Loading...
HomeMy WebLinkAboutWQ0002520_Compliance Report_20221123ROY COOPER covr nor ELIZABETH S. BISER seeretury RICHARp E ROGERS,JR: Director M E Carson Town of Bath PO Drawer 6a Bath, NC 27808 NORTH CAROLINA Envtronmentai Quin November 23, 2022 SUBJECT: Compliance Inspection Report Town of Bath WWTP Non -discharge Permit No. WQ0002520 Beaufort County Dear Mr. Carson: The North Carolina Division of Water Resources conducted an inspection of the Town of Bath WWTP on 11/16/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0002520. The flndings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Paul Nyarko with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at paul.nyarkoancdenr.gov. ATTACHMENTS Cc: Laserfiche Sincerely, Paul Nyarko, Environmental Specialist Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ North Carobs 4.parb,.at of Environmental QuOlti I Molar, of wathr Qnouv. Wistdacann Regions!. one 1943 HYd,h, ton square 1(d I WastrIngtio. North Carom. A669 252946.4461 4�, Permit: WQ0002520 SOC: County: Beaufort Region: Washington Compliance Inspection Report Effective: 04/19/22 Effective: Contact Person: M E Carson Expiration: 11 /30/28 Expiration: Title: Owner : Town of Bath Facility: Town of Bath WWTP Possum Hill Rd Bath NC 27808 Phone: 252-923-0212 Directions to Facility: NC Highway 92 to Bath. Tum north onto SR 1741. Tum east onto SR 1743. Facility is located on left lagoon Is unmistakable. System Classifications: WW3, SI, Primary ORC: Garland Samuel Grant Certification: 1007284 Phone: 252-923-0917 Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 11/16/2022 Entry Time 09:OOAM Primary Inspector. Paul Nyarko Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Wastewater Irrigation Facility Status: Compliant El Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Water Use Records Treatment Filters Treatment Activated Sludge Treatment Influent Pump Station Treatment Flow Measurement Standby Power (See attachment summary) • • • • Exit Time: 10:30AM Phone: 252-948-3845 Inspection Type: Compliance Evaluation Treatment Flow Measurement -influent Treatment Record Keeping Treatment Sludge Storage/Treatment Treatment Clarifiers Treatment Retum pumps Wells ▪ Miscellaneous Questions ▪ Treatment Barscreen ▪ Treatment Lagoons ▪ End Use -Irrigation 0 Treatment Disinfection ▪ Storage Page 1 of 7 permit: WQ0002520 Owner - Fadllty:Town of Bath Inspection Date: 11/16J2022 Inspection Type : Compliance Evaluation Reason for Watt: Routine Inspection Summary: A rountine inspection for permit number WQ0002520 was done on 11/16/2022 at 9:00am with the ORC Garland Samuel Grant by Paul Nyarko of Division of Water Resources Regional Office Washington.The facility was found to be In complaince with the permit. The facility has an issue with the digester which is currently beinf fixed in the process. in addition, had a violation with total suspended solids and have been fixed. the facility is accessible and safe to visit with well maintained irrigation field and carefuly mowed. June NDMR was spot checked with corresponding laboratory report and all records were present as requested by permit. Page 2 of 7 permit: W00002520 Owner - Facility: Town of Bath Inspection Date: 11/16/2022 Inspection Type : Compliance Evahiatlon Reason for Visit Routine Reuse (Quality) Infiltration System Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Drip, LR Activated Sludge Spray, HR Recycle/Reuse Single Family Drip Lagoon Spray, LR Treatment Are Treatment facilities consistent wtth those outlined In the current permit? Do all treatment units appear to be operational? (If no, note below.) Comment: Treatment Influent Pump Station Is the pump station free of bypAAR lines or structures? Is the general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are floats/controls operable? Are audlo and visual alarms avallable? Are audio and visual alarms operational? # Are SCADA/Telemetry alarms required? Are SCADA/Telemetry available? Are SCADA/Telemetry operational? Comment. new system of SCADA/ UPGRADE coming soon Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Yes No NA NE s❑❑❑ O ❑❑❑ Yee l{o NA NE ® ❑❑❑ ® ❑❑❑ s❑❑❑ ® ❑❑❑ • ❑❑❑ ■ ❑❑❑ ® ❑ ❑ ❑ ■ ❑❑❑ ® ❑❑❑ • 000 Yes No NA NE ® ❑❑❑ 1❑❑❑ • ❑❑❑ i❑❑❑ • 000 Yes No NA NE Page 3 of 7 permit WQ0002520 Owner- Faclllty: Town of Bath Inspection Date: 11/16/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is water use metered? Are the daily average values properly calculated? Comment: • ❑ ❑ ❑ ▪ ❑❑❑ Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? •❑ ❑ ❑ Is flowmeter operating properly? MOOD Does flowmeter monitor continuously? MOOD Does flowmeter record flow? MODE] Does flowmeter appear to monitor accurately? MOOD Comment: Standby Power Yes No NA NE Is automatically activated standby power available? MOOD Is generator tested weekly by Interrupting primary power source? ❑ ❑ ❑ 1 Is generator operable? MOOD Does generator have adequate fuel? 1 ❑ ❑ ❑ Comment: Treatment Barscreen Yes No NA NE Is It free of excessive debris? 1 ❑ ❑ ❑ Is disposal of screenings in compliance? MOOD Are the bars spaced property? MOOD Is the unit in good condition? MOOD Comment: Treatment Activated Sludge Yes No NA Ng Is the aeration mechanism operable? ■ ❑ ❑ ❑ Is the aeration basin thoroughly mixed? MOOD Is the aeration equipment easily accessed? 1 ❑ ❑ ❑ Is Dissolved Oxygen adequate? M ❑ ❑ ❑ Are Settleometer results acceptable? MOOD Is activated sludge an acceptable color? 1 ❑ ❑ ❑ Comment: digester having some issues and continuous operation of fixing it Treatment Clarifiers yes No NA NE, Are the weirs level? MOOD Are the weirs free of solids and algae? • ❑ ❑ ❑ Is the scum removal system operational? 11000 Is the scum removal system accessible? 11000 Page 4 of 7 permit: WQ0002520 Owner - Facility: Town of Bath Inspection Date: 11/16/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the sludge blanket at an acceptable level? Is the effluent from the clarifier free of excessive solids? Comment: Treatment Return pumps Are they In place? Are they operational? Comment: Treatment Filters Is the filter media present? Is the filter media the correct size and type? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids? Is the mud well free of excessive solids and fllter media? Does backwashing frequency appear adequate? Comment: Treatment Sludge StoragelTreatment Is the aeration operational? Is the aeration pattern even? If required, are Sanitary "Ts" present In tankage? Comment: Treatment Disinfection Is the system working? Do the fecal collform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan In the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, Is the UV Intensity adequate? # Is ft a dual feed system? ® ❑ ❑ ❑ ® ❑ ❑ ❑ Yes No NA NE ■❑❑❑ ®❑❑❑ Yes No NA NE • ❑ ❑ ❑ ® ❑❑❑ ■❑❑❑ ® ❑ ❑ ❑ ■ ❑❑❑ 1❑❑❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ 11000 ❑ ❑❑M Yes No NA NE • ❑ ❑ ❑ • El El • ❑ ❑ ❑ ■ ❑❑❑ ❑ ❑❑■ ❑ ❑ ❑• ❑ ❑❑■ ❑ ❑ ❑• ❑ ❑❑• ❑ ❑❑• ■ ❑❑❑ 1 ❑ ❑ ❑ ❑ ❑❑• Page 5 of 7 permit WQ0002520 Owner - Facility: Town of Bath Inspection Date: 11/16/2022 Inspection Type : Compliance Evaluation Reason for Vlsik Routine Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what Is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: bulb are changed consistently ❑❑❑■ ❑❑❑■ Record Keeping Yes No NA NE Is a copy of current permit available? MOOD Are monitoring reports present: NDMR? 11000 NDAR? MOOD Are flow rates less than of permitted flow? S ❑ ❑ ❑ Are flow rates Tess than of permitted flow? MOOD Are application rates adhered to? • ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? U ❑ ❑ ❑ Are all samples analyzed for all required parameters? 11000 Are there any 2L GW quality violations? • ❑ ❑ ❑ Is GW-59A certification form completed for facility? MOOD Is effluent sampled for same parameters as GW? • ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ S ❑ ❑ Are annual soil reports available? DOOM # Are PAN records required? ❑ ❑ ❑ ■ # Dld last soil report Indicate a need for lime? ❑ ❑ ❑ l If so, has It been applied? ❑ ❑ ❑ • Are operational logs present? 11❑ ❑ ❑ Are lab sheets available for review? 11000 Do lab sheets support data reported on NDMR? • ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? MOOD Are Operational and Maintenance records present? 1 ❑ ❑ ❑ Were Operational and Maintenance records complete? 1 ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? MOOD Is a copy of the SOC readily available? 11❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ 1 ❑ ❑ Comment: no treatment bypass End Use -Irrigation Yea No NA NE Are buffers adequate? MOOD Is the cover crop type specified in permit? ❑ 1 ❑ ❑ Is the crop cover acceptable? 0 ❑ ❑ ❑ Page 6 of 7 Permit: WQ0002520 Owner - Faclllty:Town of Bath Inspection pate: 11/16/2022 Inspection Type : Compllance Evaluation Reason for Visit Routine Is the site condition adequate? Is the site free of runoff / ponding? Is the acreage specified In the permit being utilized? Is the application equipment present? Is the application equipment operational? Is the disposal field free of limiting slopes? Is access restricted and/or signs posted during active site use? Are any supply wells within the CB? Are any supply wells within 250' of the CB? How close Is the closest water supply well? Is municipal water available in the area? # Info only: Does the permit call for monitoring wells? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened Interval? Are monitoring wells damaged? Comment: Cover Crop is not specified in the permit ® ❑ ❑ ❑ ® ❑❑❑ ■ ❑❑❑ ® ❑ ❑❑ ®❑❑❑ ® ❑❑❑ ® ❑❑❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑❑■ ❑ ❑ ❑• ■ ❑❑❑ ■ ❑❑❑ ® ❑❑❑ ❑ ®❑❑ Page 7 of 7