HomeMy WebLinkAboutGranville_Well Abandonment_20221111 (2) WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Steven R. Gerrald 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of 4309-B wells abandoned:-' 0'9 NC Well Contractor Certification Number 7b.Approximate volume of water'remaining in well(s): (gal.) Leaf Environmental & Engineering, P.C. FOR WATER SUPPLY WELLS ONLY:Company Name 7c.Type of disinfectant used: RECEIVED 2.Well Construction Permit#: N/A NOV 1 1 202Z List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.)ifknown 7d.Amount of disinfectant used: 3.Well use(check well use): Irg"priaudin P=asviac I PAN] DWOSOG Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑ Neat Cement Grout le Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings ❑Irri ation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g) INMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation Bentonite Chips - 30 Ibs ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Gravity pour bentonite chips monitored using weighted tape. Distilled water added for hydration above water table. 4.Date well(s)abandoned: 10/21/22 5a.Well location: Jacks Best Buy Jack's Best Buy Incident No.39227 Facility/Owner Name Facility ID#(ifapplicable) 8.Certification:Z / 315 Central Avenue, Butner, NC 27509 Physical Address,City,and Zip Stgn tore of Certified Well Contractor or Well Owner Date Granville By signing this form, I hereby certify that the well(s)was(were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well;details: 36.13454 N 78.75931 �, You may use the back of this page!to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Atiachwellconstructionrecord(s)ifavoilable. For multiple injection or non-water supply wells ONLY with the same construction/abandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: MW-3 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 17 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 i 10b.For Iniection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 6 (in.) above,also submit one copy of this form within 30 days of completion of well abandonment to the following: 11.5 Division of Water Resources,Underground Injection Control Program, 6d.Water level below ground surface: (ft.) 1636 Mail Service Ceuter,Raleigh,NC 27699-1636 i 6e.Outer casing length(if known): 7 (ft.) 10c.For Water Supply&Iniection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6E Inner casing/tubing length(if known): NA (ft) abandoned. I 6g.Screen length(if known): 1 (ft.) Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016 f � WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Steven R. Gerrald 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30'is needed. Indicate TOTAL NUMBER of 4309-B wells abandoned:1 2 NC Well Contractor Certification Number 7b.Approximate volume of water'remaining in well(s): (gal.) Leaf Environmental & Engineering, P.C. FOR WATER SUPPLY WELLS ONLY: R E C E IV E Company Name 7c.Type of disinfectant used: t 2.Well Construction Permit#: N/A NOV 1 1 2022 List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.)ifknown 7d.Amount of disinfectant used: n 3.Well use(check well use): DWOM G Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout a Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings ❑Irrigation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g) eMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation Bentonite Chips - 30 lbS ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of fbe abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer Gravity pour bentonite chips monitored using weighted ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) tape. Distilled water added for hydration above water table. 4.Date well(s)abandoned: 10/21/22 5a.Well location: Jacks Best Buy Jack's Best Buy Incident No.39227 Facility/Owner Name Facility ID#(if applicable) 8.Certification: 315 Central Avenue, Butner, NC 27509 � Physical Address,City,and Zip Sfgnature Certified Well Contractor or Well Owner Date Granville By signing this form, 1 hereby certify that the well(s) was(were)abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lat/long is sufficient) 9.Site diagram or additional well details: 36.13454 N 78.75931 W You may use the back of this page'to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction records)ifavailable. For multiple injection or non-water supply wells ONLY with the some construction/abandonment,you can submit one form. 10a. For All Wells: Submit this"form within 30 days of completion of well 6a.Well ID#: MW-4 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 17.5 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Iniection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 6 (in.) above,also submit one copy of this form within 30 days of completion of well abandonment to the following: k 11.5 Division of Water Resources,Underground Injection Control Program, 6d.Water level below ground surface: (ft.) 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): 7.5 (ft,) 10c.For Water Supply&Iniection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): NA (ft.) abandoned. i' 6g.Screen length(if known): 10 (ft.) f I Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016