Loading...
HomeMy WebLinkAboutWQ0039181_Renewal (Application)_20221129Initial Review Reviewer Thornburg, Nathaniel D Is this submittal an application? (Excluding additional information.)* Yes No Permit Number (IR) * WQ0039181 Applicant/Permittee Carolina Malt House, Inc Applicant/Permittee Address 12969 Statesville Blvd Cleveland NC 27013 Is the owner in BIMS? Yes No Is the facility in BIMS? Owner Type Facility Name County Fee Category Is this a complete application?* Yes No Signature Authority Signature Authority Title Signature Authority Email Document Type (if non -application) Email Notifications Organization Carolina Malt House WWTF Rowan Does this need review by the hydrogeologist? * Yes No Regional Office CO Reviewer Admin Reviewer llr�ore Fee Amount $0 Complete App Date 11/29/2022 Below list any additional email address that need notification about a new project. ... ... .. Email Address Comments to be added to email notfication Comments for Admin Comments for RO Comments for Reviewer Comments for Applicant Submittal Form Project Contact Information Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence. ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ Name* mark van Wagenberg Email Address* mark@carolinamalt.com Project Information Application/Document Type* New (Fee Required) Modification - Major (Fee Required) Renewal with Major Modification (Fee Required) Annual Report Additional Information Other Phone Number* 7042139334 Modification - Minor Renewal GW-59, NDMR, NDMLR, NDAR-1, N DAR-2 Residual Annual Report Change of Ownership We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form. hftps://edocs.deq.nc.gov/Forms/NonDischarge_Monitoring_Report Perm it Type:* Wastewater Irrigation High -Rate Infiltration Other Wastewater Reclaimed Water Closed -Loop Recycle Residuals Single -Family Residence Wastewater Other Irrigation Permit Number: * WQ0039181 Has Current Existing permit number Applicant/Permittee* Carolina Malt House, Inc. Applicant/Permittee Address* 12969 Statesville Blvd Cleveland NC 27013 Facility Name* Carolina Malt House WWTF Please provide comments/notes on your current submittal below. We would like to renew our current wastewater permit and continue operating as is. Per our conversation with Ed Watson at our most recent inspection we are looking into options as far as expansion but need some additional time to work with soil scientist and engineer to develop a plan for the future. Thanks! At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg at nathaniel.thornburg@ncdenr.gov. Please attach all information required or requested for this submittal to be reviewed here. * (Application Form, Engineering Plans, Specifications, Calculations, Etc.) Carolina Malt House Permit Renewal 2022.pdf 2.91 MB Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger than upload limit. * By checking this box, I acknowledge that I understand the application will not be accepted for pre -review until the fee (if required) has been received by the Non - Discharge Branch. Application fees must be submitted by check or money order and made payable to the North Carolina Department of Environmental Quality (NCDEQ). I also confirm that the uploaded document is a single PDF with all parts of the application in correct order (as specified by the application). Mail payment to: NCDEQ — Division of Water Resources Attn: Non -Discharge Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Signature Submission Date 11/29/2022 DWR State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02T .0500 — WASTEWATER IRRIGATION SYSTEM — RENEWAL FORM: WWIS-R 02-21 Pursuant to 15A NCAC 02T .0107(b), if the application does not include all required information and the necessary supporting documentation, the application shall be returned. The application and attachments shall be prepared in accordance with 15A NCAC 02T .0100, 15A NCAC 02T .05009 and Division Policies. For more information, visit the Water Quality Permitting Section's Non -Discharge Branch website. The Applicant shall submit an electronic copy of the application and attachments uploaded as a single Portable Document Format (PDF) file to httils://edocs.deU.nc.goy/Forms/NonDischarge-Branch-Submittal-Form-Ver2, or emailed to Non-Dischar2e.Renortsnncdenr.2ov if less than 20 megabytes (MB). SECTION I —APPLICANT INFORMATION I. Applicant: Aaron Goss 2. Permit No.: WQ00 39181 _V1 174 � Title: President 3. Signature authority: Phone number: (704) 412 - 9962 Email: Aaron@carolinamalt.com 4. Mailing address: 12969 Statesville Blvd City: Cleveland State: NC Zip: 27013 - 5. Contact person: Mark van Wagenberg Email: mark@carolinamalt.com Primary phone number: (704) 213-9334 Secondary phone number: ( ) - MW SECTION II — FACILITY INFORMATION 1. Physical address: 12969 Statesville Blvd County:Rowan Parcel No.: 265 001 City: Cleveland 2. Treatment facility coordinates to the sixth decimal degree: Latitude: Longitude:-80.71476 ° 35.73871 ° State: NC Zip: 27013 - Method: map interpretation by extraction SECTION III —FLOW INF TION 1. Permitted flow: 6,053 GPD (The maximum allowable flow based on what has been permitted) 2. As -built flow: 6,053 GPD (The maximum allowable flow based on what has been constructed) 3. Average flow: 5,378 GPD (The average of all reported flows on the previous calendar year's NDMRs) 4. Hydraulic capacity:.89 % (Divide the average flow in Item 3 by the As -built flow in Item 2) 5. Wastewater composition: Domestic : % Industrial: 100 % Stormwater: % 0 SECTION IV — BILLING INFORMATION 1. Billing address: 12969 Statesville Blvd City: Cleveland State: NC Zip: 27013 - 2. Verify the Applicant does not have any overdue annual fees: hops://deQ. nc. 2ov/about/divisions/water-resources/water-resources-permits/wq-ebavments FORM: WWIS-R 02-21 Page 1 of 6 Pursuant to 15A NCAC 02T .0120(c), permits for renewing facilities shall not be granted if the Applicant or any affiliation has an unpaid annual fee. FORM: WWIS-R 02-21 Page 2 of 6 SECTION V — OPERATOR IN RESPONSIBLE CHARGE (ORC) INFORMATION 1. ORC: Lynn Aldrigdge Grade: SI Certification No.: 993778 Mailing address: 1200 Crossover ridge Dr. City: Salisbury State: NC Zip: 28147 - Phone number: (704) 431- 5266 Email:rowanwastewater@gmail.com 2. Back -Up ORC: Mark van Wagenberg Grade: SI Certification No.: 1006711 Mailing address: 12969 Statesville Blvd City: Cleveland State: NC Zip: 27013 - Phone number: ( 704 ) 213 - 9334 Email: mark@carolinamalt.com SECTION VI — OPEN -ATMOSPHERE STRUCTURES 1. List all open -atmosphere treatment and storage structures associated with the renewing permit. Attach additional sheets if necessary. Type Parcel No. Volume (gal) Liner Type Freeboard (ft) Latitude Longitude lagoon 265 001 366,281 synthetic 2ft 35.738 0 -80.715 ° 0 0 0 0 0 0 SECTION VII — RELATED PERMITS 1. List all wastewater permits (i.e., sewer, collection system, NPDES, residuals) that have interactions with the renewing permit. Attach additional sheets if necessary. Permit Type Permit No. Relationship Type wastewater irrigation system WQ0039181 LWAN SECTION VIII — AFNITORING WELLS I. List all groundwater monitoring wells associated with the renewing permit. Attach additional sheets if necessary. Well Name Parcel No. Status Gradient Location Latitude Longitude 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 FORM: WWIS-R 02-21 Page 3 of 6 ML SECTION IX — IRRIGATION FIELDS 1. List all irrigation fields associated with the renewing permit. Attach additional sheets if necessary. Field County Parcel No. Deeded Owner Area Cover Crop Latitude Longitude 1 Rowan 265 001 Amber Waves Holdings, LLC 1.1 Fescue 5.737260 -80.713600 0 2A Rowan 265 001 Amber Waves Holdings, LLC 1.1 Fescue 35.7385760 80.713262 0 2B Rowan 265 001 Amber Waves Holdings, LLC 1.0 Fescue 35.737990° 80.712133 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FORM: WWIS-R 02-21 Page 4 of 6 O O O O Total Acreage: 3.2:::::6 ATTACHMENT g- SITE MAP Was the facility originally permitted or had a major modification issued after September 1, 2006? ❑ ❑ Yes - Pursuant to 15A NCAC 02T .0105(d), submit a site map pursuant to the requirements in 15A NCAC 02T .0504(d). These requirements are: ❑ A scaled map of the site with topographic contour intervals not exceeding 10 feet or 25 percent of total site relief and showing all facility -related structures and fences within the wastewater treatment, storage, and irrigation areas. ❑ Soil mapping units shown on all irrigation sites. ❑ The location of all wells (including usage and construction details if available), streams (ephemeral, intermittent, and perennial), springs, lakes, ponds, and other surface drainage features within 500 feet of all wastewater treatment, storage, and irrigation sites. ❑ Delineation of the compliance and review boundaries per 15A NCAC 02L .0107 and .0108, and 15A NCAC 02T .0506(c) if applicable. ❑ Setbacks as required by 15A NCAC 02T .0506. ❑ Site property boundaries within 500 feet of all wastewater treatment, storage, and irrigation sites. ❑ All habitable residences or places of public assembly within 500 feet of all treatment, storage, and irrigation sites. ❑ ❑ No - Skip Attachment A. ATTACHMENT B - SIGNATURE AUTHORITY DELEGATION Does the signature authority in Section I, Item 3 meet the requirements pursuant to 15A NCAC 02T .0106(b)? ❑ ❑ ❑ Yes - Skip Attachment B. ❑ No - Submit a delegation letter pursuant to 15A NCAC 02T .0106(c) authorizing the signature authority to sign. ATTACHMENT C - FLOW REDUCTION Does the existing permit include an approved flow reduction'? ❑ ❑ Yes - Submit a copy of the flow reduction approval letter, as well as the measured monthly average amount of wastewater flow contributed per unit for the 12 months prior to permit renewal. If any of these monthly averages are within 20% of the approved flow reduction value, the Permittee shall provide a reevaluation of the reduced flow value pursuant to the requirements in 15A NCAC 02T .0I14(f). ❑ ❑ No - Skip Attachment C. EL —ATTACHMENT D - CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY I Is the Applicant a Privately -Owned Public Utility? ❑ ❑ ❑ Yes - Pursuant to 15A NCAC 02T .0115(a)(1), submit the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise. ❑ No - Skip Attachment D. ATTACHMENT E - OPERATIONAL AGREEMENT Is the Applicant a Home/Property Owners' Association or Developer of Lots to be Sold'? ❑ ❑ ❑ Yes (Home/Property Owners' Association) - Pursuant to 15A NCAC 02T .0115(a)(2), submit an executed Operational Agreement (FORM: HOA). Pursuant to 15A NCAC 02T .0I15(c), if the applicant is a legally formed Homeowners' or Property Owner's Association, submit a copy of the Articles of Incorporation, Declarations, and By-laws. ❑ ❑ Yes (Developer of Lots to be Sold) - Pursuant to 15A NCAC 02T .0115(a)(21, submit an executed Operational Agreement (FORM- DEV). Pursuant to 15A NCAC 02T _0115(2), if the applicant is a developer of lots to be sold, submit a copy of the Articles of Incorporation, Declarations, and By-laws. ❑ No - Skip Attachment E. FORM: WWIS-R 02-21 Page 5 of 6 FORM: WWIS-R 02-21 Page 6 of 6 ATTACHMENT F — DEMONSTRATION OF FUTURE WASTEWATER TREATMENT CAPACITIES Is the applicant a municipality, county, sanitary district, or public utility? ❑ ❑ Yes — Proceed to the next question. ❑ ❑ No — Skip Attachment F. Does the hydraulic capacity in Section III, Item 4 exceed 70%'? ❑ ❑ Yes (the hydraulic capacity is greater than 70%, but less than 80%) — Pursuant to 15A NCAC 02T .0118(l), prior to exceeding 80 percent of the system's permitted hydraulic capacity (based on the average flow during the last calendar year), the permittee shall submit an engineering evaluation of their future wastewater treatment, utilization, and disposal needs. This evaluation shall outline plans for meeting future wastewater treatment, utilization, or disposal needs by either expansion of the existing system, elimination or reduction of extraneous flows, or water conservation and shall include the source of funding for the improvements. If expansion is not proposed or is proposed for a later date, a justification shall be made that wastewater treatment needs will be met based on past growth records and future growth projections, and as appropriate, shall include conservation plans or other measures to achieve waste flow reductions. ❑ ❑ Yes (the hydraulic capacity greater than 80%) — Proceed to the next question. ❑ ❑ No — Skip Attachment F. If answered Yes above, does the hydraulic capacity in Section III, Item 4 exceed 80%? ❑ ❑ Yes (the hydraulic capacity is greater than 80%) — Pursuant to 15A NCAC 02T .0118(2), prior to exceeding 90 percent of the system's permitted hydraulic capacity (based on the average flow during the last calendar year), the permittee shall obtain all permits needed for the expansion of the wastewater treatment, utilization, or disposal system and, if construction is needed, submit final plans and specifications for expansion, including a construction schedule. If expansion is not proposed or is proposed for a later date, a justification shall be made that wastewater treatment needs will be met based on past growth records and future growth projections, and as appropriate, shall include conservation plans or other specific measures to achieve waste flow reductions. ❑ ❑ No — Skip Attachment F. TTACHMENT G — EASEMENT, ENC4ACHMENT, AND LEASE AGREEMENTS Does the Permittee own all of the land associated with the wastewater collection, treatment, conveyance, and irrigation system? ❑ ❑ Yes — Skip Attachment G. ❑ ❑ No —Pursuant to 15A NCAC 02T .0116(c), provide a copy of all easements, lease agreements, and encroachment agreements allowing the Permittee to operate and maintain the wastewater collection, treatment, conveyance, and irrigation system on property not owned by the Permittee. H — AFFILIATIONS Are the Permittee's affiliations of record correct'? Check affiliations. ❑ ❑ Yes — Skip Attachment H. ❑ ❑ No — Provide the corrected affiliations and their contact information. ATTACHMENT I — COMPLIANCE SCHEDULES Does the existing permit include any Compliance Schedules? (See Section I of the most recently issued permit) ❑ ❑ Yes — Submit documentation that the compliance schedules have been met. ❑ ❑ No — Skip Attachment I. ATTACHMENT J — CIVIL PENALTIES AND (STANDING VIOLATIONS Does the Permittee have any existing civil penalties or outstanding violations? ❑ ❑ Yes (civil penalties) — Submit payment for the civil penalty, or proof of remission request. ❑ ❑ Yes (violations) — Submit a copy of your response to the Notice of Violation. ❑ ❑ No — Skip Attachment J. FORM: WWIS-R 02-21 Page 7 of 6 ATTACHMENT K — INDUSTRIAL WASTEWATER Does the wastewater composition in Section III, Item 5 include any industrial wastewater? ❑ ❑ Yes — Proceed to the next question. ❑ ❑ No — Skip Attachment K. Has the nature of the industrial wastewater changed since the last permit issuance (i.e., changes in industrial process, introduction of new materials or chemicals, etc.)? ❑ ❑ Yes — Provide a chemical analysis of the wastewater pursuant to the requirements in 15A NCAC 02T .0504(hl. Provide an overview of the manufacturing process; an inventory of all chemical and biological materials used in the manufacturing process; and an overview of the cleaning and treatment methodology. ❑ ❑ No — Provide an overview of the manufacturing process; an inventory of all chemical and biological materials used in the manufacturing process; and an overview of the cleaning and treatment methodology. Our manufacturing process has not changed; it consists only of water and small grains. ATTACHMENT L— SETBACK WAIVERS Does the existing permit include setback waivers? ❑ ❑ Yes — Pursuant to 15A NCAC 02T .0506(d), provide setbacks waivers that have been written, notarized, signed by all parties involved, and recorded with the county Register of Deeds. Waivers involving the compliance boundary shall be in accordance with 15A NCAC 02L .0107 . ❑ ❑ No — Skip Attachment L. APPLICANT'S CERTIFICATION I, hoso& attest that this application (Signature authority's name as noted in Section I, Item 3) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application package are not completed, and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. I further certify pursuant to 15A NCAC 02T .0120(bl, that the applicant, or any parent, subsidiary, or other affiliate of the applicant has: not been convicted of environmental crimes under; not previously abandoned a wastewater treatment facility without properly closing the facility; not paid a civil penalty; not been compliant with any compliance schedule in a permit, settlement agreement, or order; not paid an annual fee. Note: The Applicant's Certification shall be signed pursuant to 15A NCAC 02T .0106(bl. An alternate person may be delegated as the signing official if a letter is provided pursuant to 15A NCAC 02T .0106(c). Pursuant to § 143-215.6A and § 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 11-20-22 THE COMPLETED APPLICATION AND ATTACHMENTS SHALL BE SUBMITTED AS A SINGLE PDF FILE VIA: Email: Non-Discharge.Reportskncdenr. gov Laserfiche Upload: http s:Hedocs.deU.nc. goy/Forms/NonDischarge-Branch-Sub mittal-Form-Ver2 FORM: WWIS-R 02-21 Page 8 of 6 SUPPLEMENTAL SOIL AND SITE EVALUATION Carolina Malt House Cleveland, North Carolina Prepared For: Carolina Malt House 12969 Statesville Boulevard Cleveland, NC 27013 Prepared By: Thompson Environmental Consulting t�'f'�TER • 't��'1STE�'ATER • �l'F,TI,.1 � [ tti Thompnson Environmental Consulting, Inc. PO Box 541 Midland, NC 28107 July 4, 2020 Afc54A'+ ptvner INTRODUCTION Thompson Environmental Consulting (TEC) has been retained by the Carolina Malt House to perform a supplemental soil and site evaluation of their property located at 12969 Statesville Boulevard, Cleveland, NC 27013 (Rowan County Parcel Number: 265 001). The purpose of this evaluation is to confirm that the soil and site conditions have not changed since our October 1, 2015 report. SITE DESCRII'TION AND INVESTIGATION METHODOLOGY The study area is comprised of 18.73 acres of open fields and woods, and is currently used for a commercial barley malting operation and spray irrigation of the wastewater generated from the steeping process. Soil borings were advanced with a hand -auger and soil color was determined with a MunseIl Soil Color Chart. Observations of the landscape (slope, drainage patterns, etc.) as well as soil properties (depth, texture, structure, soil wetness, restrictive horizons, etc.) were recorded. Each soil boring was located in the field using a hand-held GPS unit. SOIL EVALUATION A supplemental field survey was conducted on July 4, 2020, by Larry Thompson, LSS. Five (5) soil borings were advanced at various locations throughout the property and their locations noted on Figure 1. The soil units described in our 2015 report have not changed and do not appear to be hydraulically overloaded. CONCLUSION The findings presented herein represent TEC's professional opinion based upon our site evaluation and knowledge of the current laws and regulations governing on -site wastewater systems in North Carolina (Section .1900 of the North Carolina Administrative Code —NCAC and Title 15A Subchapter 2T). Soils naturally change across a landscape and contain many inclusions. As such, attempts to quantify them are not always precise and exact. Due to this inherent variability of soils and the subjectivity when determining limiting factors, there is no guarantee that a regulating authority will agree with the findings of this report. Any concurrence with the findings of this report would be made by the appropriate permitting agency at the time permit modifications are issued. Carolina Mall House 2 July 4, 2020 Date: ThompSoil Boring Locations July 2020 Figure Enyison prepared For: ronmenta Carolina Malt House Scale: Consuifi p SO 1fi0ft Carolina Malt 12969 Statesville Boulevard 1+ House Cleveland, IVC 27013 EC Job #: Rowan County 20-85 Spray Irrigation Design Elements Drip Irrigation Design Elements Nozzle wetted diameter: 108 ft Emitter wetted area: ft2 Nozzle wetted area: 4,486 ft'- Distance between laterals: ft Nozzle capacity: 8.38 GPM Distance between emitters: ft Nozzle manufacturer/model: Senninger / 50 Series Emitter capacity: GPH Elevation of highest nozzle: 765 ft Emitter manufacturer/model: 1 Specification Section: See Irrigation Section (drawings) Elevation of highest emitter: ft Specification Section: VIII. SETBACKS — 15A NCAC 02T .0506: I. Does the project comply with all setbacks found in the river basin rules (15A NCAC 02B .0200)? ® Yes or ❑ No If no. list non -compliant setbacks: 2. Have any setback waivers been obtained in order to comply with 15A NCAC 02T .506 a and .05OfiJJb? ® Yes or ❑ No If yes, have these waivers been written, notarized and signed by all parties involved and recorded with the County Register of Deeds? ® Yes or ❑ No 3. Provide the minimum field observed distances (ft) for each setback parameter to the irrigation system and treatment/storage units (NOTE — Distances greater than 500 feet may be marked N/A): Setback Parameter Irrigation System Treatment / tnra a Unit Any habitable residence or place of assembly under separate ownership or not to be maintained as part of the project site N/A N/A Any habitable residence or place of assembly owned by the Permittee to be maintained as art of the project site N/A Any private or public water supply source 256' 190, Surface waters (streams — intermittent and perennial. perennial waterbodies, and wetlands) 100' Groundwater lowering ditches (where the bottom of the ditch intersects the SHWT) N/A Subsurface groundwater lowering drainage systems N/A Surface water diversions (ephemeral streams, waterways, ditches) 25' Any well with exception of monitoring wells 256' 205' Any property line 150' 54' Top of slope of embankments or cuts of two feet or more in vertical height 75' Any water line from a disposal system N/A Any swimming pool N/A Public right of way 50' Nitrification field NIA Any building foundation or basement 82' Impounded public water supplies N/A Public shallow groundwater supply (less than 50 feet deep) NIA 4. Does the Applicant intend on complying with 15A NCAC 02T .0506(c) in order to have reduced irrigation setbacks to property lines? ❑ Yes or ® No If yes, complete the following table by providing the required concentrations as determined in the Engineering Calculations: PC)Pk - WWrcn6,1h Page 12 of 12 ;,• `- N __� Parcel Boundary 1 StudyArea ® Ksat Locations � Soil Unit 1 (Pacolet) ��Y]f Soil unit 2 Budding slSo Basin Footpnnt ; Ksats 14115 Potential Jurisdictional 4. Feature Edge -Stream Ksais 12113 ` 100-Foot Buffer 4 A 5.78 acres 25-Foot Buffer Ksat 10 !•w-. - DO*- Gulley ® Well acres Ksat s PA Ksat 11Ks3ts 1;2 Al A. Ksats 314��` 2.1 acres �, yet• a� F Ksats 6/6 V r 'k1 T� � �F, .'4 a lam' �•- 1 _ AV •'+" fff �•• � �._ . ��, ,R•nf `fit ,} .- +L�• t?�n - F Yj Thompson Environments $% Consulting NC QneMap. NO Center for Geographic Information and Analysis NO 911 Board ' Carolina Malt House Hydraulic Conductivity Testing Map Rowan County, North Carolina Date. January 2017 scar-- 0 75 150 Feet L • 1 Job No. Figure 4 1 1 Page 10 of 27 ' # + A r j'"'• ti'1ia•: (0 OpenSt',&efMap {and) contributdrs CC -BY -SA r I J' �i LISGS The National Map National 866r7dar*s Dataset. National Elevation Dataset Geographir, Nam ,Information System, National Hydrography Dataset. National Land ver Database. Nat;Qndl Parcel Boundary 1 Structures Dataset, and National Tra(ispbrtat!nn Dataset. U S Census Bureau - TIGER/Line. HERE Road 5�tg Thompson Environments Consulting Carolina Malt House USGS Topo Map Rowan County, North Carolina Date Figure January 2017 Scale 0 750 1.500 Feet L I Page 7 or27 Thompson Environments Consulting Date Carolina Malt House January 2017 Scale USDA-NRCS Soils Map 0 1a7 5 275 Feet Figure 2 Rowan County, North Carolina Page 8 of 27 N Parcel Boundary �. ._ StudyArea Soil Borings Soil Unit 1 (Pacolet) t q ' Soil Unit 2 Unsuitable Ot Soil Unit 1 (Pacolet) sky' bi Soil Unit 2 b 13 Building Silo F'1 ' Basin Footprint " Potential Jurisdictional b2 Feature Edge A-, �.� Stream 15 78 acres 100-Foot Buffer 2 67 acres b12 25-Foot Buffer //F ►I- Gulley dcres well S. S . 1 .- b7 VIA NC QneMap• NC Center for Geographic Information and Analysis ej 513 Board Thompson Environments Consulting Carolina Malt House Delineated Soil Units Map ]ate Figure January 2017 scale 0 m, m Xee. 3 Rowan County, North Carolina Page 9 oF27 9. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is not the Permittee and owns land within the compliance boundary shall execute and file with the Rowan County Register of Deeds an easement running with the land containing the following items: a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1); b. Prohibits construction and operation of water supply wells within the compliance boundary; and c. Reserves the right of the Permittee or the State to enter the property within the compliance boundary for purposes related to the permit. The Director may terminate the easement when its purpose has been fulfilled or is no longer needed. [15A NCAC 02L .0107(f)] 10. The facilities permitted herein shall be constructed according to the following setbacks: a. The setbacks for spray irrigation sites permitted under 15A NCAC 02T .0500 shall be as follows (all distances in feet): i. Any habitable residence or place of public assembly under separate ownership: 400200 ii. Any habitable residence or place of public assembly owned by the Permittee: 100 iii. Any private or public water supply source: 100 iv. Surface waters: 100 v. Groundwater lowering ditches: vi. Surface water diversions: vii. Any well with exception of monitoring wells: 25 100 150' viii. Any property line: 15 ix. Top of slope of embankments or cuts of two feet or more in vertical height: 10 x. Any water line from a disposal system: 100 xi. Subsurface groundwater lowering drainage systems: 100 xii. Any swimming pool: 50 xiii. Public right of way: 20 xiv. Nitrification field: 15 xv. Any building foundation or basement: ' Per a setback waiver recorded in the Rowan County Register of Deeds, setbacks from the wetted area to any property line has been reduced for the following: Parcel No. Deed Book 1 Page Setback 265-001 1288 / 420 0 feet 263-009 1288 / 420 0 feet Easement 150 feet 150 feet [l5A NCAC 02T .0506(a)} its permitted under 15A NCAC 02T .0500 shall be as follows (all b. The setbacks for storage un distances in feet): i. Any habitable residence or place of public assembly under separate ownership: ii. Any private or public water supply source: iii. Surface waters: iv. Any well with exception of monitoring wells: v. Any property line: [15A NCAC 02T .0506(b)] 100 100 50 100 50 WQ0039181 Version 1.D Shell Version 151201 Page 3 of 9 �'v A b-I b2 a sir 'Af 2 67 acres b b3 3 acres A. Thompson EnvifonmentaS Consulting N Parcel Boundary StudyArea Soil Borings Oil Soil Unit 1 (Pacolet) Soil Unit 2 Unsuitable Soil Unit I (Pacolet) Soil Unit 2 Building Sslo ib ..A W N, Basin Footprint A Potential Jurisdictional ' Feature Edge Stream 5 78 acres I 00-Foot Buffer b12 25-Foot Buffer DODO- Gulley 1511 b7 it NC One Map. NC Center for Geographic Informatton and Ana', 911 Board Carolina Malt House Delineated Soil Units Map Rowan County, North Carolina =11 )ate January 2017sgle Figure Paw 9 (W27 K r Ksats 141i5 ?�- Ksats 12113 5 78 acres Ksal 10 i AYr� �•� ,�' .� V : 2 of acres Ksat 9 . a;;f'S �� Ksat 11 �'A A Ksats 112 st r Vie, ��. " Ksats 71S I 4 ` Ksats 314.�".1 acres 2 " } Ksats516+ ,.% . •^tat, �, .t {: "• �9 Thompsw Environment* Consulting Parcel Boundary StudyArea Ksat Locations Soil Unit 1 (Paoolet) Soil Unit 2 Building Silo Basin Footprint Potential Jurisdictional Feature Edge Stream 100•-Foot Buffer 25-Foot Buffer POP- Gulley E" Well �► '`err . NC OneMap, NC Center for Geographic Information and_A,"Iysis. NC 911 Board 4 Carolina Malt House Hydraulic Conductivity Testing Map Rowan County, North Carolina le: Figure January 20t 7 ale 0 75 150 F" ! No.: 4 Page 10 of 27