Loading...
HomeMy WebLinkAboutSW8981209_APPROVED PLANS_19990223STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 C1812 0 q DOC TYPE ❑ CURRENT PERMIT IX APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE tggq O 223 YYYYMMDD FH RADIUS ENTRY 10' LANDSCAPING BUFFER —LOT 22, SECTION 8— LANDMARK INDUSTRIAL—CHINN— PARK BOOK 0982 PAGE 0899 MAP BOOK 27 PAGE 7 —LOT 23A—R— SECTION 15 REVISED LANDMARK INDUSTRIAL PARK MAP BOOK 35 PAGE 257 I N 34*05,00. W 150.00' i —LOT 23—B— SECTION 21 w rn Z LANDMARK INDUSTRIAL O o a PARK MAP BOOK 37 PAGE 96 o u I � m EXISTING SANITARY SEWER EASEMENT / / = `42. EXISTING 30' DRAINAGE EASEMENT -- DRAINAGE AREA DIVIDE / / � / / � /— - ---"" N-`33'36'3� N 43'48'50" W 6zs•22 4}` W - 150?' SITE BOUNDARY / UMI�S OF DISTURBED-MEA 32 8' HIGH CHAIN LINK FENCE -- 'BdN 36'30" W 464. 47 7t!2�� �7 361 AllN ,\ o d -'� �, / / / STAGE APRON ��` GRAVEL STORAGE APRON � � l! i' 00 ._/._.:. .. .'. .._.. .... :.'.`.'.'. '_" 30" OAK I 20 o / 30' GRAVEL ROAD ° — — % 6TAL SITE 5' OAK OLLING ELEC. GATE ✓/ / 9.98 ACRES 18 $AK ° 91 ` I REF— E , / / / 2x25'x8" THK. REINF CED .! �— — g N I r f `TREES 1O REMAIN ' ��1' 15- PIF'-' = 100.OD ) CONCRETE APRON /� POLE STORAGE L=�OWN `� o �"- �---=- =20' (BUILDING PLANS S /�/ / AREA t2. Ae R N / �, 1s oA ,- NG GRAVEL / \ `6 . z" OAK p 1s OAK GENERATORj,• BUILDING PAD / / GRAVEL ROAD FF 41"50' TRANFORMER - 3 ROL NG ELEC GATE �qp a / 4af+�+l' 15" PINT PAD 110- or�K 12' PI e .gOQ / / � �' LIMITS OF DISTURBED AREA i 10'x100' CO CRE`TE 2 �f+E GRAVEL STORAGE APRON �' / 3 INE STOR�PGPRON 40 404'f ` - ` r / r / AK \` 4 `o a - 25' WATER ESNT. AK 1� ]i% ° l! ; •ice ,. — __.— --� / . RADIUS ENTRY SS MANHOLE RIM 34.42 WATER VALVEOtt, {�� DRIV' V E E.C.1 LA„DM ��� RI MANHOLE32.14 SS (60' PUBLIC R/W) 436.99' SO MANHOLE N 47'3810" W RIM 32.36 \tw\ k MANHOLE RIM 33.01 �25 WATER MAIN EASEMENT (EXISTING) LEGEND: ■ DI DROP INLET FES FLARED END SECTION DRAINAGE STRUCTURE NO. RL ROOF LEADER SO SURFACE DRAINAGE RCP REINFORCED CONCRETE PIPE \ LA LANDSCAPE AREA HC HC PARKING FH FIRE HYDRANT _n — SANITARY LINE EXTENSION _P — P — POTABLE WATER WITH BACK FLOW PREVENTER & METER - — - - — FIRE LINE EXTENSION IRRIGATION LINE 0 RT EXISTING REGULATED TREE OAK12" TYPE & CALIPER ASPHALT PARKING - SITE PLAN 60' 0 60' 120' SCALE: 1"=60' (Horiz.) ZONING NOTES: + EXISTING SITE HAS REGULATED TREES AS NOTED. + DEVELOPER WILL PROVIDE 15 TREES/ACRE IN ADDITION TO REGULATED TREES. 15x10Ac. = 150 TREES. . END OF PARKING ROW PLANTING AREAS NOTED AS LA, TO COMPLY WITH SECTION 19-175 OF THE CITY OF WILMINGTON ZONING ORDINANCE. • ZONING CLASSIFICATION - HM + STREET ADDRESS OF PROPERTY IS 404 RALEIGH STREET. 24- PINE �' p 15''OAK 1 OAK CLUSTER I I```� , OAK, \`—• \ . �f i%' O 15. I { 1 i ✓ p 18" OAI(- II NOTES: • PLANTING AREAS ADJACENT TO THE SIDEWALK TO RECEIVE CURB & GUTTER • SIDEWALK TO BE 7'-0" WIDE • SEE DRAWING E-104 FOR SITE LIGHTING • BOUNDARY AND TOPOGRAPHIC SURVEY BY MICHAEL UNDERWOOD AND ASSOCIATES.PA DATED NOVEMBER 1998. • SEE ELECTRICAL PLAN E101 FOR SIZE AND LOCATION OF TRANSFORMER AND GENERATOR PADS. • SEE FOR LANDSCAPE DATA. • NO WETLAND ARE ON SITE. BOOK O;�/9 A E 0 079 kE� EXISTING 30' DRAINAGE EASEMENT FEXISTING BUFFER YARD p CHARLEY E. RICHARSON— I F, BOOK 1336 PAGE 0277 115' _ _ REQUIRED TYPE B' BUFFER YARD OF EXISTING OR NEW VEGETATION CONSISTANT WIT',' 19-176 OF THE i CITY OF WILMINGTON ZONING ORDINANCE. :> W , toSD MANHOLE - - CIV IM 34.19 -1N CVV. 21.55 GO — J „ ----� c Q a Q Z o �( z� �o v o m z GO N 00 E a +.1ri 1 30 15' Z w N � �3- o ` m SO MANHOLE t1 RIM 27.98 tt INV. 21.11 INV. 21.00 -4- STORMWATE 61999 APPROVED NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DIVISION OF WATER QUALITY pats Sftmm w Pa O Ns.! `)7/a� N )m : s SI CAROLINA BEAC RD. U.S HWY 1 VICINITY MAP N.T.S. G REVISED DRAINAGE AREA AND LOCATION MAP. ADDED YARD DIMENSIONS FISSUED FOR TRC, SED & E.C. REVIEW MRD E ISSUED FOR DENR STORMWATER REVIEW DISSUED FOR FINAL DESIGN C JZM ISSUED FOR TRC REVIEW 11.6.98 B JZM ISSUED FOR PRELIMINARY REVIEW 11.2.98 A ISSUED FOR PRELIMINARY REVIEW 10 29 98 REV. # REV.BY DESCRIPTION DATE REVISIONS IPRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION v & v 7 Wilmington W, - = ; T-A I �Alj 0 ti: • North Carolina) W1 G PLAN CLIENT WING NUMBER M&C DRAAWWI— NM VIVI m N 34-05.00- W -LOT 23-13- SECTION 21 LANDMARK INDUSTRIAL PARK W MAP BOOK 37 PAGE 96 > z w o rn (3 o u W N N w o, f DRAINAGE AREA DIVIDE % - Q _ 33'36' 3f0' W "aN 43'48'50" W i6"23.22' _ 4L1_ - --_. 750.00' �?Q - - - / LMfS OF DISTU,RBEDJ AREAr - -- / - _ / s 'L SS MANHOLE RIM 34.42 ER VALVES b4 ` A�1/ RIVE HOLED MANHOLE LAN�M i\ SS MANHOLE \ RIM 33.01 RIM 32.14 1 (60' PUBLIC RIW) 436.99 SO MANHOLE N 47"35'10" W RIM 32.36 a i r' 12XO/24 IP NE �-"'- a 24" ..... a ..___ ..� 11 2V WATER MAIN EASEMENT (EXISTING) ASPHALT PARKING - SEDIMENTATION & EROSION CONTROL PLAN 60' 0 60' 120' SCALE: 1"=60' (Horiz.) EROSION CONTROL NOTES: NOT TO scNE y 1. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE LENGTH COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. --� N 2. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF 0 THE COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. S 3. 04. DISTURBED LAND AREA = 7.35 AC TEMPORARY SEEDING IS NECESSARY TO WIDTH 0 STABILIZATION IS THE BEST FORM OF EROSION CONTROL. ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY AS PART OF THE CONSTRUCTION SEQUENCE SHOWN ON THE PLAN. ALL GRADED SLOPES (n 4 REQUIRED OUTLET PIPE BE D AND MU CH DAYS OF COMPLETION OF GRADING. ALL REMAINING AMUST REAS ARE TO D MULCIHED5 ITHIN PLAN 6 5. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A 0. --1 REPRESENTATIVE OF THE COUNTY ENGINEERING DEPARTMENT. OUTLET PIPE STONE LINING CLASSIFICATION6. G SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. 7. ADDITIONAL DEVICES MAY BE REQUIRED AS AGREED BY FIELD INSPECTOR, ENGINEER, AND OWNER. 0UPON SECTION FON-I(WOVEN GEOTEXTILE 8. IF ACTIVE CONSTRUCTION CEASES IN ANY AREA FOR MORE THAN 15 DAYS ALL DISTURBED AREAS MUST BE SEE TABLE FOR OUTLET PROTECTION APRON DIMENSIONS. SEEDED, MULCHED, AND TACKED UNLESS WRITTEN APPROVAL IS GRANTED BY THE EROSION CONTROL OFFICER. REFER TO CMUD STD. /20.23 FOR ADDITIONAL REQUIREMENTS 9. FOLLOWING EVERY RAINFALL EVENT, CONTRACTOR SHALL INSPECT AND REPAIR AS NECESSARY ALL DAMAGED EROSION CONTROL MEASURES. OUTLET PROTECTION NOT TO SCALE SEEDBED PREPARATION 1. CHISEL,IFCOMPACTEDAREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL OUTLET PROTECTION SCHEDULE CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. OUTLET RIPRAP APRON 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. NUMBER DIA V CLASS THICKNESS LENGTH• WIDTH (IN) (F 0 (FT) 4. AGRICULTURALOW) LIME FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX (IN) (FPS) NTH SOIL FES 67 15 5. CONTINUE TILLAGE UNTIL A WELL - PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED POND OUTLET 4 8 1 1 12 1 14 IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED REESTABUSH FOLLOWING ORIGINAL UME, FERTILIZER AND SEEDING RATES. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABUSHED. . APPLY: AGRICULTURAL LIMESTONE - 2 TONS/ACRE FERTILIZER - 1000 LB5b0 S//ACRE 10-10-10 SUPERPHOSPHATE - LBS CRE (20 MULCH - 2 TONS/ACRE (SMALL GRAIN STRAW) ANCHOR - ASPHALT EMULSION AT 450 GAL/ACRE POND SCHEDULE: NORMAL WATER SURFACE 30.0 BOTTOM PERMANENT POOL 24.0 I �_' N 3'36'30" IN 464�47' .i OAK J o ` I, + \ 30 OAK PROTECT EXISTING TREES I / \,15, OAK \\ YA I I LIMITS OF (TYDl�l)RBED A EA SILT FENCEE PE 15 oAis I 12. OAK 0•.^12`.• OAK BOTTOM FOREBAY 27.0 TOP OF FOREBAY 30.0 CREST OF RISER 31.1 SIZE OF RISER 4'x4' RCP BOX CREST OF SPILLWAY 33.5 TOP OF BERM 35.0 STORAGE AT RISER ELEV. 59,576 C.F. BARREL 24" DIA. RCP DRAWDOWN ORIFICE 1 - 1.5" DIA. PVC ORIFICE ELEVATION 30.0 STORAGE AT ORIFICE ELEV. 44,765 C.F. GRADING NOTES 1. INITIATE EROSION CONTROL SEQUENCE BEFORE BEGINNING CLEARING AND GRADING OPERATIONS. 2. CLEAR AREAS TO BE GRADED OF ALL VEGETATION. PROTECT VEGETATION BEYOND GRADING LIMITS. 3. STRIP TOPSOIL TO FULL DEPTH IN AREAS TO BE GRADED AND STOCKPILE. 4. COMPACT ALL FILL AREAS TO 95% OF MAXIMUM DENSITY. 5. ALL BANKS AND SWALE SIDE SLOPES SHALL BE GRADED WITH NO GREATER THAN 3:1 SLOPES. 6. ALL AREAS ARE TO BE GRADED SO THAT NO AREAS OF STANDING WATER OCCUR. 7. PROPOSED SPOT ELEVATIONS ARE SHOWN AT FINISHED GRADE. B. OPERATOR SHALL FIELD VERIFY EXISTING TOPOGRAPHY IN RELATION TO THE PROPOSED GRADES TO ENSURE DRAINAGE IN THE DIRECTIONS INDICATED ON THE PLAN. 7 lr�, --�--\------=�-j�-=3��--� 1---- I I I DATE SEEDING SCHEDULE TYPE PLANTING RATE AUG. 15 - NOV. 1 TALL FESCUE 300 UIS/ACRE NOV. 1 - MAR. 1 TALL FESCUE 300 LBS/ACRE & ABRUZZI RYE 25 LBS/ACRE MAR. 1 - APR. 15 TALL FESCUE 300 LBS/ACRE APR. 15 - JUN. 30 HULLED COMMIX) BERMUDAGRASS 25 LBS/ACRE JUL 1 - AUG. 15 TALL FESCUE AND 120 LBS/ACRE sn BROWNTOP MILLET 35 LBS/ACRE ••. OR SORGHUM - SUDAN HYBRIDS 30 LBS/ACRE CONSULT CONSERVATION ENGINEER OR SOIL CONSERVATION SERVICE FOR ADDITIONAL IN FORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. ••s TEMPORARY -- RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12•IN HEIGHT BEFORE MOWING, OTHERWISE FESCUE MAY BE SHADED OUT. dooK 0279 q e 0079 9 CHARLEY E. RICHARSON- BOOK 1336 PAGE 0277 2 � SD MANHOLE RIM 31.55 CN INV. 21.55 Ot -- U Q Q 2 ID z O - 0 O C) 0 m U -2- Q 4e v/ m � Z Q IN 43152'00" E 30.15' co 10 z N rn -3- 11 . m -4- SO MANHOLE i l ` RIM 27.96 V - 1 1 INV. 21.11 INV. 21.00 , CONSTRUCTION SEQUENCE 1. REQUEST PRECONSTRUCTION CONFERENCE PATH COUNTY EROSION INSPECTOR (341-7139) 2. INSTALL GRAVEL CONSTRUCTION ENTRANCE, PERIMETER SILT FENCE AND TREE PROTECTION FENCING. 3. BEGIN CLEARING AND GRADING OPERATIONS TO CONSTRUCT DETENTION POND (TO BE USED AS SEDIMENT TRAP DURING CONSTRUCTION). 4. COMMENCE GRADING OPERATIONS FOR BUILDING, PARKING LOT AND UTILITY CONSTRUCTION. 5. PROVIDE INLET PROTECTION DEVICES AS REQUIRED UNTIL PAVEMENT IS COMPLETE AND FINAL GRADES ARE STABIUZED WITH VEGETATIVE COVER. 6. STABILIZE ALL DISTURBED AREAS AS SOON AS FINAL GRADES ARE ESTABLISHED. 7. REMOVE TEMPORARY CONTROL DEVICES (SILT FENCE, ETC.) ONCE PERMANENT VEGETATIVE COVER IS ESTABLISHED. NOITES s SITE N� CAROLINA BE AC RD. U.S HWY 1 VICINITY MAP N.T.S. LEGEND: ■ DI DROP INLET 10 FES FLARED END SECTION DRAINAGE STRUCTURE NO. 0 RL ROOF LEADER SO SURFACE DRAINAGE RCP REINFORCED CONCRETE PIPE LA LANDSCAPE AREA HC HC PARKING } FH FIRE HYDRANT - ss - ss - SANITARY LINE EXTENSION - P - P POTABLE WATER WITH BACK FLOW PREVENTER & METER - - FIRE LINE EXTENSION IRRIGATION LINE 0 RT EXISTING REGULATED TREE OAK12" TYPE & CALIPER JAR C REVISED AGE AREA 2.15.99 AND LOCATION MAP R9 B REVISED PER E.C. COMMENTS 1 99 RDL A ISSUED FOR TRC, SED. & E.C. REVIEW 12.13.98 REV. REV.BY # DESCRIPTION DATE REVISIONS PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION FOR REVIEW AGENCY APPROVAL 14 v Wilmington North Carolina) a• aFE /� 2 S = 867 111811111110 Alti~ L1.011 ilk WWI 0 11�'e ` CLIENT DRAWING NUMBER M&C DRAWING NUMBER =2 ?i i -LOT 23-B- SECTION 21 LANDMARK INDUSTRIAL PARK MAP BOOK 37 PAGE 96 EXISTING 30' DRAINAGE EASEMENT 4 42 rt&ix�l 30' 0 30' 60' SCALE: 1"=30' (Horiz.) EXISTING SANITARY SEWER EASEMENT - N 3336'30" W DRAINAGE AREA DIVIDE 623 22' -- — N 43_48 50' W — _ — �� -.�__ ►. LIMJOF DISTURBED AREA EXISTI�G� FH N O/ R=20' �►�"FA i 1� ��� ��a RADIUS ENTRY NG 10' LANDSCAPING BUFFER CONNECT TO EXIST. SAN. SEWER 1-1/2" TAP TO EXIST. WATER MAIN / 1-1/2" WATER METER BY CITY. CONTRACTOR TO PROVIDE BACKFLOW PREVENTER I2" TAP TO EXIST. WATER MAIN 2" WATER METER BY CITY (IRRIGATION SERVICE). CONTRACTOR TO PROVIDE BACKFLOW PREVENTER. O, / 8' HIGH CHAIN LINK FENCE _ -� CONC. PVMT. DI 33.62 �6 'SETB ACC -- RADIUS ENTRY 6' — HVAC CONDENSI UNITS WI7FT CETA \ SCREEN Z FH SS MAIJHOLE RIM 34.42 � \ rag I f% 30' J/ p2 GENERATOR PAD / 55 TRANFORMER AD CONC. PVMT. o �- / 0 x1 CONCRETE STOfYAGE APRON 11 ROLLING ELEC. GATE % GRAVEL ROAD < 72 "15'x THK. REINFORCED / / — CONCRETE APRON / / GRAV / �— ROLLING LEC. GATE 10`x100' I STORAGE 35 25' WATER ESMT. GRAVEL STORAGE I GRAVEL ROAD r 'GE APRON STORAGE APRON SEE DETAIL SHT. C105 _ _ 7,=— '�..,_.._,..-- FH r. 6" WATEF� MkN� r ---`---- — — — _�--------------------------------------------- - — — — — — — — — — — — — — — — — — 25' WATER MAIN EASEMENT (EXISTING) -ASPHALT PARKING D n r m m NdiEB� LEGEND: ■ DI DROP INLET ► FES FLARED END SECTION O DRAINAGE STRUCTURE NO. RL ROOF LEADER SD SURFACE DRAINAGE RCP RIGID CONCRETE PIPE LA LANDSCAPE AREA HC HC PARKING * FH FIRE HYDRANT —w—a— SANITARY LINE EXTENSION —. —. — POTABLE WATER WITH BACK FLOW PREVENTER & METER ------- FIRE LINE EXTENSION IRRIGATION LINE 0 RT EXISTING REGULATED TREE OAK12" TYPE & CALIPER JAR H REVISED DRAINAGE AREA, ADDED SPOT GRADES AND ELEVATIONS 2.15.99 99 G ADDED NOTE TO FES #6 1.1 F ISSUED FOR TRC. SED. & E.C. REVIEW 12R1SDL 98 RDL E FOR DENR STORMWATER REVIEW 11.21.98ISSUED JZM D ISSUED FOR FINAL DESIGN C ISSUED FOR TRC REVIEW 11J6 9$ B ISSUED FOR PRELIMINARY REVIEW 11 2 98 A ISSUED FOR PRELIMINARY REVIEW 10 9M98 REV. REV.BY DESCRIPTION DATE # REVISIONS PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION v Ni�I�VI� v LIffillmington North Carolina J DRAWN : JZM PROJECT 0159-0081.OW NUMBER : DESIGN : RDL CHECK: RDL SCALE : 1'-30' APPROVED : SLN DATE : 21 NOV 98 FILE NAME : S:\O159\0081\C101_F.dwg 00 CLIENT DRAWING NUMBER M&C DR��AWINAO NUMBER ` N L Q NASPHALT PARKINGN I 25' WATER_'MAIN EASEMENT (EXIST[N f 4 �i 30' 0 30' 60' SCALE: 1"=30' (Horiz.) EXISTING 30' DRAINAGE EASEMENT EXISTING BUFFER YARD ~ROGER T 600K 0��9 P O�kEti GE 0079 CHARLEY E. RICHARSON— BOOK 1336 PAGE 0277 REQUIRED TYPE 'B' BUFFER YARD OF EXISTING OR NEW VEGETATION CONSISTANT WITH 19-176 OF THE CITY OF WILMINGTON ZONING ORDINANCE. w UD CID 0 SD MANHOLE RIM 34.19 / INV. 21.55 z c� NOTM LEGEND: ■ DI DROP INLET No FES FLARED END SECTION O DRAINAGE STRUCTURE NO. RL ROOF LEADER SD SURFACE DRAINAGE RCP REINFORCED CONCRETE PIPE LA LANDSCAPE AREA HC HC PARKING FH FIRE HYDRANT —s—a— SANITARY LINE EXTENSION —. —. — POTABLE WATER WITH BACK FLOW PREVENTER & METER ------- FIRE LINE EXTENSION IRRIGATION LINE 0 RT EXISTING REGULATED TREE OAK12" TYPE & CALIPER G ADDED FOREBAY DIMENSIONS 2 15 99 IF ISSUED FOR TRC, SED. & E.C. REVIEW 12R 3L95 E ISSUED FOR DENR STORMWATER REVIEW " 2 96 JZM D ISSUED FOR FINAL DESIGN zm C ISSUED FOR TRC REVIEW �,J6 9S B ISSUED FOR PRELIMINARY REVIEW 11JZ 98 A ISSUED FOR PRELIMINARY REVIEW 0 29 98 10099 REV. REV.BY DESCRIPTION DATE # REVISIONS PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION IN wlmington North Carolina WILMINGTON SOUTH OPERATIONS CENTER rn CLIENT DRAIMNG NUMBER MIX [DRAIMNG N�,UMBER V .N LINE S MN. F112-1 2 GUAR: PPE OUTLET TO FLAT AREA NO HELL -DEFINED CHANNEL FLAW La NOTES: 1. La IS THE LENGTH OF THE RPRAP APRON. 2. 6 " 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6. 3. N A WELL - DEFINED CHANNEL EX- TEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6' ABOVE THE MAXIMUM TNLWATER DEPTH OR TO THE TOP OF THE BANK. WMCIEVER IS LESS, 4. A FILTER BLANKET OR FILTER FABRIC SNOLW BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. STANDARD DETAIL CITY OF WILMINGTON PIPE OUTLET ENGINEERING PROTECTION DEPARTMENT SO 2-15 TOP STRAND MN /10 OUAGE A STAY WIRES MN. /12-1/2 WAGE BOTTOM STRAND MIN. /10 GUAGE NOTES: AAFLLL gE Uy 1. AYIOIH AMO SHAL4MHIAA A WIMUM OF 6 LINE WwES W/12 STAY SPACING I FILTER FABRIC SHALL BE A MINIMUM OF 36' N WIDTH AND SHALL BE FASTENED ADEQUATELY TO THE ARE AS DIRECTED BY THE3. STEEL POSS SHALL BE 5' D' N HMT AND BE OF SELF FASTENER ANGLE STEEL TYPE 4. WOOD POSTS SH4L BE A MINIMUM OF 6' N HEIGHT AND 3 OR MORE IN DIAMETER ARE FABRIC SHALL BE FASTENED TO WOODEN POST TH NOT LESS THAN 09 UK STAPLES 1-1/2�LONG IER FABRIC FILL SLOPE ANCHOR FILTER FABRIC SKIRT AS DIRECTED BY THE ENGINEER JIANUAKU I/LINL CITY OF WILMINGTON GUIDELINES FOR ENGINEERING TEMPORARY SILT DEPARTMENT FENCE DETAIL So 13-01 ELEVATION V \ CROWN OF TREE IS NEEDED FOR LEAF GROWTH TO PRODUCE OXYGEN FILTER /•i1\\� �.� / I INSENSITIVETha DOODISFIW� NTH � I PLNE PLAN �7J� `� STRUCTURAL. ROOTS FEEDER ROOTS �N STRUCTURAL FMOTSTRUNK LOCATED NEAR BASE OF TRUNK ARE FEEppt ROOTS NE LOCATED NEEDED TO qY£ SUPPORT TO AT MPUNE' OF THEE ENTIRE TREE F TENONED AND PROVE WE WITH TREE CANFAIL AND DAMAGE MOISTURE AND NUTRIENTS PROPERTY. NOTE .2 k NOTE 4 SEE NOTE 1 t NOTE 4 TREE PROTECTION DURING CONSTRUCTION 1. DO NOT COMPACT SOIL BENEATH TREES NO VEHICLE SHALL BE ALLDWED TO PARK UNDER TREES NO HEAVY MATERIALS SHALL BE �ORTMEDE�S. RESULTS OF COMPACTION CAUg WATER AND NR HOT To REA WILL DE THESE 'FEEDIIttIG R001 OCCUR WELL AWAY FROM THE BASE OF THE TREE TO THE EDGE OF THE OVERHEAD BRANCH CANOPY. DAMAGING THE BARK NTH LAWIlMOWE(S, CONSTRUCTION EQUIPMENT. OIL ANYTHING ELSE IS PROMOTED. APROTECTIVE BARRIER SHDIRD PREVENT DAMAGE FROM OOCIURING DURING CONSTRUCTION. 2. NO CUTTING OF LARGE STRUCTURAL ROOTS LOCATED NEAR THE BASE OF THE TRUNK. THESE ARE ESSENTIAL N SUPPORTING THE ME AND HOLDING IT UPRIGHT IN HIGH WINDS. REMOVAL OF THESE ROOTS ALONG ONE SIDE IS OFTEN DONE BECAUSE OF A WALK, PAVING OR BUILDING WHICH IS BEING CONSTRUCTED. 3. AVOID CUT AND FILL WITHIN DIAMETER OF TREE CROWN DURING EXCAVATION STANDARD DETAIL CITY OF WILMINGTON METHOD OF TREE ENGINEERING PROTECTION DURING DEPARTMENT CONSTRUCTION So 15-09 DEWMERNG CONCRETE BLOCK - o 0 L= 00 0 CD o a o g o �2:1 SLOPE,GRAVEL FILTER TEMPORAPY SEDIMENT 1 WILE SCREEN DEWATERING POOL ,.. .,.... 0 V MIN 2' MAX HIE I=-IN=-w=w=NIL=1=ul=iu=m=m=m=n �•: - _=111=1118111 11811181IIBIII=III=111 .... III=1Ti DROP INLET WITH GRATE SEDIMENT CONSTRUCTION SPECIFICATIONS 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE N THE BOTTOM Row TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BROW TM CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS IFJEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2X4 WOOD STUDS TMOUGH BLOCK OPENINGS. 2. CAIEFULLY FIT HARDWARE CLOTH OR COMPARABLE WALE MESH WITH 1/2-INCH OPENINGS OVA ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3. U9 CHEW GRAVEL 3/4 TO T/2-NCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE DOT #57 wIDED STONE IS RECOMMENDED. STANDARD DETAIL CITY OF WILMINGTON DROP INLET ETNGIMlRNG PROTECTION DEPARTMENT SO 2-14 MOTE;: a GRUEL PAD TO DE 12'x 60' AND 6' HOICK MINIMUM D. TURNING RADIUS SUPIC ENT TO ACCUMODATE LARGE TRUCKS IS TO BE PROVED. a ENTMICE(S) SHOULD BE LOCATED TO PROW FOR MAXMUM UTILITY BY ALL CO MtUCTION VEHICLES A MUSBE MAINTAINED N A CONDITION WHIG WALL PREVENT TRACKING OR DREG FLOW OF MUD ONTO STREETS. PERIDIC TOPORESSNG WAIN S. SILL E NECESSARY. KEEP SONS NARY. a ANYNATERIAL WHICH SILL MAKES IT ONTETHE ROAD MUST BE CLEANED UP NLIE,ATELY. NOTES APPUCIAE AT ALL PUNTS OF 94MSS k EGRESS UNTIL STE IS STABIUZED, FREQUENT CHECKS OF THE DEMCE AND TIMELY MAINTENANCE MOIST BE PROVIDED. COARSE AGGREGATE J 2-3' TEMPORARY CONSTRUCTION ENTRANCE/EXIT NC606AD 1 - GRADE POND TO ELEVATIONS SHOWN ON THE PLANS TOP RISER 31.1 NWSE=30.O 4'x 4' PRECAST BOX (SEE RISER SECTION) 00,00001- N TOP OF DAM EL. 35.0 ' 3 5'x 5' CONC. COLLARS 1_ WITH LOCKING CO6 RINGL NV 29.0 JOINT OUT = 27.00 CUT OFF L \-NON-WOVEN TRENCH OUTLET PROTECTION GEOTEXTILE FABRIC CLASS 'B' STONE 18'Lx9'Wx18"THK. POND #9-1 OUTLET STRUCTURE SECTION NOT TO SCALE A'41- 'OURED IN PLACE- %ONCRETE COLLAR WATERPROOF MASTIC (TYP.)- POURED IN PLACE CONCRETE COLLAR 'TYPICAL EACH FACE) ANTI -SEEPAGE COLLAR DETAIL O PLAN STORM EL.. _ FOR, ®AY 100 . EL.; \ �1 NOT TO SCALE CONTRACTOR TO PROVIDE ANGLE IRONS AND SAFETY GRATE. 'RECAST BOX MODIFY GRATE AS NEEDED TO ENCLOSE PROTRUDING BARREL/ 24" R P 1.500 PVC ORIFIC j 30.0 NWSE _( ivy. A. Io T Ko NOTE: CONTINUOUS RUBBER WATER STOP AT ALL CONSTRUCTION JOINTS SECTION PRECAST RISER/BARREL STRUCTURE NOT TO SCALE I _ 1 /2" " 0 I RFYTTOM N x 4' PRECAST BM TOP EL FORE BAY VEGETATIVE SHELF TOP OF RISER VEGETATTIE SHELF 6:1 SLOPE TYP. a!V 1:1 SLOPE TYP. AROUND POND AROUND POND TOP OF DAM EL = 35.0 ... ... .. STORAGE EL .. ..PERMANENT POOL EL NORMAL WATER SURFACE 30.0 1 CREST OF LOW FL 907TOM EL FORE BAY = 27.0 1 1 i0 BOTTOM PERMANENT POOL ELF 24.0 FOREBAY AND STORAGE POND SECTION NOT TO SCALE STORMWATER RocalveD FEB 2 310 NOTES: STRUCTURAL NOTES: 1. CONCRETE DESIGN IS BASED ON THE FOILDNNG STANDARDS BUILDING CODE REQUIREMENTS FOR ROWORCED CONCRETE (ACI 318-89) AND ALL SUBSEQUENT SUPPLEMENTS. 2. CAST N PLACE CONCRETE DESIGN IS BASED ON THE FOLLOWING MATERIAL STRENGTH: A. CONCRETE (AT 28 DAYS): 4000 IS (.46 MAX WATER CUM RATIO) B. REINFORCING STEEL ASIM A6V% GRADE 60: FY . 60,000 PSI 3. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS: A CAST AGAINST AND PERMANENTLY E)POSED TO EARTH . 3' B. EXPOSED TO EARTH, WATER OR WEATHER, WHERE FORMS ARE USED - 2' 4. CHAMFER ALL EXPOSED CORNERS OF CONCRETE NTH 3/e X 45' CHAMFER, UNLESS OTHERWISE NOTED. 5. ALL CONCRETE WORK SHALL BE DONE N ACCORDANCE WITH -SPECIFICATIONS FOR STRUCTURAL CONCRETE N BUILDINGS' ACI 3D1 AND ACI PUBLICATION ACI-35MM 'ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES'. 6. UNLESS NOTED OTHERWISE, ALL SPLICES, BENDS, STANDARD HOOKS AND OTHER DETAILING OF REINFORCEMENT SHALL BE AOCONPUSH D AS RECOMMENDED IN THE 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES* ACI 315 AND ACI 318-89. 7. FORM FINISH IS ACCEPTABLE FOR WALLS, FLOAT FINISH SLAM RUB EXPOSED SURFACES & CONTINUOUS RUBBER WATERSTOPS SHALL BE PROVIDED AT ALL CONSTRUCTION JOINTS IN RISER. 9. PRECAST MANUFACTURER TO PROVIDE /5 DIAGONALS AROUND PIPE OPENING N RISER BOX IN EACH FACE B ROL ISSUED FOR TRC, SED. NTL E.C. REVIEW 12.13.98 OL '4 ISSUED FOR DENR STORMWATER REVIEW 11R25.98 REV. REV.BY # DESCRIPTION DATE REVISIONS PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION FOR RENEMI AGENCY APPROVAL v MtTQM& Wilmington North Carolina j CLIENT DRAWANG NUMBER M&C �DRAWNG NUMBER V LW RADIUS ENTRY 10' LANDSCAPING BUFFER RADIUS ENTRY LANDMARK DRIVE (60' PUBLIC R/W) -LOT 23-B- SECTION 21 LANDMARK INDUSTRIAL PARK MAP BOOK 37 PAGE 96 44 EXISTING SANITARY SEWER EASEMENT / a5 / / INVERT E INVERT S SS MANHOLE RIM 34.42 �Q, r QO LOT 23A-R- SECTION 15 REVISED m r LANDMARK INDUSTRIAL PARK \ MAP BOOK 35 PAGE 257 EXISTING 30' DRAINAGE EASEMENT 8' GH CHAIN LINK FENCE ��— �r TOP 3as6' / 10'x1 0' CON C E —z INVERT W .08" S ORAGE AP ON GRAVEL STORAGE APRON / ROLLING ELEC. GA E GRAVEL ROAD_ DI TDP 39.39' BUILDING r INVERT N 35,80' F.F. EL. = 100)� GENERATOR - / z INVERTS 35,79" �T PAD / GRAVEL ROAD ANFORMER ROLL ELEC ATE \ //gPAD � \ / 10'x100, CON TE GRAVEL STTtr G APRON j STORA PRON M. / �CL SWALE 18"RCPI / i — VERT 33.45" 51 DI C TOP _Z7-68' ,INVERT N 34.73 INVERT S 54.72 DI CP TOP 39.21' INVERT N 35.35' INVERT S 3 / — 34�/ ��3 c C CON�JNVfS i VEGF�YATIVE SI`,REEN \ I( \I 2 \ / EC.1 � 1 $S MANHOLE SS MANHOLE g RIM 32.14 �" 61 RIM 33.01 G SD MANHOLE � RIM 32.36 NOTE: FIELD SURVEYS PERFORMED BY MCKIM AND CREED ON JULY 17 AND 18, 2008 / x25'xB" THK. REINF CED CONCRETE APRON TORAGE LAYD15" YARD Area = t2.26 ?,cam VING GRAVEL ti 3 FOREBAY STORAGE EL. = 31.76' FOREBAY POOL EL. 3 �1 CL SWALE SCALE: 1" =50' 0 25 50 100 150 ELEVATIONS ARE BASE) OFF OF EXISTING CONDITIONS MAP DATE) 1998.' DATUM IS ALSO NA VD 88 +2.16'. TOTAL SITE Area = _+.9.98 Ac. 1 I I \ \ I WSE 24.41'7-17-08 \\l1 I 26_27 \ _\' 3 POND STRUCTURES 1 31.76' IN RT 24" RCP = 29.76' IN VE = 6 30 a \ A —INVERT RCP INVERT 2716'__ TOP EL FORE BAY g' w 6' / VEGETATIVE SHELF D z TOP OF RISER VEGETATIVE SHELF 6:1 SLOPE TYR. of ov 6:1 SLOPE TYR. AROUND POND >a AROUND POND TOP OF DAM EL. = 33.60' (DESIGN = 35.0') IGN = 31.1') STORAGE EL. = 31.76' DESIGN = 31.1' ~2 PERMANENT POOL EL. = 30.76' DESIGN = 30.0' 3 24" RCP INV. OUT EL.= 27.16' m a 1 CREST OF LOW FLOW R a (DESIGN = 27.0') w 3 (DESIGN = 30.0') w 3 INV. EL 29.76' o (DESIGN = 29.0') FOREBAY BOTTOM EL = 28.78' (DESIGN = 27.0') 1 1 io n BOTTOM PERMANENT POOL 1p EL.= 24.32' (DESIGN = 24.0') FOREBAY AND STORAGE POND SECTION NOT TO SCALE DI I TOP 31.00' INVERT 29.49' I \ 4 1 �. S`% IMV. 2 28_ '�R 0 eooK \, 9 pq 0 DC G� C)07 EXISTING 30' DRAINAGE EASEMENT EXISTING BUFFER YARD CHARLEY E. RICHARSON I BOOK 1336 PAGE 0277 I REQUIRED TYPE 'B' BUFFER YARD OF EXISTING OR NEW VEGETATION CONSISTANT WITH 19-176 OF THE ^ITY 0"r Wl !iidGTGN' TONING ORDINANCE. SD MANHOLE RIM 34.19 INV. 21.55 QC) a � z0 1 I O N2N �o zm a j —3— DWGFILE FIIFQA IF n7/99/0fl FIIFTIMF 7200 AM RADIUS ENTRY 10' LANDSCAPING BUFFER RADIUS ENTRY LANDMARK DR�vE (60, PUBLIC RAW) \ -LOT 23-B- SECTION 21 LANDMARK INDUSTRIAL PARK MAP BOOK 37 PAGE 96 / �4 EXISTING SANITARY SEWER EASEMENT 45/ _ -------�— � 8GH CHAIN LINK FENCE -� TOP 39.96' INVERT W ,ri)n- 36. ss' INVERT E S6. INVERTS 36 \ Dl DI BUILDING TOP 39.3935.80' F.F. EL. = 100.0' INVERT N SS MANHOLE RIM 34.42 \x ) D/ ' TOP 39.21' INVERT N 35.35' INVERT S 35-ge \ ,C CONDE -I VEG�T'A \ Ir \I 2 , \ E.C.1 SS MANHOLE p RIM 32.14 61 -0 G� SO MANHOLE RIM 32.36 II nn n V A D/ TOP _Jy68' -INVERT N 34. INSERT S 34. JNITS EN $S MANHOIE RIM 33.01 101x100' CON C E —/ CRAG E AP ON GRAVEL STORAGE Al / ROLLING ELEC. G JE / GRAVEL ROAD_ --�_ -LOT 23A-R- SECTION 15 REVISED LANDMARK INDUSTRIAL PARK MAP BOOK 35 PAGE 257 EXISTING 30' DRAINAGE EASEMENT / x25'x8" THK. REINF CED CONCRETE APRON TORAGE LAYb&" YARD Area = t2.26 1 / VING GRAVEL 3 \GENERATOR / PAD / GRAVEL ROAD Tggg ANFORMER ROLL ELEC ATE \ PAD 10'x100' CON TE % GRAVEL STTbR-AGI< APRO� ! TOR PRON 78 RCPI ✓ERT 33.45' 31 CL SWALE CL SWALE J \ 4� N� 11 SCALE: 1" =50' 0 25 50 160 150 ELEVATIONS ARE BASED OFF OF EXISTING CONDITIONS MAP DATED 1998. DATUM IS ALSO NA✓D 88 +2.16'. TOTAL SITE Area = -9.98 Ac. I I I I \ \ I WSE 24. 41' I / 7-17-08 � \I ram- 26 27 00 \ II POND O L ImuCTURE I I I = 31.76' I IN PT 24" RCP = 29.76' Top IN✓E .5"fI = 6 0P 31.00' INVERT 29.49' N IN,V. 2 zo— 1 24" RCP —INVERT 2716'- n II FOREBAY TOP EL FORE BAY 6' w 0 6' 3 VEGETATIVE SHELF D z TOP OF RISER VEGETATIVE SHELF 1 6:1 SLOPE TYP. of o0 6:1 SLOPE TYP. AROUND POND >o AROUND POND TOP OF DAM EL. = 33.60' (DESIGN = 35.0') STORAGE EL. = 31.76' (DESIGN = 31.1') STORAGE EL. = 31.76' DESIGN = 31.1' ~ l k FOREBAY POOL EL. NWS PERMANENT POOL EL. = 30.76' DESIGN = 30.0' 3 F 1 3 F 24" RCP (DESIGNOUT EL27A) .16' CREST OF LOW FLOW IR a 1 °' w 3 (DESIGN = 30.0') wQ 3 =2? _ � FOREBAY BOTTOM EL. = 28.78' (DESIGN = 27.0') (DESIGN290') � 1 1 BOTTOM PERMANENT POOL 1O EL.= 24.32' (DESIGN = 24.0') xx NOTE: FIELD SURVEYS PERFORMED BY MCKIM FOREBAY AND STORAGE POND SECTION AND CREED ON JULY 17 AND 18, 2008 NOT TO SCALE 28 � EFILE CN101-01590227.DWG •\ CH � Q 0) �o �vo 0 Z m � r o 2 m /\�ROe a00K 0� 9 qc DC E 007 EXISTING 30' DRAINAGE EASEMENT EXISTING BUFFER YARD CHARLEY E. RICHARSON BOOK 1336 PAGE 0277 - REQUIRED TYPE 'B' BUFFER YARD OF EXISTING OR NEW VEGETATION CONSISTANT WITH 19-176 OF THE mil ( 9 'VVILMINGi0N ZONING ORDINANCE. _ SO MANHOLE -RIM 34.19 NV. 21.55CO C Q O O CD v \ — —2m � zm C —3— PROGRESS ENERGY CAROLINAS, INC. RALEIGH, N.C. STORMWATER MANGEMENT PLAN RECORD DRA WINGS WILMINGTON SOUTH OPERATIONS CENTER L OCA TION WILMINGTON, N. C. Scale 1 -50 Date 22✓ULY08 Drawn by ✓RL Checked by RAM Approved by RAM Dwg. No. 0159-0227 FILEDA TE 07/29/08 FILE TIME 10:GO AM Sheet 77.1/1 Sh t DWGFIL