Loading...
HomeMy WebLinkAboutSW6221101_Supplement-EZ Form_20221129SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 jProject Name 2 1Proiect Area (ac) Surface Water Area (ac) Is this project High or Low Density? Does this Proiect use an off -site SCM? Fort BraggTechnical Support Annex, PN79439.2 17.17 0 0 High No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet N/A 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 3 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 1 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Lorraine Roberts, PE - Civil Engineer 28 Organization: Exp Federal Inc. 29 Street address: 205 N. Michigan Ave., Suite 3800 30 City, State, Zip: Chicago, IL 60601 31 Phone numbers : 312-616-3309 32 Email: Lorraine.Roberts@expfederal.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. SS�o SEAL EN `INFER 4�iyE B. Ro�� Signature of Designer 11 /16/2022 Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 4 3 Does this project have low density areas? No 4 If so, number of low density drainage areas 0 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 3 4 4 Type of SCM - Dry Pond Bioretention Bioretention Bioretention 5 Total drainage area (sq ft 747925.2 409464 43560 34848 47916 6 Onsite drainage area (sq ft 621165.6 409464 43560 34848 47916 7 Offsite drainage area (sq ft 126759.6 0 0 0 0 8 Total BUA in project (sq ft 357628 sf 226512 sf 32670 sf 28314 sf 37026 sf 9 New BUA on subdivided lots (subject to ermitting) (sq ft N/A N/A N/A N/A N/A 10permitting) New BUA not on subdivided lots (subject to s 298386 sf 226512 sf 32670 sf 28314 sf 37026 sf 11 Offsite BUA (sq ft 59242 sf N/A N/A N/A N/A 12 Breakdown of new BUA not on subdivided lots: Parkina (sq ft Sidewalk (sq ft - - - - - 54014 sf 23958 sf 10019 sf 10019 sf 10019 sf - - - - - Roof (sq ft 40511 sf 40511 sf Roadway s ft 26136 sf 26136 sf Future (sq ft - - Other, please specify in the comment box below (sq ft 118483 sf 13 New infiltrating permeable pavement on subdivided lots (sq ft N/A N/A N/A N/A N/A 14 New infiltrating permeable pavement not on subdivided lots (sq ft N/A N/A N/A N/A N/A 15permitting) Existing BUA that will remain (not subject to s ft N/A N/A N/A N/A N/A 16 Existing BUA that is already permitted (sq ft N/A N/A N/A N/A N/A 17 Existing BUA that will be removed (sq ft N/A N/A N/A N/A N/A 18 Percent BUA 48% 55% 75% 81 % 77% 19 Design storm inches 1.0 in 1.0 in 1.0 in 1.0 in 1.0 in 20 Design volume of SCM cu ft 29938 cf 16625 cf 2632 cf 2269 cf 2977 cf 21 Calculation method for design volume Simple Method Simple Method Simple Method Simple Method Simple Method DDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): -Difference in the entire site design volume and design volume for each SCM is provided for by excess volume in the bioretention facilities. -Other BUA not on subdivided lots consists of concrete pads, storage and other ancillary impervious surfaces required for the project. BIORETENTION CELL 1 1Drainage area number B3 B4 B5 2 IMinimumre uired treatment volume cu ft 2632 cf 2269 cf 2977 cf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? _ Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? No No No 7 Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes Yes Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) Pump (preferred) Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes Yes Yes 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? N/A N/A N/A 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes Yes BIORETENTION CELL MDC FROM 02H .1052 18 SHWT elevation (fmsl) N/A N/A N/A 19 Bottom of the bioretention cell (fmsl) 267.00 267.00 268.00 20 Ponding depth of the design storm (inches) 12 in 12 in 12 in 21 Surface area of the bioretention cell (square feet) 7420 sf 7420 sf 7420 sf 22 Design volume of SCM (cu ft) 6678 cf 6678 cf 6678 cf 23 Is the bioretention cell used for peak attenuation? No No No 24 Depth of peak attenuation over planting surface (in) N/A N/A N/A 25 Height of peak attenuation outlet above the planting surface (in) N/A N/A N/A 26 Infiltration rate of the in situ soil (inch/hour) 1 in/hr 1 in/hr 1 in/hr 27 Diameter of the underdrain pipes (if applicable) 4 in 4 in 4 in 28 Does the design include Internal Water Storage (IWS)? Yes Yes Yes 29 if so, elevation of the top of the IWS (fmsl) 265.5 265.5 266.5 30 Elevation of the planting surface (fmsl) 267 267 267 31 What type of vegetation will be planted? (grass, trees/shrubs, other)? Grass Grass Grass 32 Media depth (inches) 24 in 24 in 24 in 33 Percentage of medium to coarse washed sand by volume 85% 85% 85% 34 Percentage of fines (silt and clay) by volume 10% 10% 10% 35 Percentage of organic matter by volume 5% 5% 5% 36 Type of organic material Pine bark fines Pine bark fines Pine bark fines 37 Phosphorus Index (P-Index) of media (unitless) 10 10 10 38 Will compaction be avoided during construction? Yes Yes Yes 39 Will cell be maintained to a one inch/hour standard? Yes Yes Yes 40 Depth of mulch, if applicable (inches) N/A N/A N/A 41 IType of mulch, if applicable N/A N/A N/A 42 1 How many clean out pipes are being installed? 2 2 2 43 IType of pretreatment that will be used: Grass/gravel Grass/gravel Grass/gravel ADDITIONAL INFORMATION Please use this space to provide any additional information about 44 Ithe bioretention cell(s): -SHWT in excess of 25-feet during conducted soil borings. Bioretention 3 2:07 PM 11/16/2022 DRY POND 11 Drainage area number A 21 Minimum required treatment volume cu ft 16625 cf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion 10- ear storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Other 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC 8 ? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? N/A 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC 12 ? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM desi ned by an NC licensedprofessional? Yes DRY POND MDC FROM 02H .1062 18 SHWT elevation (fmsl) N/A 19 Elevation of the bottom of the dry pond (fmsl) 254 20 Distance from bottom to SHWT feet N/A 21 Elevation of the temporary pool during the design storm (feet) 256 ft 22 Ponding depth of the design storm feet 2 ft 23 Will the dry pond be uniformly graded to flow toward the outlet? Yes 24 Is a low flow channel being provided? No 25 Are the inlet(s) and outlet located in a manner that avoids short- c rcuitin ? Yes 26 Will berms or baffles be provided to increase the flowpath? No 27 What method of pretreatment will be provided? Forebay 28 Design volume of SCM cu ft 16625 29 Diameter of drawdown orifice (in) N/A 30 Drawdown time for the temporary pool hours 2.25 31 Does the pond minimize impacts to the receiving channel from the 1- r,24-hrstorm? Yes 32 Is there a small permanent pool near the orifice to prevent clo in ? Will the outlet be designed to prevent clogging? Are the dam and embankment planted in non -clumping turf grass? Yes 33 Yes 34 Yes 35 Species of turf that will be used on the dam and embankment See plans. 36 Will trees and shrubs be prevented from growing on the dam and embankment? Yes ADDITIONAL INFORMATION 37 Please use this space to provide any additional information about the dry pond(s): -Skimmer device to be utilized for SCM drawdown. -SHWT in excess of 25-feet during conducted soil borings. -Low-flow channel not being provided due to the presence of underdrains in the dry pond. -Underdrains utilized in lieu of drawdown orifice. Orifice holes utilized to control storm events beyond that of the design storm. Dry Pond 4 2:09 PM 11/16/2022