Loading...
HomeMy WebLinkAboutWQ0042584_Application (FTSE)_20220927DocuSign Envelope ID- BFB11714-EE35-4385-87A4-COC6B9AC814A NC Dept of Environmental Quality State of North Carolina DWR Department of Environmental Quality SEP 17 2022 Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlslon of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION alei h Regional Office Application Number: (to be completed by DWR) M All Items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: Chatham Park Investors LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ StatelCounly ❑ Municipal ® Other 3. Signature authority's name: Timothy_R. Smith (by: Robin R. Rose. Registered Agent) per 15A NCAQ 021' .QI06 Title: Vice President 4. Applicant's mailing address: 105 Weston_lstatcs Wax City: CCr r State: NC Zip: 27513 5. Applicant's contact information: Phone number: (9 [ 9)1811-3000 Ext. 5 Email Address: Robin(Qprestondev.com If. PROJECT INFORMATION:C I. Project name; QLasham Park Surt:un 5.1 Subdivision_North Phase 5 & 6A 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0042584 and issued date: June For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00� 3. County where project is located: Chatham County 4. Approximate Coordinates (Decimal Degrees): latitude: g.731, Longitude:-79.151' 5. Parcel ID (if applicable): 7250 & 86970 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Nicholas J. Anlrilli, PE License Number: 38549 Firm: WithersRavcnel Inc. Mailing address: 115 MacKenan Drive City: _Cary State: NC "Lip; 2755111 Phone number: (919) 238-0362 Email Address; nantrilfi withcrsravcn0.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Chatham Park Water Recovery Center Permit Number: W 0039375 Owner Name: Chatham Park Investors LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION: I. Permit Number(s): WQ9041455 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity 0 Force Main 3. System Wide Collection System Permit Number(s, (if applicable): WQCS00146 Owner Name(s): Town of Pittsboro FORM: FTA 06-21 Pagel of 5 DocuSign Envelope ID: SF811714-EE35-4385-87A4-COC6B9AC614A Vi. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached'? [:]Yes ❑ No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Dtrvt 4)W's (hw. ;15jQn4l Alreempr�t }I M D *V!been attached? NOl F;! 'fhc Developer intends to transfer ownership of the sewer lines dirLCIIV to the Town of Pitasboro, upon Construction and Certification, via the submiltal of n PNOCF Change of Ownrrshlp farm. ® Yes ❑ No ❑ NIA 3. If the Applicant is a Home/Property Owners' Association, has an I:IOA?POA Operational �i&WpV,�t (FOIZM: IInAJ and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ®NIA 4. Origin of wastewater: (check all that apply): ® Residential (individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/scrvice ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic % Commercial . % Industrial (S A� &I AC_tWT_01011 If Industrial, is there a Pretreatment Program in effect? ❑ Yes[] No 6. Has a flow reduction been approved under I SA NCAC 02'1' .0 1 ? ® Yes ❑ No ➢ If Yes, provide acopy. of Row reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow 1-6 No. of Units Flow Single Family Residential Housing 180 gal/day (60 gpd x 3 BR/unit) 121 21,780 GPD gal/ GPD gall GPD gal/ GPD gal/ GPD gall GAD Total 21,780 GPD a Sec 15A NCAC 02'I' .01.14(b), (d),101) urr,d (tc1(2] for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas, and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A1 NC&C 02T.D 114] shall be determined using available Flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project; 21.780 GPD (per I SA NCAt' b " .010 ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station. -Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow, ❑ Flow has already been allocated In Permit Number: _ _ Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain); FORM: FfA 06-21 Page 2 of 5 DocuSign Envelope ID: BF811714-EE35-4385-87A4-COC689AC814A VII. GRAVITY SEWER DFSIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 3,694 PVC 13" 163 DIP 5-7 D Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (If Applicable) — 01'1'.0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OFTHIS PAGE FOR LACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) D This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01CA.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with I M N'CAG -2T .0305(ltlf i I: ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day D Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: D Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. D If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of DocuSign Envelope ID: 8FB11714-EE35-43B5-87A4-COC6B9AC814A IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 027- .0305(f)): 1. Does the project comply with all separations(altemalivcs found in ILA,J4�.A;' 02T ,03051t1 ( ? ❑Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be pros _ Setback Parameter+ Storm sewers and other utilities not listed below (vertical) ZWatcr mains (vertical - water over sewer preferred, including in benched trenches) 2Walcr mains (horizontal) Reclaimed water lines (vertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed over sewer) for sewer systems: Separation Required 18inches 18inches 10 feet 18 inches 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet *'"Waters classified WS (except WS-1 or WS-V), 8, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (sec item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains _ 5 feet Any swimming pools 10 feet Final earth grade (vertical) T 36 inches+ ➢ If noncompliance with 02T.0305[t) or (gj, see Section X.1 of this application contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. "Stream classifications can be identified using the Division's NCSurfarx Watcr'lussiticut�uns wcwc 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ MA ➢ If no, please refer to 15A NCAC 18C.0906(o for documentation requirements and submit a separate document, signed/scaled by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ® N;'A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ Sec the Division's dmiLsVArMion MgUiNpic for situations where separation cannot be met ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Haw River ❑ No If yes, does the project comply with setbacks found in the river basin rules per ! JA NCAC 0211 MOW ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 213.OM 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit numberlpermitting status in the cover letter if coverage/authorization is required. 6. Does project comply with ,J�ANCAC Q2T,01UMo;1(b) (additional permits/certifications)? ® Yes ❑ No Per i5A. NCAC 02T.010 cX0), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 1.5A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six-montbs and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit, FORM: I -TA 06-21 Page 4 of 5 DocuSign Envelope ID. BF811714-EE35-43B5-87A4-COC6B9AC814A X. CERTIFICATIONS: I_ Does the submitted system comply with 15A NCAC 02T, the Minimum Dcsigg_Crileria lortlle Permitting of Pump Stations and f orce Maitts{latest version,, and theCtravit!e Sewer Minimum Desiglt L'ritcria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Allcmative Design Request application (VADC 10-I4) and supporting documents for review to the Central Office. Approval of the request will be Issued concurrently with the approval of the permit, and projects requirine a variance approval may be subiect to loneer review times. For Prolects muiring two or more variances or where the variance is determined by the Division to be a significant portion of the proiect, the full technical review is required. 2. Professional Engineer's Certification: 1, —Nicholas J,#nttilli, PE attest that this application for Chatham Park Section 5.1 Subdivision North Phase 516A (Professional Engineer's name from Application Item I ll.1.1 (Project Name from Application item 11.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, ilanittt t tt Dcsi n [�iieria titr(inavi Stew t� l:ltc • . ion , and the Mini�ttum I] •yi Critcxia for the I a.t=i:r lck_Pcrmitli� g yr Ptuop Station,;gti�,LJFtrc . ins {lalkst version}. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a line not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (2 t NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 0N FARO ° 6000. a /if. a°°GeCS S 0000 °' Y, Off° u c e!1 Q� �` e JJ SEALo a ° 38549 e e ° 2e e I��DocuSignid b�%°°%, °° VOKSF�SVIt9M02Sdt3V 0�/V4 tiV :I ea° o°eo° mS:'�u�a Q?°O v so4Ik3/2022 TE498' QOs 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Tim Smith by: Robin Rose Re islered Agent attest that this application for Chatham Park Sec.5.1 Sub. North Phase 5/6A (Signature Authority Name from Application Item 1.3.) (Project Name from Application Item IL1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.1!A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000 as well as civil penalties up to $25,000 per violation. Signature: _— ,C ,tit' Data: t_ FORM: 1TA 06-21 Page 5 of 5 NC Dept of Environmental Quality State of North Carolina Department of Environmental Quality Division of Water Resources SEP Z 7 2022 Raleigh RegiorMking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Chatham Park Investors LLC Project Name for which flow is being requested: Chatham Pk Sec 5.1 North Ph 5&6A More than one FTSE maybe required for a single pro Ject ifthe owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater jlow 1. Complete this section only if you are the owner of the wastewater treatment plant. a. b. C. d. e. WWTP Facility Name: Chatham Park Water Recovery Center WWTP Facility Permit #: To be provided Al! flows are in MGD WWTP facility s permitted flow Estimated obligated flow not yet tributary to the WWTP WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h P 0.5 0.0106 0.0 0.0218 0.0324 . ercent of permitted flow used 6.48% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) {IB) Design Pump pump Average Approx. Station Station Firm Daily Flow** Current (Name or Permit Capacity. • (Firm / pf), Avg. Daily Number) No. MGD MGD Flow, MGD N/A (C) (D)=(BBC) (E)~(A-D) Obligated, Not Yet Total Current Tributary Flow Pius Daily Flow, Obligated Available MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station sin defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pQ not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: Page 1 of 6 FTSE 10-19 III. Certification Statement: I _Timothy R. Smith certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendums for which i am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. A-m ;-/ it .i�gninff okiul Sigflhrrr -- Title of Signing Official Page 2 of 6 2 2 Z,0Z / Date FTSC !0-18 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section 1I where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for N/A % and MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. 1 understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 3 of 6 FISp 10-1R N N 2 41 N !D L L J C S4 l0 Q Q � L O N C V c li Z U J U I I C M IL I E ,w 0 d 0 a. RW �Q �H U� SMS bl 7 O L� �U U o •p E _T C M M Jm ti U a Ch GS ul M V3 cow Z 0 E; I § ?} 3 U� qd «� h )a CL .3i U � k m m — ( k W LL 7 6 d U ■ , 19 Ev o o J 4 E e m g—�� �2Ea e _ e Z wwzo ROY COOPER Governor MICHAEL S. PECAN Secretary LINDA CULPEPPER Director Chatham Park Investors, LLC c/o Tim Smith 100 Weston Estates Way Cary, NC 27513 NORTH CAROUNA Environmental Quality January 14, 2019 Subject: Adjusted Daily Sewage Flow Rate Approval Chatham Park Development Chatham County Dear Mr. Smith: NCDepr Of Environmental Qijhllt. Raleigh Regional of+y7ee On July 16, 2018, the Division of Water Resources (Division) received an adjusted daily sewage flow rate (flow reduction) request that would apply to all permitted but not yet tributary residential connections and all future residential connections within the Chatham Park Development service area. In accordance with 15A NCAC 02T .0114(f)(2), the Division has evaluated the request as well as additional information received on October 15, 2018, and based on the data submitted and the Division of Water and Infrastructure (DWI) guidance, the Division hereby approves for use by the Chatham Park development an adjusted daily sewage design flow rate with the following conditions: • The flow reduction is applicable to residential single family dwellings only. • The minimum flow for 1 and 2 bedroom dwellings shall be 120 gallons per day. • Each additional bedroom above two bedrooms shall increase the volume by 60 gallons per day per bedroom. • This flow reduction shall not apply to sewer extension applications and/or permits for any other public or private organizations whose wastewater flows are or might become tributary to Chatham Park collection system. Future sewer extension applications should be made using the flow reduction amount stated above. All other aspects of the permitting process remain unchanged, and all applications must be in compliance with the statues, rules, regulations and minimum design criteria as certified by the owner and engineer. Regardless of the adiusted design daily -wastewater flow rate at no time shall the wastewater flows exceed the effluent limits defined in the NPDES Permit for the treatment facility or exceed the capacity of the sewers downstream of any new sewer extension or service connections . +�,, North Carolina Department of Envfronmental Quality Division of Water Resources D E ✓� 512 North Salisbury Street 1 1617 Mall Service Center Raleigh, North Carolina 7.7699. w7 �+����-Jro�'00 919,707.9000 The granting of this flow reduction does not prohibit the Division from reopening, revoking, reissuing and/or modifying the flow reduction as allowed by the laws, rules, and regulations contained in 15A NCAC 02T, NCGS 143-215.1, or as needed to address changes In State and/or Federal regulations with respect to wastewater collection systems, protection of surface waters and/or wastewater treatment. If you have any questions, please contact Christyn Fertenbaugh, P.E., at (919) 707-3625, or via email at Christyn.Fertenbaugh ncdenr.gov_ Sincerely, for Linda Culpepper Director, Division of Water Resources by Deborah Gore, Supervisor Pretreatment, Emergency Response and Collection Systems Branch Cc_ Nisha Thuruthy, McKim & Creed (MThuruthy mckimcreed.com) Mike Meyers, Old North State Water Company (mmeversenvirolinkinc,com) Raleigh Regional Office, Water Quality Regional Operations PERCS (electronic copy) ■■ ■■ WithersRavene! Our People. Your Success. September 26, 2022 Department of Environmental Quality Division of Water Resources Attn: Jason Robinson 3800 Barrett Drive Raleigh, NC 27609 NC Dept of Environmental Qualit> SEP 2 7 2022 Raleigh Regional Office RE: Chatham Park - Chatham Park Section 5.1 Subdivision North Phase 5/6A Sewer System Certification - WQ0042584 Dear Mr, Robinson, On behalf of the Chatham Park Investors LLC, please find the enclosed documentation in support of a Sewer Permit Modification and revised Fast Track Application (FTA 06-21) for the referenced project. As noted in the application and on the Record Drawings, this project will consist of 3,694 LF of 8" PVC sewer lines and 163 LF of 8" DIP sewer lines for a total of 3,857 LF of gravity sewer,. This project is located north of Thompson Street and Fire Tower Road and will connect to sewer permitted and being constructed under separate cover, (WQ0041455). The sewer proposed within this application will serve Phase 1 of Subdivision West containing 57 single family homes within this development. The proposed project will meet all of DWR's minimum design criteria for sanitary sewer extensions. The design flow rate for this project is calculated at 21,780 gpd based on NCAC 2T Rules for wastewater flow rates and the DEQ approved sewer flow reduction of 60 gal/bedroom approved under separate cover for Chatham Park and included with this submittal package. The proposed sanitary sewer line sizes are more than adequate to convey the design flow rates. Please find attached the following information in support of the application: • Record Drawings, Cover sheet revised to accurately reflect 3,8571F of gravitysewer • Fast Track Sewer System Extension Application (FTA06-21), revised to show 3,6941E of PVC sewer lines and 163 LF of DIP sewer lines, per Record Drawings • Intent to Serve, signed by the 'town of Pittsboro • DEQ Sewer Permit #WQ0041721 MOD • Chatham Park Flow Rate ReductionApprova' • USGS and Street Level Maps • Engi neering- Perm ittee Certification • Certification Checklist • Flow Tracking/Acceptance Form for Sewer Extension Applications (FTSE04-16) • Check for $480.00 made payable to NC DENR - DEQ - DWR for Modification Fee If you have any questions regarding this request or if you require any additional information, please feel free to contact me at 919-238-0312 or gavantRwithemravenel.com . Sincerely, WithersRavenel Gareth C. Avant, PE Senior Project Manager