HomeMy WebLinkAboutSW6220902_Plansheet - Other_20221102 (9)240
235
230
225
220
215
210
205
200
31 +36.73
1 TOP: 200.34
41 INV: 11\4
2+45.04 4+05.04 4+25.04 5+65.04 5+85.04 � 0+85.04 1+05.04 2+65.04 GROVE WALK ROAD \ TOP: 224.88 TOP: 224.27 TOP: 215.86 TOP: 214.33
0+10.0 TOP: 227.36 TOP: 227.24 TOP: 226.40 TOP: 226.28 7+13.86 INV: 221.40 INV: 221.28 50' R/W (PRIVATE) INV: 219.88 INV: 218.48 INV: 210.90 INV: 209.29 _ _ _ T 31 15.740
2" BO INV: 222.00 INV: 221.93 _ OP: 204.85 TOP+200. 6
- 0+15.0, _ - - _ _ 8"X6" TEE,1+39.6. - _ _ - - - - - - - - - - - - - T - - - - - - CI 33 BEND: 198.68 INV: 199..8 NV: 195.06.
80 P 0 G 8" GV W8 8 1+29.6 8" GV W8 W8 W8 W8 gM /
W8 W8 W8 W8
TGV 0+00 IV 15 1+0017.0 4+00 MH 145+00 6+00 SS iss
3+00 S - SS S� - - 7+00 MH 13
(A2+00
o
CI 34 8,y�
SS ICI 26 /
6+45.05 _
3+07.58 4+67.57 4+87.57 - TOP: 209.89 - 8+28.9 �C9 /
3+27.58 TOP: 222.39 TOP: 221.30 - - - - - NV: 204.89 8
- - - - - - - - - - TOP: 225.s6 TOP: 22.84 - INV: 217.39 NV: 216.30 - -10' UTILITY 8" GV
INV: 220.96 -INV: 220.84 i / EASEMENT PO 35 / ° 30+29.4
/ /
/moo CI 27 S 30 8" 3V
(r-\-F
81, GV
25 / �� / 7+92.01 30+09.3
/ 26 ` TOP: 8" GV
O w 27 / I / INV: 195.74 95.74 MH 6 / A/
O < I a) 30)�oX
/ 8X- 30+11.23
TOP: 198.54
N / / �j / I / / l INV: 193.54 /
_ a O ( / / O / / Q� r01.23 /
-� - o 1
CI 28 �Q� �� ,J V: 193.42
I I 0) , / /i ,// it 2
��NS ✓O
�J
:sob
("OZ) C9 G" a,tl0 IN GROVE WALK GROVE WALK
__._... X, ___.__..___,/ __._... ___.__..--- ,/
ROADWAY PROFILE -0+50 TO 5+50 ROADWAY PROFILE 5+50 TO 9+00
HIGH POINT ELEV = 225.78
HIGH POINT STA = 3+50.71
PVI STA = 4+43.56
PVI ELEV = 225.22
A.D. = -7.09%
K = 26.18
186' VC
0
O
C
O+
N
II
N
II
w
rn
r-�
o 06 ,4:
W
OMNO
a-
N
ONj
^r�
r�6NOZ
_
:20Of
n
O N U-) O
O NUf N�
1 0-N F N
-
O N
0 N Z O Z
- -
_
2 + �» Q
WATER
MIN COVER 36"
8" C900
\
O
00
N
0+85.0
0221.27
5.0
0221005
\
O
O
+
O
�220.06�2+65.0
219.90
\
J
O
0 4+05.0
\
\
>
00 U O L0
218.44
0 4+25.0
\
+
000
340.00 LF ®1.059'
217.74
\
Uj L N
8" SDR 26 PVC
\
O M
\
2882
8
�F
®S
Ogg
8 ,
SCR
26
A
�c
0 SEWER LATERAL
CROSSING WATER
0 SEWER LATER
AL CROSSING STORM
- - -
- - EXISTING GRADE
FINISHED GRADE
I
C0
00
Cb r7
00
L
00
N O
00
0)rr)
00
(0M
00 tb
00
0
00 O
N
O
O
M M
N
(0N
r^
r^
^ r
r
r
O
6^
Ln
6
M
O
c0
N
N N
N
N N
N
N N
N
N N
N
N N
N
N N
N
N N
N
N N
N
N N
N
N N
N
N N
N
0+00
1 +00
2+00
3+00
4+00
5+00
240
225
225
J
N
O) O
ui
rn �
O
^ON
CO
235
220
^,�0
220
��
+ >
Q N �?
LOW POINT ELEV = 203.21
1
LOW POINT STA = 7+43.73
PVI STA = 7+03.33
ro a
PVI ELEV = 205.23
(0 c')"
- A.D. = 2.69%
Cd uK = 30.00
\
�
0
81' VC
230
215
\
0,6
co ��
215
\+0ZO
ro 0) U> >
\ ' b'g9
U 04 Z
n
N
\
\
(0
J Fj
O
225
210
5+65.0
0210.12
\
J M
O
210
\ \ c
� N
05+85.0
00q
o0)=rn
(0
00
208.64
. 4 , -
M11) OZ
+
\
GO�Z
26.00 LF ® 0.96%
1 RCP
\ \ ^ �z z F-
ao
\ I
\
N
�,
27.55 LF ® 3.45% 15" RC
\
J F
_
1Z 1 _
220
205
\
Fv
M O
d1
O
Ln
-
LL J
205
3.3
PO 35
205.50 (CI
34)
NCO
+
0000
+�
0)INV
o N^N
07 coco
^NO
S
oZo
00
II
0)
II
N0t00�
600 Orn
00N-
>riN+
-F-
00
Z Z>>
\
U
N
H
>/LLJ
-1
O
+ » >
\ \
>U
jw
-
WATER MIN
COVER 36"
-s OC
\
a
o\
215
200
200
8 •
g�0
0 7+13.9
00%
198.68
\
26.00 LF ®1.15% 15P
\
7g0
4
<F®g
\
210
195
g8g8„ 2.38'
SpR
I
195
I
\
2g
A
VC
62.21 LF ® 3.68%
15" RCP
205
190
Ld 0)
190
+-U °
00 00 - +
Ip 00
0 SEWER LATERAL
CROSSING WATER
0 SEWER LATERAL
CROSSING STORM
- - -
- - EXISTING GRADE
FINISHED GRADE
200
185
185
O
N
O
rh
r m
1�
N M
l�
N
l� N rh
N N
cO Oi
N O
QO A p N
N O N O
O
N O
d 00
0)
N
N
6+00
7+00
8+00
9+00
GRAPHIC SCALE
40
0
20
40
80
( IN FEET )
1 inch = 40 ft.
160
4Dsite
solutions
civil engineering I land surveying
409 Chicago Drive, Suite 112, Fayetteville, NC 28306
office 1910-426-6777 fax 1910-426-5777 license number I C-2354
wwwAD site solutions.com
CARO,���''
SEA
02
N
G ••E ••: ja���
••.....••
�O
REVISIONS
PROJECT NAME
WOOD LAKE II
PHASE II
SUBDIVISION
GROVE WALK
PROFILE
CLIENT
RAEFORD
DEVELOPMENT
COMPANY, LLC
645 Laurinburg Highway
Raeford, North Carolina 28376
Phone: (910) 638-6102
PROJECT INFORMATION
DESIGNED BY:
CHRIS
DRAWN BY:
BRETT
CHECKED BY:
SCOTT
PROJECT NUMBER:
1632
DRAWING SCALE
HORIZONTAL: 1 "=40'
VERTICAL: 1 "=4'
DATE RELEASED
APRIL 5, 2022
SHEET NUMBER
C-5n3