Loading...
HomeMy WebLinkAboutIredell_Well Abandonment_20221118 WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Matt Steele 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only I GW-30 is needed. Indicate TOTAL NUMBER of 4548A — : , ; . '�. wells abandoned: NC Well Contractor Certification Number Z 7b.Approximate volume of water remaining in well(s): (gal.) Geological Resources, Inc. Nov 1 8 2022 FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: 2.Well Construction Permit#: ✓� ` � List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.)ifknown 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑ Neat Cement Grout a Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) N Concrete Grout ❑ Drill Cuttings ❑lrri ation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g) RMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation Bentonite 62lbs ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage Grout ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer added bentonite to fill entirety of ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) well - pad removed, replaced with gravel 4.Date well(s)abandoned: 1 0/10/2022 5a.Well location: Speedway#7970 (Statesville) 00-0-0000033196 Facility/Owner Name Facility lD#(ifapplicable) 8.Certification: 1,,.�'"'�� 122 Turnersburg Highway, Statesville NC 28625 10/10/2022 Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Iredell 4745349635 By signing this form, 1 hereby certify that the well(s) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has been provided to the well owner. (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details: 35.809027 N -80.875792 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELLS)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)ifavailable. For multiple injection ornon-water supply wells ONLY with the same construction/abandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: T V V`/�,—l abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 43.98 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Infection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter:.4.5 (in.) above, also submit one copy offthis form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 17.26 (ft.) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 i 6e.Outer casing length(if known): 30 (ft.) 10c.For Water Supply&Infection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion A of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): 4" (ft.) abandoned. 6g.Screen length(if known): 5 (ft.) Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016