Loading...
HomeMy WebLinkAboutSW3220202_Plansheet C504 - SCM Detail_20221101TOP OF BERM 513.00jk IRV 100-YR 511.98 50-YR 511.79 SODDED FINISH GRADE, SEE GRADING PLAN 6" PVC CLEANOUT SET 6" ABOVE SURROUNDING GRADE, W/SCREWABLE WATERTIGHT CAP (SEE PLAN FOR LOCATIONS, TYP.) CLEANED WASHED "CONCRETE" SAND ASTM C-33 -�� SODDED _ _ \ 1=III=III=III=III== '.` '.` '. .` '.` '.` '. '.` '.` '.` '. .`. . . .`. .`. .`. .`. .`. . = 1=III=III=III=III=1 III _ SO - _ _ _ - _ _ _ \-III=111--111-11 1-1 -III-III-III-III-III-I .+ +.+ 1=III-III-III-III-I � `= -' 1=III-III-III . +.+ +. .. w .' Z .�+ +.�+ +.�+ +. +' +' +' + ........ . -III ... ..... .�+ +.�+ +.�+ +.�++.+++. -III-III== `III -III ........ . � � � . � � � . � % % %... I-III-III-III-11 -III -III -III -I FT -III -I \ I -_III -I III=III=III ' ' .+' ' ' ' III=1 '.` \-III- %` in ` ++� .'� .` .` ,8�8% ' .` . . . . '. ` . . . . . . ' .` '.`�+++�+++ '. _ =III- -1'I� COMPACTED SUBGRADE J 95% STD. PROCTOR -III-III . II J . t Q a ASTM D 698 II �+++z 11 ` . �%% %.`%'%%%+'. %%+'.'++++%+ ..... ...... . . ... . .=11- ` '.'+'.'++++% +`%+. +'.` '.` _ _- NON -WOVEN FILTER FABRIC =I1 ' III=' (MIRAFI 140N OR APPROVED EQUAL) OVERLAP SEAM 12" MIN. SEE NOTE 12 CLEAN, WASHED #57 STONE PROVIDE 3" MIN. ON ALL SIDES OF UNDERDRAINS GRADE SUBGRADE OF SAND FILTER AT 2% TO SUBDRAIN, (TYP.) SCARIFY SUBGRADE SOIL FOR INFILTRATION PRIOR TO PLACING FILTER MEDIA. DO NOT COMPACT TOP OF SUBGRADE AFTER SCARIFYING Sand Filter Detail for Pond # I SUITABLE STRUCTURAL SOIL COMPACTED TO 95% STANDARD PROCTOR; STRUCTURAL FILL SHALL BE APPROVED, PLACED AND COMPACTED UNDER THE DIRECT SUPERVISION OF A GEOTECHNICAL ENGINEER 1ill�,lll I-. 6' -111 SECTION Typical Pond Berm K, OUTSIDE PIPE DIA. +3' 1. 5' 1.5' SAND FILTER TYPICAL SECTION N.T.S. UNDERDRAINS @0.50%, 6" PVC PERFORATED UNDERDRAIN, SEE GRADING PLAN AND PLAN VIEW OF SAND FILTER FOR NUMBER OF UNDERDRAINS REQUIRED. WRAP UNDERDRAIN IN FILTERSOCK 0 TOP ELEV. 509.00 1 12" LAYER OF #57 STONE \ 2, 2 �- UPSTREAM00 1 o\ ��° c7� COMPACTED SUBGRADE EXISTING GRADE, REMOVE 95% STD. PROCTOR ROOT MATERIAL AND ASTM D 698 ORGANIC MATERIAL SECTION SEE PLAN FOR PIPE DIA. (TYP.) 1' MIN. CLASS B CONCRETE I' -'il III IiI-11I 111 I11 III I III TRENCH BOTTOM FRONT VIEW 11 SIDE VIEW EXTEND CONCRETE 12" MINIMUM INTO UNDISTURBED TRENCH BOTTOM. BEDDING MATERIAL SHALL NOT BE INSTALLED WHERE ANTI -SEEP COLLAR IS LOCATED. NOTES: 1. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL. 2. CONTRACTOR SHALL PROVIDE SUITABLE FORMING (TO BE REMOVED) TO CONTAIN CONCRETE FOR PROPER SHAPE AND DIMENSIONS. 3. PLACE ANTI -SEEP COLLARS AT LOCATIONS AND SPACING SHOWN ON SAND FILTER / DRY DETENTION DETAILS. 5 Anti -Seep Collar N.T.5. N.T.S. 4 Forebay Berm FINISH GRADE 2 1 DOWNSTREAM 00 0 in CLASS "B" RIP RAP NON -WOVEN FILTER FABRIC SAND FILTER NOTES 1. EXCAVATE THE SAND FILTER TO THE DESIGN DIMENSIONS, AFTER SEDIMENT BASIN IS NO LONGER REQUIRED. 2. UNDERDRAIN SYSTEMS SHALL BE SCHEDULE 40 PVC (PERFORATED AND NON -PERFORATED) PIPE MATERIAL. 3. GRAVEL COVER OVER THE UNDERDRAIN SHALL BE AT LEAST 6" IN DEPTH. 4. GRAVEL BED MATERIALS (STONE) SIZE SHALL NOT BE GREATER THAN 1/2 TO 1 1/2 INCHES IN DIAMETER (BLUE STONE, DOUBLE WASHED, #57). DEPTH OF GRAVEL SHALL NOT EXCEED 12 INCHES. 5. FILTER FABRIC MUST MEET A MINIMUM PERMEABILITY RATE OF 75 GALLONS/MINUTE/SQUARE FOOT AND SHALL NOT IMPEDE THE INFILTRATION RATE OF THE SOIL MEDIUM. NON -WOVEN FABRIC IS PREFERRED OVER WOVEN AND INSTALLATION REQUIRES AT LEAST 1 FOOT OVERLAP AT THE ENDS AND STAKING IN PLACE DURING CONSTRUCTION AT THE TURNED SURFACES. 6. DRAINAGE AREA TO SAND FILTER TO BE STABILIZED BEFORE FILTRATION CONTROLS AND FILTER MEDIA ARE INSTALLED. 7. SET UP AN ON -SITE PRE -CONSTRUCTION CONFERENCE WITH THE DESIGN TEAM AT LEAST 48 HOURS PRIOR TO STARTING CONSTRUCTION ON ANY SCMS. 8. SOIL COMPACTION TESTS ARE REQUIRED ON ANY BERMS >/= 5FT IN HEIGHT FROM THE NATURAL GRADE. SOIL COMPACTION MUST BE AT LEAST 95% PROCTOR AND CERTIFIED BY A LICENSED SOIL ENGINEER. 9. SAND FILTER IS A MINIMUM OF 100' FROM ANY WATER SUPPLY WELL. 10. THE SEASONAL HIGH WATER TABLE IS A MINIMUM OF 2' BELOW THE SAND FILTER. 11. BOTTOM OF BMP AND SLOPES DRAINING TOWARD THE SAND FILTER SHALL BE SODDED. 12. INSTALL TOP LAYER OF NON -WOVEN FILTER FABRIC IMMEDIATELY UPON BRINGING TOP OF SAND TO GRADE. LEAVE THE FABRIC INTACT UNTIL THE 1 YEAR WARRANTY PERIOD. REMOVE FABRIC AND ANY ACCUMULATED SEDIMENT AT THE 1 YEAR WARRANTY DATE. • - - - - M■■■M ■■■■, • CLEANOUT TO BE SET 6" ABOVE GRADE CLEANED WASHED "CONCRETE" SAND ASTM C-33 CLEANOUT CLEANED WASHED #57 STONE 511.25 509.00 12' \ THIS SIDE FACES 1 SIDE ONLY SAND FILTER 2"x2" STEEL ANGLE WEIR SECTION FRAME WELDED TO N.T.S. SUPPORT 6.-0. SOUARE zJ IN 12o 0 0 0 0 0 0 0 0 ONO,,_ O O O O O O O O O IIFROM SAND FILTER SEE SCHEDULE FOR INVERTS 6" PERFORATED PVC PIPE @ 0.50% SLOPE Outlet Control Structure 6" SOLID PVC SAND I L FILTER TO STRUCTURE 510 6" PVC / OUTLET CONTR0.50% MIN. \ OL 2 �� 513- �o STRUCTURE 50 0 p� ANTI -SEEP COLLARS 5 513 SCM ACCESS \ / 50 / 511- rT�, I EASEMENT (TYP.) \� 5C o\\ \ OCS 29 /1 \\ ' OCO2 / RIP RAP APRON 5 '--I //�/ FES28 c a I I / \ _ ♦ Ok y 50 \ Q GRO P �- EVl / 1\ I I I I CO 8 ( / I o toto I I LID i �` // / SOD SLOP � I \\ L. SOD TOP OF J FOREBAY BERM BERM, INSIDE I � 4 \ ` ( 50 ) I SLOPE AND I o ` �� \ BOTTOM 508 I Il ~\ _ \ \ I , \\ \ \ 1 \ I\ I GRADE BOTTOM MI SAND FILTER TO \ \ , IS, cm CONSTRUCT \ o \\ \ \ \ \ \ \ BERM 6" \ \ \ HIGHER THAN \ \ \� \\ DESIGN TO \ l ACCOUNT FOR \ \ \ SETTLEMENT iewVI \ AS-:UILT SUPV/FYI AFTER COMPLETION OF CONSTRUCTION OF THE PROJECT, AN ASSUILT SURVEY OF THE STORM DRAINAGE SYSTEM (INCLUDING THE BMP PONDS WITH OUTLET STRUCTURE INFORMATION) SHALL BE COMPLETED AND SUBMITTED TO THE DESIGNER FOR REVIEW. CONTRACTOR SHALL INCLUDE THIS COST IN THEIR BID. DESIGN MODIFICATIONS TO PONDS AS A RESULT OF IMPROPER CONSTRUCTION AND CITY REVIEW WILL BE AT THE EXPENSE OF THE CONTRACTOR. BASIN CONVERSION: BASIN SHALL BE USED AS EROSION CONTROL BASIN DURING CONSTRUCTION. DO NOT CONVERT EROSION CONTROL BASIN UNTIL ALL OF THE CONTRIBUTING BASIN IS STABILIZED. PRIOR TO CONVERSION, EXCAVATE ACCUMULATED SEDIMENT AND SPREAD ON -SITE. ENSURE POND IS EXCAVATED TO DESIGN ELEVATIONS AS SHOWN ON PLAN PRIOR TO PLANTING AND FINISHING THE BASINS. \ RIP RAP AF 510 5 C50 10� ONE YEAR CONTINUED MAINTENANCE AGREEMENT THE INFORMATION BELOW SHALL BE INCLUDED IN THE CONTRACT BY THE CONTRACTOR AS REQUIRED IN THE CONTINUED ONE YEAR MAINTENANCE AGREEMENT WITH THE OWNER. MAINTENANCE INSPECTION REPORTS AS INDICATED IN THE POST -CONSTRUCTION STORM WATER ORDINANCE, ANNUAL MAINTENANCE INSPECTION REPORTS SHALL BE SUBMITTED TO THE STORM WATER ADMINISTRATOR. THE FIRST REPORT SHALL BE SUBMITTED ONE YEAR FOLLOWING THE FINAL APPROVAL DATE OF THE BMP PER THIS CONTRACT. SUBSEQUENT REPORTS WILL THEN BE THE RESPONSIBILITY OF THE OWNER EACH YEAR THEREAFTER ON OR BEFORE THE APPROVAL ANNIVERSARY DATE. ALL MAINTENANCE ACTIVITIES AND INSPECTION REPORTS SHALL BE DOCUMENTED USING THE FORMS CONTAINED IN THE ADMINISTRATIVE MANUAL. ANNUAL MAINTENANCE INSPECTION REPORTS SHALL BE SEALED BY A REGISTERED NORTH CAROLINA PROFESSIONAL ENGINEER OR LANDSCAPE ARCHITECT. THESE INSPECTIONS SHALL BE DISCONTINUED ONLY IF THE BMPS ARE ACCEPTED FOR MAINTENANCE BY THE APPLICABLE JURISDICTION. NOTE: THE MAINTENANCE AGREEMENT SHALL BEGIN UPON FULL ACCEPTANCE OF THE BMP, NOT NECESSARILY AT SUBSTANTIAL COMPLETION OF THE PROJECT. THE FIRST REPORT BY THE CONTRACTOR SHALL BE PROVIDED AT THE 11 MONTH IN THE 12 MONTH AGREEMENT. ROUTINE MAINTENANCE TASKS AND SCHEDULE (PER POND DETAILS AND NOTES INCLUDED IN THIS SET OF PLANS AND PER SAND FILTER BASIN REQUIREMENTS IN THE STORM WATER BMP MANUAL) NOTE: WHERE MAINTENANCE IS INDICATED IN THE TABLE AS "YEARLY", THE TASK SHALL BE PERFORMED AT THE 11 MONTH MARK IN THE 12 MONTH CONTRACT. 10-YR 511.10 2-YR 509.94 1-YR 509.48 NOTE: BLOCK WEIR TO ELEVATION 510.00 UNTIL FINAL SCM CONVERSION 10, TOP OF BERM ELEV.-513.00 3 �1 COMPACTED SUBGRADE 95% STD. PROCTOR ASTM D 698 TRASH RACK (SEE DETAIL THIS SHEET) 6.0'x6.0' MASONRY STRUCTURE, 6" THICK SOLID MASONRY WALL(FILL CELLS). OPTIONAL PRE -CAST STRUCTURE IS ALLOWED WITH SUBMITTAL OF SEALED SHOP DRAWINGS 36" 0-RING RCP W/ ANTI -SEEP COLLARS INV. OUT=502.00 8" THICK CONC. SLAB - 6" PERFORATED PVC @ 0.50% MIN. (TYP.) PDE PDE P � � I /l l I CO 3 14 36d - 34d I 3 1 6" CLEANOUT AT ALL I I CO 5 I RE( JUNCTIONS AND ENDS (TYP.) I STC. CD w I CO I I LIMITS OF SAND FILTER (DO NOT PLACE I CO 9 I SOD ON TOP OF 70 SANDFILTER ZONE) I 01 L0 I I �► I I II LID II II I \ imi I I \ I 3 POND BERM KEY \ 11 I 50 (DASHED LINE)FUTI \ RECURE PARKS & UNCONDITIONED I \ STORAGE 5000 S F. \ ICI / 1 II t � ® MH2 - BMP MAINTENANCE THE BMP LANDSCAPE CONTRACTOR SHALL MAINTAIN THE VEGETATION WITHIN THE SAND FILTER BASIN UNTIL THE PROJECT IS ACCEPTED BY THE OWNER AND THEN FOR A PERIOD OF ONE YEAR FROM THAT DATE. CONTRACTOR SHALL ENSURE PLANTINGS ARE ADEQUATELY WATERED AND PROVIDE MEANS OF WATERING WHEN NECESSARY TO PROMOTE GROWTH. CONTRACTOR SHALL ALSO MAINTAIN INLET AND OUTLETS OF THE BASIN TO MAKE SURE THEY ARE WORKING PROPERLY AND WATER LEVELS ARE MAINTAINED. CONTRACTOR SHALL ALSO RE -PLANT ANY AREAS THAT DID NOT ESTABLISH ADEQUATELY. VEGETATION INCLUDES SOD AREAS, WETLAND PLANTS, AND WETLAND SEEDED AREAS. SAND FILTER NOTES; 1. EXCAVATE THE SAND FILTER TO THE DESIGN DIMENSIONS, AFTER SEDIMENT BASIN IS NO LONGER REQUIRED. 6. AN OBSERVATION/CLEANOUT STANDPIPE MUST BE INSTALLED IN EVERY SAND FILTER FACILITY THAT HAS A DEPTH GREATER THAN 2 FEET AND/OR AN SAND FILTER MAINTENANCE CONT. 2. UNDERDRAIN SYSTEMS SHALL BE SCHEDULE 40 PVC (PERFORATED AND UNDERDRAIN SYSTEM. THE STAND PIPE MUST CONSIST OF A RIGID NON -PERFORATED) PIPE MATERIAL. NON -PERFORATED PVC PIPE, 4 TO 6 INCHES IN DIAMETER. IT SHOULD BE 1. MANAGE THE DRAINAGE AREA TO REDUCE THE SEDIMENT LOAD TO THE SAND FILTER. CAPPED FLUSH WITH THE GROUND ELEVATION OF THE FACILITY. THE TOP OF 2. CLEAN OUT THE SEDIMENTATION CHAMBER OR FOREBAY WHENEVER SEDIMENT DEPTH EXCEEDS SIX 3. GRAVEL COVER OVER THE UNDERDRAIN SHALL BE AT LEAST 6" IN DEPTH. THE WELL SHALL BE CAPPED WITH A WATERTIGHT CAP. INCHES. 4. GRAVEL BED MATERIALS (STONE) SIZE SHALL NOT BE GREATER THAN 1/2 TO 7. DRAINAGE AREA TO SAND FILTER TO BE STABILIZED BEFORE FILTRATION 3. AT LEAST ONCE A YEAR, SKIM THE SAND MEDIA. 1-1/2 INCHES IN DIAMETER (BLUE STONE, DOUBLE WASHED, #57). DEPTH OF CONTROLS AND FILTER MEDIA ARE INSTALLED. 4. REPLACE THE SAND FILTER MEDIA WHENEVER IT FAILS TO FUNCTION PROPERLY AFTER MAINTENANCE. GRAVEL SHALL NOT EXCEED 12 INCHES. 5. INSPECT THE SAND FILTER AT LEAST QUARTERLY. ANY PROBLEMS THAT ARE FOUND SHALL BE REPAIRED 8. SET UP AN ON -SITE PRE -CONSTRUCTION CONFERENCE WITH THE DESIGN TEAM IMMEDIATELY. 5. FILTER FABRIC MUST MEET A MINIMUM PERMEABILITY RATE OF 75 AT LEAST 48 HOURS PRIOR TO STARTING CONSTRUCTION ON ANY BMPS WITH GALLONS/MINUTE/SQUARE FOOT AND SHALL NOT IMPEDE THE INFILTRATION LUESA WQ INSPECTOR COREY PRIDDY AT 980-721-9058 RATE OF THE SOIL MEDIUM. NON -WOVEN FABRIC IS PREFERRED OVER WOVEN MAINTAIN OPERATION AND MAINTENANCE RECORDS IN A KNOWN SET LOCATION. OPERATION AND AND INSTALLATION REQUIRES AT LEAST 1 FOOT OVERLAP AT THE ENDS AND 9. SOIL COMPACTION TESTS ARE REQUIRED ON ANY BERMS >/= 5FT IN HEIGHT MAINTENANCE RECORDS WILL BE AVAILABLE UPON REQUEST. STAKING IN PLACE DURING CONSTRUCTION AT THE TURNED SURFACES. FROM THE NATURAL GRADE. SOIL COMPACTION MUST BE AT LEAST 95% PROCTOR AND CERTIFIED BY A LICENSED SOIL ENGINEER. REFER TO OPERATIONS AND MAINTENANCE AGREEMENT FOR MORE INFORMATION. SSMH 6 , i �51 DI 3 `\ I\ o.. D 0 p 0 0 0 .D A .D o D D . adWnrrki+,mrtS environments life architecture planning interiors six coliseum centre 2815 coliseum centre drive suite 500 charlotte, north carolina 28217 t] 704 379 1919 f] 704 379 1920 www.adwarchitects.com benesch Alfred Benesch & Company 2359 Perimeter Pointe Parkway, Suite 350 Charlotte, NC 28208 www.benesch.com 704.521.9880 Corp. NC License: F-1320 Project #17.000405 WAXHAW TOWN CAMPUS 4220 WAXHAW MARVI N RD. WAXHAW, NC 28173 CONSTRUCTION DOCUMENTS SCM DETAILS DATE 5.17.2022 PROJECT NO 20051 REVISIONS NO DATE DESCRIPTION: Q 06.13.22 ADDENDUM NO. 02 THIS DRAWING IS THE PROPERTY OF ADW ARCHITECTS, PA. AND SHALL NOT BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT SHALL NOT BE USED ON ANY OTHER PROJECT OR GIVEN TO ANY OTHER COMPANY OR AGENCY WITHOUT THE CONSENT OF ADW ARCHITECTS, PA. OF SI '•.. SEAL W S 15471 /t SEAL •••'�j�Y l� i `SN �`��,` SHEET NUMBER