Loading...
HomeMy WebLinkAboutSW6220805_Plansheet C-4.0 - Other_20221019I I I I I STEWART MASON DRIVE I N/F I ITE *Ln I I BROOKIE SCOTT HOWARD, 0 I I BROOKS DOUGLAS HOWARD &, TIMOTHY RAY HOWARD I DB 3270, PG 28 SR 1711 BRINKLEY ROAD I PB 98, PG 125 I I JOHNSON BACK ROAD I 13/4" EIPWITH 1/2" PP 1/2" ERB ERB SR 171 NORTH I ii I VICINITY MAP N/F I \ , • JOSEPH F. BYRD, JR NOT TO SCALE DB 805, PG 259 I \ I ' APPROXIMATE LOCATION I I OF EXISTING WATERLINE EXISTING POWER UTILITIES 1/2" TO BE RELOCATED I `2 N/F BROOKS DOUGLAS HOWARD & WIFE, CONNIE MOORE HOWARD DB 1266, PG 516 PB 98, PG 125 O I I I I I I I 1/2" ERB 4 N/F CARLOS CANALES & WIFE, HARLYN CANALES DB 2247, PG 928 PC F, SLIDE 717C 0 I I I I I I I 1/2" ERB 0 ( 6 N/F MANUEL GARCIA JUNIOR DB 1510, PG 287 PC F, SLIDE 717C ERB _ — EPK — 246 I 9+70.43 10+00 11+00 ` — 2�a 12+0p \ 15+78.3 — TIE TO EXISTIIisv ` B0� WATERL6 W6 6"X6'X2TEE n' 10' UTILITY EASEMENT N/F12"JOSEPH FITZERALD BYRD, JR. 1,4 110+18.8 DB 1972, PG 679 I \ ` o 13j 00 1 8 6"X2" REDUCER 2+GV I LEGEND: TBM I 1/2" 10 F56.4 1/2 Q5 13+30.0 Ecs ERB ERB FH 2 — 14+06ALDERMAN COURT _ — 16+00 16+20.9, O ECS-EXISTING COTTON SPINDLE 4D DISK #1 I 12+59.2 I 50' R/W (PUBLIC & UTILITY ACCESS) T EIP N 585,284.691 (0 EIP-EXISTING IRON PIPE E 2,115,324.766 10+21.0 6" GV �� _ W2 W2 / EIR Oo EIR-EXISTING IRON ROD ELEV 244.58 I / 2 GV 12+88.0 EPK INC GRID NAD 83 I � 13+39.4 O EPK-EXISTING PK NAIL 11.25' BEND 2" GV ERB (2011) 1 10+39.7 I N — — — — — sReO ERB-EXISTING REBAR NAVD 88 1/2„ I � r ERB I O SRB-SET REBAR a \ o COMPUTED POINT EPK I I I I I I I 1/2" EIR WN L N/F - NOW OR FORMERLY I �� , 1 — R/W - RIGHT OF WAY ��2 01 ' D PROPERTY LINE N/F ij � I \ LATQSHA DIANE WILSON I _j 0 ADJACENT PROPERTY LINE DB 3996, PG 692 r 1 x J I TIE LINE N/F I P 2021, PG 179 15 < a I I \ RIGHT-OF-WAY MARCUS ANTHONY TART & WIFE, , v 1 -SETBACK LINE ANGIE S. TART , MI I I 10 O \ DB 2093, PG 576 I I • �\\ \ SD STORM DRAINAGE Z , _0 // OVERHEAD UTILITY ❑ ❑ VINYL SPLIT RAIL FENCE TREE LINE 210 MAJOR CONTOUR 207 MINOR CONTOUR io �\ — 30'— 30'— 30' VEGETATED BUFFER x 208.47'SPOT ELEVATION 1E/R Pa ERB BENCHMARK I o S-,GN SIGN FMB 12+29.4 PP UTILITY POLE I Cl) I I / 42" BO C• GUY WIRE FIRE HYDRANT I o ASPHALT Cn = UNSUITABLE SOILS I T 14 0 SURFACE WATER N/F ;p I PROPOSED FIRE HYDRANT ROBERT LYNN WILLIAMS & WIFE, ' oo GD , ❑■ PROPOSED WATER METER VICKIE C. YANDLE I p , I H PROPOSED WATER VALVE \ DB 3938, PG 855 I Z N PROPOSED TAP SLEEVE AND VALVE , • PROPOSED BLOW OFF \ I IS -(PROPOSED TEE I O "PROPOSED 22.5' BEND "PROPOSED 11.25' BEND 10 PROPOSED REDUCER I 1 I 12+32.8 __, 2" GV 13 0 (� 8 \1 N/F DON L. AGNEW JR. & WIFE, PAT M. AGNEW DB 3373, PG 255 PC F, SLIDE 717C 1/2" EIR N 585,545.541 E 2,116,135.208 NC GRID NAD 83 (2011) N/F EUGENE B. GOMES, MARTHA ROMANA GOMES, JOSEPHINE GOMES &, SOLOMAN GOMES DB 2179, PG 561 SEE SHEET G-1.0 FOR UTILITY NOTES I 12 30 3° 30 *SIDEWALKS AND STREET TREES ARE TO BE MAINTAINED BY THE ' , I 3EIP 40 N 684,932.900 E 2,116,056,889 HOME OWNERS ASSOCIATION ("HOA"), PROPERTY OWNERS 30. I I i ��i23E I NC G(12D011)D 83 ASSOCIATION ( POA ), CONDOMINIUM OWNERS ASSOCIATION ( COA ), 0./ oII I OR ANY OTHER ASSOCIATION RESPONSIBLE FOR THE MAINTENANCE AND/OR UPKEEP OF THE RESIDENTIAL COMMUNITY. SIDEWALK OR I I I / s I STREET TREE INSTALLATIONS THAT ARE DAMAGED AND/OR REMOVED BY HARNETT COUNTY/DEPARTMENT OF PUBLIC UTILITIES/HARNETT N/F ; I 0_- S°t&T REGIONAL WATER OR ITS REPRESENTATIVES AGENTS OR ROBERT MICHAEL LEE & WIFE, ECS• o ' ' LINDA POINDEXTER LEE CONTRACTORS, AS A RESULT OF REPAIR/MAINTENANCE OF THE DB 4072, PG 634 I I \� I PUBLIC WATER AND/OR SEWER LINE WILL BE REPLACED OR ' I REPAIRED BY THE HOA, POA, COA, OR ANY OTHER ASSOCIATION I , I RESPONSIBLE FOR THE MAINTENANCE AND/OR UPKEEP OF THE 3 4J`\y 110- _ I RESIDENTIAL COMMUNITY. I EIP ♦```•' \30 _�_�—�'—�'� �'—�'—�'—�'—�'—� 3° I 00 30'—30 —30 p ♦ 30' — 30• \ — Q I - it 3 4" ♦ ����� _�—�� �� EIP I Z o 3 4„ • I �P *APPROVAL OF THIS PLAT/PLAN DOES NOT GUARANTEE WATER I I ® OR SEWAGE TREATMENT CAPACITY. CURRENT/FUTURE CAPACITY I N/F MAY NOT BE AVAILABLE. THIS DEVELOPMENT MAY REQUIRE ROBERT MICHAEL LEE &WIFE, Q GRAPHIC SCALE LINDA PTER LEE ADDITIONAL IMPROVEMENTS TO THE EXISTING WATER SYSTEM I DB 407272, , PG 634 OR SEWER SYSTEM TO MEET FUTURE WATER AND SEWER 50 0 25 50 ,00 Know what's below. Call before you dig. DEMANDS PRIOR TO A PRELIMINARY PLAT, CONSTRUCTION PLAN AND/OR FINAL PLAT APPROVAL I ( IN FEET > 1 inch = 50 ft. I THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED 200 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite.U2, Fayetteville, INC 28306 office 1910-426-6777 fax 1910-426-5777 license number I C-2354 www.4Dsitesotutions.com �CAROZ// 40 SEA 02 • G I NE •: ja��� �O I I111\� REVISIONS PROJECT NAME FAIRGROUND FARMS SUBDIVISION UTILITY PLAN PIN: 1518-55-7140.000 CLIENT AGS LAND, LLC 1786 Metromedical Drive Fayetteville, North Carolina 28304 Phone: (910) 779-0019 PROJECT INFORMATION DESIGNED BY: BRETT DRAWN BY: BRETT CHECKED BY: SCOTT PROJECT NUMBER: 1862 DRAWING SCALE HORIZONTAL: 1 "=50' DATE RELEASED SEPTEMBER 15, 2022 SHEET NUMBER