Loading...
HomeMy WebLinkAboutNC0032212_Authorization to Construct_19900622Mr. John E. Rice Yonahlossee Limited Partnership Post Office Box 1397 Boone, North Carolina 28607 Dear Mr. Rice: State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27611 James G. Martin, Governor George T. Everett, Ph.D. William W. Cobey, Jr., Secretary Director June 22, 1990 Subject: Permit No. NC0032212 Authorization to Construct Yonahlossee Limited Partnership Wastewater Treatment Facility • Watauga County A letter of request for an Authorization to Construct was received March 1, 1990 by the Division and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of a 20,000 GPD wastewater treatment plant consisting of a manual bar screen, a 20,000 gallon aerated flow equalization basin with two 42 gpm grinder pumps and a 45 CFM blower, a three way flow splitter box, a 20,000 gallon aeration chamber with a froth control system and two (2) 160 CFM blowers, a 4,000 gallon clarifier with a surface area of 69 square feet, a 3,000 gallon aerated sludge holding tank, a 1,750 gallon disinfection/post aeration chamber with UV disinfection, a 45 degree V-notch weir with a flow recorder and totalizer, and all the associated pipes, valves and appurtenances with discharge of treated wastewater into Lance Creek class C-trout. This Authorization to Construct is issued in accordance with Part III paragraph B of NPDES Permit No. NC0032212 issued April 17, 1989, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0032212. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the North Carolina Division of Environmental Management. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, phone no. (704) 251-6208 be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Pollution Prevention Pays P.Q. Box 27687, Raleigh, North Carolina 27611-7687 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer Mr. Rice June 22, 1990 Page Two Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to the Permits and Engineering Unit, P.O. Box 27687, Raleigh, NC 27611. The Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge of the wastewater treatment facilities. The operator must hold a certificate of the grade at least equivalent to the classification assigned to the wastewater treatment facilities by the Certification Commission. Within thirty days after the wastewater treatment facilities are 50% complete, the Permittee must submit a letter to the Certification Commission which designates the operator in responsible charge. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Environmental Management in accordance with North Carolina General Statute 143-215.6. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Mr. Mark Hawes, telephone number 919/733-5083. Sincerely, 1 eorge T. Evere cc: Watauga County Health Department Asheville Regional Office Training and Certification Unit Municipal Engineering Services Company, P.A. r