Loading...
HomeMy WebLinkAboutNCG081012_2022 DMR_20220805 (2)aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 August 03, 2022 Kate Fleming Union County Public Works 8299 Kensington Drive Waxhaw, NC 28173 RE: Project: OC-STORM Pace Project No.: 92617224 Dear Kate Fleming: Enclosed are the analytical results for sample(s) received by the laboratory on July 28, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: OC-STORM Pace Project No.: 92617224 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 CERTIFICATIONS South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water#: LA029 Virginia/VELAP Certification #: 460221 South Carolina Laboratory ID: 99030 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Pace Project No.: OC-STORM 92617224 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92617224001 OC-OUTFALL 001 EPA 1664B REL 1 PASI-C SM 254OD-2015 MAB2 1 PASI-A 92617224002 OC-OUTFALL 002 EPA 1664B REL 1 PASI-C SM 254OD-2015 MAB2 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: OC-STORM Pace Project No.: 92617224 Sample: OC-OUTFALL 001 Lab ID: 92617224001 Collected: 07/26/22 12:54 Received: 07/28/22 07:15 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 4.9 1 08/03/22 01:00 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 67.6 mg/L 10.0 1 07/31/22 14:52 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/03/2022 04:45 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: OC-STORM Pace Project No.: 92617224 Sample: OC-OUTFALL 002 Lab ID: 92617224002 Collected: 07/26/22 13:02 Received: 07/28/22 07:15 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 4.8 1 08/03/22 01:00 2540D Total Suspended Solids Analytical Method: SM 2540D-2015 Pace Analytical Services - Asheville Total Suspended Solids 4.7 mg/L 2.6 1 07/31/22 14:52 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/03/2022 04:45 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: OC-STORM Pace Project No.: 92617224 QC Batch: 714508 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92617224001, 92617224002 METHOD BLANK: 3725256 Matrix: Water Associated Lab Samples: 92617224001, 92617224002 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Petroleum Hydrocarbons mg/L ND 5.0 08/03/22 01:00 LABORATORY CONTROL SAMPLE: 3725257 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L 20 13.5 68 64-132 MATRIX SPIKE SAMPLE: 3725258 92617216002 Spike MS MS % Rec Parameter Units Result Cone. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L ND 19.6 20.9 84 64-132 SAMPLE DUPLICATE: 3725259 92616934002 Dup Parameter Units Result Result RPD Qualifiers Total Petroleum Hydrocarbons mg/L ND ND Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/03/2022 04:45 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: OC-STORM Pace Project No.: 92617224 QC Batch: 714009 Analysis Method: SM 2540D-2015 QC Batch Method: SM 254OD-2015 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92617224001, 92617224002 METHOD BLANK: 3722567 Matrix: Water Associated Lab Samples: 92617224001, 92617224002 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 07/31/22 14:49 LABORATORY CONTROL SAMPLE: 3722568 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 252 242 96 90-110 SAMPLE DUPLICATE: 3722648 92617224001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 67.6 69.2 2 SAMPLE DUPLICATE: 3722649 92617253006 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 12.7 11.8 7 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/03/2022 04:45 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: OC-STORM Pace Project No.: 92617224 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/03/2022 04:45 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: OC-STORM Pace Project No.: 92617224 Lab ID Sample ID QC Batch Method QC Batch 92617224001 OC-OUTFALL 001 EPA 1664B 714508 92617224002 OC-OUTFALL 002 EPA 1664B 714508 92617224001 OC-OUTFALL 001 SM 254OD-2015 714009 92617224002 OC-OUTFALL 002 SM 254OD-2015 714009 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/03/2022 04:45 PM without the written consent of Pace Analytical Services, LLC. Analytical Analytical Method Batch Page 9 of 12 -ace I uc.tF t'tie; elvv-rr[Ivl-tllJfVi-UUt3:5 vUll -sample Condition Upon Receipt - Effective Date: 051121202205/12/2022 Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersville E- Raleigh❑ Mechanicsville[] Atlanta❑ Kernersville❑ ConditionSample Client Name: Upon Receipt � � Project #: WO # : 921'6172,24 ❑ Commercial Pace ed Ex ❑UPS ❑USPS ❑0ther. ❑Client 1111111111111111111111 82617224- Custody Seal present? Yes LANo Seals Intact? Dyes PWO Date/Initials Person Examining Contents: Packing Material: ❑Bubble Wrap lysubble bags ❑None ❑ Other Biological Tissue Frozen? Thermom t r: Des ❑No�ON/A A R Gen ID: IT() Type of Ice: J2(G Cl ❑olue ❑None /; r� Correction Factor: ' �' Cooler Temp: _ V , L Add/Subtract ("C) V Temp should be above freezing to 6°C []Samples out of temp criteria. Samples on ice, cooling process Cooler Temp Corrected (°C): 61 IZ has hegun USDA Regulated Soil (YN/A, water sample) Did samples originate in a quarantine zone within the United States: CA, NY, or SC Did samoles nripinmr frnm n fnrrinn .nnrro (i,ror ­;,..._11,. Chain of Custody Present? Samples Arrived within Hold Time? Short Hold Time Analysis (<72 hr.)? Rush Turn Around Time Requested? Sufficient Volume? Correct Containers Used? -Pace Containers Used? Containers Intact? Dissolved analysis: Sampfes Field Filtered? Sample Labels Match COC? -Includes Date/Time/ID/Analysis Matrix Headspace in VOA Vials (a5-6mm)? Trip Blank Present? Trip Blank Custody Seals Present? COMMENTS/SAMPLE DISCREPANCY CLIENT NOTIFICATION/RESOLUTION ,VJYes L_JNn ❑N/A 1 2. ❑Yes Uno ❑N/A 3. ❑Yes ffNo ❑N/A 4. 12fes [:IN. ❑N/A S. "Yes ❑No ❑N/A 6. Yes [:]No ❑N/A les ❑Na ❑N/A 7. ❑Yes ❑NO --ZN/A S, •M Yes [:]No ❑N/A i 1 Oyes I5wo Des V1. including Hawaii and Puerto Rico)? ❑Yes ❑No Comments/blscrepancv: Lot ID of split containers: Person contacted: Date/Time; Project Manager SCURF Review: Profr?0 IVlanaaar CRP Reyie? ,!- Date: Field Data Required? ❑Yes []No Qualtrax ID: 69614 Page 1 of 2 Page 10 of 12 I'tJp L iav r%iwi nuv4 I-vvo3 vU I_aample uonaltlon upon Kecelpt ce- Effective Date: 05112/202205/12/2022 *Check mark top half of box if pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, Wig **Bottom half of box is to list number of bottles ***Check all unpreserved Nitrates for chlorine Project # W4 : 926172,24 PM: MI4B Due Date: 08/11/22 CLIEN'r: 92-Union Cou z _0z v a n N H 7 z Ili 9J a J voi N z m a a J o N5 ¢ is v `-' d = ri u ry v 0. O y a J E N v a O 2 N a J o n N o a N a -J n S Z a J L m v ° E } } ? i' Ll `m E Q °' N y a 2 w E Q rl v m a = a Q J 0 N S CL m E 4 ,y ry a O S n ¢ .�.1 E o N u z Z I ¢ J E o N ¢ ' ? U = 4 E 4 M Q is z 0 1J E E � Q z _0 N 0 > E O q Z rrl x 0 > E po V Z O N a a 4 �! E C Z H ] u x a i1. M Q N IL w ¢; VY E N .i = .� [p O.. m v VS E Ul N w °. 7 n E E G a R N 2 Z `- M a. E Ln N Z C a E q E O 71 Z C ° tl a Ix E o N _ m m IL m 6 m a Co rn a. to a a q,. m $ l7 a a lJ L7 a 00O. a O1 (9 a 0+ O os l7 a m U' 7 rn U' n m 0N a > CL 0- M m CLD 1 Z x 3 4 \ 5 6 7 8 9 1O N_ NN11 1Z - PH Adjustment Log for Preserved Samples Sample ID Type of Preservativ�upon Date preservation adjusted Time preservation Amount of Preservative Lot q adjusted added uiei c u d urscrepdnLy anecting worth Larolina Compliance samples, a copy of this form will be sent to the North Carolina DENR Certification Office (i.e. Out of hold, incorrect preservative, out of temp, incorrect containers. Qualtrax ID: 69614 Page 2 of 2 Page 11 of 12 Cn v r M m Z a A � z c m M 3 m m n y p 0 z Vl VI ❑ D z r r D m m C A A I � m 3 m 9 0 z a N m r.f TEMP in C Received on ce (Y/N) ustp y Seated l DQjel YIN) Samples Intact (YIN) CJ -0 m* Q 0 A A M 1 a m 0-4 m 0 A w n� ITEM # m m m. x�-3 o a b g N Q n n 0 0 0 0 c� n n n ❑ c Z m o b b o W z nc� C^ N ry CO N D 3 0 N ice] V#I 7 D NJ (DLn W 0 D n v ➢ N [V G Q �' N N C 3 W 7 r. T Q, M L x D m d 0 m -fie tipnFoma�hayr - --_- _y a��-max T v 0 ;U e -x rn ' o o c C o m m m 0 a v = c �' m Z z c m m o p a m 3 :3 O o m d it N y � CD� o MATRIX CODE (see vaFd Codes W left) SAMPLETYPE (G=GRAB C-CO :.P) � 4 d � O _� O m D � CT O N a � ' m z 6 _ n N N N N SAMPLE TEMP AT COLLECTIO Residual Chlorine N r�- n � CD n ❑ n D 7 Z C O CL � 1 O C) m - a o c C o r-p 30 M s @ Z o � Q m T d oP m m r- m R o o En o ~ � ACDC=r O n �O2.m.. C O ° n ❑ E3 G1 v � c .Z..I (U � a g m _ _ m nM m Y!N 0 < O z a � C m (p :CI N ry, m 3D m N O a (1 a C m 0 0 (D m a Ca � 'z w � co rn 0 C w c � v O o W n ➢_ o m � n O Page 12 of 12