HomeMy WebLinkAboutWQ0039181_Renewal (Application)_20221129Initial Review
Reviewer Thornburg, Nathaniel D
Is this submittal an application? (Excluding additional information.)*
Yes No
Permit Number (IR) * WQ0039181
Applicant/Permittee Carolina Malt House, Inc
Applicant/Permittee Address 12969 Statesville Blvd Cleveland NC 27013
Is the owner in BIMS? Yes No Is the facility in BIMS?
Owner Type
Facility Name
County
Fee Category
Is this a complete application?*
Yes No
Signature Authority
Signature Authority Title
Signature Authority Email
Document Type (if non -application)
Email Notifications
Organization
Carolina Malt House WWTF
Rowan
Does this need review by the hydrogeologist? * Yes No
Regional Office
CO Reviewer
Admin Reviewer
llr�ore
Fee Amount $0
Complete App Date 11/29/2022
Below list any additional email address that need notification about a new project.
... ... ..
Email Address
Comments to be added to email notfication
Comments for Admin
Comments for RO
Comments for Reviewer
Comments for Applicant
Submittal Form
Project Contact Information
Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence.
............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
Name* mark van Wagenberg
Email Address*
mark@carolinamalt.com
Project Information
Application/Document Type*
New (Fee Required)
Modification - Major (Fee Required)
Renewal with Major Modification (Fee
Required)
Annual Report
Additional Information
Other
Phone Number*
7042139334
Modification - Minor
Renewal
GW-59, NDMR, NDMLR, NDAR-1,
N DAR-2
Residual Annual Report
Change of Ownership
We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form.
hftps://edocs.deq.nc.gov/Forms/NonDischarge_Monitoring_Report
Perm it Type:*
Wastewater Irrigation
High -Rate Infiltration
Other Wastewater
Reclaimed Water
Closed -Loop Recycle
Residuals
Single -Family Residence Wastewater
Other
Irrigation
Permit Number: *
WQ0039181
Has Current Existing permit number
Applicant/Permittee*
Carolina Malt House, Inc.
Applicant/Permittee Address*
12969 Statesville Blvd Cleveland NC 27013
Facility Name*
Carolina Malt House WWTF
Please provide comments/notes on your current submittal below.
We would like to renew our current wastewater permit and continue operating as is. Per our
conversation with Ed Watson at our most recent inspection we are looking into options as far
as expansion but need some additional time to work with soil scientist and engineer to develop
a plan for the future. Thanks!
At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg
at nathaniel.thornburg@ncdenr.gov.
Please attach all information required or requested for this submittal to be reviewed here. *
(Application Form, Engineering Plans, Specifications, Calculations, Etc.)
Carolina Malt House Permit Renewal 2022.pdf 2.91 MB
Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger
than upload limit.
* By checking this box, I acknowledge that I understand the application will not be
accepted for pre -review until the fee (if required) has been received by the Non -
Discharge Branch. Application fees must be submitted by check or money order and
made payable to the North Carolina Department of Environmental Quality (NCDEQ).
I also confirm that the uploaded document is a single PDF with all parts of the
application in correct order (as specified by the application).
Mail payment to:
NCDEQ — Division of Water Resources
Attn: Non -Discharge Branch
1617 Mail Service Center
Raleigh, NC 27699-1617
Signature
Submission Date 11/29/2022
DWR
State of North Carolina
Department of Environmental Quality
Division of Water Resources
Division of Water Resources
15A NCAC 02T .0500 — WASTEWATER IRRIGATION SYSTEM — RENEWAL
FORM: WWIS-R 02-21
Pursuant to 15A NCAC 02T .0107(b), if the application does not include all required information and the necessary supporting
documentation, the application shall be returned. The application and attachments shall be prepared in accordance with 15A
NCAC 02T .0100, 15A NCAC 02T .05009 and Division Policies. For more information, visit the Water Quality Permitting
Section's Non -Discharge Branch website. The Applicant shall submit an electronic copy of the application and attachments
uploaded as a single Portable Document Format (PDF) file to
httils://edocs.deU.nc.goy/Forms/NonDischarge-Branch-Submittal-Form-Ver2, or emailed to
Non-Dischar2e.Renortsnncdenr.2ov if less than 20 megabytes (MB).
SECTION I —APPLICANT INFORMATION
I.
Applicant: Aaron Goss
2.
Permit No.: WQ00 39181
_V1 174 �
Title: President
3.
Signature authority:
Phone number: (704) 412 - 9962
Email: Aaron@carolinamalt.com
4.
Mailing address: 12969 Statesville Blvd
City: Cleveland
State: NC Zip: 27013 -
5.
Contact person: Mark van Wagenberg
Email: mark@carolinamalt.com
Primary phone number: (704) 213-9334
Secondary phone number: ( ) -
MW SECTION II — FACILITY INFORMATION
1. Physical address: 12969 Statesville Blvd County:Rowan Parcel No.: 265 001
City: Cleveland
2. Treatment facility coordinates to the sixth decimal degree:
Latitude: Longitude:-80.71476 °
35.73871 °
State: NC
Zip: 27013 -
Method: map interpretation by extraction
SECTION III —FLOW INF TION
1.
Permitted flow: 6,053
GPD (The maximum allowable flow based on what has been permitted)
2.
As -built flow: 6,053
GPD (The maximum allowable flow based on what has been constructed)
3.
Average flow: 5,378
GPD (The average of all reported flows on the previous calendar year's NDMRs)
4.
Hydraulic capacity:.89
% (Divide the average flow in Item 3 by the As -built flow in Item 2)
5.
Wastewater composition:
Domestic : % Industrial: 100 % Stormwater: %
0 SECTION IV — BILLING INFORMATION
1. Billing address: 12969 Statesville Blvd
City: Cleveland State: NC Zip: 27013 -
2. Verify the Applicant does not have any overdue annual fees:
hops://deQ. nc. 2ov/about/divisions/water-resources/water-resources-permits/wq-ebavments
FORM: WWIS-R 02-21 Page 1 of 6
Pursuant to 15A NCAC 02T .0120(c), permits for renewing facilities shall not be granted if the Applicant or any affiliation has
an unpaid annual fee.
FORM: WWIS-R 02-21 Page 2 of 6
SECTION V — OPERATOR IN RESPONSIBLE CHARGE (ORC) INFORMATION
1. ORC: Lynn Aldrigdge
Grade: SI Certification No.: 993778
Mailing address: 1200 Crossover ridge Dr.
City: Salisbury
State: NC Zip: 28147 -
Phone number: (704) 431- 5266
Email:rowanwastewater@gmail.com
2. Back -Up ORC: Mark van Wagenberg
Grade: SI Certification No.: 1006711
Mailing address: 12969 Statesville Blvd
City: Cleveland
State: NC Zip: 27013 -
Phone number: ( 704 ) 213 - 9334
Email: mark@carolinamalt.com
SECTION VI — OPEN -ATMOSPHERE STRUCTURES
1. List all open -atmosphere treatment and storage structures associated with the renewing permit. Attach additional sheets if
necessary.
Type
Parcel No.
Volume (gal)
Liner Type
Freeboard (ft)
Latitude
Longitude
lagoon
265 001
366,281
synthetic
2ft
35.738 0
-80.715 °
0
0
0
0
0
0
SECTION VII — RELATED PERMITS
1. List all wastewater permits (i.e., sewer, collection system, NPDES, residuals) that have interactions with the renewing permit.
Attach additional sheets if necessary.
Permit Type
Permit No.
Relationship Type
wastewater irrigation system
WQ0039181
LWAN SECTION VIII — AFNITORING
WELLS
I. List all groundwater monitoring wells associated with the renewing permit. Attach additional sheets if necessary.
Well Name
Parcel No.
Status
Gradient
Location
Latitude
Longitude
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
O
0
FORM: WWIS-R 02-21 Page 3 of 6
ML SECTION IX — IRRIGATION FIELDS
1. List all irrigation fields associated with the renewing permit. Attach additional sheets if necessary.
Field
County
Parcel No.
Deeded Owner
Area
Cover Crop
Latitude
Longitude
1
Rowan
265 001
Amber Waves Holdings,
LLC
1.1
Fescue
5.737260
-80.713600
0
2A
Rowan
265 001
Amber Waves Holdings,
LLC
1.1
Fescue
35.7385760
80.713262
0
2B
Rowan
265 001
Amber Waves Holdings,
LLC
1.0
Fescue
35.737990°
80.712133
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
FORM: WWIS-R 02-21 Page 4 of 6
O O
O O
Total Acreage:
3.2:::::6
ATTACHMENT g- SITE MAP
Was the facility originally permitted or had a major modification issued after September 1, 2006?
❑ ❑ Yes - Pursuant to 15A NCAC 02T .0105(d), submit a site map pursuant to the requirements in 15A NCAC 02T .0504(d).
These requirements are:
❑ A scaled map of the site with topographic contour intervals not exceeding 10 feet or 25 percent of total site relief and
showing all facility -related structures and fences within the wastewater treatment, storage, and irrigation areas.
❑ Soil mapping units shown on all irrigation sites.
❑ The location of all wells (including usage and construction details if available), streams (ephemeral, intermittent, and
perennial), springs, lakes, ponds, and other surface drainage features within 500 feet of all wastewater treatment, storage,
and irrigation sites.
❑ Delineation of the compliance and review boundaries per 15A NCAC 02L .0107 and .0108, and 15A NCAC 02T .0506(c)
if applicable.
❑ Setbacks as required by 15A NCAC 02T .0506.
❑ Site property boundaries within 500 feet of all wastewater treatment, storage, and irrigation sites.
❑ All habitable residences or places of public assembly within 500 feet of all treatment, storage, and irrigation sites.
❑ ❑ No - Skip Attachment A.
ATTACHMENT B - SIGNATURE AUTHORITY DELEGATION
Does the signature authority in Section I, Item 3 meet the requirements pursuant to 15A NCAC 02T .0106(b)? ❑
❑ ❑ Yes - Skip Attachment B.
❑ No - Submit a delegation letter pursuant to 15A NCAC 02T .0106(c) authorizing the signature authority to sign.
ATTACHMENT C - FLOW REDUCTION
Does the existing permit include an approved flow reduction'?
❑ ❑ Yes - Submit a copy of the flow reduction approval letter, as well as the measured monthly average amount of wastewater
flow contributed per unit for the 12 months prior to permit renewal. If any of these monthly averages are within 20% of the
approved flow reduction value, the Permittee shall provide a reevaluation of the reduced flow value pursuant to the
requirements in 15A NCAC 02T .0I14(f).
❑ ❑ No - Skip Attachment C.
EL —ATTACHMENT D - CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY I
Is the Applicant a Privately -Owned Public Utility? ❑
❑ ❑ Yes - Pursuant to 15A NCAC 02T .0115(a)(1), submit the Certificate of Public Convenience and Necessity from the North
Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise.
❑ No - Skip Attachment D.
ATTACHMENT E - OPERATIONAL AGREEMENT
Is the Applicant a Home/Property Owners' Association or Developer of Lots to be Sold'? ❑
❑ ❑ Yes (Home/Property Owners' Association) - Pursuant to 15A NCAC 02T .0115(a)(2), submit an executed Operational
Agreement (FORM: HOA). Pursuant to 15A NCAC 02T .0I15(c), if the applicant is a legally formed Homeowners' or Property
Owner's Association, submit a copy of the Articles of Incorporation, Declarations, and By-laws.
❑ ❑ Yes (Developer of Lots to be Sold) - Pursuant to 15A NCAC 02T .0115(a)(21, submit an executed Operational Agreement
(FORM- DEV). Pursuant to 15A NCAC 02T _0115(2), if the applicant is a developer of lots to be sold, submit a copy of the
Articles of Incorporation, Declarations, and By-laws.
❑ No - Skip Attachment E.
FORM: WWIS-R 02-21 Page 5 of 6
FORM: WWIS-R 02-21 Page 6 of 6
ATTACHMENT F — DEMONSTRATION OF FUTURE WASTEWATER TREATMENT CAPACITIES
Is the applicant a municipality, county, sanitary district, or public utility?
❑ ❑ Yes — Proceed to the next question.
❑ ❑ No — Skip Attachment F.
Does the hydraulic capacity in Section III, Item 4 exceed 70%'?
❑ ❑ Yes (the hydraulic capacity is greater than 70%, but less than 80%) — Pursuant to 15A NCAC 02T .0118(l), prior to
exceeding 80 percent of the system's permitted hydraulic capacity (based on the average flow during the last calendar year), the
permittee shall submit an engineering evaluation of their future wastewater treatment, utilization, and disposal needs. This
evaluation shall outline plans for meeting future wastewater treatment, utilization, or disposal needs by either expansion of the
existing system, elimination or reduction of extraneous flows, or water conservation and shall include the source of funding for
the improvements. If expansion is not proposed or is proposed for a later date, a justification shall be made that wastewater
treatment needs will be met based on past growth records and future growth projections, and as appropriate, shall include
conservation plans or other measures to achieve waste flow reductions.
❑ ❑ Yes (the hydraulic capacity greater than 80%) — Proceed to the next question.
❑ ❑ No — Skip Attachment F.
If answered Yes above, does the hydraulic capacity in Section III, Item 4 exceed 80%?
❑ ❑ Yes (the hydraulic capacity is greater than 80%) — Pursuant to 15A NCAC 02T .0118(2), prior to exceeding 90 percent of the
system's permitted hydraulic capacity (based on the average flow during the last calendar year), the permittee shall obtain all
permits needed for the expansion of the wastewater treatment, utilization, or disposal system and, if construction is needed,
submit final plans and specifications for expansion, including a construction schedule. If expansion is not proposed or is
proposed for a later date, a justification shall be made that wastewater treatment needs will be met based on past growth records
and future growth projections, and as appropriate, shall include conservation plans or other specific measures to achieve waste
flow reductions.
❑ ❑ No — Skip Attachment F.
TTACHMENT G — EASEMENT, ENC4ACHMENT, AND LEASE AGREEMENTS
Does the Permittee own all of the land associated with the wastewater collection, treatment, conveyance, and irrigation system?
❑ ❑ Yes — Skip Attachment G.
❑ ❑ No —Pursuant to 15A NCAC 02T .0116(c), provide a copy of all easements, lease agreements, and encroachment agreements
allowing the Permittee to operate and maintain the wastewater collection, treatment, conveyance, and irrigation system on
property not owned by the Permittee.
H — AFFILIATIONS
Are the Permittee's affiliations of record correct'? Check affiliations.
❑ ❑ Yes — Skip Attachment H.
❑ ❑ No — Provide the corrected affiliations and their contact information.
ATTACHMENT I — COMPLIANCE SCHEDULES
Does the existing permit include any Compliance Schedules? (See Section I of the most recently issued permit)
❑ ❑ Yes — Submit documentation that the compliance schedules have been met.
❑ ❑ No — Skip Attachment I.
ATTACHMENT J — CIVIL PENALTIES AND (STANDING VIOLATIONS
Does the Permittee have any existing civil penalties or outstanding violations?
❑ ❑ Yes (civil penalties) — Submit payment for the civil penalty, or proof of remission request.
❑ ❑ Yes (violations) — Submit a copy of your response to the Notice of Violation.
❑ ❑ No — Skip Attachment J.
FORM: WWIS-R 02-21 Page 7 of 6
ATTACHMENT K — INDUSTRIAL WASTEWATER
Does the wastewater composition in Section III, Item 5 include any industrial wastewater?
❑ ❑ Yes — Proceed to the next question.
❑ ❑ No — Skip Attachment K.
Has the nature of the industrial wastewater changed since the last permit issuance (i.e., changes in industrial process, introduction
of new materials or chemicals, etc.)?
❑ ❑ Yes — Provide a chemical analysis of the wastewater pursuant to the requirements in 15A NCAC 02T .0504(hl. Provide an
overview of the manufacturing process; an inventory of all chemical and biological materials used in the manufacturing
process; and an overview of the cleaning and treatment methodology.
❑ ❑ No — Provide an overview of the manufacturing process; an inventory of all chemical and biological materials used in the
manufacturing process; and an overview of the cleaning and treatment methodology.
Our manufacturing process has not changed; it consists only of water and small grains.
ATTACHMENT L— SETBACK WAIVERS
Does the existing permit include setback waivers?
❑ ❑ Yes — Pursuant to 15A NCAC 02T .0506(d), provide setbacks waivers that have been written, notarized, signed by all parties
involved, and recorded with the county Register of Deeds. Waivers involving the compliance boundary shall be in accordance
with 15A NCAC 02L .0107 .
❑ ❑ No — Skip Attachment L.
APPLICANT'S CERTIFICATION
I, hoso& attest that this application
(Signature authority's name as noted in Section I, Item 3)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this
application package are not completed, and that if all required supporting information and attachments are not included, this
application package will be returned as incomplete. I further certify pursuant to 15A NCAC 02T .0120(bl, that the applicant, or
any parent, subsidiary, or other affiliate of the applicant has: not been convicted of environmental crimes under; not previously
abandoned a wastewater treatment facility without properly closing the facility; not paid a civil penalty; not been compliant with
any compliance schedule in a permit, settlement agreement, or order; not paid an annual fee.
Note: The Applicant's Certification shall be signed pursuant to 15A NCAC 02T .0106(bl. An alternate person may be delegated as
the signing official if a letter is provided pursuant to 15A NCAC 02T .0106(c). Pursuant to § 143-215.6A and § 143-215.6B, any
person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a
Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature:
Date: 11-20-22
THE COMPLETED APPLICATION AND ATTACHMENTS SHALL BE SUBMITTED AS A SINGLE PDF FILE VIA:
Email:
Non-Discharge.Reportskncdenr. gov
Laserfiche Upload:
http s:Hedocs.deU.nc. goy/Forms/NonDischarge-Branch-Sub
mittal-Form-Ver2
FORM: WWIS-R 02-21 Page 8 of 6
SUPPLEMENTAL SOIL AND SITE EVALUATION
Carolina Malt House
Cleveland, North Carolina
Prepared For:
Carolina Malt House
12969 Statesville Boulevard
Cleveland, NC 27013
Prepared By:
Thompson
Environmental
Consulting
t�'f'�TER • 't��'1STE�'ATER • �l'F,TI,.1 � [ tti
Thompnson Environmental Consulting, Inc.
PO Box 541
Midland, NC 28107
July 4, 2020
Afc54A'+ ptvner
INTRODUCTION
Thompson Environmental Consulting (TEC) has been retained by the Carolina Malt House to perform
a supplemental soil and site evaluation of their property located at 12969 Statesville Boulevard,
Cleveland, NC 27013 (Rowan County Parcel Number: 265 001).
The purpose of this evaluation is to confirm that the soil and site conditions have not changed since
our October 1, 2015 report.
SITE DESCRII'TION AND INVESTIGATION METHODOLOGY
The study area is comprised of 18.73 acres of open fields and woods, and is currently used for a
commercial barley malting operation and spray irrigation of the wastewater generated from the
steeping process.
Soil borings were advanced with a hand -auger and soil color was determined with a MunseIl Soil
Color Chart. Observations of the landscape (slope, drainage patterns, etc.) as well as soil properties
(depth, texture, structure, soil wetness, restrictive horizons, etc.) were recorded. Each soil boring was
located in the field using a hand-held GPS unit.
SOIL EVALUATION
A supplemental field survey was conducted on July 4, 2020, by Larry Thompson, LSS. Five (5) soil
borings were advanced at various locations throughout the property and their locations noted on
Figure 1. The soil units described in our 2015 report have not changed and do not appear to be
hydraulically overloaded.
CONCLUSION
The findings presented herein represent TEC's professional opinion based upon our site evaluation
and knowledge of the current laws and regulations governing on -site wastewater systems in North
Carolina (Section .1900 of the North Carolina Administrative Code —NCAC and Title 15A
Subchapter 2T).
Soils naturally change across a landscape and contain many inclusions. As such, attempts to quantify
them are not always precise and exact. Due to this inherent variability of soils and the subjectivity
when determining limiting factors, there is no guarantee that a regulating authority will agree with the
findings of this report. Any concurrence with the findings of this report would be made by the
appropriate permitting agency at the time permit modifications are issued.
Carolina Mall House 2 July 4, 2020
Date:
ThompSoil Boring Locations July 2020 Figure
Enyison prepared For: ronmenta Carolina Malt House Scale:
Consuifi p SO 1fi0ft
Carolina Malt 12969 Statesville Boulevard 1+
House Cleveland, IVC 27013
EC Job #:
Rowan County 20-85
Spray Irrigation Design Elements
Drip Irrigation Design Elements
Nozzle wetted diameter:
108 ft
Emitter wetted area:
ft2
Nozzle wetted area:
4,486 ft'-
Distance between laterals:
ft
Nozzle capacity:
8.38 GPM
Distance between emitters:
ft
Nozzle manufacturer/model:
Senninger / 50 Series
Emitter capacity:
GPH
Elevation of highest nozzle:
765 ft
Emitter manufacturer/model:
1
Specification Section:
See Irrigation Section
(drawings)
Elevation of highest emitter:
ft
Specification Section:
VIII. SETBACKS — 15A NCAC 02T .0506:
I. Does the project comply with all setbacks found in the river basin rules (15A NCAC 02B .0200)? ® Yes or ❑ No
If no. list non -compliant setbacks:
2. Have any setback waivers been obtained in order to comply with 15A NCAC 02T .506 a and .05OfiJJb? ® Yes or ❑ No
If yes, have these waivers been written, notarized and signed by all parties involved and recorded with the County Register of
Deeds? ® Yes or ❑ No
3. Provide the minimum field observed distances (ft) for each setback parameter to the irrigation system and treatment/storage
units (NOTE — Distances greater than 500 feet may be marked N/A):
Setback Parameter
Irrigation
System
Treatment /
tnra a Unit
Any habitable residence or place of assembly under separate ownership or not to be
maintained as part of the project site
N/A
N/A
Any habitable residence or place of assembly owned by the Permittee to be maintained as
art of the project site
N/A
Any private or public water supply source
256'
190,
Surface waters (streams — intermittent and perennial. perennial waterbodies, and wetlands)
100'
Groundwater lowering ditches (where the bottom of the ditch intersects the SHWT)
N/A
Subsurface groundwater lowering drainage systems
N/A
Surface water diversions (ephemeral streams, waterways, ditches)
25'
Any well with exception of monitoring wells
256'
205'
Any property line
150'
54'
Top of slope of embankments or cuts of two feet or more in vertical height
75'
Any water line from a disposal system
N/A
Any swimming pool
N/A
Public right of way
50'
Nitrification field
NIA
Any building foundation or basement
82'
Impounded public water supplies
N/A
Public shallow groundwater supply (less than 50 feet deep)
NIA
4. Does the Applicant intend on complying with 15A NCAC 02T .0506(c) in order to have reduced irrigation setbacks to
property lines? ❑ Yes or ® No
If yes, complete the following table by providing the required concentrations as determined in the Engineering Calculations:
PC)Pk - WWrcn6,1h Page 12 of 12
;,• `- N __� Parcel Boundary
1
StudyArea
® Ksat Locations �
Soil Unit 1 (Pacolet)
��Y]f Soil unit 2
Budding
slSo
Basin Footpnnt
; Ksats 14115 Potential Jurisdictional
4. Feature Edge
-Stream
Ksais 12113 ` 100-Foot Buffer
4 A 5.78 acres 25-Foot Buffer
Ksat 10
!•w-. - DO*- Gulley
® Well
acres Ksat s PA
Ksat 11Ks3ts 1;2
Al
A.
Ksats 314��` 2.1 acres
�, yet• a� F
Ksats 6/6
V
r
'k1 T� � �F, .'4 a lam' �•- 1 _
AV
•'+" fff
�•• � �._ . ��, ,R•nf `fit ,} .- +L�• t?�n -
F
Yj
Thompson
Environments
$%
Consulting
NC QneMap. NO Center for Geographic Information and Analysis NO
911 Board '
Carolina Malt House
Hydraulic Conductivity
Testing Map
Rowan County, North Carolina
Date.
January 2017
scar--
0 75 150 Feet
L • 1
Job No.
Figure
4
1 1
Page 10 of 27
' # + A r
j'"'• ti'1ia•: (0 OpenSt',&efMap {and)
contributdrs CC -BY -SA
r
I
J'
�i
LISGS The National Map National 866r7dar*s Dataset. National
Elevation Dataset Geographir, Nam ,Information System, National
Hydrography Dataset. National Land ver Database. Nat;Qndl
Parcel Boundary 1
Structures Dataset, and National Tra(ispbrtat!nn Dataset. U S Census
Bureau - TIGER/Line. HERE Road 5�tg
Thompson
Environments
Consulting
Carolina Malt House
USGS Topo Map
Rowan County, North Carolina
Date Figure
January 2017
Scale
0 750 1.500 Feet
L I
Page 7 or27
Thompson
Environments
Consulting
Date
Carolina Malt House January 2017
Scale
USDA-NRCS Soils Map 0 1a7 5 275 Feet
Figure
2
Rowan County, North Carolina
Page 8 of 27
N Parcel Boundary
�. ._ StudyArea
Soil Borings
Soil Unit 1 (Pacolet)
t q ' Soil Unit 2
Unsuitable
Ot Soil Unit 1 (Pacolet)
sky' bi Soil Unit 2
b 13 Building
Silo
F'1 ' Basin Footprint
" Potential Jurisdictional
b2 Feature Edge
A-, �.� Stream
15 78 acres 100-Foot Buffer
2 67 acres
b12 25-Foot Buffer
//F
►I- Gulley
dcres well
S.
S . 1
.-
b7
VIA
NC QneMap• NC Center for Geographic Information and Analysis ej
513 Board
Thompson
Environments
Consulting
Carolina Malt House
Delineated Soil Units Map
]ate Figure
January 2017
scale
0 m, m Xee.
3
Rowan County, North Carolina
Page 9 oF27
9. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is
not the Permittee and owns land within the compliance boundary shall execute and file with the Rowan
County Register of Deeds an easement running with the land containing the following items:
a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1);
b. Prohibits construction and operation of water supply wells within the compliance boundary; and
c. Reserves the right of the Permittee or the State to enter the property within the compliance boundary
for purposes related to the permit.
The Director may terminate the easement when its purpose has been fulfilled or is no longer needed.
[15A NCAC 02L .0107(f)]
10. The facilities permitted herein shall be constructed according to the following setbacks:
a. The setbacks for spray irrigation sites permitted under 15A NCAC 02T .0500 shall be as follows
(all distances in feet):
i. Any habitable residence or place of public assembly under separate ownership: 400200
ii. Any habitable residence or place of public assembly owned by the Permittee: 100
iii. Any private or public water supply source: 100
iv. Surface waters: 100
v. Groundwater lowering ditches:
vi. Surface water diversions:
vii. Any well with exception of monitoring wells:
25
100
150'
viii. Any property line:
15
ix. Top of slope of embankments or cuts of two feet or more in vertical height: 10
x. Any water line from a disposal system: 100
xi. Subsurface groundwater lowering drainage systems: 100
xii. Any swimming pool: 50
xiii. Public right of way: 20
xiv. Nitrification field: 15
xv. Any building foundation or basement:
' Per a setback waiver recorded in the Rowan County Register of Deeds, setbacks from the
wetted area to any property line has been reduced for the following:
Parcel No. Deed Book 1 Page Setback
265-001 1288 / 420 0 feet
263-009 1288 / 420 0 feet
Easement
150 feet
150 feet
[l5A NCAC 02T .0506(a)}
its permitted under 15A NCAC 02T .0500 shall be as follows (all
b. The setbacks for storage un
distances in feet):
i. Any habitable residence or place of public assembly under separate ownership:
ii. Any private or public water supply source:
iii. Surface waters:
iv. Any well with exception of monitoring wells:
v. Any property line:
[15A NCAC 02T .0506(b)]
100
100
50
100
50
WQ0039181 Version 1.D
Shell Version 151201 Page 3 of 9
�'v A
b-I
b2
a sir 'Af
2 67 acres
b b3 3
acres
A.
Thompson
EnvifonmentaS
Consulting
N Parcel Boundary
StudyArea
Soil Borings
Oil
Soil Unit 1 (Pacolet)
Soil Unit 2
Unsuitable
Soil Unit I (Pacolet)
Soil Unit 2
Building
Sslo
ib
..A
W
N, Basin Footprint
A Potential Jurisdictional
'
Feature Edge
Stream
5 78 acres I 00-Foot Buffer
b12 25-Foot Buffer
DODO- Gulley
1511
b7
it
NC One Map. NC Center for Geographic Informatton and Ana',
911 Board
Carolina Malt House
Delineated Soil Units Map
Rowan County, North Carolina
=11
)ate January 2017sgle
Figure
Paw 9 (W27
K
r Ksats 141i5
?�- Ksats 12113
5 78 acres
Ksal 10
i AYr� �•� ,�'
.� V : 2 of acres Ksat 9
. a;;f'S �� Ksat 11
�'A A
Ksats 112
st r Vie, ��. " Ksats 71S
I
4
`
Ksats 314.�".1 acres 2
" } Ksats516+
,.% .
•^tat,
�,
.t {:
"• �9
Thompsw
Environment*
Consulting
Parcel Boundary
StudyArea
Ksat Locations
Soil Unit 1 (Paoolet)
Soil Unit 2
Building
Silo
Basin Footprint
Potential Jurisdictional
Feature Edge
Stream
100•-Foot Buffer
25-Foot Buffer
POP- Gulley
E" Well
�► '`err .
NC OneMap, NC Center for Geographic Information and_A,"Iysis. NC
911 Board 4
Carolina Malt House
Hydraulic Conductivity
Testing Map
Rowan County, North Carolina
le: Figure
January 20t 7
ale
0 75 150 F"
! No.: 4
Page 10 of 27