10177 cf
8083 cf
GENERAL MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
Yes
Y-es
4
Is the SCM located away from contaminated soils?
Yes
Yes
Yes
5
What are the side slopes of the SCM (H:V)?
N/A
N/A
N/A
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
No
No
7
Are the inlets, outlets, and receiving stream protected from erosion
10- ear storm)?
Yes
Yes
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
desi n volume?
Yes
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
Pump (preferred)
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
N/A
N/A
N/A
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
Yes
Yes
Yes
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
Yes
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
Yes
Yes
16
Does the SCM follow the device specific MDC?
Yes
Yes
Yes
17
Was the SCM designed by an NC licensedprofessional?
Yes
Yes
Yes
BAYFLILTER
MDC FROM THE STORMWATER DESIGN MANUAL
18
If Volume Design is used, what is the volume from the drainage area
(cubic feet)?
12061 cf
10188 cf
8085 cf
19
Is an upstream detention used?
Yes
Yes
Yes
20
Volume of the upslope detention system (cubic feet)
3410 cf
4386 cf
3700 cf
21
Percent of the design volume contained in the upslope detention
system %
If Rate Based Sizing is used, for 1 inch or 1.5 inch (Coastal areas).
Water Qualit flow rate for draina a area cfs
Number of cartridges
Cartridge height (inches)
69%
73%
71 %
22
2.76 cfs
1.18 cfs
59 cfs
231
28
12
6
24
36 in
36 in
36 in
25
SHWT elevation (fmsl)
2075.0
2072.0
2072.0
26
Elevation of bottom of BayFilter vault (fmsl)
2077.0
2074.0
2074.0
27
Clearance from the SHWT (feet)
2 ft
2 ft
2 ft
28
BayFilter Media Flow Rate (GPM/ft2 of Media Surface)
.5 gpm/sf
.5 gpm/sf
.5 gpm/sf
29
Does the system includes a sediment sump?
No
No
No
301
If yes, the diameter of the sump (feet)
31
If yes, the depth of the sump (feet)
32
Time to drain the sump (hours)
33
Time to drain the BayFilter (hours)
30 hrs
30 hrs
30 hrs
34
Is an off-line flow splitting device used?
Yes
Yes
Yes
35
Type of media used (EMC or GAC-metals)
EMC
EMC
EMC
36
Will maintenance be performed by Certified Maintenance Providers
per instructions?
Yes
Yes
Yes
DITIONAL INFORMATI
37
Please use this space to provide any additional information about the
BayFilter system(s):