Loading...
HomeMy WebLinkAboutSW4220801_Plansheet C-1.4 - Grading_Drainage Plan_20220825A NOTE. NO WETLANDS ARE LOCATED WITHIN THE AREA OF THE PROPOSED DEVELOPMENT AS THE ENTIRE AREA OF PROPOSED IMPROVEMENTS IS CURRENTLYAN AGRICULTURAL FIELD THAT IS REGULARLY DISTURBED. THE FLOODPLAIN AREA HAS NOT BEEN EVALUATED FOR SUCH FEATURES e---, L3 MOTES CREEK SURFACE AREA SHOWN PER SURVEY SHOTS ON TOP OF BANK w/30' VEGETATED SETBACK. TOTAL ONSITE AREA = 21,036 SF I I I \ I I MARK WAYNE & DONNA T SHARPE 167903 ALAMANCE COUNTY DB 3518 / 277 SIZE. 86.73 AC USE: GENERAL FARM WESTERN BOUNDARY DEFINED BY THE CENTERLINE OF "MOTES CREEK" PER EXISTING BOUNDARY SURVEY BY BOSWELL SURVEYORS, INC. JOB NO. 20-101-400 DATED 411612020 U / / I I I I � L L� � I I I 0 L \ L I JERALINE M CURTIS 161902 ALAMANCE COUNTY DB 30571993 SIZE: 39.89 AC USE: GENERAL FARM L� MOTES CREEK SURFACE AREA SHOWN PER SURVEY SHOTS ON TOP OF BANK ( w/30' VEGETATED SETBACK. / TOTAL ONSITEAREA = 21,036 SF MELVIN DENTON 161953 ALAMANCE COUNTY DB 4134 / 478 C - SIZE. 12.17AC USE: VACANT 10'Wx15'Lx22" T CLASS B / RIP RAP AT THE DITCH/DIVERSION OUTLET 22 \\ 14769 SF 0.80AC /- 25 /Y 23 I 24 �/ 3147S SF�3022 I I 263161 SF 72 - - L - - 72-M - - - - v by H� - 33360 SF 0 Ar ---a 3 � "Y ✓ I 0 77AC I / , --- - _ 27 I \ \ / �- J 43676 SF I 1111 �I / PD-1 DRAINAGE AREA / I C \ / _ _ 1.00A_ / 21 5641 SF I \ PD-1 / 2.20 AC � �M / 411 EX. TREELINE h �6 41 ° \ y52 5Q / ZONE AE (100 YEAR) Slob �r%.cscs�si%ai: 41 h 5gs rA 4? by / / / 556 II h 5p5 / hh h�M h� h 35LF 75" CLASS IV RCP: yob / h" may/ �,1 \ 1 INV. IN = 535.00 o ha 9� I / a / PD-2 5y � INV. OUT = 534.65 � � h h `� /SLOPE = 1.00% .g6 20 \ 30LF 15" CLASS IV RCP:- \ 65820 SF / \ OUT 536.00 1s1.ac INV. \ \ SLOPE = 2.00% PD-2 DRAINAGE AREA / 1 � / -562 A oma Lx22"T CLASS RIP RAP AT THE 18 I I DITCH/DIVERSION OUTL�T 30854 SF \, - - 16 0.71 AC 1 30444 SF / - - \ 0.70 AC / 32078 SF 32501 SF I V 19 I 0.74 AC 0.75 AC I 4 _ 5;"87 SF- _ / 36726 SF i I I r 1.36 AC I\ I I I 0.84 AC /� PHASE o 10 ko 10 Ve \ > \ 13 LOT 21 OFFSITE I / �o J I I / \ l 44479 SF SEPTIC SOIL I I \ / �`' / %� \ 1.02 AC SUPPLYLINE J\ /° /\ EASEMENT Ile 12 e'7580 SF LOT 21 \ \ \ \ / / N\ \ \ / � \ \ w A\ \ \ � OFFSITE AREAL i \ PHASE 6 LOTS 1-13 y5 / SUBMITTED / 51 w SEPARATELYAS \\ sw I I \ I \ PRELIMINARY PLAT 10 by ON 11/02/21 47580 SF 1.09 AC / 9 / 47580 SF 1.09 AC %� /�- / I I \ I I 1 \ r I / / 8 / N GRID COORDINATES D 83(2011) 809532.69 1912817.73 75LF 78" CLASS IV RCP.- INV. IN = 556.80 INV. OUT = 556.05 SLOPE = 1.00% MARVIN MORROW NEWLIN REV TRUST 161902 ALAMANCE COUNTY DB 22121146 SIZE: 298.8 AC USE: GENERAL FARM L, L, L, L, NOT SURVEYED DUE TO FLOODING AT TIME OF FIELD WORK FLOOD PLAIN AREA GRADING AND STORM DRAINAGE NOTES: 1. EXISTING TOPOGRAPHY & SITE CONDITIONS SURVEYED BY TRIANGLE SURVEYORS, DATED JUNE 15, 2021. 2. ALL PIPE TO BE INSTALLED ON -SITE AND IN THE RIGHTS OF WAY SHALL MEET OR EXCEED THE NCDOT ASTM AND AASHTO SPECIFICATION REQUIREMENTS FOR SUCH PIPE MATERIAL. 3. ALL ON -SITE PIPE SHALL BE INSTALLED MEETING COVER, BACKFILL AND BEDDING REQUIREMENTS PER NCDOT OR THE MANUFACTURER'S RECOMMENDATIONS, WHICHEVER IS MOST STRINGENT. 4. CONTRACTOR SHALL FIELD VERIFY THAT PROPOSED GRADES MATCH EXISTING PAVEMENT AT ALL CONNECTIONS/TIE-INS. CONTRACTOR SHALL NOTIFY ENGINEER IF DISCREPANCY OCCURS. S. ALL WORK WITHIN NCDOT ROW SHALL COMPLY WITH MOST RECENT NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, NCDOT STANDARD DRAWINGS, AND THE MUTCD STANDARDS. 6. ALL ONSITE STORM DRAINAGE CONSTRUCTION SHALL COMPLY WITH MOST RECENT NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, AND NCDOT STANDARD DRAWINGS. 7. THE GRADE LINES DENOTE THE FINISHED ELEVATIONS OF THE PROPOSED SURFACE. GRADE LINES MAY BE ADJUSTED AT THEIR BEGINNING, ENDING AND AT STRUCTURES AS DIRECTED BY THE ENGINEER IN ORDER TO PROVIDEA PROPER TIE-IN. CONTRACTOR SHALL FIELD VERIFYALL PROPOSED INVERTS, FFE'S & FINISHED SURFACES TO ENSURE THAT MINIMUM SLOPE & COVER REQUIREMENTS ARE PROVIDED PRIOR TO INSTALLATION OF REFERENCED ITEMS. CONTACT ENGINEER WITH DISCREPANCIES. 8. THE EARTHWORK ON THIS PLAN DOES NOT NECESSARILY BALANCE, • OFFSITE BORROW OR WASTE MAY BE REQUIRED AND SHALL BE INCLUDED IN CONTRACT PRICE/BID. OFFSITE BORROW/WASTE AREAS SHALL BE PERMITTED. 9. ALL PIPE INVERTS TO BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTING GRAVITY SYSTEMS AND SHALL BE ADJUSTED BY THE ENGINEER IF NECESSARY. 10. OUTLET STRUCTURES AND OUTFALLS SHALL CONSIST OF FLARED END STRUCTURES (FES) UNLESS OTHERWISE NOTED. RIPRAP APRONS SHALL BE THE OUTLET. I I / GRAPHIC SCALE 69230 SF / / /\ / / ✓ / I I 1.59 AC h' 25 0 25 50 100 I y (IN FEET) I 1 inch = 50 ft. Know what's below. Call before you dig CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. o W U � 0 H 0 Z 00 o N N 10,01 �oQ o M N V 0-113 J J 1L = a � z o ��nn W U I W Wz ;t ip �cc,�E z ❑W �r-z ;�aN zU rz 00 uZm X. C] OMOlfl M Q �EW@N U'O is0i ZNaU vat NOT FOR 0362422 Ill CONSTRUCTION N N N N N N W O Z � z Z W �U � � W z � O U o U o 2 ­1 � w V M J r r� V J N O un C3 PROJECT #: 21-026 REVIEW PROJECT #: XX-XXX SHEET #: C-1.4