HomeMy WebLinkAboutSW8001009_HISTORICAL FILE_20050110STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO.
SW8 oo1oo°I
DOC TYPE
❑ CURRENT PERMIT
❑ APPROVED PLANS
HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
2005 W 10
YYYYMMDD
�OF VNArF'Y Michael F. Easley, Governor
�O G William G. Ross, Jr., Secretary
North Carolina Department of Environment and Natural Resources
Y Alan W. Klimek, P.E. Director
Division of Water Quality
Januray 10, 2005
Rick Blacher, Owner
Smith Creek Storage Facilities, Inc.
5633 Market Street
Wilmington, NC 28405
Subject: Stormwater Permit No. SW8 001009 Modification
Smith Creek Storage Facility Phase I
High Density Project
New Hanover County
Dear Mr. Blacher:
The Wilmington Regional Office received a complete Stormwater Management Permit Application for
Smith Creek Storage Facility Phase I on December 17, 2004. Staff review of the plans and
specifications has determined that the project, as proposed, will comply with the Stormwater
Regulations set forth in Title 15A NCAC 21-1.1000. We are forwarding Permit No. SW8 001009
Modification dated January 10, 2005, for the construction of the subject project.
This permit shall be effective from the date of issuance until January 10, 2015, and shall be subject to
the conditions and limitations as specified therein. Please pay special attention to the Operation and
Maintenance requirements in this permit. Failure to establish an adequate system for operation and
maintenance of the stormwater management system will result in future compliance problems.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within thirty (30) days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North
Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447,
Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding.
If you have any questions, or need additional information concerning this matter, please contact
Rhonda Hall, or me at (910) 395-3900.
Sincerely,
Rick Shiver
Regional Supervisor
Surface Water Protection Section
RSS/rbh: S:\WQS\STORMWAT\PERMIT\001009mod.jan05
cc: James Honeycutt, P. E., Honeycutt Engineering
Joseph Gray, III, TMC-Taylor Construction, Inc.
New Hanover County Building Inspections
City of Wilmington Stormwater Services
Beth E. Wetherill, New Hanover County Engineering
Rhonda Hall
(Wilmington -Regional Office
Central Files
North Carolina Division of Water Quality 127 Cardinal Drive Extension Phone (910) 395-3900 Customer Sewicel-877-623-6748
Wilmington Regional Office Wilmington, NC 28405-3845 FAX (919) 733-2496 Internet: h2o.encstate.nc.us One
An Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper Natumllil
State Stormwater Management Systems
Permit No. SW8 001009 Modification
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
STATE STORMWATER MANAGEMENT PERMIT
HIGH DENSITY DEVELOPMENT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of
North Carolina as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Richard Blacher, Smith Creek Storage Facilities, Inc.
Smith Creek Storage Facility Phase 1
New Hanover County
FOR THE
construction, operation and maintenance of a wet detention pond in compliance with
the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules')
and the approved stormwater management plans and specifications and other
supporting data as attached and on file with and approved by the Division of Water
Quality and considered a part of this permit.
This permit shall be effective from the date of issuance until January 10, 2015, and
shall be subject to the following specified conditions and limitations:
I. DESIGN STANDARDS
This permit is effective only with respect to the nature and volume of stormwater
described in the application and other supporting data.
2. This stormwater system has been approved for the management of stormwater
runoff as described in Section 1.6 on page 3 of this permit. The stormwater
control has been designed to handle the runoff from 111,929 square feet of
impervious area.
3. The tract will be limited to the amount of built -upon area indicated on page 3 of
this permit, and per approved plans. The built -upon area for the future
development is limited to 2,221 square feet.
4. All stormwater collection and treatment systems must be located in either
dedicated common areas or recorded easements. The final plats for the project
will be recorded showing all such required easements, in accordance with the
approved plans.
5. The runoff from all built -upon area within the permitted drainage area of this
project must be directed into the permitted stormwater control system.
Page 2 of 7
State Stormwater Management Systems
Permit No. SW8 001009 Modification
6. The following design criteria have been provided in the wet detention pond and
must be maintained at design condition:
a.
Drainage Area, acres:
3.64
Onsite, ft :
158,449
Offsite, ftz:
None
b.
Total Impervious Surfaces, ftz:
111,929
C.
Design Storm, inches:
1
d.
Pond Depth, feet:
6.5
e.
TSS removal efficiency:
90%
f.
Permanent Pool Elevation, FMSL:
24.00
g.
Permanent Pool Surface Area, ftz:
6,603
h.
Permitted Storage Volume, ft3:
10,159
i.
Temporary Storage Elevation, FMSL:
25.37
j. Controlling Orifice:
k. Permitted Forebay Volume, ft3:
I. Receiving Stream/River Basin:
M. Stream Index Number:
n. Classification of Water Body:
II. SCHEDULE OF COMPLIANCE
1.5'0 pipe
3,018
Spring Branch / Cape Fear
18-74-63-1
"C: Sw,,
1. The stormwater management system shall be constructed in its entirety,
vegetated and operational for its intended use prior to the construction of any
built -upon surface.
2. During construction, erosion shall be kept to a minimum and any eroded areas of
the system will be repaired immediately.
3. The permittee shall at all times provide the operation and maintenance
necessary to assure the permitted stormwater system functions at optimum
efficiency. The approved Operation and Maintenance Plan must be followed in
its entirety and maintenance must occur at the scheduled intervals including, but
not limited to:
a. Semiannual scheduled inspections (every 6 months).
b. Sediment removal.
C. Mowing and revegetation of slopes and the vegetated filter.
d. Immediate repair of eroded areas.
e. Maintenance of all slopes in accordance with approved plans and
specifications.
f. Debris removal and unclogging of outlet structure, orifice device, flow
spreader, catch basins and piping.
g. Access to the outlet structure must be available at all times.
Page 3 of 7
State Stormwater Management Systems
Permit No. SW8 001009 Modification
4. Records of maintenance activities must be kept and made available upon
request to authorized personnel of DWQ. The records will indicate the date,
activity, name of person performing the work and what actions were taken.
5. Decorative spray fountains will be allowed in the stormwater treatment system,
subject to the following criteria:
a. The fountain must draw its water from less than 2' below the permanent
pool surface.
b. Separated units, where the nozzle, pump and intake are connected by
tubing, may be used only if they draw water from the surface in the
deepest part of the pond.
c. The falling water from the fountain must be centered in the pond, away
from the shoreline.
d. The maximum horsepower for a fountain in this pond is 1 /8 horsepower.
6. The facilities shall be constructed as shown on the approved plans. This permit
shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans and specifications, and other
supporting data.
Upon completion of construction, prior to issuance of a Certificate of Occupancy,
and prior to operation of this permitted facility, a certification must be received
from an appropriate designer for the system installed certifying that the permitted
facility has been installed in accordance with this permit, the approved plans and
specifications, and other supporting documentation. Any deviations from the
approved plans and specifications must be noted on the Certification. A
modification may be required for those deviations.
8. If the stormwater system was used as an Erosion Control device, it must be
restored to design condition prior to operation as a stormwater treatment device,
and prior to occupancy of the facility.
9. Access to the stormwater facilities shall be maintained via appropriate
easements at all times.
10. The permittee shall submit to the Director and shall have received approval for
revised plans, specifications, and calculations prior to construction, for any
modification to the approved plans, including, but not limited to, those listed
below:
a. Any revision to any item shown on the approved plans, including the
stormwater management measures, built -upon area, details, etc.
b. Project name change.
C. Transfer of ownership.
d. Redesign or addition to the approved amount of built -upon area or to the
drainage area.
e. Further subdivision, acquisition, lease or sale of all or part of the project
area. The project area is defined as all property owned by the permittee,
for which Sedimentation and Erosion Control Plan approval or a CAMA
Major permit was sought.
f. Filling in, altering, or piping of any vegetative conveyance shown on the
approved plan.
11. The permittee shall submit final site layout and grading plans for any permitted
future areas shown on the approved plans, prior to construction.
12. A copy of the approved plans and specifications shall be maintained on file by
the Permittee for a minimum of ten years from the date of the completion of
construction.
Page 4 of 7
State Stormwater Management Systems
Permit No. SW8 001009 Modification
13. The Director may notify the permittee when the permitted site does not meet one
or more of the minimum requirements of the permit. Within the time frame
specified in the notice, the permittee shall submit a written time schedule to the
Director for modifying the site to meet minimum requirements. The permittee
shall provide copies of revised plans and certification in writing to the Director
that the changes have been made.
III. GENERAL CONDITIONS
This permit is not transferable except after notice to and approval by the Director.
In the event of a change of ownership, or a name change, the permittee must
submit a formal permit transfer request to the Division of Water Quality,
accompanied by a completed name/ownership change form, documentation
from the parties involved, and other supporting materials as may be appropriate.
The approval of this request will be considered on its merits and may or may not
be approved. The permittee is responsible for compliance with all permit
conditions until such time as the Division approves the transfer request.
2. Failure to abide by the conditions and limitations contained in this permit may
subject the Permittee to enforcement action by the Division of Water Quality, in
accordance with North Carolina General Statute 143-215.6A to 143-215.6C.
3. The issuance of this permit does not preclude the Permittee from complying with
any and all statutes, rules, regulations, or ordinances, which may be imposed by
other government agencies (local, state, and federal) having jurisdiction.
4. In the event that the facilities fail to perform satisfactorily, including the creation
of nuisance conditions, the Permittee shall take immediate corrective action,
including those as may be required by this Division, such as the construction of
additional or replacement stormwater management systems.
5. The permittee grants DENR Staff permission to enter the property during normal
business hours for the purpose of inspecting all components of the permitted
stormwater management facility.
6. The permit may be modified, revoked and reissued or terminated for cause. The
filing of a request for a permit modification, revocation and reissuance or
termination does not stay any permit condition.
7. Unless specified elsewhere, permanent seeding requirements for the stormwater
control must follow the guidelines established in the North Carolina Erosion and
Sediment Control Planning and Design Manual.
8. Approved plans and specifications for this project are incorporated by reference
and are enforceable parts of the permit.
9. The permittee shall notify the Division any name, ownership or mailing address
changes within 30 days.
Permit issued this the 10`h day of January, 2005.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
Alan W. Klimek, N.E., Uirector
Division of Water Quality
By Authority of the Environmental Management Commission
Page 5 of 7
OFFICE USC ONLY
Date Received
Fee Paid
Permit Number
/S' OBI
T%O•UJ
5618 00/00,q G/
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
This fin•m maY he pholocopied.fir use as an original
GENERAL INFORMATION
I. Applicants name (specify the name of the corporation, individual, etc. who owns the project):
Smith Creek Storage Ffteilitr. the -. z . L
2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance):
Richard Blacher, Owner
3. Mailing Address for person listed in item 2 above:
5633 Market Street
Citv: Wilmington State: NC Zip: 28405
Telephone Number: 910-799-5433
4. Project Name (subdivision, facility, or establishment name — should be consistent with project name oil
plans, specifications, letters, operation and maintenance agreements, etc.):
Smith Creek Storage Facilitv Phase I
5. Location of Project (street address):
Service Road (SR 2650)
City: Wilmington County: New Hanover
6. Directions to project (from nearest major intersection):
From the intersection of US Hwy 17 and Hwv 74 travel I block northeast. turn left on Service Road.
Site is on right on Service Road.
7. Latitude : N 340 00' 00' Longitude: W 770 00' 00" of project
8. Contact person who can answer questions about the project:
Name: Jodie Grav Telephone Number: 910-251-1191
IL PERMIT INFORMATION:
1. Specify whether project is (check one): New Renewal X Modification
Form SWU-101 Version3.99 Page I of
2. If this application is being submitted as the result of a renewal or modification to an existing permit, list
The existing permit number SW8001009 MOD and its issue date (if known) 9/2/03
3. Specify the type of project (check onc):
Low Density X High Density Redevelop General Permit Other
4. Additional Project Requirements (check applicable blanks):
CAMA Major X Sedinnentation/Erosion Control _ 404//401 Permit NPDES Stornnwater
Information on required state permits can be obtained by contacting the Customer Service Center at
1-977-623-6748.
Ill. PROJECT INFORMATION
I. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative
(one to two pages) describing stornnwater management for the project.
wet detention
2. Stormwater runoff from this project drains to the Cape Fear River basin.
3. Total Project Area: 3.64 acres
5. Flow many drainage basins does the project have'? I
4. Project Built Upon Area: 71.0_ %.
6. Complete the following information for each drainage area. If there are more than two drainage areas in the
project, attach an additional sheet with the information for each area provided in the same format as below.
Receiving Stream Name Seth -Creek
Receiving Stream Class C-SW
Drainage Basin Area 3.64 yy�
Existing Impervious * Area
Proposed Impervious * Area 2.57
% Impervious* Area (total) 71 %
69,182 sf
On -site Sidewalks 486
Other on -site -Future 2.2 sf
Off -site
'total: I E=111,929 sf I E_
* hnnelvieic nren is defined as the built noon area inchudiny. but not limited to. buildings, roads. parking
areas sidewalks. gravel areas. etc.
Form S WU-101 Version 3.99 Page 2 of 4
7. How was the off -site impervious area listed above derived'?
IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS
The following italicized deed restrictions and protective covenants arc required to be recorded for all
subdivisions, outparccls and future development prior to the sale of any lot. If lot sizes van, significantly, a
table listing each lot number, size and the allowable built -upon area for each lot must be provided as an
attachment.
1. The Jollowing covenants are intended to ensure ongoing compliance with state stormwaier management permit
number as issued by the Division of 61'ater Oaaliry. These covenants may
not be chongecl or deleted without the consent of the State.
2. No more than � square fi et c?f any lot shall be covered by simcmres q f impervious materials.
Intpemous materials include aspholt gravel, concrete, brick. stone, slate or similar internal but do not inchide wood
decking or the waterswface ol'swnnming pools.
3. Sbvales shall not he filled in, piped or altered except as necesrary to provide driveway crassingr.
4. Buill-upon area in excess of dte permitted anwunt requires a stare stornm ater ianagement pernut mooification prior
to conslniclion.
5. All pertained nunglI Juan olaparcels or future development shall be directed into the permitled slorimrater control
sitsteta. These connections to the sta•niwaler control spsteni shall be performed in a manner that maintains the
integril), anal pel formonce of the system as permitted
By your signature below, you certify that the recorded deed restrictions and protective covenants for this project
Shall inclucle all the applicable items required above, that the covenants will be binding on all parties and
persons claiming wider them, that they will run with the land, that the required covenants cannot be changed or
deleted Without concurrence from the State, and that they will be recorded prior to the sale of any lot.
V. SUPPLEMENT FORMS
The applicable state stonnwater management permit supplement forni(s) listed below must be submitted for
each BMP specified for this project. Contact the Stornnwater and General Permits Unit at (910) 733-5083 for
the status and availability of these forms.
Form SWU-102
Form SWU-103
Form SWU-104
Form SWU-105
Form SWU-106
Form SWU-107
Form SWU-108
Font SWU-109
Wet Detention Basin Supplement
Infiltration Basin Supplement
Los\ Density Supplement
Curb Outlet System Supplement
Off -Site System Supplement
Underground Infiltration Trench Supplement
Neuse River Basin Supplement
Innovative Best Management Practice Supplement
Form SWU-101 Version 3.99 Page 3 of 4
VI. SUBMITTAL REQUIREMENTS
Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ).
A complete package includes all of the items listed below. The complete application package should be
submitted to the appropriate DWQ Regional Office.
I. Please indicate that you have provided the following required information by initialing in the space
provided next to each item.
Applicant's Initials
• Original and one copy of the Stormwater Management Permit Application Form
• One copy of the applicable Supplement Fornn(s) for each BM P
• Permit application processing fee of $420 (payable to NCDENR)
• Detailed narrative description of stormwater treatmenthnanagentent
• Two copies of plans and specifications, including:
- Development/Project name
- Engineer and firm
- Legend
- North arrow
Scale
- Revision number and date
- Mean high water line
Dimensioned property/project boundary
- Location map with named streets or NCSR numbers
- Original contours. proposed contours, spot elevations, finished floor elevations
- Details of roads, drainage features. collection systemmmeas
ures-
and storwater control
Wetlands delineated, or a note on plans that none exist
- Existing drainage (including off -site), drainage easements. pipe sizes, nmoll calculations
- Drainage areas delineated
- Vegetated buffers (where required)
VI1. AGENT AUTHORIZATION
If you wish to designate authority to another individual or firm so that they may provide information on your
behalf, please complete this section.
Designated agent (individual or firm): Crimp En ineerinK. P C
Mailing Address: 419 Chestnut Street
Citv: Wilmington State: NC Zip: 28401
Phone: (910)763-5100
Vill. APPLICANT'S CERTIFICATION
Fax: (910) 763-563 1
1, (/mint or type name orperson listed in General /nlormation. item 2) Richard Blacher
certify that the information included on this permit application form is, to the best of my knowledge, correct and
that the project will be constructed in conformance with the approved plans; that the required deed restrictions
and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A
NCAC 21-1.1000.
Signature: ��✓/i�:d/t Cfnc��r/ Date:
Form S WU-101 Version 3.99 Page 4 of 4
TMC/FAYLOR CONSTRUCTION, INC. P.O. Box 2657
TO: MS. RHONDA HALL
NC DIVISION OF WATER QUALITY
Wilmington, NC 28401
Phone #: (910) 251-1181
Fax #: (910)251-9197
Date: II/15/04
Project: SMITH CREEK STORAGE FACILITIES, INC. Job # 6768B
SW8001889 MOD
Gentlemen:
We are sending via ❑ Mail Messenger ❑ Overnight
COPIES
SHEETNO.
SHEET
DATE
ITEMS
(SEE LISTED BELOW)
These items are being sent for the purpose checked below:
❑ For Approval ❑ Approved as Submitted
❑ For Job Use ❑ Approved as Noted
❑ To Place Order ❑ Returned for Corrections
❑ To Fabricate ❑ Resubmit Copies for Approval
❑ Quotation ❑ Submit Copies for Distribution
❑ For Your Use
Please. return copies of Drawings, Noting Approval
Remarks:
Check #0922 (NCDENR)
Stormwater Management Permit Application
Stormwater Management Permit Application (Wet Detention Basin Supplement)
2 copies of Site Plan drawing #CI _
I n11157nn
I.�wa
00/00 9 M06
Sincerely,
�D
C-TAYLO�STRUCTION, INC.
TMC
TAYLOR CONSTRUCTION, INC.
P.O. Box 2657 • Wilmington, NC 28402 • 910.251-1181 • Fax 910-251-9197
Ms. Rhonda hall
N.C. Division of Water Quality
127 Cardinal Drive Extension
Wilnungton, NC 28405
RE: Smith Creek Storage Facilities. Inc.
SW8001009 Mod
Dear Ms. Hall:
November 12, 2004
.;1
\\Z
RECEIVED --
sw�,v i 5 2004
BY: 66 09h90
Please ftud enclosed the Application for Modification to SW Permit #iSW80O1009 Mod. Included are the following:
I. Correct building #2 size.
2. Add building #3 to drawing.
3. Change building area square footage.
d. Change pared area square footage.
If any other informalion is needed please call our office at (910) 251-1 181. Thank you ill advance for your
consideralion in this matter.
Sincerely
TMC-Tavlor Construction. Inc.
Isel J: G
1JG111/lo
cc: Richard Blacker