Loading...
HomeMy WebLinkAboutSW6220506_Supplement-EZ Form_20221122SUPPLEMENT-EZ COVER PAGE FORMS LOADED .PROJECT INFORMATION 1 I Project Name _ 2 Project Area ac Williford Cove 83.59 3 _ Coastal Wetland Area ac 4 Surface Water Area ac 0.58 5 Is this ra'ect High or Low Dens' ? Low 6 Does this project use an off -site SCM? No COMPLIANCE WITH 021-1.100 4j 7 Width of vegetated setbacks provided feet 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? _ NIA l 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 12 Infiltration System Bioretention Cell 13 Wet Pond 14 _ Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader -Filter Strip LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 _Rayftiter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Organization: Street address: City, State, Zip: Phone number(s)7 Email: Jeffrey A. Nobles, PE 28 _ _ _ Larry King & Assoc. RLS, PA ^� 29 1333 Morganton Road, Suite 200 30 Fayetteville, NC 28305 31 910-483-4300 32 _ innhlaa6illknnda r•.nm Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. ,0111 1Oirrll►1 _ SEAL 31459 %` 44-1 V Signattvto q- ICI-2z DRAINAGE AREAS 1 Is this a high density rgject? No 2 If so, number of drainage areas/SCMs 0 3 Does this pLoject have low density areas? Yes 4 If so, number of low dens drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION EnUrs Site LD 1 4 Type of SCM nla nla 5 Total drainage area (sq ft 3641180 3641180 6 Onsite drainage area (sq ft 7 Offsite drainage area (sq ft 8 Total BUA in project ft 371310 sf 371310 sf 9 New BUA on subdivided lots (subject to permitting) (sq ft 220000 sf 2200DD sf 10permitting) New BUA not on subdivided lots (subject to s 151310 sf 151310 sf 11 Offsite BUA (sq ft 12 Breakdown of new BUA not on subdivided lots: Parkin (sq ft sf sf &dewalk (sq ft sf sf Roof (sq ft sf sf - Roadway s ft 151310 sf 151310 sf Future sq ft sf sf Other, please specify in the comment box below (scl.ft sf sf sf sf 13 New infiltrating permeable pavement on subdivided lots (sq ft 14 New infiltrating permeable pavement not on subdivided lots (sq ft sf _ sf 15permitting) Existing BUA that will remain (not subject to s ft sf sf 16 Existing BUA that is already permitted ft sf sf T 17 1 Existing BUA that will be removed (sq ft sf sf 18 Percent BUA 10% 10% 19 Design storm inches 0 in .0 in 20 Design volume of SCM cu ft cf cf 21 Calculation method for design volume cf 0 ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drains a area(s): LOW DENSITY DESIG REQUIREMENTS OR LOW DENSrrY PR FROM 021-1.211311113 1 Is project below density thresholds set forth in the applicable stormwater rule? Does project maximize dispersed flow and minimize channelization of flow? Has the use of pipirg been mininvzed per.1003(2)(c)? Yes 2 Yes 3 Yes 4 _ _ Side slopes of the vegetated conveyances (H:V) Maximum velocity in the vegetated conveyances during the 1 D-year storm? sf 5 2.21 No 6 Are curb outlet swales proposed? 7 Maximum longitudinal slope of curb outlet swale(s) ("/u) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s} ) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes Yes 13 _ 14 Have stormwater outlets been designed to prevent downsl_ope erosion? Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: LINE 4: All side slopes are 3:1 or flatter. Swale # Drainage 1*0 Area BOA (ac) Pervkm area C Q (cfs) Slope N V„r,, (fps) V,d„r Flow depth (fin) (ft) 1 0.86 0.44 0.56 0.61 4.14 0.50 5.00 1.65 0.85 2 0.89 0.56 0.44 0.67 4.77 0.50 5.00 1.70 0.89 3 1.95 1.00 0.95 0.61 9.39 0.08 5.00 0.99 1.48 4 0.31 0.15 0.16 0.60 1.44 0.50 5.00 1.27 0.57 5 0.27 0.14 0.13 0.62 1.32 0.50 5.00 1.24 0.55 6 0.32 0.21 0.11 0.69 1.74 0.50 5.00 1.33 0.61 7 1.71 0.90 0.81 0.62 8.34 0.50 5.00 1.96 1.10 8 0.44 0.23 0.21 0.61 2.12 0.50 5.00 1.39 0.66 9 0.88 0.52 0.36 0.65 4.57 0.50 5.00 1.69 0.88 10 0.53 0.28 0.25 0.62 2.60 0.50 5.00 1.47 0.71 11 3.70 1.93 1.77 0.61 17.97 0.10 5.00 1.26 1.88 12 3.92 2.05 1.87 0.61 19.04 0.10 2.00 1.28 1.93 13 0.63 0.34 0.29 0.62 3.10 0.50 5.00 1.53 0.76 14 0.77 0.45 0.32 0.65 3.96 0.60 5.00 1.63 0.83 15 1.48 0.79 0.69 0.62 7.25 0.10 5.00 1.01 1.34 16 1.65 0.83 0.82 0.60 7.87 0.50 1 5.00 1.93 1.08 17 0.93 0.51 0.42 0.63 4.64 0.50 5.00 1.69 0.88 18 0.53 0.35 0.18 0.69 2.91 0.50 5.00 1.51 0.74 19 0.48 0.23 0.25 0.59 2.22 0.50 5.00 1.41 0.67 20 2.70 1.48 1.22 0.63 13.45 0.50 5.00 2.21 1.32 21 4.50 2.31 2.19 0.61 21.68 0.10 2.00 1.33 1.90 22 23 24 25 26 27 28 29 30